PULiTE CB Series Horizontal Centrifugal Pump Instruction Manual

October 30, 2023
PULiTE

PULiTE CB Series Horizontal Centrifugal Pump

Disassembly of shaft seal

Necessary tools: hexagon, Phillips, flat head screwdriver, box wrench, universal pliers

  • Step1: use hexagon wrench to take out the screw of suction base
  • Step2: take out the suction base
  • Step3: use Phillips screwdriver to take out the screw of fan cover,and take out the fan coverPULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-3
  • Step4: use flat head screwdriver to take out the fan And take out the fan
  • Step5: use universal pliers to grip the end of motor spindlePULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-4
  • Step6: grasp the universal pliers, use box wrench to take out the lock nut
  • Step7: take out the sleevePULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-5
  • Step8: take out the impeller
  • Step9: take out the chamberPULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-6
  • Step10: take out the sleeve
  • Step11: take out the chamberPULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-7
  • Step12: take out the spring
  • Step13: take out the O-ring, rotation of the ring, fixed ring,Disassembly completePULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-8

Assembly of shaft seal manual

Necessary tools: hexagon, Phillips, flat head screwdriver, box wrench, universal pliers

  • Step1: put the fixed ring, rotation of the ring, O-ring in it
  • Step2: put the spring in it
  • Step3: put the chamber in itPULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-11
  • Step4: put the impeller in it and put the sleeve
  • Step5: put the chamber in itPULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-12
  • Step6: put the impeller in it
  • Step7: put the sleeve in itPULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-13
  • Step8: use universal pliers to grip the end of motor spindle
  • Step9: put the lock nut in it, grasp the universal pliers, use box wrench lock the lock nutPULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-14
  • Step10: use hammer to beat the fan in it
  • Step11: use Phillips screwdriver to lock the screw of fan coverPULiTE-CB-Series-Horizontal-Centrifugal-Pump-FIG-15
  • Step12: use hexagon wrench to lock the suction base Assembly complete

PULITE ENTERPRISE CO.,LTD. NO.33-5,Yongchun Rd., Nantun Dist. Taichung City 408015,Taiwan(R.O,C)