OST 1U 19 Inch Rack Mount Shelf

Product Information

Product Overview
The 1U Rack Mount Shelf is a device used to mount and attach different modules and chassis to a standard 19-inch rack. The shelf provides multiple mounting holes and options to accommodate various module/chassis types. It also includes grounding posts to secure a grounding lug from the rack to the shelf.

Product Usage Instruction

Installation Procedure

Unpacking, Visual Inspection, and Inventory
Review the contents of the package and ensure that all necessary items are included.

Rack Mounting
Mount and attach the shelf to the standard 19-inch rack using appropriate rack mounting screws (not included). The rack should be appropriately earth grounded before powering the attached modules. Use NEBS earth grounding posts to secure a grounding lug from the rack to the shelf.

General Installation
Use the Mounting Hole Guide to determine the correct mounting holes for the module/chassis type. Align the module to the appropriate mounting holes starting at the bottom left corner of the shelf and moving left to right across the shelf. Use the appropriate plastic snap rivets to mount the module to the shelf by pressing the rivets through the top of the wall mount bracket until the rivet locks into place. Remove any rubber feet before installing the module/chassis to the shelf. Embedded cable tie-down slots secure the power cord(s) and data cable(s) to the shelf (cable ties not included). Grounding screws are available to attach an earth ground wire between the module and the shelf.

Installing iConverter, OmniConverter /SE and OmniConverter Extenders
Up to four iConverter wall mount or tabletop modules, and/or OmniConverter /SE, and/or OmniConverter PoE Extenders can be mounted on the shelf.

Installing iConverter 2-Module Chassis
Up to two iConverter 2-Module chassis can be mounted on the shelf. In order to mount the iConverter 2-Module Chassis to the shelf, the optional wall mount brackets (model 8249-0) must be installed on the chassis (not included).

Installing iConverter GM4 5-Port and 1-Module Chassis and OmniConverter /S
The shelf can accommodate iConverter GM4 5-Port and 1-Module Chassis, and OmniConverter /S.

Installing RuggedNet Switches and Extenders and OmniConverter Switches
Up to two RuggedNet switches or Extenders or OmniConverter Switches can be mounted on the shelf.

Note:
It is important to refer to the Mounting Hole Guide to ensure the correct mounting hole for each unit installed on the shelf.

PRODUCT OVERVIEW

The 1U 19” rack mount shelf (model 8260-0) accommodates iConverter® standalone media converters, iConverter 1-Module chassis, iConverter 2-Module chassis, OmniConverter® media converters and switches, RuggedNet® switches, FlexSwitch™ 2X4GT and iConverter GM4 5-Port, GM4 PoE/HPoE and XM5 Network Interface Devices.

INSTALLATION PROCEDURE

  1. Unpacking, Visual Inspection and Inventory
  2. Rack Mounting
  3. General Installation
  4. Installing iConverter, OmniConverter /SE and OmniConverter Extenders
  5. Installing iConverter 2-Module Chassis
  6. Installing iConverter GM4 5-Port and 1-Module Chassis and OmniConverter /S
  7. Installing RuggedNet Switches and Extenders and OmniConverter Switches

Unpacking, Visual Inspection and Inventory
Review the contents. The following items should be included:

  • 1U Rack Mount Shelf
  • 20 Small Plastic Snap Rivets (For mounting holes B, D, G & H)
  • User Manual
  • 20 Large Plastic Snap Rivets (For mounting holes A, C, F & J)

Rack Mounting
Mount and attach the shelf to the 19” standard rack using the appropriate rack mounting screws (not included). When rack-mounting the shelf, the rack should be appropriately earthgrounded before powering the attached modules. The shelf provides NEBS earth grounding posts to secure a grounding lug from the rack to the shelf. The shelf has multiple mounting holes to accommodate the different module/chassis options. Use the Mounting Hole Guide to determine the correct mounting hole for the each unit installed on the shelf.

Type

| Mounting Holes| Rivet| Shelf Capacity
---|---|---|---
A| B| C| D| F| G| H| J| Small| Large
iConverter Standalone Wall Mount Module, OmniConverter xPoE/SE and xPoE+/SE, and OmniConverter PoE Extender|

x

|  |  |  |  |  |  |  |  |

x

|

4

iConverter Standalone Tabletop Module w/Wall Mount Brackets (4381)|  | x|  | |  |  |  |  | x|  | 4
iConverter GM4 5-Port, OmniConverter /S, and OmniConverter 10G Multi-rate|  | | x|  |  |  |  |  |  | x| 3
iConverter GM4 PoE/HPoE|  |  |  |  | x|  |  |  |  | x| 2
iConverter XM5 and XM5-1G|  |  |  |  |  |  | x|  | x|  | 2
iConverter 1-Module Redundant Power Chassis w/Wall Mount Brackets (8249-0)|  | |  |  |  | x|  |  | x|  | 2
iConverter 1-Module and 2-Module Chassis w/Wall Mount Brackets (8249-0)|  |  | | x|  |  |  |  | x|  | 3
RuggedNet Switches and RuggedNet PoE Extender w/Wall Mount Bracket (8260-3), and OmniConverter Switches|  |  |  |  |  |  |  |

x

|  |

x

|

2

FlexSwitch 2X4GT|  |  | x|  |  |  |  |  |  | x| 2

General Installation
Use the Mounting Hole Guide to determine the correct mounting holes for the module/chassis type. Align the module to the appropriate mounting holes starting at the bottom left corner of the shelf and moving left to right across the shelf. Use the appropriate plastic snap rivets to mount the module to the shelf by pressing the rivets through the top of the wall mount bracket until the rivet locks into place. Remove any rubber feet before installing the module/chassis to the shelf.

Embedded cable tie down slots secure the power cord(s) and data cable(s) to the shelf (cable ties not included). Grounding screws are available to attach an earthground wire between the module and the shelf.

Installing iConverter, OmniConverter /SE and OmniConverter Extenders
Up to four iConverter wall mount or tabletop modules, and/or OmniConverter /SE, and/or OmniConverter PoE Extenders can be mounted on the shelf.

In order to mount the iConverter tabletop module to the shelf, the optional wall mount brackets (4381) must be installed on the module.

Installing iConverter 2-Module Chassis
Up to two iConverter 2-Module chassis can be mounted on the shelf. In order to mount the iConverter 2-Module Chassis to the shelf, the optional wall mount brackets (model 8249-0) must be installed on the chassis (not included).

NOTE:
Mounting the 2-Module chassis to the shelf requires 2U rack spacing.

Installing iConverter GM4 5-Port and 1-Module Chassis and OmniConverter /S
Up to three OmniConverter /S or 10G Multi-rate or iConverter GM4 5-Port or 1-Module Chassis can be mounted on the shelf. In order to mount the iConverter 1-Module Chassis to the shelf, the optional wall mount brackets (model 8249-0) must be installed on the chassis (not included).

Installing RuggedNet Switches and Extender, and OmniConverter Switches
Up to two RuggedNet switches or Extenders or OmniConverter Switches can be mounted on the shelf.

In order to mount a RuggedNet switch to the shelf, the optional wall mounting plate (model
8260-3) must be installed on the switch (not included).

General and Copyright Notice

This publication is protected by U.S. and international copyright laws. All rights reserved. The whole or any part of this publication may not be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means, manual, electric, electronic, electromagnetic, mechanical, chemical, optical or otherwise, without prior explicit written permission of Omnitron Systems Technology, Inc.

The following trademarks are owned by Omnitron Systems Technology, Inc.: FlexPointTM, FlexSwitchTM, iConverter®, miConverterTM, OmniConverter®, RuggedNet®, Omnitron Systems Technology, Inc.TM, OSTTM and the Omnitron logo. All other company or product names may be trademarks of their respective owners. The information contained in this publication is subject to change without notice. Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.

Warranty

This product is warranted to the original purchaser against defects in material and workmanship for a period of two (2) years from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by registering this product within ninety (90) days from the date of shipment at www.omnitron-systems.com/support. During the warranty period, Omnitron will, at its option, repair or replace a product that is proven to be defective with the same product or with a product with at least the same functionality. For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.

No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose. The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.

Environmental Notices

The equipment covered by this manual must be disposed of or recycled in accordance with the Waste Electrical and Electronic Equipment Directive (WEEE Directive) of the European Community directive 2012/19/EU on waste electrical and electronic equipment (WEEE) which, together with the RoHS Directive 2015/863/EU, for electrical and electronic equipment sold in the EU after July 2019. Such disposal must follow national legislation for IT and Telecommunication equipment in accordance with the WEEE directive: (a) Do not dispose waste equipment with unsorted municipal and household waste. (b) Collect equipment waste separately. (c) Return equipment using collection method agreed with Omnitron.

The equipment is marked with the WEEE symbol shown to indicate that it must be collected separately from other types of waste. In case of small items the symbol may be printed only on the packaging or in the user manual. If you have questions regarding the correct disposal of equipment go to www.omniton- systems.com/support or e-mail to Omnitron at intlinfo@omnitron-systems.com.

©2022 Omnitron Systems Technology, Inc.

Omnitron Systems Technology Inc.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals