About This Manual
This document contains instructions for the usage and installation of the
RADIONODE® RN320. Product specifications and certain features herein may be
subject to change without prior notice. Figures used in this manual are for
explanatory purposes only and may differ from your system depending on
installation conditions. Software screenshots may change after software
updates
Intellectual Property Rights
© 2021 DEKIST Co., Ltd. All contents and figures herein are property of
DEKIST Co., Ltd. Reproduction or redistribution of all or part of this
document in any way is not permitted without prior consent from DESIST.
Notational Conventions
Failure to follow instructions marked with “Warning” may result in slight
injury to the user.
Failure to follow instructions marked with “Caution” may result in equipment
damage or malfunction.
Additional helpful information is marked with “Note”.
Introduction
RN320 Wireless gas transmitter is designed to measure temperature, humidity,
and CO2 gas and transmit them to the cloud system via Erwan. LORAWAN have
different RF frequency for each country.
CH1 CO2
CH2 TEMP
CH3 RH
Warning
This products have LORAWAN wireless protocol. user should have a LORAWAN gateway (receiver). Without lorawan gateway, this product could not work properly.
**Major Features
**
RN320’s Major features
- LORAWAN is used for sending temp, RH, and CO2 gas information.
- Radionode365 is a dedicated cloud service for RN320 wireless gas transmitter
- This product is using C type 3.6V battery
- Sensor parts can be replaceable easily
RF Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20
cm between the radiator & your body.
Exterior
Dimensions 115mm x 115 mm x 50 mm
- Display
- Front Button,
- Status LED,
- Bracket Connector
Interior
- Battery holder
- Gas Sensor
- Back Cover
Accessory
C Type 3.6V | Bracket | USB Cable |
---|---|---|
Please Use the same battery that is included in the box. Otherwise, malfunction may occur.
Specification
RN320 wireless gas transmitter
CO2 sensor : 0 ~ 2000 ppm
temp. sensor : -40 ~ 80 ‘C
RH sensor: 0 ~ 95% RH
battery: 3.6V C Type Battery X 2 (parallel )
Wireless: LORAWAN
FCC: 902.3 MHz ~ 914.9 MHz(125 kHz Bandwidth) 903 MHz ~ 914.2 MHz(500 kHz
Bandwidth)
CE: 863.1 MHz ~ 869.9 MHz(125KHz Bandwidth) 863.2 MHz ~ 869.85 MHz(250KHz
Bandwidth
Dimension: 115 X 115 X 50 mm
Operation: -20’C ~ 60’C
USB Type: USB C TYPE
(USB C port is only for Installer or Engineer. It is not used for normal
operation.)
Display: E-PAPER
IP Rate: None
Installation
Once you put the battery. RN320 device will be turned on. there is no power
switch on the device
Bracket
Attach the bracket to the wall first. turn RN320 15 degrees to the left and
put it on the bracket. and then turn RN320 15 degrees to the right to fix it
tight
Battery
two C type 3.6V battery is used for normal operation. please be aware that
RN320 has no power switch. When pulling out the battery, this product would be
working properly using an internal supercapacitor.
Setup
In order to set up these products. connection PC (mobile) and RN320 via USB
cable is required.
Buttons
Front button click change the display contents
Zero calibration mode can be accessed by pressing the front button during 10
second
LED
RED: Initial Wireless Accessing, Warning gas level detected.
GREEN: a safe environment
BLUE: Periodic measurement and RF transmission.
Customer Service Information
Manufacturer Contact Information
DESIST Co., Ltd. provides repair services and replacement parts for
RAOIONODE products. To request customer service, contact us via one of the
following methods.
- Tel: 4(82) 1566-4359
- Fax: (+82) 31-8039-4400
- E-mail: master@dekist.com
Warranty
Repairs are provided free of charge for product failure under normal operating
conditions within one year of the product installation date.
Limit of Liability
Warranty repairs are not provided in the event of:
- Failure caused by unapproved installation methods;
- Failure caused by user negligence;
- Failure caused after alteration, disassembly, or repair of the product by a person unauthorized by DEKIST;
- Failure caused by corrosion, falling, submersion, or other improper storage methods;
- Failure caused by natural disaster or other unforeseen circumstances. such as storms, floods, earthquakes, lightning, or abnormal voltage;
- Service requested for actions that the user can take, such as replacing consumables;
- Alteration of the software through decompilation or the like;
Certifications
FCC Class B Digital Device
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment This equipment
generates. uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not expressly approved by the manufacturer
responsible for compliance could void the user’s authority to operate the
equipment.
KC This equipment has passed conformity testing for use in work
environments and is likely to cause interference when used in a household
environment.
(5)2021 DEKIST Co.. Ltd.
Telephone 1566-4359 Fax (+82) 31-8039-4400
Email master@dekist.com
#A1801. 13, Heungdeok 1-ro, Giheung-gu. Yongin-si. Gyeonggi-do. Korea
16954
Documents / Resources
|
RADIONODE RN320 LORAWAN Wireless Gas
Transmitter
[pdf] User Manual
RN320, 2ABC3-RN320, 2ABC3RN320, LORAWAN Wireless Gas Transmitter, RN320
LORAWAN Wireless Gas Transmitter, Wireless Gas Transmitter, Gas Transmitter,
Transmitter
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>