SAFETY FIRST!
Do not shine the torch directly into any person’s eyes as this may result in injury.
Torch operation
The single push button switch on the top of the torch incorporates a battery status indicator.

  1.  To turn on the torch, push once on the switch. This will activate the torch at full brightness.
  2. To activate the dimming feature, push the switch within three seconds after step (1)
  3. To activate strobe feature, push the switch within three seconds after step (2)
  4. To turn the torch off, push the switch after three seconds on any of the above steps.

Battery Status Indicator
This torch includes a battery status indicator incorporated into the switch.
When the torch is activated, the opaque switch boot will turn:

  1. Green to indicate that the battery is at 76%-100% of capacity
  2.  Amber to indicate that the battery is at 25%-75% of capacity
  3.  Red to indicate that the battery is at 24% or less of capacity

Attaching the power cord
Before attempting to charge the torch, the power cord plug should be installed into the socket located on the underside of the charger  base. Once the plug is installed, push the cord into the channel.PELI 9415Z0 Rechargeable
Flashlight - HEAD Torch charging

  • Set the 9415Z0 on the charger slots.
  • Push the torch down while sliding it backwards and release.
  • The LED indicator light in the rear of the charger base will turn flashing RED indicating charging is in process, when the light turns solid GREEN charging is complete.

It is not necessary to remove the torch at this point as the charger will only give a maintenance charge.
WARNING! – DO NOT CHARGE OR CHANGE
BATTERIES IN A HAZARDOUS AREA.
Battery Replacement
To replace the battery:

  1. Use a Philips screw driver to remove six screws on the bottom housing
  2.  Carefully unplug the connectors (as shown)
  3.  Remove battery pack

To install the battery:

  1. Place the battery (use battery pack catalog #9418Z0 only) into the battery compartment
  2.  Carefully connect the connectors on the battery pack to the connectors in the torch
  3.  Replace the bottom housing and replace and tighten the six screws by hand. Do not over tighten!
  4.  YOUR 9415Z0 ARRIVES WITH THE BATTERY PACK
    PARTIALLY CHARGED. BEFORE USE CHARGE THE TORCH FOR AT LEAST 24 HOURS.

Vehicle Installations

The charger base is approved to NFPA vehicular mounting specifications. It is recommended that the charger be mounted onto a horizontal surface to prevent accidental ejection of the torch. The charger can be secured via the four counterbore 3/8ʺ diameter holes located on the top of the front and rear surfaces. Phillips screws are recommended.
A professional auto electrician should be used to wire the charger into the electrical system of a vehicle. Connect the charger to the electrical system of the vehicle so that there is no ignition-related interrupt. This will prevent the charger from rapidly charging the battery pack unnecessarily. When the battery pack is charged, the current draw from the charger in trickle mode will not excessively drain the vehicle’s battery.
Declaration of Conformity Declaration No. 9415-318-501 We, Peli Products, S.L.U., 23215 Early Avenue, Torrance, CA 90505 Declare under our sole responsibility that the following apparatus:

Product Description: Handheld torch
Model Type: 9415Z0
Brand: PeliTM

Is in conformity with the following legislation: ATEX Directive 2014/34/EU. Based on the following harmonized standards: EN 60079-0:2012+A11:2013, EN 60079-11:2012
The following Notified Body has been involved in the conformity assessment process:
Notified Body: UL International Demko A/S, Borupvang 5A , 2750 Ballerup, Denmark

Notified Body No.: 539
Role: Issue of ATEX EU Type Examination Certificate
Certificate No.: DEMKO 14ATEX 1310896X

Additional information:

ATEX Coding: II 1 G Ex ia IIC T4 Ga
Technical File No.: 9415Z02014

Name and position of person binding the manufacturer or authorized representative:

Signature: Piero Marigo
Name: Piero Marigo
Function: Managing Director
Location: Peli Products, S.L.U. 23215 Early Avenue, Torrance, CA 90505
Date: 30-Jul-14

Specific Conditions of Use:

  1. The maximum measured capacitance of exposed metal parts is 13pF.
  2. Approved for use with catalog #9418Z0 NiMH battery pack only.
  3. WARNING! – Do not charge or change batteries in a hazardous area.
    Um=12VDC. The combination of charger and torch has not been evaluated by UL LLC
Model Type: 9415Z0
Certificate: IECEx UL 14.0077X
Standards: IEC 60079-0 Ed. 6, IEC 60079-11  Ed. 6
Coding: Ex ia IIC T4 Ga

Conditions of Safe Use

  1. The LED Head Assembly is covered with conductive coating to avoid build-up of electrostatic charge. The coating is humidity independent and the operating temperature range is up to 155°C. Do not use in a Hazardous Area if the coating is flaking or peeling.
  2.  The maximum measured capacitance of exposed metal parts is 13pF.
  3.  Approved for use with catalog #9418Z0 NiMH battery pack only.
  4.  WARNING! Do not charge or change batteries in a hazardous area.

Other Batteries
For safety information on other battery types, please go to: https://www.peli.com/eu/en/support/flashlight-battery-safety/.
Battery Recycling
ALWAYS dispose of batteries properly at an approved battery recycling center. Failure to do so can be a crime and can lead to the release of harmful toxic materials. Peli has partnered with Call 2 Recycle in the US and Canada to dispose of recyclable batteries. Call 1-800-822-8837 to find a battery recycling center near you.

  • Deep Discharge: The battery has been allowed to discharge most of its capacity to a point beyond which irreparable damage has occurred. See battery specifications for the specific levels.
  • Condition a Battery: Charge your battery to the fullest and then disconnect from charger. Let your light run until it completely drains the battery and turns itself off. Place the light back onto its charger and completely recharge the battery before using it. This conditioning or “cycling” of the battery will help it retain a fuller charge for a longer period of time.

BATTERY SAFETY NOTICE

YOU MUST READ THESE WARNINGS AND INSTRUCTIONS BEFORE USING OR CHARGING YOUR BATTERIES!
WARNING: HANDLE AND STORE BATTERIES PROPERLY TO AVOID INJURY OR DAMAGE.
BATTERIES CAN BE DANGEROUS!
Most battery issues arise from improper handling of batteries, and particularly from the use of damaged or counterfeit batteries. Please review the information below to avoid serious injury and/or damage to your property.
Rechargeable Batteries

  • DO NOT mix old and new batteries.
  • DO NOT mix battery brands/types.
  • When replacing batteries, replace all batteries at the same time.
  • DO NOT open batteries.
  • DO NOT dispose of in fire.
  • DO NOT heat above 75°C.
  • DO NOT expose batteries to water.
  • Insert batteries correctly with regard to polarity (+ and -) marked on the battery and equipment.
  • DO NOT use batteries beyond their expiration date.
  • Hazardous location safety approvals for explosive environments are only valid for the Peli battery pack that is supplied with the torches .
  • For replacement battery packs only use the approved Peli battery pack for the model of the torches that you are using. The use of other battery packs will reduce the performance of the torches, exposure the user or others to serious injury and invalidate the safety approval.
  • Torches should only be charged in a non-hazardous location.
  • Torches should only be charged using the Peli charger base that is supplied with the torches.
  • Torches should be charged and operated between the temperatures shown in table below.
    BATTERY TYPE| CHARGE TEMP| OPERATING TEMP
    ---|---|---
    Lead Acid| —20°C to 50°C (-4°F to 122°F)| —20°C to 50°C (-4°F to 122°F)
    Ni-MH| 0°C to 40°C (32°F to 104°F)| —20°C to 50°C  (-4°F to 122°F)
    Li-Ion and LiFePO4| 0°C to 45°C (32°F to 113°F)| —20°C to 60°C (-4° F to 140°F)
  • DO NOT charge rechargeable alkaline batteries while they are still in the torches. Charging the alkaline batteries while they are still in the torches can cause internal gas or heat generation resulting in venting, explosion or possibly fire which could cause serious injury or property damage.
  • Deep discharge* of the rechargeable battery may cause batteries to vent potentially dangerous gasses and electrolytes.
  • It is advisable to condition* batteries every 3 months. Failure to do so will decrease battery life. Leaving the product unused for long periods of time will decrease battery life. Withdrawal of the charger from the product prior to a ‘READY’ indication will result in inadequate charge.
  • WARNING – DO NOT use Ni-MH rechargeable battery packs for longer than 3 years or 500 charge/discharge cycles, whichever comes first. Using the Ni-MH rechargeable battery packs for longer than 3 years or 500 charge/discharge cycles will reduce the performance of the torches and expose the user to serious injury or property damage.

PELI PRODUCTS, S.L.U.
c/ Provençal, 388, Planta 7
08025
Barcelona, Spain
Tel: +34 934 674 999
Fax: +34 934 877 393
9415-318-501 5-27461 Rev B OC/19
© 2019 Peli Products. All trademarks are registered and/or unregistered trademarks of Peli Products, SLU., its subsidiaries and/or affiliates.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals