JFA 40A X-Line Power Supply and Charger Instruction Manual
- October 30, 2023
- JFA
Table of Contents
- JFA 40A X-Line Power Supply and Charger
- PRODUCT INFORMATION
- USAGE INSTRUCTIONS
- PRESENTATION
- MODES OF OPERATIONS AND FUNCTIONS
- MAIN FEATURES
- INSTALLATION AND CONNECTIONS
- OPERATING MODES AND FUNCTIONS
- CONSUMPTION
- TECHNICAL SPECIFICATIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
JFA 40A X-Line Power Supply and Charger
PRODUCT INFORMATION
PRESENTATION
The X-Line Sources and Chargers are high-power supplies that come in super
compact format SLIM. They are available in 40A, 60A, 70A, 120A, 150A, and 200A
and can be used to power and charge automotive batteries. They are designed
for heavy use and can provide maximum power for an extended period of time
while keeping the sound on and charging the batteries. The X-Line Sources and
Chargers also have an exclusive X-LINE FUNCTION.
MODES OF OPERATIONS AND FUNCTIONS
- PERFORMANCE X-LINE FUNCTION: Unique to X-LINE chargers, it raises battery bank voltage to up to 15.2V for 30 seconds, allowing amplifiers to deliver maximum performance.
- INTELLIGENCE AUTO SCI MODE: STORM Sources have auto sci operating mode, ideal for use when the system is turned on and the sound takes power from the batteries and the source or when a quick charge is required on the batteries. In this mode, the STORM Source will maintain maximum output power (14.4V) whenever requested and will automatically enter the PULSED SCI system (SMART CHARGE SYSTEM) when the batteries are charged, remaining into fluctuation.
- SOURCE MODE – Fixed Output Voltage: X-LINE Sources allow the user to digitally choose between 6 voltage values at the source output (12.6V / 13.0V / 13.4V / 13.8V / 14.0V / 14.4V). This mode is ideal for battery-free systems, allowing you to power the amplifier or other devices with a stable voltage.
- BATTERY CHECK-UP – Accumulated Charge Meter: The STORM Sources display, in addition to working such as voltmeter and ammeter, informs the user how much cargo was accumulated by the battery during the charging cycle, letting you know if the battery is still in good working order.
- COMFORT SMART COOLER: X-LINE sources feature an intelligent ventilation system with dynamic PWM control. When the source is turned on, the fan initiates a gradual acceleration, reduces the rotation to the appropriate value, and adjusts to the source’s need. There is also a decrease in noise level, maintaining cooling and increasing the life of fans.
USAGE INSTRUCTIONS
- Before use, ensure that the X-Line Sources and Chargers are compatible with your automotive battery.
- Connect the X-Line Sources and Chargers to a power supply or battery charger using the provided cables.
- Choose the appropriate mode of operation based on your usage needs:
- PERFORMANCE X-LINE FUNCTION: Use this mode when you need to amplify sound for a short period of time.
- INTELLIGENCE AUTO SCI MODE: Use this mode when your system is turned on and the sound takes power from the batteries and the source or when you require quick battery charging.
- SOURCE MODE – Fixed Output Voltage: Use this mode when you need to power an amplifier or other devices with a stable voltage.
- If using the STORM Source, check the accumulated charge meter to ensure that the battery is still in good working order.
- Ensure that the X-Line Sources and Chargers are properly ventilated using the COMFORT SMART COOLER.
PRESENTATION
The X-Line Sources and Chargers of 40A, 60A, 70A, 120A, 150A and 200A are high-power supplies, in super compact format “SLIM”, which allow to power and charge automotive batteries. They provide a maximum current of 40A, 60A, 70A, 120A, 150A and 200A at their output, respectively, and operate in 3 intelligent modes that manage battery charging. In addition, the line has the exclusive X-LIINE FUNCTION. They are designed for heavy use, being able to provide maximum power for an extended period of time, keeping the sound on and charging the batteries. Its super compact “SLIM” format is ideal for use in any project. X-Line Sources and Chargers o er performance, INTELLIGENCE, DIAGNOSTIC functions and COMFORT items with the best design. They were designed and developed to be the most complete product on the market until then.
MODES OF OPERATIONS AND FUNCTIONS
PERFORMANCE
X-LINE FUNCTION:
Unique to X-LINE chargers, it raises battery bank voltage to up to 15.2V for
30 seconds, allowing amplificators to deliver maximum performance.
INTELLIGENCE
AUTO SCI MODE:
STORM Sources have auto sci operating mode, ideal for use when the system is
turned on and the sound takes power from the batteries and the source or when
a quick charge is required on the batteries.
In this mode, the STORM Source will maintain maximum output power (14.4V)
whenever requested, and will automatically enter the PULSED SCI system (SMART
CHARGE SYSTEM) when the batteries are charged, remaining into flutuation.
SLOW CHARGE MODE:
X-Line Sources have SLOW BATTERY charging mode, charging them in 3 phases
(LIFTING, ABSORPTION, EQUALIZATION) indicated on the CONTROL PANEL by 3 LEDs.
This function is ideal for recharging low-charge batteries and the sound
system turned o . When using the SLOW LOAD, the battery is charged at 100%
capacity and without su ering heating, as its smart charge curve is adjusted
to the capacity of the battery or the Batteries Installed. You get a maximum e
iciency in upload without Wear. Right Extend a life useful of battery beyond
from enable still more load.
During phase 1 (LIFTING) the battery current is limited to a maximum of 20% of the current of the previously configured battery bank; which gradually increases the voltage of the battery cells without heating or overloading. This phase has 6 steps, which are indicated by the firing frequency of LED 1 (ELEVATION), from 1 to 6Hz. When LED 1 (ELEVATION) lights up constantly, it means that this phase has already been performed. After the battery voltage is raised to 14.4V, the source automatically enters phase 2 (ABSORPTION). In phase 2 (ABSORPTION),the voltage remains constant at 14.4V while the battery absorbs charge, until the current reaches 4% of the bank value, previously configured, triggering LED 2 (ABSORPTION) constantly and automatically moving to phase 3 (EQUALIZATION). In phase 3 (EQUALIZATION), the voltage is reduced to 13.8V with pulses of 14.4V every 5 minutes. The battery is charged at its maximum capacity, because the equalization is done pulsatively.
SOURCE MODE – Fixed Output Voltage:
X-LINE Sources allow the user to digitally choose between 6 voltage values at
the source output (12.6V / 13.0V / 13.4V / 13.8V / 14.0V / 14.4V). This mode
is ideal for battery-free systems, allowing you to power the amplifier or other
devices with a stable voltage.
DIAGNOSIS
CCA METER – Cold Start Current:
Função exclusiva das Fontes STORM, a medição de CCA – Corrente de Partida a
Frio (Cold Cranking Ampere) – permite realizar uma análise da bateria em
apenas 10 segundos, fornecendo o valor de CCA da bateria em amperes, que pode
ser comparado com o CCA disponível no rótulo da bateria ou com medições
anteriores. A função mede também a resistência interna (Ri) em mΩ (miliOhm) e
a porcentagem comparativa da carga em relação a uma bateria nova.
BATTERY CHECK-UP – Accumulated Charge Meter:
The STORM Sources display, in addition to working such as voltmeter and
ammeter, informs the user how much cargo was accumulated by the battery during
the charging cycle, letting you know if the battery is still in good working
order.
COMFORT
SMART COOLER:
X-LINE sources feature an intelligent ventilation system with dynamic PWM
control. When the source is turned on, the fan initiates a gradual
acceleration, reduces the rotation to the appropriate value, and adjusts to
the source’s need. There is also a decrease in noise level, maintaining
cooling and increasing the life of fans.
SLIM FORMAT:
With the highest power density, X-LINE Fonts have robust, modern and super
compact design, taking up the smallest space in automotive sound design, which
makes them ideal in any project.
MAIN FEATURES
-
Control panel: Displays all source information and allows you to configure all functions;
-
Ventilation: Forced ventilation inlet from the source (do not block);
-
DC connector protection cover: Protege as conexões de saída da fonte;
-
DC output connector: Connects the battery terminals to the bus or equipment to be powered. Always check the correct connection polarity;
-
Fixation points: Robust system, allowing to be firmemente fixados by the metal chassis;
-
AC Connection: Connection of the Source to the power grid. Use compatible connection socket and do not use adapters and/or line machines;
-
Output from Ventilation: Output ventilation of the Source. Do not obstruct.
DASHBOARD FROM CONTROL -
LED that indicates the voltage parameter VOLTAGE, CURRENT or BATTERY CHECK-UP (2 LEDS on);
-
VOLTAGE, CURRENT and BATTERY CHECK-UP readings selector key;
-
Selector switch of SLOW LOAD, AUTO SCI e OUTPUT VOLTAGE;
-
LEDs that indicate SLOW LOAD, AUTO SCI and OUTPUT VOLTAGE;
-
BATTERY capacity selector switch (when in SLOW CHARGE mode), VOLTAGE of the output (when in VOLTAGE OUTPUT mode) or triggering of the X-LINE function (press for 2 seconds);
-
BATTERY CHARGED LED indicator;
-
Indicator LEDs of the 3 loading phases of SLOW LOAD mode;
-
Voltage/current indicator display or hour ampere counter.
INSTALLATION AND CONNECTIONS
X-LINE sources have a robust fixation system, allowing them to be firmly fixed by the metal chassis, giving greater resistance and safety in the installation (fig. 1). To remove the protective cover from the DC connectors, pull it up by exposing the connecting screws to the output cables (fig. 2).
Each Source 40A, 60A, 70A, 120A, 150A and 200A can power about 2,000, 3,000, 3,500, 6,000, 7,500 and 10,000 Wrms of sound playing respectively, provided that a parallel battery is used to supply the peak consumption. When connecting to the batteries, observe the correct polarity of the connection and use the appropriate cable gauge, according to the MINIMUM GAUGE table OF THE CABLES FOR CONNECTION (see page 11). In battery-powered systems, the source should always be connected to the battery and the battery to the amplificators (the connection point should always be made in the battery post).
You can use as many Fonts (40A, 60A, 70A, 120A, 150A and 200A) that are required to power the sound, with reference that each one keeps about 2,000, 3,000, 3,500, 6,000, 7,500 and 10,000 Wrms of sound playing respectively.
Another important point to note is that, operating in parallel, the sources must be in the same OPERATING MODE, example:
- AUTO SCI MODE: All sources must be in SCI.
- OUTPUT VOLTAGE MODE: All sources must have the same output voltage.
- SLOW LOAD MODE: Only one source must be on, the others off.
OPERATING MODES AND FUNCTIONS
MODE (REDLINE) SLOW LOAD – Smart Slow Load
To use Smart Slow Load mode, press the SELECTOR MODE until the LED indicative
Of LOAD SLOW Light. Press a key SELECTOR BATTERY e Select a capacity, in
amperes, of the battery to be charged. Upon arriving in 999, the counter
returns to the first value.
If your battery does not fit the options, use the nearest smallest value, and in case there is more than one battery in parallel in the system, add the amperage of all and select the capacity that most closely closes to that of the seat.
The available options are:
IMPORTANT:
If there are more sources in parallel in the system, use only one of the
sources in slow load mode and keep the other ones o .
SCI MODE – Smart Fast Charge
To use AUTO SCI mode, press the MODE SELECTOR switch until the Auto SCI (Smart
Charging System) LED lights up. This mode allows the source output to operate
at 14.4V when the system requests more (sound on playing or in a battery
charge situation). In fluctuation, it operates with the tension from output in
Cycles from 13.8V during 5 minutes e 14.4V during 10 Seconds.
THE AUTO SCI allows the battery to absorb a greater amount of charge and prevent excessive elevation of the potential of the plates, a chemical phenomenon caused by load stress (electrolysis), increasing the life and e iciency of the batteries.
OUTPUT VOLTAGE MODE (Fixed Source Mode)
To use in FIXED OUTPUT VOLTAGE mode, press the SELECTOR switch MODE until the
LED VOLTAGE OUTPUT turns on.
Immediately after, press the VOLTAGE SELECTOR switch and select the desired output voltage. The options healthy:
X-LINE FUNCTION
To select the X-LINE function, simply hold down the BATTERY /VOLTAGE/X-LINE
SELECTOR switch for 2 seconds. When triggered, the display will show the SPL
inscription flashing for 30 seconds. After this time, the display displays the
OFF subscription and the font returns to its previous operating condition.
To disable the function, before time runs out, simply press the key again BATTERY/VOLTAGE/STORM SELECTOR while the function is running. The display displays the inscription OFF e a source Returns à its condition from operation previous.
CCA METER FUNCTION (Cold Start Current Meter)
To perform CCA measurement, simultaneously press the SELECTOR READING and
SELECTOR MODE keys.
When the CCA METER function is activated, the STORM Source disconnects from the AC power grid, disconnects the fan, and starts the battery test. When the display displays the CCA-BATXXX information, press the BATTERY SELECTOR switch to select the battery capacity to be tested. During this process, the display displays the word CCA flashing. After 10 seconds, the display displays the CCAXXX information, which can range between 20A and 999A, with the CCA value obtained in the reading and RiXXXX (internal battery resistance) in mΩ the percentage of battery charge is displayed in comparison to a new battery (selected at the beginning of the test). This function can be used to test a battery bank that is within the maximum source specifications (for parallel connection, add CCA of each battery) however, it is more indicated that the test is done on individual batteries. For proper operation, use 50mm2 x 30cm cables for 200A and 150A sources; 35mm2 x 30cm for 120A sources; and 16mm2 x 30cm for 70A, 60A and 40A sources; and make sure that the supply terminals are correct ly so in the terminals to the battery terminals.
BATTERY CHECK-UP FUNCTION (Cumulative Charge Meter)
- To perform a BATTERY CHECK-UP, proceed:
- The battery must be discharged to approximately 11V voltage.
- Turn on the source, press the key SELECTOR READING until the mode BATTERY CHECK-UP is active (VOLTAGE and CURRENT LEDS ON). To reset the counter, hold down the key SELECTOR READING by 5 Seconds.
Connect the battery to the charger and wait the indication light BATTERY LOADED (charging time may vary depending on battery capacity and the source used). Read in display a quantity from Amps than a battery Accumulated during o process from load. Verify the value obtained is close to the amount of amperes specified by the battery manufacturer (e.g. If the battery charged is 60A, the obtained value should be close to 60A). The lower, in relation to the value indicated by the manufacturer, the worse the battery status. If a battery bank is used in parallel, add the currents of the seat batteries.
Note:
When the meter reaches 999 it must be reset to continue reading the
accumulated charge on the battery.
VOLTAGE READING
The X-LINE Source display allows you to view the output voltage (in Volts)
that is being applied at that time to the system. To access this voltage
value, press the SELECTOR READING switch until the VOLTAGE INDICATOR LED
lights up.
CURRENT READING
The X-LINE Source display allows you to view the output current (in amperes)
that is being applied at that time to the system. To access this current
value, press the SELECTOR READING switch until the CURRENT INDICATOR LED
lights up.
CONSUMPTION
CONSUMPTION – MINIMUM CABLE GAUGE – POWER
Model X-LINE| Max.
Consumption
entry
| Network 127Vac| Network 220Vac| AC input cable (up to 10 meters)| DC output
cable (up to 1 meter)| Max power. Output
---|---|---|---|---|---|---
40A| 600W| 5A| 3A| 2,5mm2| 6mm2| 40A
60A| 900W| 7A| 4A| 4mm2| 10mm2| 60A
70A| 1050W| 8A| 5A| 4mm2| 16mm2| 70A
120A| 1800W| 15A| 8A| 4mm2| 25mm2| 120A
150A| 2250W| 18A| 10A| 6mm2| 35mm2| 150A
200A| 3000W| 24A| 14A| 6mm2| 50mm2| 200A
TECHNICAL SPECIFICATIONS
X-LINE 40A
AC input| 90 to 140Vac / 170 to 240Vac (Automatic Bi-volt)
Consumption with maximum load| 600W
Maximum output current| 40 Amperes
Selectable output voltage| 12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
SCI – Intelligent charging system| 13,8 / 14,4 cyclic
3-phase slow load system – Customizable| Elevation /Absorption/ Equalization
Smart cooler – Smart ventilation system| Dynamic control by PWM
Precision voltmeter / ammeter| 99% / 96%
Protections| Excesso de carga / Curto na saída / Temperatura
Dimensions L x A x P (mm)| 259 x 151 x 58
Weight Kg| 1,420
X-LINE 60A
AC input| 90 to 140Vac / 170 to 240Vac (Automatic Bi-volt)
Consumption with maximum load| 900W
Maximum output current| 60 Amperes
Selectable output voltage| 12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
SCI – Intelligent charging system| 13,8 / 14,4 cyclic
3-phase slow load system – Customizable| Elevation /Absorption/ Equalization
Smart cooler – Smart ventilation system| Dynamic control by PWM
Precision voltmeter / ammeter| 99% / 96%
Protections| Overload / Short at output / Temperature
Dimensions L x A x P (mm)| 259 x 151 x 58
Weight Kg| 1,440
X-LINE 70A
AC input| 90 a 140Vac / 170 a 240Vac (Automatic Bi-volt)
Consumption with maximum load| 1050W
Maximum output current| 70 Amperes
Selectable output voltage| 12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
SCI – Intelligent charging system| 13,8 / 14,4 cyclic
3-phase slow load system – Customizable| Elevation /Absorption/ Equalization
Smart cooler – Smart ventilation system| Dynamic control by PWM
Precision voltmeter / ammeter| 99% / 96%
Protections| Overload / Short at output / Temperature
Dimensions L x A x P (mm)| 259 x 151 x 58
Weight Kg| 1,440
X-LINE 120A
AC input| 90 a 140Vac / 170 a 240Vac (Automatic Bi-volt)
Consumption with maximum load| 1800W
Maximum output current| 120 Amperes
Selectable output voltage| 12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
SCI – Intelligent charging system| 13,8 / 14,4 cyclic
3-phase slow load system – Customizable| Elevation /Absorption/ Equalization
Smart cooler – Smart ventilation system| Dynamic control by PWM
Precision voltmeter / ammeter| 99% / 96%
Protections| Overload / Short at output / Temperature
Dimensions L x A x P (mm)| 279 x 163 x 86
Weight Kg| 2,050
X-LINE 150A
AC input| 90 a 140Vac / 170 a 240Vac (Automatic Bi-volt)
Consumption with maximum load| 2250W
Maximum output current| 150 Amperes
Selectable output voltage| 12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
SCI – Intelligent charging system| 13,8 / 14,4 cyclic
3-phase slow load system – Customizable| Elevation /Absorption/ Equalization
Smart cooler – Smart ventilation system| Dynamic control by PWM
Precision voltmeter / ammeter| 99% / 96%
Protections| Overload / Short at output / Temperature
Dimensions L x A x P (mm)| 289 x 172 x 95
Weight Kg| 2,250
X-LINE 200A
AC input| 90 a 140Vac / 170 a 240Vac (Automatic Bi-volt)
Consumption with maximum load| 3000W
Maximum output current| 200 Amperes
Selectable output voltage| 12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
SCI – Intelligent charging system| 13,8 / 14,4 cyclic
3-phase slow load system – Customizable| Elevation /Absorption/ Equalization
Smart cooler – Smart ventilation system| Dynamic control by PWM
Precision voltmeter / ammeter| 99% / 96%
Protections| Overload / Short at output / Temperature
Dimensions L x A x P (mm)| 317 x 172 x 95
Weight Kg| 2,650
X-LINE 200A MONO
AC input| 170 a 240Vac (mono-volt)
Consumption with maximum load| 3000W
Maximum output current| 200 Amperes
Selectable output voltage| 12,6V / 13,0V / 13,4V / 13,8V / 14,0V / 14,4V
SCI – Intelligent charging system| 13,8 / 14,4 cyclic
3-phase slow load system – Customizable| Elevation /Absorption/ Equalization
Smart cooler – Smart ventilation system| Dynamic control by PWM
Precision voltmeter / ammeter| 99% / 96%
Protections| Overload / Short at output / Temperature
Dimensions L x A x P (mm)| 317 x 172 x 95
Weight Kg| 2,640
Contact Information
- Website: jfaeletronicos.com.
- Instagram: @jfaeletronicos
- Facebook: jfaeletronicos
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>