HONEYWELL CM702 PROGRAMMABLE THERMOSTAT Product Specification Guide
- October 30, 2023
- Honeywell
Table of Contents
HONEYWELL CM702 PROGRAMMABLE THERMOSTAT
View all Honeywell thermostat manual
PRODUCT SPECIFICATION SHEET
The CM702 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in conjunction with combi boilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves, and electric heat systems (<5A). The CM702 is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The CM702 large LCD display, button layout based on the same simple programming philosophy used on our acclaimed CM20 products and the introduction of an ‘OK’ button makes it easier to install and more user friendly. The CM702 features a unique programming function that allows the user to select an alternative time & temperature profile whenever their lifestyle requirements change (e.g. weekend, bank holiday). The unit is ideal for consumers who want reliable precise temperature control from a modern- looking, simple-to-program and easy-to-use product.
FEATURES
- Attractive slim, modern styling makes it ideal for location in any type of home.
- 24-hour heating program.
- Up to 4 daily independent time and temperature level changes let you set 4 time and temperature pairs to suit your lifestyle.
- Temporary programmed temperature override to temporarily override the programmed temperature till the next switch point.
- 1/2 Program button allows switching to an alternative heating program whenever it’s required with just one button press. This alternative program can be adjusted in exactly the same way as the normal heating program.
- Room Temperature Enquiry.
- EEPROM memory holds the user program indefinitely.
- OFF mode has an integral frost protection setting at minimum 5°C (installer adjustable) so that pipes in the house will never freeze in winter.
- 24…230V 5A resistive, 2A inductive SPDT relay provides compatibility with most domestic central heating systems reducing the need to stock many different models.
- Battery powered by 2 x AA size (LR6) alkaline cells.
- Minimum battery life of 2 years with low battery warning indicator.
- Built-in default heating program.
- Surface or wall box mounting options, with trunking guides and wiring breakouts to simplify installation.
- No installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems.
- User Set-Up Mode allows extra functions to be set at the discretion of the user:
- AM-PM or 24hr time display.
- Resetting the heating profile to factory default.
- Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumers applications and needs:
- Pump Exercise.
- Upper / Lower Set point Limit Adjust.
- Temperature offset.
- Minimum ON time.
- Cycle rate.
- Proportional Band Width.
- Diagnostic Mode to assist in fault finding
CONTROLS / DISPLAY LAYOUT
PRODUCT LAYOUT
- LCD Screen
- Battery Low Indicator
- Time Display
- Burner On Indicator
- Temperature Display
- Temperature Change Buttons
- Information Enquiry Button
- Operating Mode Buttons
- Green OK Button
- Battery Compartment
- Battery Cover
- 1 / 2 Program Button
- Program Buttons
- Time Change Buttons
SPECIFICATION
CONTROLS / DISPLAY LAYOUT
- Batteries : 2 x 1.5 V IEC LR6 (AA) Alkaline cells
- Battery life : Minimum 2 years
- Battery replacement : Program retained in EEPROM
- Switch type : SPDT (potential free)
- Electrical rating : 230 V~, 50…60 Hz, 0.1 A to 5 A resistive 0.1 A to 2 A inductive (0.6 pf) 24 V~, 50…60 Hz, 0.5 A to 5 A resistive 0.5 A to 2 A inductive (0.6 pf)
- Time display : 24 hour or 12 hour AM/PM format
- Time keeping accuracy : Typically better than 10 minutes per year Program : 2 independent sets of 4 daily time and temperature level changes that can be switched between as desired.
- Time setting resolution : Time of day – 1 minute
- Program – 10 minute steps Sensing element : 100K (@ 25 oC ) NTC thermistor
- Temperature setting range : Program : 5 to 35oC in 0.5 oC steps Frost : 5 oC or equal to lower limit (5 oC to 21 oC).
- Temperature control accuracy : ±0.5 K (nominal) @ 20oC, 50% load 3 K Δ/hour Room
- Temperature display range : From 0 oC to 50 oC
- Control form : P + I (Proportional + Integral)
- Minimum ON time : 10% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up)
- Cycle rate : Selectable by application (see installer set up)
- Wiring : Terminal block capable of accepting wires up to 2.5 mm2
- Wire access : Mains wiring – rear right.
- Low voltage wiring – rear right.
- Dimensions : 133 x 88.5 x 26 mm (w x h x d) 133 x 175 x 26 mm (w x h x d) (flap open)
- Environmental : Operating temperature range 0 to 40oC Shipping and storage temperature range -20 to 55oC
- Humidity range 10 to 90% rh, noncondensing Approvals : Designed to meet European EN approvals EN60730-1(Nov 2000), EN55014-1 (1997), EN55014-2 (2000)
INSTALLER SET-UP
To enter the installer set-up mode:
- Press the OFF button.
- Press and hold the INFO i button and the two program buttons ‘< >’ together.
- The unit will display the first parameter of installer parameter group category 1 (from n.1 to n.19).
- Press the TEMP buttons to change the factory setting. The display will flash indicating that a change has been made.
- Press the green OK button to confirm this change and the display will stop flashing.
- Press the button to go to the next parameter.
- Press the program button > to go to category 2 in the Installer mode (from n.1 to n.5).
- To exit the installer mode, press the AUTO, MAN or OFF buttons.
In Installer set-up we can:
- Set-up specific applications
- Enable special features
Specific Applications | Setting | What do you need to change? |
---|---|---|
Cycle/ Hour | Minimum ON time(in minutes) | Note : a. To change |
Cycle/Hour, please go to parameter n. 2, category 2 in the installer set-up mode.
b. To change Minimum ON Time, please go to parameter n. 1, category 2 in the installer set-up mode.
Heating| Gas Boilers (<30KW)| 6| 1| No action required
| Oil Boiler| 3| 4| 1. Set Minimum ON Time to 4 minutes.2. Set Cycle/Hour
to 3.
| Thermal Actuator| 12| 1| Set Cycle/Hour to 12.
| Zone valve| 6| 1| No action required.
| Electric heating (for applications<5A)| 12| 1| 1. Set Cycle/Hour to 12.
Special Features| Description| What to do if we wish this
feature
---|---|---
AM-PM/ 24hr Display| Change display format (default 24hr).| Set parameter n.1,
category 1 in the installer set -up mode to 12.
Pump exercise| When enabled the Pump Exercise will switch the relay on for 1
minute at 12:00 if the relay has not been switched on since 12:00 the previous
day.While in Holiday mode the Pump Exercise feature, if enabled, will
operate.| Set parameter n.5, category 2 in the installer set -up mode to 1.
Upper Temperature Limit| The normal upper temperature limit of 35 oC can be
reduced down to 21 oC to save the homeowner energy. Useful if the homeowner
rents to tenants.| Set parameter n.6, category 1 in the installer set -up mode
to the desired limit.
Lower Temperature Limit| The normal lower temperature limit of 5 oC can be
increased up to 21 oC to protect the inhabitants from cold. Useful if the
inhabitants include the elderly, children or disabled.| Set parameter n.7,
category 1 in the installer set -up mode to the desired limit.
Temperature Offset| If the thermostat is located in a hot/cold location and
cannot be moved because of wiring then the measured/ displayed temperature can
be adjusted by +/- 3 oC. Useful if the homeowner wants the reading to match
another appliance temperature display.| Set parameter n.12, category 1 in the
installer set -up mode to the desired offset value.
Proportional Band Width| Can be adjusted up to 3 oC (default is 1.5 oC) to
provide better temperature control (less overshoot).Useful for:
a. Well insulated homes with over-sized heating systems.
b. Air systems with fast response.
| Set parameter n.13, category 1 in the installer set -up mode to the desired
value.
Parameter| Installer Set-Up Number / Abbreviation (Press + or – keys
to select)| Factory Setting| Optional Setting| Installer Set-
Up Category (Press PROG keys ‘ < or >’ to select)
---|---|---|---|---
| | Display| Description| Display/Setting| Description|
Category 1: Thermostat Parameters
AM-PM / 24hr Display| 1:Cl| 24| 24 hr clock display| 12| 12 hr AM / PM clock
display| 1
RESET Time / Temperature Program| 2:rP| 1| Time / Temperature profile set to
factory default Changes to 0 when one of the time/temp profiles are changed| 0
1
| Time / Temperature are as programmedTo restore the factory profile set to 1|
1
Upper Temperature Limit| 6:uL| 35| 35°C Upper Temp. Limit| 21 to 34| 21°C to
34°C adjustment in 1°C steps| 1
Lower Temperature Limit| 7:LL| 5| 5°C Lower Temp. Limit| 6 to 21| 6°C to 21°C
adjustment in 1°C steps| 1
Temperature Offset| 12:tO| 0| No offset| -3 to +3| -3°C to +3°C adjustment in
0.1°C steps| 1
Proportional Band Width| 13:Pb| 1.5| 1.5°C Proportional Band| 1.6 to 3.0|
1.6°C to 3.0°C adjustment in 0.1°C steps| 1
Reset Parameters to Factory Defaults| 19:FS| 1| All settings held are the
factory defaults. Changes to 0 when one of the parameter values are changed| 0
1
| Settings are as modified aboveTo restore the factory profile set to 1| 1
‘Category 2: System Parameters (You must press the ‘ >’ program key to
enter this section)
Minimum ON Time| 1:Ot| 1| 1 minute minimum ON time| 2 to 5| 2 – 2 minutes3 – 3
minutes
4 – 4 minutes
5 – 5 minutes
| 2
Cycle Rate| 2:Cr| 6| 6 cycles per hour (cph) for gas boilers, zone valves and
fan-coil| 3, 9, 12| 3 – 3 cph9 – 9cph
12 – 12 cph
| 2
Pump Exercise| 5:PE| 0| Pump Exercise| 1| Pump Exercise Enabled| 2
DIMENSIONS
INSTALLATION
LOCATION
The CM702 thermostat is the control element of the heating system and,
therefore, MUST be located in a position with good air circulation, at average
room temperature and on an inside wall, 1.5 metres above the floor level. Do
not position the CM702 thermostat near sources of heat (radiators, hot air
vents, TV or lights), near doors or windows, or in direct sunlight.
MOUNTING
The CM702 thermostat can be mounted directly on the wall surface or on to an
electrical wall box.
WIRING
The CM702 thermostat is designed for fixed wiring only and must be installed
in accordance with the latest l.E.E. regulations. Ensure the wiring connection
to the supply is via a fuse rated at no more than 5 amps and a Class “A”
switch (having a contact separation of at least 3 mm in all poles).
IMPORTANT
- The installer must be a trained service engineer
- Disconnect the power supply before beginning the installation
WIRING
ORDERING SPECIFICATION
Description| Model| Logo| Literature| Availability|
Spec Sheet
---|---|---|---|---|---
1+1 day programmable thermostat| CMT702A1004| Honeywell| French, Dutch,
Italian, Spanish, German, Portuguese.| Sep 05| ENOH8545
1+1 day programmable thermostat with 6 switch points (instead of 4).|
CMT702A1012| Honeywell| French, Dutch, Italian, Spanish, German,
Portuguese.| Oct 06| ENOH8545
Honeywell
- Honeywell Control Systems Limited
- http://europe.hbc.honeywell.com
- Newhouse Industrial Estate
- Motherwell ML1 5SB
- United Kingdom