Product Information
The Ultra-Thin Wafer Gimbal LED Round Module – Switchable is a ceiling mounted fixture that comes in two models: WF4 ADJ SWW5 90CRI and WF6 ADJ SWW5 90CRI. The product has switchable color temperature, which means it can be adjusted to 27K, 30K, 35K, 40K, or 50K. The WF4 model replaces incandescent 65W lamps while the WF6 model replaces incandescent 75W lamps. The product is patented under U.S. Patent No. 10,681,784.
Product Usage Instructions
- Before beginning the installation, make sure all power is off. It is recommended to shut off power in the breaker box to areas where downlights are to be installed.
- Read the instructions carefully and save them for future reference.
- Choose the appropriate model (WF4 or WF6) based on your requirements.
- Install the product on the ceiling using the appropriate mounting locations/methods.
- Connect the wires using wire connectors.
- Adjust the color temperature according to your preferences using the switchable feature.
- Make sure to follow all safety instructions to avoid the risk of electric shock, injury, burn, fire, or product damage.
- If you encounter any problems with interference to electronic devices, move the device away from the luminaire or plug it into a different outlet.
INSTALLATION INSTRUCTIONS
Ultra-Thin Wafer Gimbal LED Round Module – Switchable
Model Number
WF4 ADJ SWW5 90CRI, WF6 ADJ SWW5 90CRI
SWITCHABLE COLOR TEMPERATURE: 27K-30K-35K-40K-50K
This Fixture is Ceiling Mounted
Round 4” and 6” round Gimbal fixture with up to 20 degree tilt and consist of integral LEDs with switchable CCT feature. Select from either 27K, 30K, 35K, 40K, or 50K option (light color need to be selected before installing fixture). Isolated external driver factory installed inside remote driver box. LED module comes as complete unit consisting of 2 parts: The LED module and remote driver box (with CCT switchable button). One remote driver box for each fixture is required. Pot light housing NOT required even for insulated ceilings and can be direct fit in ceiling hole. LED fixture and remote driver box are TYPE IC rated.
- 4” replaces incandescent 65W Lamp
- 6” replaces incandescent 75W Lamp
U.S. Patent No. 10,681,784
Protect yourself. Before
installing, read these instructions carefully and save them for future
reference.
Date Installed:____
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Never connect an LED product to an unapproved dimmer pack. Contact ABL directly for any dimmers not specifically recommended for the product.
- Unless individual product specifications deem otherwise: Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Maximum ambient temperature is 90°C. Do not operate fixture at temperatures higher than this.
- Unless individual product specifications deem otherwise: Never mount in places where fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- There are no user serviceable parts inside the unit. Do not rewire, reconfigure, or modify the unit or attempt any repairs yourself. Additionally, field replacement of the LED assembly or lamps is not allowed by UL standards at this time. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative.
All luminaires that contain electronic devices that generate frequencies above
9kHz from any component within the luminaire comply with one of the following
Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- (1) This device may not cause harmful interference
- (2) This device must accept any interference received, including interference that may cause undesired operation.
This device complies with Part 18 of the FCC Rules but may cause interference
with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem move the device away from the luminaire or
plug into a different outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications
equipment or other critical navigation or communications equipment operating
between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
OUR BRANDS
Indoor/Outdoor: Juno Lighting, Lithonia Lighting, Carandini, Holophane, RELOC
Indoor Lighting: Gotham, Mark Architectural Lighting, Peerless, Renaissance
Lighting, Winona Lighting
Outdoor Lighting: American Electric Lighting, Antique Street Lamps, Hydrel,
Tersen Controls: DARK TO LIGHT, Lighting Control & Design, ROAM, Sensor
Switch, Synergy Acuity Brands Lighting, Inc. assumes no responsibility for
claims arising out of improper or careless installation or handling of its
products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
STEP-BY-STEP GUIDE
Note: Before beginning the installation, make sure all power is off, shutting power off in breaker box to areas where downlights are to be installed is recommended.
Required Tools (not included): Safety glasses and gloves.
- Double check and measure the ceiling hole. Make sure it is the correct size for outside rim of the luminaire to cover the hole while still allowing the back of luminaire to sink in to the ceiling and springs to hold firmly.
- Remove existing retrofit can if present or move it out of the way since it will not be needed for installation.
- If new hole is to be cut, use provided hole template. Place template over the desired location. Trace the outer ring with a pen or pencil (not included). Cut the opening with a saw (not included). (Figure 1)
- Open the cover of the remote driver box. Push and remove one of the knockouts on the side plate.
- Locate power supply leads from remote driver box and connect to power source using wago connectors (provided).
- Connect black wire to live wire, white wire to neutral wire, and green wire with ground (as shown) and secure using wago connector. Close the cover of the box. (Figure 2)
- Connect the remote driver box to the light fixture and tighten the nut connector by hand. Arrow on the male and female parts of the connector between the driver and fixture cable should match. (Figure 3)
- Use switch on the driver box (CCT option need to be selected before fixture installation) to select appropriate light color (27K, 30K, 35K, 40K, or 50K). (Figure 4)
- Place remote driver box thru the cut-out hole.
- MUST follow local electric code for rigid attachment and placement of the remote driver box. (Figure 5)
- Optional Mounting Kits: Instruction sheet for new construction plate and joist bar kit can be found at www.acuitybrands.com
- Pull the spring clip on the fixture up and through the ceiling hole and place module in the hole making sure the spring clips are holding securely. (Figure 6)
- Turn the power back on. If the module doesn’t illuminate within 5 seconds, turn power off, carefully remove the module and double check all wiring and replace. (Figure 7)
WARNING:
- DO NOT PLACE YOUR HAND UNDERNEATH SPRING CLIP DURING REMOVAL PROCESS. SNAPPING OF THE CLIPS CAN CAUSE INJURIES TO THE HAND. (Figure 8)
- DO NOT USE ANY OTHER DRIVER EXCEPT JUNO LIGHTING DRIVER THAT IS INCLUDED WITH THE FIXTURE.
- DO NOT CONNECT MULTIPLE MODULES TO ONE DRIVER.
- DO NOT OPEN THE MODULE AND SIDE PLATE OF THE REMOTE
- DRIVER BOX – NO SERVICEABLE PARTS INSIDE.
Trouble Shooting Guide
If this fixture fails to operate properly, use the guide below to diagnose and correct the problem.
- Verify that fixture is wired properly.
- Verify that fixture is grounded correctly.
- Verify that the line voltage at the fixture is correct.
If further assistance is required, contact:
Technical Support at: (800) 705-SERV (7378)
This LED module does not require service or new bulbs to change.
Acuity Brands Lighting, Inc.
One Lithonia Way, Conyers, GA 30012
www.acuitybrands.com/juno-recessed
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- Home | Juno Lighting | Acuity Brands
- U.S. Environmental Protection Agency | US EPA