SAMSUNG AM 220 FNHDEH Air Conditioner User Manual
- October 30, 2023
- Samsung
Table of Contents
AM 220 FNHDEH Air Conditioner
User Manual
AM 220 FNHDEH Air Conditioner
Duct Type Series
BIG duct : AMFNHDEH
imagine the possibilities
Thank you for purchasing this Samsung product.
features of your new air conditioner
-
Cool Summer Offer
On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. This summer, beat the heat with your own air conditioner. -
Cost Efficient System
Your new air conditioner not only provides maximum cooling power in the summer, but can also be an efficient heating method in the winter with the advanced “Heat pump” system. This technology is up to 300% more efficient than electrical heating, so you can further reduce its running cost. Now, meet year-round needs with one air conditioner. -
Flexible installation
Duct type air conditioner is designed to be slimmer and offers different solutions for any shape room allowing for specific air flow requirements. Also, the air intake can be set up on either the bottom or rear of the unit, so there is more flexibility in installation.
Safety information
Before using your new air conditioner, please read this manual thoroughly to
ensure that you know how to safely and efficiently operate the extensive
features and functions of your new appliance.
Because the following operating instructions cover various models, the
characteristics of your air conditioner may differ slightly from those
described in this manual. If you have any questions, call your nearest contact
center or find help and information online at
www.samsung.com.
Important safety symbols and precautions:
WARNING| Hazards or unsafe practices that may result in severe personal
injury or death.
---|---
CAUTION| Hazards or unsafe practices that may result in minor personal
injury or property damage.
| Follow directions.
| Do NOT attempt.
| Make sure the machine is grounded to prevent electric shock.
| Unplug the power plug from the wall socket.
| Do NOT disassemble.
FOR INSTALLATION
WARNING
Use the power line with the power specifications of the product or higher
and use the power line for this appliance only. In addition, do not use an
extension line.
-
Extending the power line may result in electric shock or fire.
-
Do not use an electric transformer. It may result in electric shock or fire.
-
If the voltage/frequency/rated current condition is different, it may cause fire.
The installation of this appliance must be performed by a qualified technician or service company. -
Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury.
Install a switch and circuit breaker dedicated to the air conditioner.
-
Failing to do so may result in electric shock or fire.
Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed. -
Failing to do so may result in electric shock or fire.
**** Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak.
-
This may result in electric shock or fire.
Never install the outdoor unit in a location such as on a high external wall where it could fall. -
If the outdoor unit falls, it may result in injury, death or property damage.
**** This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.
- Failure to do so may result in electric shock, fire, an explosion, or other problems with the product.
- Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes.
FOR INSTALLATION
CAUTION
**** Install your appliance on a level and hard floor that can support its
weight.
- Failing to do so may result in abnormal vibrations, noise, or problems with the product.
Install the draining hose properly so that water is drained correctly.
- Failing to do so may result in water overflowing and property damage.
When installing the outdoor unit, make sure to connect the draining hose so that draining is performed correctly.
- The water generated during the heating operation by the outdoor unit may overflow and result in property damage. In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest service
center.
Do not pull or excessively bend the power line. Do not twist or tie the
power line. Do not hook the power line over a metal object, place a heavy
object on the power line, insert the power line between objects, or push the
power line into the space behind the appliance.
- This may result in electric shock or fire.
FOR POWER SUPPLY
CAUTION
When not using the air conditioner for a long period of time or during a
thunder/lightning storm, cut the power at the circuit breaker.
- Failing to do so may result in electric shock or fire.
FOR USING
WARNING
**** If the appliance is flooded, please contact your nearest service
center.
- Failing to do so may result in electric shock or fire.
If the appliance generates a strange noise, a burning smell or smoke, unplug the power plug immediately and contact your nearest service center.
- Failing to do so may result in electric shock or fire.
In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do not touch the appliance or power line.
- Do not use a ventilating fan.
- A spark may result in an explosion or fire.
To reinstall the air conditioner, please contact your nearest service center.
- Failing to do so may result in problems with the product, water leakage, electric shock, or fire.
- A delivery service for the product is not provided. If you reinstall the product in another location, additional construction expenses and an installation fee will be charged.
- Especially, when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air, please contact your nearest service center.
FOR USING
WARNING
**** Do not touch the circuit breaker with wet hands.
- This may result in electric shock.
Do not strike or pull the air conditioner with excessive force.
- This may result in fire, injury, or problems with the product.
Do not place an object near the outdoor unit that allows children to climb onto the machine.
- This may result in children seriously injuring themselves.
Do not turn the air conditioner off with the circuit breaker while it is operating.
- Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire.
After unpacking the air conditioner, keep all packaging materials well out of the reach of children, as packaging materials can be dangerous to children.
- If a child places a bag over its head, it may result in suffocation.
Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating or the air flow blade is closing.
- Take special care that children do not injure themselves by inserting their fingers into the product.
Do not touch the air flow blade with your hands or fingers during the heating operation.
- This may result in electric shock or burns.
Do not insert your fingers or foreign substances into the air inlet/outlet of the air conditioner.
- Take special care that children do not injure themselves by inserting their fingers into the product.
Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people.
- Since this may be dangerous due to a lack of oxygen, Open a window at least once an hour.
**** If any foreign substance such as water has entered the appliance, cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service center.
- Failing to do so may result in electric shock or fire.
**** Do not attempt to repair, disassemble, or modify the appliance yourself.
- Do not use any fuse (such as copper, steel wire, etc.) other than the standard fuse.
- Failing to do so may result in electric shock, fire, problems with the product, or injury.
FOR USING
CAUTION
**** Do not place objects or devices under the indoor unit.
- Water dripping from the indoor unit may result in fire or property damage.
Check that the installation frame of the outdoor unit is not broken at least once a year.
- Failing to do so may result in injury, death or property damage.
Max current is measured according to IEC standard for safety and current is
measured according to ISO standard for energy efficiency.
**** Do not stand on top of the appliance or place objects (such as laundry,
lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.)
on the appliance.
- This may result in electric shock, fire, problems with the product, or injury.
Do not operate the appliance with wet hands.
- This may result in electric shock.
Do not spray volatile material such as insecticide onto the surface of the appliance.
- As well as being harmful to humans, it may also result in electric shock, fire or problems with the product.
Do not drink the water from the air conditioner.
- The water may be harmful to humans.
Do not apply a strong impact to the remote controller and do not disassemble
the remote controller.
Do not touch the pipes connected with the product.
- This may result in burns or injury.
Do not use this air conditioner to preserve precision equipment, food, animals, plants or cosmetics, or for any other unusual purposes.
- This may result in property damage.
FOR USING
CAUTION
**** Avoid directly exposing humans, animals or plants from the air flow
from the air conditioner for long periods of time.
- This may result in harm to humans, animals or plants.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance.
For use in Europe: This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children without supervision.
FOR CLEANING
WARNING
**** Do not clean the appliance by spraying water directly onto it. Do not
use benzene, thinner, alcohol or acetone to clean the appliance.
- This may result in discoloration, deformation, damage, electric shock or fire.
Before cleaning or performing maintenance, unplug the air conditioner from the wall socket and wait until the fan stops.
- Failing to do so may result in electric shock or fire.
FOR CLEANING
CAUTION
Take care when cleaning the surface of the heat exchanger of the outdoor
unit since it has sharp edges.
- To avoid cutting your fingers, wear thick cotton gloves when cleaning it.
**** Do not clean the inside of the air conditioner by yourself.
- For cleaning inside the appliance, contact your nearest service center.
- When cleaning the internal filter, refer to the descriptions in the ‘Cleaning and maintaining the air conditioner’ section.
- Failure to do may result in damage, electric shock or fire.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the
product and its electronic accessories (e.g. charger, headset, USB cable)
should not be disposed of with other household waste at the end of their
working life. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, please separate these items from other types of
waste and recycle them responsibly to promote the sustainable reuse of
material resources. Household users should contact either the retailer where
they purchased this product, or their local government office, for details of
where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the ter ms and
conditions of the purchase contract. This product and its electronic
accessories should not be mixed with other commercial wastes for disposal.
For more information on safe disposal and recycling, visit our website
www.samsung.com/in/support or contact
our Helpline numbers – 1800 40 SAMSUNG (1800 40 7267864).
For information on Samsung’s environmental commitments and product-specific
regulatory obligations, e.g. REACH, WEEE, Batteries, visit :
samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html
Viewing your air conditioner
Congratulations on the purchase of the air conditioner. We hope you enjoy the
features of your air conditioner and stay cool or warm with optimal
efficiency.
Please read the user manual to get started and to make the best use of the air
conditioner.
BIG DUCT TYPE
**** Your air conditioner may look slightly different from the illustration shown above depending on your model.
Using your air conditioner
TIPS ON USING YOUR AIR CONDITIONER
Here are some tips that you would follow when using your air conditioner.
TOPIC | RECOMMENDATION |
---|---|
Cooling | ♦ If current outside temperatures are much higher than the selected |
indoor temperature, it may take time to bring the inner temperature to the
desired coolness.
♦ Avoid drastically turning down the temperature.
Energy is wasted and the room does not cool faster.
Heating| ♦ Since the air conditioner heats the room by taking heat energy from
outdoor air, the heating capacity may decrease when outdoor temperatures are
extremely low. If you feel the air conditioner insufficiently heats, using an
additional heating appliance in combination with the air conditioner is
recommended.
Frost & De-ice| ♦ When the air conditioner runs in Heat mode, due to
temperature difference between the unit and the outside air, frost will form.
If this happens:
– The air conditioner stops heating.
– The air conditioner will operate automatically in De-ice mode for 10
minutes.
– The steam produced on the outdoor unit in De-ice mode is safe.
No intervention is required; after about 10 minutes, the air conditioner
operates again normally.
**** The unit will not operate when it starts to de-ice.
Fan| ♦ Fan may not operate for about 3~5 minutes at the beginning to prevent
any cold blasts while the air conditioner is warming up.
High indoor/outdoor temperatures| ♦ If both indoor and outdoor temperatures
are high and the air conditioner is running in Heat mode, the outdoor unit’s
fan and compressor may stop at times. This is normal; wait until the air
conditioner turns on again.
Power failure| ♦ If a power failure occurs during the operation of the air
conditioner, the operating immediately stops and unit will be off. When power
returns, the air conditioner will run automatically.
Protection mechanism| ♦ If the air conditioner has just been turned on after
operation stops or being plugged in, cool/warm air does not come out for 3
minutes to protect the compressor of the outdoor unit.
Cleaning and maintaining the air conditioner
MAINTAINING YOUR AIR CONDITIONER
If the air conditioner will not be used for an extended period of time, dry
the air conditioner to maintain it inbest condition.
- Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug. There may be internal damage if moisture is left in components.
- Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type| Description| Monthly| Every 4 months| Once a
year
---|---|---|---|---
Indoor unit| Clean the air filter (1)| | |
Clean the condensate drain pan (2)| | |
Thoroughly clean the heat exchanger (2)| | |
Clean the condensate drain pipe (2)| | |
Replace the remote control batteries (1)| | |
Outdoor unit| Clean the heat exchanger on the outside of the unit (2)| | |
Clean the heat exchanger on the inside of the unit (2)| | |
Clean the electric components with jets of air (2)| | |
Verify that all the electric components are firmly tightened (2)| | |
Clean the fan (2)| | |
Verify that all the fan assembly is firmly tightened (2)| | |
Clean the condensate drain pan (2)| | |
**** The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner. The frequency of these operations varies according to the characteristics of the area, the amount of dust, etc.
- The described operations should be performed more frequently if the area of installation is very dusty.
- These operations must always be performed by qualified personnel. For more detailed information, see the Installation Manual.
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air
conditioner.
Type | Description |
---|---|
Against cold air | The internal fan will be off to against cold air when the |
heat pump is heating.
De-ice cycle| The internal fan will be off to against cold air when the heat
pump is heating.
Anti-protection of internal battery| The compressor will be off to protect
internal battery when the air conditioner operates in Cool mode.
Protect compressor| The air conditioner does not start operating immediately
to protect the compressor of the outdoor unit after it has been started.
**** If the heat pump is operating in Heat mode, De-ice cycle is actuated to
remove frost from an outdoor unit that may have deposited at low temperatures.
The internal fan is switched off automatically and restarted only after the
de-ice cycle is completed.
Appendix
TROUBLESHOOTING
Refer to the following chart if the air conditioner operates abnormally. This
may save time and unnecessary expenses.
PROBLEM | SOLUTION |
---|---|
The air conditioner does not operate immediately after it has been restarted. |
• Because of the protective mechanism, the appliance does not start operating
immediately to keep the unit from overloading.
The air conditioner will start in 3 minutes.
The air conditioner does not work at all.| • Check that the power plug is
properly connected. Insert the power plug into the wall socket correctly.
• Check if the circuit breaker is switched off.
• Check if there is a power failure.
• Check your fuse. Make sure it is not blown out.
The temperature does not change.| • Check if you selected Fan mode. Press the
Mode button on the remote control to select another mode.
The cool (warm) air does not come out of the air conditioner.| • Check if the
set temperature is higher (lower) than the current temperature. Press the
Temperature button on the remote control to change the set temperature. Press
the Temperature button to decrease or increase the temperature.
• Check if the air filter is blocked by dirt. Clean the air filter every two
weeks.
• Check if the air conditioner has just been turned on. If so, wait 3 minutes.
Cool air does not come out to protect the compressor of the outdoor unit.
• Check if the air conditioner is installed in a place with a direct exposure
to sunlight. Hang curtains on windows to boost cooling efficiency.
• Check if the cover or any obstacle is not near the outdoor unit.
• Check if the refrigerant pipe is too long.
• Check if the air conditioner is only available in Cool mode.
• Check if the remote control is only available for cooling model.
The fan speed does not change.| • Check if you selected Auto or Dry mode. The
air conditioner automatically adjusts the fan speed to Auto in Auto/Dry mode.
Timer function does not set.| • Check if you press the Power button on the
remote control after you have set the time.
Odors permeate in the room during operation.| • Check if the appliance is
running in a smoky area or if there is a smell entering from outside. Operate
the air conditioner in Fan mode or open the windows to air out the room.
The air conditioner makes a bubbling sound.| • A bubbling sound may be heard
when the refrigerant is circulating through the compressor. Let the air
conditioner operate in a selected mode.
• When you press the Power button on the remote control, noise may be heard
from the drain pump inside the air conditioner.
Water is dripping from the air flow blades.| • Check if the air conditioner
has been cooling for an extended period of time with the air flow blades
pointed downwards. Condensation may generate due to the difference in
temperature.
Remote control is not working.| • Check if your batteries are depleted.
• Make sure batteries are correctly installed.
• Make sure nothing is blocking your remote control sensor.
• Check that there are strong lighting apparatus near the air conditioner.
Strong light which comes from fluorescent bulbs or neon signs may interrupt
the electric waves.
The air conditioner does not turn on or off with the wired remote control.| •
Check if you set the wired remote control for group control.
The wired remote control does not operate.| • Check if TEST indicator is
displayed on the wired remote control. If so, turn off the unit and switch off
the circuit breaker. Call your nearest contact center.
The indicators of the digital display flashes.| • Press the Power button on
the remote control to turn the unit off and switch the circuit breaker off.
Then, switch it on again.
OPERATION RANGES
The table below indicates the temperature and humidity ranges the air
conditioner can be operated within.
Refer to the table for efficient use.
MODE| OPERATIONAL TEMPERATURE| INDOOR HUMIDITY| IF OUT OF
CONDITIONS
---|---|---|---
INDOOR| OUTDOOR
COOLING| 18°C to 32°C| -5°C to 48°C| 80% or less| Condensation may occur on
the indoor unit with risk to have
either water blow off or drops on the floor.
HEATING| 27°C or less| -20°C to 24°C| | Internal protection triggers and the
air conditioner will stop.
DRYING| 18°C to 32°C| -5°C to 48°C| –| Condensation may occur on the indoor
unit with risk to have
either water blow off or drops on the floor.
**** The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can be reduced depending on the temperature condition. If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.
MODEL SPECIFICATION (WEIGHT AND DIMENSION)
Type | Model | Net Weight | Net Dimension (W×D×H) |
---|---|---|---|
Indoor unit (NASA) | AM220FNHDEH/EU | 89.0 kg | 1240×1040×470 mm |
AM280FNHDEH/EU | 89.0 kg | 1240×1040×470 mm |
Installation Part
Indoor Unit Installation
It is recommended to install the Y-joint before installing the indoor unit.
-
Place the pattern sheet on the ceiling at the spot where you want to install the indoor unit.
Note
Since the diagram is made of paper, it may shrink or stretch slightly due to temperature or humidity. For this reason, before drilling the holes maintain the correct dimensions between the markings. -
Insert bolt anchors, use existing ceiling supports or construct a suitable support as shown in figure.
-
Install the suspension bolts depending on the ceiling type.
CAUTION
◼ Ensure that the ceiling is strong enough to support the weight of the indoor unit.
Before hanging the unit, test the strength of each attached suspension bolt.
◼ If the length of suspension bolt is more than 1.5m, it is required to prevent vibration.
◼ If this is not possible, create an opening on the false ceiling in order to be able to use it to perform the required operations on the indoor unit. -
Screw eight nuts to the suspension bolts making space for hanging the indoor unit.
CAUTION
You must install the suspension bolts more than four when installing the indoor unit. -
Hang the indoor unit to the suspension bolts between two nuts.
Note
Piping must be laid and connected inside the ceiling when suspending the unit. If the ceiling is already constructed, lay the piping into position for connection to the unit before placing the unit inside the ceiling. -
Screw the nuts to suspend the unit.
-
Adjust level of the unit by using measurement plate for all 4 sides.
Note
For proper drainage of condensate, give a 1° slant to the left or right side of the unit which will be connected with the drain hose, as shown in the figure. Make a tilt when you wish to install the drain pump, too.
Performing Leak Test & Insulation
Leak test
LEAK TEST WITH NITROGEN(before opening valves)
In order to detect basic refrigerant leaks, before recreating the vacuum and
recirculating the R-410A, it’s responsible of installer to pressurize the
whole system with nitrogen(using a pressure regulator) at a pressure above
4.1MPa(gauge).
LEAK TEST WITH R-410A(after opening valves) Before opening valves, discharge
all the nitrogen into the system and create vacuum. After opening valves check
leaks using a leak detector for refrigerant R-410A.
CAUTION
Discharge all the nitrogen to create a vacuum and charge the system.
Insulation
Once you have checked that there are no leaks in the system, you can
insulate the piping and hose.
-
To avoid condensation problems, place T13.0 or thicker Acrylonitrile Butadien Rubber separately around each refrigerant pipe.
Note
Always make the seam of pipes face upwards. -
Wind insulating tape around the pipes and drain hose avoiding to compress the insulation too much. CAUTION
Must fit tightly against body without any gap. -
Finish wrapping insulating tape around the rest of the pipes leading to the outdoor unit.
-
The pipes and electrical cables connecting the indoor unit with the outdoor unit must be fixed to the wall with suitable ducts.
CAUTION
All refrigerant connection must be accessible, in order to permit either unit maintenance or removing it completely. -
Select the insulation of the refrigerant pipe.
♦ Insulate the gas side and liquid side pipe referring to the thickness according to the pipe size.
♦ Indoor temperature of 30°C and humidity of 85% is the standard condition.
If install in a high humidity condition,use one grade thicker insulator by referring to the table below.
If installing in an unfavorable conditions,use thicker one.
♦ Insulator’s heat-resistance temperature should be more than 120°C.
Pipe | Pipe size | Insulation Type(Heating/Cooling) | Remarks |
---|---|---|---|
Standard [30°C,85%] | High humidity [30°C,over 85%] |
EPDM,NBR
Liquid pipe| 06.35-09.52| 9t| | Internal temperature is higher than 120°C
,
012.7-050.80| 13t|
—
Gas Pipe| 06.35| 13t| 19t
09.52| 19t| 25t
012.70
015.88
019.05
022.23
025.40
028.58| 32t
031.75
038.10
044.45
050.80| 25t| 38t
CAUTION
- Install the insulation not to get wider and use the adhesives on the connection part of it to prevent moisture from entering.
- Wind the refrigerant pipe with insulation tape if it is exposed to outside sunlight.
- Install the refrigerant pipe respecting that the insulation does not get thinner on the bent part or hanger of pipe.
- Add the additional insulation if the insulation plate gets thinner.
Drain pipe and Drain Hose Installation
-
Install the drain hose as short as possible.
Note
♦ Give a 10mm slant to the drain hose for proper drainage of condensate.
♦ Secure the drain hose with the cable-tie not to be separated from the unit.
♦ The drain pump connection port is used when using a drain pump. -
Insulate the drain hose and then fix it as a picture.
Note
♦ Assemble flexible hose with clamps between indoor unit and drain pipe.
♦ Flexible hose clamps should be assembled tightly to prevent being loosen. If it is loosen, it may cause water drops.
Drainpipe Connection
Without the drain pump
- Install horizontal drainpipe with a slope of 1/100 or more and fix it by hanger space of 1.0~1.5m.
- Install U-trap at the end of the drainpipe to prevent a nasty smell to reach the indoor unit.
- Do not install the drainpipe to upward position.
It may cause water flow back to the unit.
With the drain pump
-
The drain pipe should be installed within 300mm to 550mm from the flexible hose and then lift down 20mm or more.
-
Install horizontal drainpipe with a slope of 1/100 or more and fix it by hanger space of 1.0~1.5m.
-
Install the air vent in the horizontal drainpipe to prevent water flow back to the indoor unit.
Note
You may not need to install it if there were proper slope in the horizontal drainpipe. -
The flexible hose should not be installed upward position, it may cause water flow back to the indoor unit.
Centralized Drainage
Without the drain pump
- Install horizontal drainpipe with a slope of 1/100 or more and fix it by hanger space of 1.0~1.5m.
- Install U-trap at the end of the drainpipe to prevent a nasty smell to reach the indoor unit.
With the drain pump
- Install main air vent at the front of the farthest indoor unit from the main drain when installed indoor units are more than 3.
- You may need to install individual air vent to prevent water flow back at the top of each indoor unit drainpipe.
Wiring Work
Power and communication cable connection
-
Before wiring work, you must turn off all power source.
-
Indoor unit power should be supplied through the breaker(ELCB or MCCB+ELB) separated by the outdoor power.
ELCB: Earth Leakage Circuit Breaker
MCCB:Molded Case Circuit Breaker
ELB:Earth Leakage Breaker -
The power cable should be used only copper wires.
-
Connect the power cable{1(L), 2(N)} among the units within maximum length and communication cable(F1, F2) each.
-
Connect F3, F4(for communication) when installing the wired remote Control.
ELCB : Essential Installation
WARNING
Power off before connecting any wires;
Indoor PBA will be damaged while V1,V2,F3,F4 short each other.
Selecting compressed ring terminal
Nominal
dimensions
for cable (mm2)| Nominal
dimensions
for screw (mm)| B| D| dl| E| F| L| d2| t
---|---|---|---|---|---|---|---|---|---
Standard
dimension
(mm)| Allowance
(mm)| Standard
dimension
(mm)| Allowance
(mm)| Standard
dimension
(mm)| Allowance
(mm)| Min.| Min.| Max.| Standard
dimension
(mm)| Allowance
(mm)| Min.
1.5| 4| 6.6| ±0.2| 3.4| + 0.3
– 0.2| 1.7| ±0.2| 4.1| 6| 16| 4.3| +0 .2
0| 0.7
4| 8
2.5| 4| 6.6| ±0.2| 4.2| + 0.3
– 0.2| 2.3| ±0.2| 6| 6| 17.5| 4.3| +0 .2
0| 0.8
4| 8.5
4| 4| 9.5| ±0.2| 5.6| +0.3
– 0| 3.4| ±0.2| 6| 5| 20| 4.3| +0.2
0| 0.9
Specification of electronic wire
Power supply | MCCB | ELB or ELCB | Power cable | Earth cable | Communication cable |
---|
Max : 242V
Min : 198V| X A| X A, 30mmA 0.1 s| 2.5mm²| 2.5mm²| 0.75~1.5mm²
- Decide the capacity of ELCB(or MCCB+ELB) by below formula.
- Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord. (Code designation IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC: H07RN-F)
The capacity of ELCB(or MCCB+ELB) X [A] = 1.25 X 1.1 X ∑Ai
X : The capacity of ELCB(or MCCB+ELB).
∑Ai : Sum of Rating currents of each indoor unit.
Refer to each installation manual about the rating current of indoor unit.
Decide the power cable specification and maximum length within 10% power drop
among indoor units.
Coef: 1.55
Lk: Distance among each indoor unit[m],
Ak: Power cable specification[mm²], ik: Running current of each unit[A]
- Run transmission wiring between the indoor and outdoor units through a conduit to protect against external forces, and feed the conduit through the wall together with refrigerant piping.
Setting an indoor unit address and installation option
Set the indoor unit address and installation option with remote controller
option.
Set the each option separately since you cannot set the ADDRESS setting and
indoor unit installation setting option at the same time. You need to set
twice when setting indoor unit address and installation option.
The procedure of option setting
❋ The display of the remote controller may be different depending on the
model.
Step 1. Entering mode to set option
- Remove batteries from the remote controller.
- Insert batteries and enter the option setting mode while pressing High Temp button and Low Temp button .
- Check if you have entered the option setting status.
Step 2. The procedure of option setting
After entering the option setting status, select the option as listed below.
CAUTION
Option setting is available from SEG1 to SEG 24
- SEG1, SEG7, SEG13, SEG19 are not set as page option.
- Set the SEG2~SEG6, SEG8~SEG12 as ON status and SEG14~18, SEG20~24 as OFF status.
SEG1 | SEG2 | SEG3 | SEG4 | SEG5 | SEG6 | SEG7 | SEG8 | SEG9 | SEG10 | SEG11 | SEG12 |
---|---|---|---|---|---|---|---|---|---|---|---|
0 | X | X | X | X | X | 1 | X | X | X | X | |
SEG13 | SEG14 | SEG15 | SEG16 | SEG17 | SEG18 | SEG19 | SEG20 | SEG21 | SEG22 | SEG23 |
SEG24
2| X| X| X| X| X| 3| X| X| X| X| X
On(SEG1~12)| Off(SEG13~24)
---|---
|
Option setting| Status
---|---
1. Setting SEG2, SEG3 option
Press Low Fan button(∨) to enter SEG2 value.
Press High Fan button(∧) to enter SEG3 value.
Each time you press the button, will be selected in rotation.|
2. Setting Cool mode
Press Mode button to be changed to Cool mode in the ON status.|
3. Setting SEG4, SEG5 option
Press Low Fan button(∨) to enter SEG4 value.
Press High Fan button(∧) to enter SEG5 value.
Each time you press the button, will be selected in rotation.|
4. Setting Dry mode
Press Mode button to be changed to DRY mode in the ON status.|
5. Setting SEG6, SEG8 option
Press Low Fan button(∨) to enter SEG6 value.
Press High Fan button(∧) to enter SEG8 value.
Each time you press the button, will be selected in rotation.|
6. Setting Fan mode
Press Mode button to be changed to FAN mode in the ON status.|
7. Setting SEG9, SEG10 option
Press Low Fan button(∨) to enter SEG9 value.
Press High Fan button(∧) to enter SEG10 value.
Each time you press the button, will be selected in rotation.|
8. Setting Heat mode
Press Mode button to be changed to HEAT mode in the ON status.|
9. Setting SEG11, SEG12 option
Press Low Fan button(∨) to enter SEG11 value.
Press High Fan button(∧) to enter SEG12 value.
Each time you press the button, will be selected in rotation.|
10. Setting Auto mode
Press Mode button to be changed to AUTO mode in the OFF status.|
11. Setting SEG14, SEG15 option
Press Low Fan button(∨) to enter SEG14 value.
Press High Fan button(∧) to enter SEG15 value.
Each time you press the button, will be selected in rotation.|
12. Setting Cool mode
Press Mode button to be change to Cool mode in the OFF status.|
13. Setting SEG16, SEG17 option
Press Low Fan button(∨) to enter SEG16 value.
Press High Fan button(∧) to enter SEG17 value.
Each time you press the button, will be selected in rotation.|
14. Setting Dry mode
Press Mode button to be change to Dry mode in the OFF status.|
15. Setting SEG18, SEG20 option
Press Low Fan button(∨) to enter SEG18 value.
Press High Fan button(∧) to enter SEG20 value.
Each time you press the button, will be selected in rotation.|
16. Setting Fan mode
Press Mode button to be change to Fan mode in the OFF status.|
17. Setting SEG21, SEG22 option
Press Low Fan button(∨) to enter SEG21 value.
Press High Fan button(∧) to enter SEG22 value.
Each time you press the button, will be selected in rotation.|
18. Setting Heat mode
****Press Mode button to be change to HEAT mode in the OFF status.|
19. Setting SEG23, SEG24 mode
Press Low Fan button(∨) to enter SEG23 value.
Press High Fan button(∧) to enter SEG24 value.
Each time you press the button, will be selected in rotation.|
Step 3. Check the option you have set
After setting option, press **** button to check whether the option code you
input is correct or not.
Step 4. Input option
Press operation button ** with the direction of remote control for set.
For the correct option setting, you must input the option twice.
Step 5. Check operation**
- Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit.
- Take the batteries out of the remote controller and insert them again and then press the operation button.
Setting an indoor unit address (MAIN/RMC)
-
Check whether power is supplied or not.
– When the indoor unit is not plugged in, there should be additional power supply in the indoor unit. -
The panel(display) should be connected to an indoor unit to receive option.
-
Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan.
-
Assign an indoor unit address by wireless remote controller.
– The initial setting status of indoor unit ADDRESS(MAIN/RMC) is “0A0000-100000-200000-300000”.
Option No. : 0AXXXX-1XXXXX-2XXXXX-3XXXXX
Option | SEG1 | SEG2 | SEG3 | SEG4 | SEG5 | SEG6 |
---|---|---|---|---|---|---|
Explanation | PAGE | MODE | Setting Main address | it of indoor 100 digit | ||
unit address | 10-digit of indoor unit | The unit digit of an |
indoor unit
Remote
Controller
Display| | | | | |
Indication
and Details| Indication| Details| Indication| Details| Indication| Details|
Indication| Details| Indication| Details| Indication| Details
0| A| 0| No Main
address| 0-9| 100-digit| 0-9| 10-digit| 0-9| A unit
digit
1| Main address setting mode
Option| SEG7| SEG8| SEG9| SE110| SEG11| SEG12
Explanation| PAGE| and Details| Setting RMC address| –| Group channel(16)|
Group address
|
Remote
Controller
Display|
Indication| Details| Indication| Details
_ Indication| Details
Indication| Indication| Details
RMC1| 0—F| RMC2| O—F
0| No RMC
address
1
1| address
setting
mode
CAUTION
- When “A”~”F” is entered to SEG5~6, the indoor unit MAIN ADDRESS is not changed.
- If you set the SEG 3 as 0, the indoor unit will maintain the previous MAIN ADDRESS even if you input the option value of SEG5~6.
- If you set the SEG 9 as 0, the indoor unit will maintain previous RMC ADDRESS even if you input the option value of SEG11~12.
- You cannot set SEG11 and SEG12 as F value at the same time.
Setting an indoor unit installation option (suitable for the condition of each installation location)
-
Check whether power is supplied or not.
– When the indoor unit is not plugged in, there should be additional power supply in the indoor unit. -
The panel(display) should be connected to an indoor unit to receive option.
-
Set the installation option according to the installation condition of an air conditioner.
– The default setting of an indoor unit installation option is “020010-100000- 200000-300000”.
– Individual control of a remote controller(SEG20) is the function that controls an indoor unit individually when there is more than one indoor unit. -
Set the indoor unit option by wireless remote controller.
02 series installation option
SEG1 | SEG2 | SEG3 | SEG4 | SEG5 | SEG6 |
---|---|---|---|---|---|
0 | 2 | External room temperature sensor/ Minimizing fan | |||
operation when thermostat is off | Central control compensation | FAN RPM | |||
SEG7 | SEG8 | SEG9 | SEG10 | SEG11 | SEG12 |
1 | Drain pump | Hot water heater | – | EEV Step when heating stops | – |
SEG13 | SEG14 | SEG15 | SEG16 | SEG17 | SEG18 |
2 | External control | External control output / External heater On or Off | |||
signal | S-Plasma ion | Buzzer | Number of hours using filter | ||
SEG19 | SEG20 | SEG21 | SEG22 | SEG23 | SEG24 |
3 | Individual control of a remote controller | Heating setting compensation / | |||
Removing condensated water in heating mode | EEV Step of stopped unit during | ||||
oil return/defrost mode | Motion detect sensor | – |
-
1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to ‘USE + 3minute delay’ even if the drain pump is set to 0.
-
1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using filter(SEG18) will be set to ‘1000hour’ even if the SEG18 is set to except for 2 or 6.
-
When setting the option other than above SEG values, the option will be set as “0”.
-
SEG5 central control option is basically set as 1 (Use), so you don’t need to set the central control option additionally.
However, if the central control is not connected but it doesn’t indicate an error message, you need to set the central control option as 0 (Disuse) to exclude the indoor unit from the central control. -
The output of hot water heater in SEG9 is generated from the hot coil part of the terminal board in duct models.* The output of hot coil terminal is AC 220 V / 230 V (The same as Indoor Unit’s input Power)
-
The external output of SEG15 is generated by MIM-B14 connection. (Refer to the manual of MIM-B14.)
02 series installation option(Detailed)
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option | SEG1 | SEG2 | SEG3 | SEGO | SEG5 | SEG6 |
---|---|---|---|---|---|---|
Explanation | PAGE | MODE | Use of robot cleaning | Use of eitamal room |
temperature sen sor /
Minimting fan operat on when thermostat
is off| Use of centrai control| FAN RPM compensation
Remote
Controller
Display| | | | | |
Indication
and Details| Indication| Details| Indication| Details| Indication| Details|
Indication| Details| Indication| Details| Indcation| Details
Use of External room
temperature sensor| Minimizing
fan operation
when thermostat
is off
0| 2| 0| Disuse| 0| Disuse| Disuse| 0| Disuse| 0| Disuse
1| Use| 1| Use| Disuse| 1| Use| 1| RPM
compensation
2| High ceiling KIT
2| Disuse| Use(1)
3| Use| Use(1)
Option| SEG7| SEG8| SEG9| SEGIO| SEG11| SEG12
Explanation| PAGE| Use of drain pump| Used hot water heater| | EEV Step when
heating stops|
Remote
Controller
Display| | | | | |
Indication
and Details| Indication| I Details| Indication| Details| Indication| Dads|
Indication| Details| Indication| Details| Indication| I Details
1| 0| Disuse| 0| Disuse| | 0
1| Default
value Noise
decreasing
setting|
1| Use| 1| User”
2| When an indoor unit stops, drain pump will operate for
3min.| 2| –
3| Use'”
Option| SEG13| SEG14| SEG15| SEG16| SEG17| SEG18
Explanation| PAGE| Use of external control| Setting the output of external
controVExternal heater On/Off signal| S-Plasma ion| Buzzer control| Number of
hours using filter
Remote
Controller
Display| | | | | |
Indication
and Details| Indication| Details| Indication| Details| Indication| Details|
Indication| Details| Indication| Details| Indication| Details
Setting the
outputof
external
control| External
heaterOnl
Off signal
2| 0| Disuse| 0| Thermo on| | 0| Disuse| 0| Use buzzer| 2| 1000 Hour
1| ON/OFF
control| 1| Operation on| | 1| Use| 1| Disuse
buzzer| 6| 2000Hour
2| OFF control| 2| –| Grp
3| Window
OWOFF
control| 3| –| Use et
Option| SEG19| SEG20| SEG21| SEG22| SEG23| SEG24
---|---|---|---|---|---|---
Explanation| PAGE| Individual control of a
remote controller| Heating setting compensation / Removing
condensated water in heating mode| EEV Step of stopped
unit during oil return /
defrost mode| Motion detect sensor| –
Remote
Controller
Display| | | | | |
Indication and
Details| Indication| Details| Indication| Details| Indication| Details|
Indication| Details| Indication| Details
Heating Setting
Compensation| Removing
Condensated
Water in Heating
Mode
3| 0 or 1| channel 1| 0| Default (m)| Disuse| 0| Default
value| 0| Disuse
1| 2 °C| Disuse| 1| Tun out in 30min.
Wit110Ut motion
2| channel 2| 2| 5°C| Disuse| 1| Oil retum or Noise decreasing in defrost
mode| 2| out in 60min.
Turn without motion
3| channel 3| 3|
Default (*4)
| Use(5)| 3| Tum outin120min.
without motor
4| channel 4| 4| 2°C| Use(5)| 4| Tum out in 180min.
without motion
5| 5 °C| Use”’| 5| Tun out in 30min.
withart ridicin °I.
advanced function
6| Tum out in 60min.
without motion a
advanced function
7| Tum out in 120min.
without motion or
advancedfunction|
8| Tum outin 180min.
without motion or
advanced function|
- Advanced function: Controlling cooling/heating current or power saving with motion detect.
(1) Minimizing fan operation when thermostat is off
– Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
(2) 1: Fan is turned on continually when the hot water heater is turned on,
3: Fan is turned off when the hot water heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option, install the Mode Select switch (MCM-C200) on the outdoor unit and fix it as cool mode.
(3) When the following 2 or 3 is used as external heater On/Off signal, the signal for monitoring external contact control will not be output.
2: Fan is turned on continually when the external heater is turned on,
3: Fan is turned off when the external heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option, install the Mode Select switch (MCM-C200) on the outdoor unit and fix it as cool mode.
❋ If Fan is set to off for cooling only indoor unit by setting the SEG9=3 or SEG15=3, you need to use an external sensor or wired remote controller sensor to detect indoor temperature exactly.
(4) Default setting value
– 4Way Cassette, Mini 4Way Cassette: 5 °C
– Other indoor units: 2 °C
(*5) This function can be applied to 4 Way Cassette and Mini 4 Way Cassette only. If the air conditioner operates the heating mode immediately after finishing the cooling mode, the condensated water in the drain pan becomes water vapor by the heat of the indoor unit heat exchanger. Since the water vapor might be condensed on the indoor unit, which may fall into a living space, use this function to get rid of the water vapor out of the indoor unit by operating the fan (for maximum 20 minutes) even when the indoor unit is turned off after cooling mode is turned to heating mode .
CAUTION
Do not install the electronic heater in the flow channel of the indoor unit fan.
05 series installation option
SEG1 | SEG2 | SEG3 | SEG4 | SEG5 | SEG6 |
---|---|---|---|---|---|
0 | 5 | Use of Auto Change | |||
Over for HR only in Auto mode | (When setting SEG3) |
Standard heating temp.
Offset| (When setting SEG3)
Standard cooling temp.
Offset| (When setting SEG3) Standard for mode change
Heating → Cooling
SEG7| SEG8| SEG9| SEG10| SEG11| SEG12
1| (When setting SEG3)
Standard for mode change
Cooling — Heating| (When setting SEG3)
Time required for mode change| Compensation option for Long pipe or height
difference between
indoor units| –| –
SEG13| SEG14| SEG15| SEG16| SEG17| SEG18
2| –| –| –| –| Control variables when using hot water / external heater
SEG19| SEG20| SEG21| SEG22| SEG23| SEG24
3| –| –| –| –| –
05 series installation option(Detailed)
Option No. : 05XXXX-1XXXXX-2XXXXX-3XXXXX
Option | SEG1 | SEG2 | SEG3 | SEG4 | SEG5 | SEG6 |
---|---|---|---|---|---|---|
Explanation | PAGE | MODE | Use of Auto Change | |||
Over for HR only in Auto mode | (When setting SEG3) |
Standard heating temp
Offset| (When setting SEG3)
Standard cooling temp.
Offset| (i./tahnercasredttionrgniSEg)
change
Heating — Cooling
Remote
Controller
Display| | | | | |
Indication
and Details| Indication| 1 Details| Indication| I Details| Indication|
Details| Indication| Details| Indication| Details| Indication| Details
0| 5| 0| Follow product option| 0| 0°C| 0| 0 °C| 0| 1°C
1| Use Auto Change Ov HR only| | 1| 0.5°C| 1| 05°C| 1| 1.5°C
2| 1°C| 2| 1 °C| 2| 2 °C
3| 1.5°C| 3| 1.5 °C| 3| 2.5°C
4| 2°C| 4| 2 °C| 4| 3 °C
5| 2.5°C| 5| 2.5°C| 5| 3.5°C
6| 3°C| 6| 3°C| 6| 4°C
7| 3.5°C| 7| 3.5°C| 7| 4.5°C
Option| SEG7| SEG8| SEG9| SEG10| SEG11| SEG12
Explanation| PAGE| (When setting SEG3)
Standard for mode change Cooling—Heating| (When setting SEG3)
Time required for mode chair| Compensation option
for Long pipe or height
diffference between
indoor units| |
Remote
Controller
Display| | | | | |
Indication
and Details| Indication| I Details| Indication| Details| Indication| Details|
Indication| Details| | | |
1| 0| 1 °C| 0| 5 min.| 0| Use defauitvalue| |
1| 15 °C| 1| 7 min.| 1| 1) Height
difference1)
is more
than 30m
or
2)Distance2)
is longer
than 110m
2| 2°C| 2| 9 min.
3| 25 °C| 3| 11 min.
4| 3°C| 4| 13min.| 2| 1) Height
difference1)
is 15~30m
or
2)Distance2)
is 50~110m
5| 35 °C| 5| 15 min.
6| 4°C| 6| 20 min.
7| 45 °C| 7| 30 min.
Option| SEG13| SEG14| SEG15| SEG16| SEG17| SEG183′
---|---|---|---|---|---|---
Explanation| | | | | | Control variables when using hot water / external
heater
Remote Controller
Display| | | | | |
Indication and
Details| | | | | | | | | | Indication| Details
Set temp. for heater On/Off| Delay time for
heater On
2| | | | | 0| At the same time
as thermo on| No delay
1| At the same time
as thermo on| 10 minutes
2| At the same time
as thermo on| 20 minutes
3| 1.5 °C| No delay
4| 1.5 °C| 10 minutes
5| 1.5 °C| 20 minutes
6| 3.0 °C| No delay
7| 3.0 °C| 10 minutes
8| 3.0 °C| 20 minutes
9| 4.5 °C| No delay
A| 4.5 °C| 10 minutes
B| 4.5 °C| 20 minutes
C| 6.0°C| No delay
D| 6.0 °C| 10 minutes
E| 6.0 °C| 20 minutes
-
Height difference : The difference of the height between the corresponding indoor uint and the indoor unit installed at the lowest place.
For example, When the indoor unit is installed 40m higher than the indoor unit installed at the lowest place, select the option “1”. -
Distance : The difference between the pipe length of the indoor unit istalled at farthest place from an outdoor unit and the pipe length of the corresponding indoor unit from an outdoor unit.
For example, when the farthest pipe length is 100m and the corresponding indoor unit is 40 m away from an outdoor unit, select the option “2”. (100 – 40 = 60 m) -
Heater operation when the SEG9 of 02 series installation option is set to using hot water heater or when SEG15 is set to using external heater
e.g. 1)
Setting 02 series SEG9 =”1” / Setting 05 series SEG18 = “0”: Hot water heater
is turned on at the same time as the heating thermostat is on, and turned off
when the heating thermostat is off.
e.g. 2)
Setting 02 series SEG15 =”2” / Setting 05 series SEG18 =”A”:
Room temp. ≤ set temp. + f(heating compensation temp.)
– External heater is turned on when the temperature is maintained as 4.5 °C
for 10 minutes.
Room temp. > set temp. + f(heating compensation temp.)
– External heater is turned off when the temperature is maintained as 4.5 °C +
1 °C (1 °C is the Hysteresis for On/Off selection.]
SEG 3, 4, 5, 6, 8, 9 additional information
When the SEG 3 is set as “1” and follow Auto Change Over for HR only
operation, it will operate as follows.
Cooling/Heating mode can be changed when Thermo Off status is maintained during the time with SEG9.
Changing a particular option
You can change each digit of set option.
Option | SEG1 | SEG2 | SEG3 | SEG4 | SEGS | SEG6 |
---|---|---|---|---|---|---|
Explanation | PAGE | MODE | The option mode you want to change | The tens’ digit | ||
of an option SEG you will change | The unit digit of an option SEG you will | |||||
change | The changed value |
Remote Controller
Display| | | | | |
Indication and Details| Indication| Details| Indication| Details| Indication|
Details| Indication| Details| Indication| Details| Indication| Details
0| D| Option mode| 1~6| Tens’ digit of SEG| 0~9| Unit digit of SEG| 0~9| The
changed value| 0~F
Note:
- When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’
- When changing a digit of indoor unit installation option, set the SEG3 as ‘2°
Ex) When setting the ‘buzzer control’ into disuse status.
Option | SEG1 | SEG2 | SEG3 | SEG4 | SEG5 | SEG6 |
---|---|---|---|---|---|---|
Explanation | PAGE | MODE | The option mode you want to change | The tens’ digit | ||
of an option SEG you will change | The unit digit of an option SEG you will | |||||
change | The changed value | |||||
Indication | 0 | D | 2 | 1 | 7 | 1 |
Setting temperature control of discharge air
- Use of “Temperature control of discharge air” or target temperature of discharge air in cooling/heating can be set with the service mode of a wired remote controller. (Refer to the installation manual of a wired remote controller.)
- When using temperature control of discharge air, thermo on/off of Indoor unit is decided by set room temperature and room temperature, and the temperature of discharge air is adjusted to meet the target temperature of discharge air in thermostat On section.
- When using temperature control of discharge air, the temperature of discharge air cannot always be adjusted to the target temperature due to external conditions or protective control of the outdoor unit.
❋ Temperature control of discharge air can be set with DMS as well.
QUESTIONS OR COMMENTS?
COUNTRY | CALL | OR VISIT US ONLINE AT |
---|---|---|
UK | 0330 SAMSUNG (7267864) |
www.samsung.com/uk/support
IRELAND (EIRE)| 0818 717100|
www.samsung.com/ie/support
GERMANY| 06196 77 555 77 OTH|
www.samsung.com/de/support
FRANCE| 01 48 63 00 00|
www.samsung.com/fr/support
ITALIA| 800-SAMSUNG (800.7267864)|
www.samsung.com/it/support
SPAIN| 0034902172678|
www.samsung.com/es/support
PORTUGAL| 808 207 267|
www.samsung.com/pt/support
LUXEMBURG| 261 03 710|
www.samsung.com/be_fr/support
NETHERLANDS| 088 90 90 100|
www.samsung.com/nl/support
BELGIUM| 02-201-24-18| www.samsung.com/be/support
(Dutch)
www.samsung.com/be_fr/support (French)
NORWAY| 21629099|
www.samsung.com/no/support
DENMARK| 707 019 70|
www.samsung.com/dk/support
FINLAND| 030-6227 515|
www.samsung.com/fi/support
SWEDEN| 0771 726 786|
www.samsung.com/se/support
POLAND| 801-172-678 lub +48 22 607-93-33
Dedykowana infolinia do obsługi zapytań dotyczących telefonów komórkowych:
801-672-678 lub +48 22 607-93-33*
- (opłata według taryfy operatora)| http://www.samsung.com/pl/support/
HUNGARY| 0680SAMSUNG (0680-726-7864)| www.samsung.com/hu/support
AUSTRIA| 0800-SAMSUNG (0800-7267864)
[Only for KNOX customers] 0800 400848
[Only for Premium HA] 0800-366661
[Only for Dealers] 0810-112233
[Only for E-Store] 0800 100 232| www.samsung.com/at/support
SWITZERLAND| 0800 726 78 64 (0800-SAMSUNG)| www.samsung.com/ch/support (German)
www.samsung.com/ch_fr/support (French)
CZECH| 800 – SAMSUNG (800-726786)| www.samsung.com/cz/support
SLOVAKIA| 0800 – SAMSUNG (0800-726 786)| www.samsung.com/sk/support
CROATIA| 072 726 786| www.samsung.com/hr/support
BOSNIA| 055 233 999| www.samsung.com/support
MONTENEGRO| 020 405 888| www.samsung.com/support
SLOVENIA| 080 697 267 (brezplačna številka)| www.samsung.com/si/support
SERBIA| 011 321 6899| www.samsung.com/rs/support
ALBANIA| 045 620 202| www.samsung.com/al/support
BULGARIA| 3000 Цена в мрежата
0800 111 31 , Безплатна телефонна линия| www.samsung.com/bg/support
ROMANIA| 8000 (apel in retea)
08008-726-78-64 (08008-SAMSUNG) Apel GRATUIT| www.samsung.com/ro/support
CYPRUS| 8009 4000 only from landline, toll free| www.samsung.com/gr/support
GREECE| 80111-SAMSUNG (80111 726 7864) only from land line (+30) 210 6897691 from mobile and land line
LITHUANIA| 8-800-77777| www.samsung.com/lt/support
LATVIA| 8000-7267| www.samsung.com/lv/support
ESTONIA| 800-7267| www.samsung.com/ee/support
INDIA| 1800 40 SAMSUNG (1800 40 7267864) (Toll-Free)| www.samsung.com/in/support
SAMSUNG ELECTR ONICS CO., LTD .
107, Hanamsandan 6beon-ro, Gwangsan-gu, Gwangju-si, Korea 62218
Samsung Electronics
Service Department
PO Box 12987, Blackrock, Co. Dublin. Ireland
or
Blackbushe Business Park, Yateley, GU46 6GG. UK
This product is RoHS compliant DB68-03655A-08
Documents / Resources
|
SAMSUNG AM 220 FNHDEH Air
Conditioner
[pdf] User Manual
AM 220 FNHDEH Air Conditioner, AM 220 FNHDEH, Air Conditioner, Conditioner
---|---
References
- Company Info | About Us | Samsung UK
- Samsung US | Mobile | TV | Home Electronics | Home Appliances | Samsung US
- Ndihma dhe mbështetja për produktet | Samsung Albania
- Hilfe & Support für Produkte | Samsung Österreich
- Aide et assistance produit | Samsung Belgique
- Aide et support pour le produit | Samsung Suisse
- Produkthilfe & Support | Samsung CH
- Podpora a nápověda k produktům | Samsung Česká republika
- Hilfe und Support für Samsung Produkte | Samsung DE
- Produkt Hjælp & Support | Samsung DK
- Toodete abi ja tugi | Samsung EE
- Ayuda y soporte del producto | Samsung ES
- Aide et assistance produit | Samsung France
- Βοήθεια και υποστήριξη προϊόντων | Samsung Greece
- Pomoć i podrška za proizvode | Samsung Hrvatska
- Terméktámogatás | Samsung Magyarország
- Product Help & Support | Samsung Ireland
- Product Help & Support | Samsung India
- Aiuto e servizio di assistenza per i prodotti | Samsung Italia
- Ar produktiem saistīta palīdzība un atbalsts | Samsung Latvija
- Produkt Hjelp og støtte | Samsung Norge
- Pomoc dotycząca produktu | Samsung PL
- Ajuda e assistência técnica do produto | Samsung Portugal
- Ajutor și asistență pentru produs | Samsung Romania
- Pomoć i podrška za proizvode | Samsung Srbija
- Pomoč in podpora za izdelek | Samsung Slovenija
- Pomoc a podpora k produktu | Samsung Slovenská republika
- Support Home | Official Samsung Support US
- Product Help & Support | Samsung UK
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>