VS5HI Sequencer Voltmeter

CONGRATULATIONS!
You have just purchased a product with the quality JFA Electronics, which was developed with technology advanced and unique design.
Please read the operating instructions and installation in this guide.

PRESENTATION

The voltmeter and sequencer VS5HI JFA was developed to perform three functions in the same equipment they are:

  • Low voltage voltmeter to 17V;
  • High-voltage voltmeter up to 500V;
  • Remote command sequencer.

DESCRIPTION

JFA ELETRONICOS VS5HI Sequencer Voltmeter -
DESCRIPTION

  1. Selector functions: HOL (Hold) – LIG (ON) – OFF
  2. Voltmeter selector: LOW – HIGH;
  3. Five remote control outputs;
  4. High input voltage (battery bank);
  5. GND;
  6. Remote control input;
  7. Low input voltage (+12V).

INSTALLATION EXAMPLE

JFA ELETRONICOS VS5HI Sequencer Voltmeter - INSTALLATION
EXAMPLE

FUNCTIONS

JFA ELETRONICOS VS5HI Sequencer Voltmeter - FUNCTIONS

FUNCTION PLAYER OUTS VOLTMETER
HOL (Hold) On On Stores lower voltage
Off Off
LIG (ON) On On On
Off Off
DES On On On
Off Off Off

Recommendations and comments

  1. Due to the risk of shock high voltage, look for a specialized service to perform the installation of this equipment.
  2. Do not use cables with damaged insulation cover for this installation. Make sure the cables are not being pressed at any point of the installation.

FUNCTION
VOLTMETER

Low Voltage Measurement Maximum 17V
High voltage measuring Maximum 500V

SEQUENCER REMOTE CONTROL

Current at output 150 mA
Low voltage protection <9,5V
against high voltage protection > 17,0V
DIMENSIONS IN MM (WxHxD) 10x57x17