MGI WH2142-W-2 Ligature-Resistant Toilet Instruction Manual
- October 30, 2023
- MGI
Table of Contents
WH2142-W-2 Ligature-Resistant Toilet
Instruction Manual
WH2142-W-2 Ligature-Resistant Toilet
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 1.800.591.9360
Technical Assistance E-mail:
Fieldservice@acorneng.com
Important
Important: Some options may slightly alter installation. To ensure
proper installation review the manual thoroughly and verify rough-ins before
beginning any work. File this manual with the owner or maintenance personnel
upon completion of installation.
MGI Engineered Plumbing Products are designed in accord with applicable
National Codes and Standards, which may include UPC, ANSI, and ASSE.
Installers should use industry standard practice for details not covered
within Manual. Prior to installation, supply lines must be flushed of all
foreign material such as pipe dope, chips, or solder. Debris or foreign
material in water supply may damage valve. An appropriate thread sealant is
recommended on all threaded waste and supply connections to reduce the
possibility of leaks.
Toilet requires a minimum of 25 PSI flow pressure and uses a minimum water
consumption of 1.28 GPF. WH2142 Toilet fixtures are supported on-floor and are
not intended for use with In-Wall Support Carriers. Depending on wall
construction, rear wall may require backing for mounting fixture to wall.
Installer provided wall anchors and wall anchoring hardware must be
appropriate for wall construction. ANSI, UFAS or ADA compliance is subject to
the interpretation and requirements of the local code authority and is the
responsibility of the installer for verification.
TOILET WASTE CONNECTIONS
Units with Wall Waste Outlets are provided using a 5-1/2” Diameter Recessed
Gasket Flange and Floor Waste units will receive a 7-1/2” Diameter Recessed
Gasket Flange. The Stainless Steel Gasket Flange is welded in place to the
Toilet P-trap, and is fabricated to be flush with the back of the unit (wall
outlet) or flush with the bottom of the fixture (floor outlet). The depth of
the Recessed Gasket Flange is 1/2” deep. The Recessed Gasket Flange is
intended for installation and assembly with a common 3” or 4” Toilet Closet
Flange Fitting, Yoke Adapter or similar. The Recessed Gasket Flange provided
includes (2) 5/16” UNC Threaded Captive Nuts, which are on 6” centers. These
tapings allow for assembly of Closet Bolts and may assist to provide for the
Squeeze of the Gasket to seal the waste connection. Certain installation
conditions may not require using the tapings. Choice of the Gasket material is
up to the installer however, it is common for Neoprene or Felt Gaskets to be
used with Wall Waste Toilet units.
Please refer to the Link or QR code provided.
For Cleaning & Care Guide:
https://www.whitehallmfg.com/uploads/fileLibrary/9900-008-W01.pdf
TECHNICAL DIMENSIONS
WALL SUPPLY
TOP SUPPLY
NOTE: All dimensions are in Inches (mm)
- Toilet
- 1-1/2” NPT Female Wall Supply Flush Inlet Connection
- 1-1/2” NPT Male Top Supply Flush Inlet Connection
- Ligature Resistant Toilet Seat Cover
- Access Panel with Vandal Resistant Fasteners
- Wall Anchors: Provided by others to suit wall construction
- Flush Valve Shown for reference only and is not included. Refer to optional Flush Valve Access Panel and Cover for additional details
ROUGH-IN DIMENSIONS
IMPORTANT Ligature Resistant Toilets require specific Flush Valve model to
suit application for Supply Type (Concealed / Exposed), Flow Rate and ADA
Accessibility (when applicable). Refer to the following White Hall®
Accessories:
– Concealed Flush Valve Access Panel: Model WH2898 and WHD2898 for ADA
– Exposed Flush Valve Cover: WH2802-SLPT and WH2802-SLPT -ADA
WALL SUPPLY
TOP SUPPLY
*Note: Flush Valve Supply Inlet dimensions provided are for reference
only.
Dimensions shown will coordinate with Whitehall Manufacturing optional models
WH802-SLPT and WH2802-SLPT-ADA Top Supply Flush Valve covers.
- 5-1/2” Recessed Gasket Flange (Flush with back of fixture for connection to Closet Flange)
- 1-1/2” NPT Female Wall Supply Flush Inlet Connection
- 1” NPT Female Flush Valve Supply Inlet
- 5/8” Dia. Openings provided for Mounting to required Wall Anchors and/or Wall Backing.
INSTALLATION DETAILS
A. Position Mounting Channel [2] onto fixture side of Reinforced Wall locating
as indicated. Wall Anchors and Fasteners [3] are by others. See Detail A.
B. Place Toilet up against wall. Attach toilet housing to Mounting Channel [2]
using 1/4-20 Screws [4]. Detail B.
C. Remove Access Panel and Fasteners [7] make up toilet waste connection.
D. Install Flush Valve to fixture as required per manufacture’s
recommendations.
- Closet Flange (By Others)
- Wall Channel (Provided)
- Wall Mounting Hardware (By Others)
- 1/4-20 Screws
- Neoprene Gasket (By Others)
- 5-1/2” Dia. Recessed Gasket Flange (Provided)
- Access Panel and 1/4”-20 Fasteners
PLASTIC SEAT INSTALLATION
INSTALLATION INSTRUCTIONS:
Prior to installing, Verify if the following is Included:
Carriage Bolts [1], Tapered Nuts [2], Front Set Screw [3], and Toilet Seat
[4].
A. Partially install Front Set Screw [3] into the Mounting Tab [5] located at
the front of the Toilet Seat [4]. Set Screw [3] should not pass beyond
Mounting Tab [5].
B. Position the Toilet Seat [4] onto Toilet, and press down firmly.
C. Fasten the Toilet Seat [4] to the Toilet by using the Carriage Bolts [1] on
top of the Toilet Seat [4] and tighten by installing the Tapered Nuts [2] from
the underside of the Toilet rim.
D. With Toilet Seat [4] Fastened, pressed downward on Toilet Seat [4] and
tighten the Front Set Screw [3] until it firmly engages under the Flushing Rim
[6].
NOTE: If Toilet Seat has Hole Plugs, remove them prior to installing
Toilet.
SLOPING FLOORS:
When required for sloping floors, refer to detail to create a level pad for on-
floor Toilet Housing.
IMPORTANT:
Sloping floor detail is provided for reference only and should not be
considered as a recommendation by the fixture manufacturer. Installer assumes
all responsibility to alterations of site conditions and affected fixture
dimensions.
WHITEHALL MANUFACTURING • P.O. BOX 3527 • City of Industry, CA 91744-0527
U.S.A.
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web:
www.whitehallmfg.com
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:
1.800.591.9360
Technical Assistance E-mail:
Fieldservice@acorneng.com