OST iConverter 2GXM2 Standalone Module User Guide
- June 12, 2024
- OST
Table of Contents
iConverter® 2GXM2
Standalone Module Quick Start
Product Overview
The iConverter 2GXM2 Network Interface Device (NID) with integrated management
provides Gigabit Ethernet (1000BASE-X) SFP fiber-to-fiber media conversion.
The 2GXM2 has built-in Operation, Administration and Maintenance (OAM)
functionality enabling the 2GXM2 to operate as a managed demarcation point at
the customer premises and network edge, offering Quality of Service
capabilities.
The 2GXM2 supports IPv4 addressing, IP-Less protocol using the 802.3ah OAM
channel, SNMPv1/v2c/v3, Telnet and serial console port.
Managed Fiber Media Converter and Gigabit Ethernet NID (omnitron- systems.com).
DIP-Switches
DIP-Switch Bank 1
The location of the DIP-switches is shown in below. The functions of DIP-
switch Bank 1 are outlined in below.
Switch | Left (Factory Default) | Right |
---|---|---|
SW1 | AN: Fiber Port 1 Auto | Man: Fiber Port 1 Manual |
SW2 | AN: Fiber Port 2 Auto | Man: Fiber Port 2 Manual |
SW3 – SW5 | Reserved | Reserved |
SW6 – SW8 | See Link Mode Selection |
DIP-switch BANK 1 Definitions
SW1 – Fiber Port 1 Negotiation “AN/Man”
When this DIP-switch is in the Left “AN” position (factory default), the fiber
optic port automatically determines the pause modes of the connecting fiber
optic device. If the connecting fiber optic device cannot provide the proper
signal to indicate its own mode of operation, the DIP-switchshould be set to
the Right “Man” position. When Port 1 is set to the “Man” position, no
capabilities are advertised.
Gigabit fiber always operate in Full-Duplex mode.
NOTE: When Port 1 operates in Auto-Negotiationmode, the port advertises
for Pause. When the Fiber optic ports (Port 1 and Port 2) operates in
Manualmode, Pause is not advertised.
SW1 – Fiber Port 2 Negotiation “AN/Man”
When this DIP-switch is in the Left “AN” position (factory default), the fiber
optic port automatically determines the pause modes of the connecting fiber
optic device. If the connecting fiber optic device cannot provide the proper
signal to indicate its own mode of operation, the DIP-switchshould be set to
the Right “Man” position. When Port 2 is set to the “Man” position, no
capabilities are advertised.
Gigabit fiber always operate in Full-Duplex mode.
SW3, SW4 and SW5 – Reserved
These DIP-switches are for factory use only and mustalways remain in the Left
position (factory default).
SW6, SW7, SW8 – Link Modes
These three DIP-switches configure the link mode settings.
It is recommended to have link modes Left (default) during the initial
installation. After the circuit has been tested and operational, configure the
module for the desire mode.
For detailed information on the operation of the different Link Modes,
download the application note “iConverter Link Modes (omnitron-
systems.com)”.
SW6 | SW7 | SW8 | Link Mode Selection |
---|---|---|---|
Left | Left | Left | Link Segment (LS) (Factory Default) |
Right | Left | Left | Link Propagate (LP) |
Left | Right | Left | Remote Fault Detect + Link Segment (RFD + LS) |
Right | Right | Left | Remote Fault Detect + Link Propagate (RFD + LP) |
Left | Left | Right | Symmetrical Fault Detect (SFD) |
Right | Left | Right | Asymmetrical Link Propagate Port 1 to Port 2 (ALP P1-P2) |
Left | Right | Right | Asymmetrical Link Propagate Port 2 to Port 1 (ALP P2-P1) |
Right | Right | Right | Pass Remote Link Fault (PRLF) |
Link Modes
Software Controlled Switch Settings
Additional settings are available via software control.
The following software settings can be controlled via Serial Console/Telnet
Console, NetOutlook Management Software or other third-party SNMP-based
clients:
- DIP-switch Configuration
- Port 1 and Port 2 Configuration
- 802.1ad Q-in-Q, QoS and Port Access Control
- MIB statistics
- Bandwidth control (rate limiting)
- Configurable Link Fault Propagation modes
The module can be configured by attaching the serial port to a DB-9 serial
(RS-232) equipped computer with terminal emulation software such as ProComm or
Putty.
The Serial Console Port (DCE) is a mini DIN-6 female connector which can be
changed to a DB-9 connector with the included adapter. Attach the ends of a
serial cable to the serial port of the PC and the Serial Console Port of the
module. The port is a standard RS-232 asynchronous serial interface with the
following settings.
Bits Per Second | 57,600 |
---|---|
Stop Bits | 1 |
Data Bits | 8 |
Parity Hardware Flow Control | NONE |
The default password is public. | NONE |
When using Telnet or SNMP, the default IP address for the module is
192.168.1.220.
For more information on using and configuring the Advanced Features, register
for access to the Register (omnitron-systems.com)or the Omnitron Systems (omnitron-
systems.com).
Mounting and Cable Attachment
Caution: Use proper ESD protection to reduce the risk of damage to your
equipment.
a. The module is available as a standalone module with integrated wall-mount
brackets. Attach the unit to a wall, backboard or other flat surfaces. Make
sure the unit is placed in a safe, dry and secure location.
For AC models:
To power the unit using the AC/DC adapter, connect the AC/DC adapter to an AC
outlet. Then connect the barrel plug at the end of the wire on the AC/DC
adapter to the 2.5mm DC barrel connector (center-positive) on the unit.
Confirm that the unit has powered up properly by checking the power status LED
located on the front of the unit.
For DC Models:
To power the unit using a DC power source, prepare a power cable using a two
conductor insulated wire (not supplied) with 12AWG to 20AWG thickness. Cut the
power cable to the length required. Strip approximately 3/8 of an inch of
insulation from the power cable wires. Connect the power cables to the unit by
fastening the stripped ends to the DC power connector.
Connect the power wires to the DC power source. The Power LED should indicate
the presence of power.
WARNING: Note the wire colors used in making the positive and negative
connections. Use the same color assignment for the connection at the DC power
source.
NOTE: If mounting with a safety ground attachment, use the safety ground
screw at the rear of the unit.
b. Insert the SFP fiber transceivers into the SFP receptacles on the module.
NOTE: The release latch of the SFP transceiver must be in the closed (up)
position before insertion.
d. Connect an appropriate multimode or single-mode fiber cables to the fiber
ports of the installed module. It is important to ensure that the transmit
(TX) is attached to the receive side of the device at the other end and the
receive (RX) is attached to the transmit side. Single-fiber (SF) media
converter models operate in pairs. The TX wavelength must match the RX
wavelength at the other end and the RX wavelength must match the TX wavelength
at the other end.
NOTE: In order to support Remote OAM Management Mode, Port 1 of the 2GXM2 must be connected to the Port 1 on the 2GXM2 or link partner.
LED Indicators
LED | Color | Description |
---|---|---|
Power “PWR” | Green | OFF: No power applied or faulty |
ON: Module has power
P1 Activity “P1”| Green| OFF : No fiber link
ON : Fiber link is active
Blinking Green: Data activity
P2 Activity “P2”| Green| OFF: No fiber link
ON: Fiber link is active
Blinking Green: Data activity
Specifications
Description| iConverter 2GXM2
1000BASE-X Fiber to 1000BASE-X Fiber Media Converter and Network Interface
Device
---|---
Standard Compliances| IEEE 802.3, 802.1Q, 802.1p, 802.1ad, 802.3ah
RFC 2819 1kR4,;’,ON), 2863, 2131 MEF 9, 14, 21
Regulatory Compliances| Safety: UL, CE, NEBS Level 3, UKCA
EMI: FCC Class A
ACT: TAA, BAA, NDAA
Environmental| RoHS, WEEE, REACH
Management| IPv4, Telnet, SNMPv1, SNMPv2c, SNMPv3, Serial Console
Frame Size| Up to 10,240 bytes
Port Types| Fiber: 1000BASE-X (SFP)
Serial: RS-232 (Mini DIN-6 female)
Mini DIN-6 to DB-9 adapter included
Cable Types| Fiber: Multimode: 50/125pm, 62.5/125pm Single-mode: 9/125pm
Serial: RS-232, 22 to 24 AWG, 12 to 50 pF/ft
AC Power Requirements| AC Adapter:
100 – 240VAC/50 – 60Hz, 0.05A @ 120VAC (max)
DC Power Requirements| DC Input (Terminal):
+8 to +15VDC, 0.6A @ 9VDC 2-Pin Terminal (non-isolated)
DC Input (AC Adapter):
+8 to +15VDC, 0.6A @ 9VDC 2.5mm Barrel Connector
Dimensions W x D x H| Standalone: 3.1″ x 4.8″ x 1.0″ (78.7 mm x 121.9 mm
x 25.4 mm)
Standalone with Mounting Brackets: 3.8″ x 4.8″ x 1.0″ (96.5 mm x 121.9 mm x
25.4 mm)
Weight| 1.0 lb. (453.6 grams) – without AC Adapter
1.5 lbs. (680.4 grams) – with AC Adapter
Temperature| Commercial:
Wide:
Extended:
Storage:| 0 to 50°C
-40 to 60°C
-40 to 75°C
-40 to 80°C
Humidity| 5 to 95% (non-condensing)
Altitude| -100m to 4,000m
MTBF (hrs)| 540,000 – Module
250,000 – Module with US Adapter
100,000 – Module with Universal Adapter
Warranty| Lifetime warranty and
24/7/365 free Technical Support
General and Copyright Notice
This publication is protected by U.S. and international copyright laws. All
rights reserved. The whole or any part of this publication may not be
reproduced, stored in a retrieval system, translated, transcribed, or
transmitted, in any form, or by any means, manual, electric, electronic,
electromagnetic, mechanical, chemical, optical or otherwise, without prior
explicit written permission of Omnitron Systems Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.:
FlexPointTM , FlexSwitchTM , iConverter® , miConverterTM, NetOutlook® ,
OmniLight® , OmniConverter® , RuggedNet®, Omnitron Systems Technology, Inc.
TM, OSTTMand he Omnitron logo.
All other company or product names may be trademarks of their respective
owners.
The information contained in this publication is subject to change without
notice. Omnitron Systems Technology, Inc. is not responsible for any
inadvertent errors.
Warranty
This product is warranted to the original purchaser (Buyer) against defects in
material and workmanship for a period of two (2) years from the date of
shipment. A lifetime warranty may be obtained by the original purchaser by
registering this product at www.omnitron-systems.com/ support within ninety (90) days from the date of shipment.
During the warranty period, Omnitron will, at its option, repair or replace a
product which is proven to be defective with the same product or with a
product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated
facility, at Buyer’s expense. Omnitron will pay the shipping charge to return
the product to Buyer’s designated US address using Omnitron’s standard
shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to product malfunctions resulting from
improper or inadequate use and/or maintenance of the equipment by Buyer,
Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized
modifications or tampering with equipment (including removal of equipment
cover by personnel not specifically authorized and certified by Omnitron), or
misuse, or operating outside the environmental specification of the product
(including but not limited to voltage, ambient temperature, radiation, unusual
dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the
implied warranties of merchantability and fitness for any particular purpose.
The remedies provided herein are the Buyer’s sole and exclusive remedies.
Omnitron shall not be liable for any direct, indirect, special, incidental, or
consequential damages, whether based on contract, tort, or any legal theory.
Environmental Notices
The equipment covered by this manual must be disposed of or recycled in accordance with the Waste Electrical and Electronic Equipment Directive (WEEE Directive) of the European Community directive 2012/19/EU on waste electrical and electronic equipment (WEEE) which, together with the RoHS Directive 2015/863/EU, for electrical and electronic equipment sold in the EU after July 2019. Such disposal must follow national legislation for IT and Telecommunication equipment in accordance with the WEEE directive: (a) Do not dispose waste equipment with unsorted municipal and household waste. (b) Collect equipment waste separately. (c) Return equipment using collection method agreed with Omnitron.
The equipment is marked with the WEEE symbol shown to indicate that it must be collected separately from other types of waste. In case of small items the symbol may be printed only on the packaging or in the user manual. If you have questions regarding the correct disposal of equipment go to www.omniton- systems.com/support or e-mail to Omnitron at intlinfo@omnitronsystems.com.
Safety Warnings and Cautions
ATTENTION: Observe precautions for handling electrostatic discharge
sensitive devices.
WARNING: Potential damage to equipment and personal injury.
WARNING: Risk of electrical shock.
Customer Support Information
Phone: 949-250-6510
Fax: 949-250-6514
Address: Omnitron Systems Technology, Inc.
38 Tesla
Irvine, CA 92618, USA
Email:support@omnitron-systems.com
URL:www.omnitron-systems.com
040-8980N-002D 4/23
Documents / Resources
| OST
iConverter 2GXM2 Standalone
Module
[pdf] User Guide
8980NQS-SA-D, iConverter 2GXM2 Standalone Module, iConverter 2GXM2, Standalone
Module, Module
---|---
References
- Media Converters, NIDs, T1 and CWDM Multiplexers
- Omnitron Systems | Making Networks Reliable Since 1992
- Register
- iConverter Link Modes
- Managed Fiber Media Converter and Gigabit Ethernet NID
- Omnitron Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>