DARCO Pneumatic Night Splint Wedge Instructions
- June 4, 2024
- DARCO
Table of Contents
Pneumatic Night Splint Wedge
Instruction manual
Indications
- Plantar fasciitis
- Heel spurs
- Achilles tendon injuries
- Ankle contracture
Contraindications
- Plantar flexion contracture greater than 10°
- Uncontrollable severe plantar flexion spasticity
- Extended weight bearing and ambulation
Cleaning Instructions/Maintenance
- When the cover is slightly dirty, clean it with a damp cloth or a soft brush.
- Allow the cover to air dry only.
Remove the wedges before cleaning (Night Splint Wedge)
Instructions for use – Pneumatic Night Splint
-
Open all straps and place foot in the Pneumatic Night Splint with the ankle positioned at 90˚.
-
Close the middle strap in order to hold the heel in place.
-
Extend the knee to test the fitting of the middle strap. If the heel is slipping inside the
splint, the middle strap is too loose. If the calf is squeezed in, the middle strap is too tight. -
After checking the correct fit of the middle strap, close the remaining straps.
-
To inflate, compress the inflate bulb multiple times until the desired angle is achieved. Caution: DO NOT OVERINFLATE.
-
To deflate, lift the cap, and press the release valve. Failure to deflate before weight bearing will result in irreparable damage to the air bladder.
Instructions for use – Night Splint Wedge
- Open the toe flap and remove the two wedges from the wedge pocket.
- Open all straps and place the foot in the Night Splint Wedge with the ankle positioned at 90˚.
- Close the middle strap in order to hold the heel in place.
- Extend the knee to test the fitting of the middle strap. If the heel is slipping inside the splint, the middle strap is too loose. If the calf is squeezed in, the middle strap is too tight.
- After checking the correct fit of the middle strap, close the remaining straps.
- Use 1 or 2 wedges [Under the direction of a physician or healthcare professional].
- Open the toe flap and insert wedge(s), thin end first.
Caution
Please always follow these instructions for use. In case of pain or swelling,
discontinue use and consult your medical provider immediately. This device is
designed to assist recovery and should be used exclusively under the
instruction of and in consultation with a healthcare professional.
DARCO® International Inc. does not assume any responsibility for the misuse of
the product. It is advisable to wear dressings or socks with the night splint.
Do not drive a vehicle while you are wearing this device. Use extreme caution
when walking on all surfaces when using this device.
Walk more slowly than normal. This device is for single-patient use only.
To the patient/user: This device has been designed and manufactured by DARCO®
International, Inc.
to be state-of-the-art for the treatment of a specific medical condition.
Should any serious incident occur in relation to this device it should be
reported to the manufacturer at the contact information listed on this
document and the proper authority of the country or state where you are
located. When treatment is complete, dispose of this device according to local
laws and ordinances.
Manufactured for:
DARCO® International, Inc.
Made in China
Documents / Resources
|
DARCO Pneumatic Night Splint
Wedge
[pdf] Instructions
Night Splint, Pneumatic Night Splint Wedge, Pneumatic Night, Splint Wedge
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>