Thank you for selecting our super quality dehumidifier. Please be sure to read this manual carefully before using it. If you have any questions, please contact the professional service for help. Keep the manual for further reference.
The dehumidifier will remove excess moisture from the air, creating a comfortable environment for your home and office. Its compact design allows you to easily move it to any room.

PRECAUTIONS

Read the following notices carefully before operating this dehumidifier.
The warnings and notices must be observed effectively to ensure the safety of the operation.

  1. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
    Cleaning and user maintenance shall not be made by children without supervision.

  2. The unit is designed only for use with R-290 (propane) gas as the designated refrigerant. R-290 (propane) is flammable and heavier than air.

  3. The refrigerant loop is sealed. Only a qualified technician should attempt to service!

  4. Do not discharge the refrigerant into the atmosphere.

  5. If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.

  6. The propane gas used in the unit has no odor.

  7. If a leak is detected, immediately evacuate all persons from the store, ventilate the room and contact the local fire department to advise them that a propane leak has occurred.

  8. No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.

  9. Component parts are designed for propane and non-incentive and non-sparking. Component parts shall only be replaced with identical repair parts.

  10. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  11. The appliance shall be disconnected from its power source during maintenance.

  12. Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.

  13. Always use a power outlet that is grounded.

  14. Do not operate with wet hands. Prevent water from spilling onto the unit.

  15. Do not immerse or expose the unit to rain, moisture or any other liquid.

  16. Do not leave the unit running unattended. Do not tilt or turn over the unit.

  17. Do not unplug while the unit is operating.

  18. Do not use an extension cord or an adapter plug.

  19. Do not put objects on the unit.

  20. Do not insert fingers or other objects into the air outlet.

  21. Do not touch the air inlet or the aluminum fins of the unit.

  22. Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.

  23. Ensure the unit is far away from fire, inflammable, or explosive objects.

  24. The unit shall be installed in accordance with national wiring regulations.

  25. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.

  26. The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).

  27. The appliance shall be stored so as to prevent mechanical damage from occurring.

  28. Do not piece or burn, even after use.

  29. Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than 4m².

  30. Compliance with national gas regulations shall be observed.

  31. Keep any required ventilation openings clear of obstruction.

  32. The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.

Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
If you don’t understand something or need help, please contact the dealer services
AFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing a dehumidifier with R290.
Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.
General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.
Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.

The following checks shall be applied to installations using flammable refrigerants:
The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
The ventilation machinery and outlets are operating adequately and are not obstructed;
If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.
Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; that there no live electrical components and wiring are exposed while charging, recovering or purging the system; that there is continuity of earth bonding

SPECIFICATIONS

Model No. ROOMER Smart 25
Power Supply AC220-240V/50Hz
Power Consumption 335W (27 °C, RH 60%)

380W (30 °C, RH 80%)
Rated Current| 2.1A (27 °C, RH 60%)
2.2A (30 °C, RH 80%)
Dehumidifying Capacity| 25L/Day (30 °C, RH 80%)
12L/Day (27 °C, RH 60%)
Water Tank Capacity| 6.5L
Noise Level| ≤45dB(A)
Refrigerant/Charge| R290/75g
Temperature scope of application| 5 °C – 35 °C
Suction Side Pressure| 0.7MPa
Discharge Side Pressure| 3.2MPa
Heat exchanger maximum allowable pressure| 3.2MPa
Airflow| 180 m³/hr
Dimension| 395 × 290 × 653 mm
Net weight| 14.5kg

Note: Specifications subject to change without notice.

APPEARANCE

OPERATION

INSTALLATION

  1. Place the unit on a firm, level surface in an area with at least 30cm of free space around it to allow for proper air circulation.
  2. Never install the unit where it could be subject to:
  • Heat sources such as radiators, heat registers, stoves or other products that products that produce heat.
  • In an area where oil or water may be splashed
  • Direct sunlight
  • Mechanical vibration or shock
  • Excessive dust
  • Lack of ventilation, such as cabinet or bookcase
  • Uneven surface

OPERATING THE DEVICE SAFELY

  • Check the device after unpacking for any damages or scratches on it.
  • Operate this unit in an ambient temperature from 5°C to 32°C.
  • Do not use in the outdoors. This dehumidifier is intended for indoor residential applications only.
  • Do not operate in close proximity to walls, curtains, or other objects that may block inlet and outlet.
  • Keep the air inlet and outlet free of obstacles.
  • Adjusting the wind deflector in the upward direction prior to start up.
  • If tipped more than 45°, allow the unit to set upright for at least 24 hours before start up.
  • Keep doors and windows close for better energy saving.
  • Do not operate or store the unit in direct sunlight or rain.
  • It is normal for air outlet to feel warm to touch after continuous operation on hot days.
  • Empty the water tank before moving the device.
  • Make sure the water tank is correctly fitted otherwise the unit will not operate properly.
  • The dehumidifier starts up in the mode selected when the unit was last used.
  • The dehumidifier starts dehumidifying if the room humidity is 3% higher than the selected humidity.
  • There is a protective 3-minutes time delay of the compressor. Wait 3 minutes for the dehumidifier to resume dehumidification.

DIGITAL DISPLAY
Ambient humidity < 45%, it shows blue 45% ≥ ambient humidity ≤ 65%, it turns green ambient humidity > 65%, it displays red

CONTROL PANEL

POWER
When you plug in the unit, a beep sounds and the “POWER”LED lights up.
Press the on/off switch to turn the unit on; the dehumidifier starts with the settings (except the timer setting) of the last operation.
Press the on/off switch again to switch the unit off. The compressor switches off immediately and the fan switches off with a delay of 30 seconds.
After a power failure, the unit restarts automatically with the settings (except the timer setting) of the last operation.

MODE
Auto mode Auto
The unit is equipped with a modern hygrostat (humidity controller) and switches off automatically after reaching the desired humidity in order to save energy. The compressor switches off first and then the fan 30 seconds later. When the humidity in the room rises again, the dehumidifier switches on automatically.
When automatic mode is activated, the target humidity can be set between 30% and 80% in 5% steps using the two arrow keys.
The dehumidifier starts dehumidifying when the room humidity is at least 3% higher than the set target humidity.
Continuously drying mode ****
In continuous operation, the unit works continuously until the water tank is full or the dehumidifier is switched off manually.
In this mode, the unit operates at maximum air output to dehumidify the room air as quickly as possible.
During operation, the current humidity is shown on the display.

TIMER
Press the timer key to start the timer function. Then use the two arrow keys to set the desired run/start time from 1-24 hours. If the timer is activated, this is indicated by the corresponding LED.
If you activate the timer during operation, the appliance switches off after the set time.
If you activate the timer while the unit is in standby mode, the unit will start automatically after the set time has elapsed.
To switch off the timer, press the key again and set the running time to “00” using the two arrow keys.
If the unit is switched off via the on/off switch, the timer function is also deactivated.
Note: when press POWER will also exit the timer setting.

SPEED
The fan speed can only be changed in automatic mode.
Press this button to switch between the two fan speeds.
The currently selected fan speed is displayed via the two LEDs.
Increase
Press this button to set up humidity and timing time;
Humidity adjusting the order of 30% to 35% – 40% – 45% – 50% – 55% – 60% -– 65% – 70% – 75% – 80% – 30%;
Time set to 00, press this key, display 00 and blink, then press this key again every time, from 01-02-03-…… to 24.
Decrease
Press this button to lower humidity setting and timing time;
Humidity adjusting the order of 30% to 80% – 75% – 70% – 65% – 60% – 55% – 50% – 45% – 40% – 35% – 30%;
Time set to 00, press this key, display 00 and blink, and then press this key again every time, from 24-23-22-…… to 00.

CHILD-LOCK (LOCK)
When the machine is turned on, press the button for 3 seconds to open/close the child lock function. When the button is turned on, the indicator light of the child lock is on. The indicator light of child lock is off; After the child lock function is opened, the child lock function will be cancelled automatically as long as the shutdown or power failure occurs.
SLEEP / RESET
Press this button **** to switch the sleep function on or off.
In “Sleep”mode, the unit operates at a low fan speed with a fixed target humidity of 60%.
When the mode is active, the indicators for the sleep function, the child lock and power are dimmed. All other displays go out.
Activate the timer before you start the sleep function and the dehumidifier will switch off after the set runtime.
If the filter indicator lights up , the dust filter must be checked/cleaned/replaced.
Then the display can be reset by pressing and holding (at least 3 seconds) the Sleep / Reset button.

INFORMATION ON THE APP “MYCOND”
The “Mycond” app is available for android and iOS.
Scan the corresponding QR code to get directly to the download.

https://a.smart321.com/comMycond

INFORMATION ON HOW TO USE THE APP
This appliance allows you to operate the appliance via your home net-work. A prerequisite is a permanent Wi-Fi connection to your router and the free app “Mycond”.
We recommend disconnecting the appliance from the power supply when you are away from home to prevent unintentional switching on while you are on the road!

Commissioning via the App

  1. Install the “Mycond” app. Create a user account.
  2. Activate the Wi-Fi function in the settings of your appliance.
  3. Place the appliance at a distance of about 5 meters to your router.
  4. As long as the power is turned on, the Wi-Fi indicator flashes slowly. After 3 minutes, the status will be canceled if there is no network configuration, and the indicator light is off. If you need to re-connect the Wi-Fi, long press the “timer” button for 5 second to start the network configuration, the Wi-Fi indicator flashes slowly.
  5. When Wi-Fi indicator flashes slowly, select “Add Device” – “Dehumidifier”, and follow the instructions on the display.
  6. Once the appliance has been successfully connected, the Wi-Fi lamp lights up. Now you can operate the appliance using the app.
  7. Press and hold the Timer button for about 5 seconds, the appliance disconnect, the Wi-Fi lamp lights off.

TROUBLE SHOOTING

Network connection failed Solution
Network connection timeout 1.Check if you selected the correct Wi-Fi.

2.Turn off the machine and unplug the power code and plug in after 10 seconds, enter the App to connect again.
Wi-Fi indicator off| Long press the “Timer” button or turn off the machine and unplug the power code and plug in after 10 seconds.
Wi-Fi hotspot disappear and the Wi-Fi light flash| Turn off the machine and unplug the power code and plug in after 10 seconds, enter the App to connect again.

MAINTENANCE

DRAINAGE
There are two ways of removal collected water produced by the unit.

  1. Manual draining: Empty water tank by manual.
  2. Continuous draining: Use gravity to drain condensate water by attaching a drain hose.

EMPTYING THE WATER TANK
The water tank built in unit will fill up and shut the unit down once it is full. It will run again once you empty the water tank and installed properly.

  1. When the tank is full, the unit will make a buzzing sound, and the “Water Full” light will turn on.
  2. Press the POWER button to turn off the unit.
  3. Pull on the water tank and simply slide out of the body of the dehumidifier.
  4. Empty the water into an area with a drain or outside.
  5. Clean the inside of the tank as well as the outside.
  6. Replace the empty tank back into the unit.
  7. Press the POWER button to resume operating.
  8. If the “Water Full” light does not extinguish, check that the float is correctly in place.

WARNING!

  1. Do not discard the magnets and plastic rivets in the tank. Otherwise, the dehumidifier cannot be started, or the machine will not automatically stop working when the water tank is full, and the condensed water overflow will damage the floor of the room.
  2. Please make sure to clean the condensed water in the tank and put the tank in the original position.
  3. If the water tank is dirty, please rinse it with clean water. Avoid using detergents, steel wire balls, chemical dust removers, diesel, benzene, diluents or other solvents. Otherwise, it can damage the tank and cause leaks.
  4. Put the water tank in its original position. Otherwise, the indicator light will always be red and the machine cannot start working again.

CONTINUOUS DRAINAGE

  1. Take out the PVC pipe, straighten the drain pipe.
  2. Insert one end of the drain pipe into the drain outlet at the top of the tank and connect the other end to the bathroom, floor drain, outdoor or bucket like container, defined drain area.

WARNING!

  1. Please do not block the drain or drain pipe, if blocking phenomenon, condensed water will flow into the tank.
  2. Please do not bend the drain pipe. The height of the drain pipe should be lower than the outlet.
  3. The drain pipe must be firmly connected to the outlet.

CLEANING THE AIR FILTER (EVERY TWO WEEKS)
Note: before cleaning and maintaining the machine, please be sure to turn off the machine and unplug the power to avoid electric shock.
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.

TROUBLESHOOTING

Problem Possible Cause Solution
The unit is not operating. Check the power connection in securely. Insert

the power cord securely into the wall outlet.
Check if the water level indicator lights up.| Empty the water tank and reinstall correctly.
Check the room temperature.| The range of operating temperature is 5-35 °C.
There is little formation of condensate.| Check the air filter for dirt.| Clean the air filter as necessary.
Check if the air duct is blocked.| To clear the obstacle.
Check if the room temperature is below 20 °C.| This is normal. Low humidity in low temperature environment.
Set humidity level is higher than current Humidity value.| Set the humidity level below current humidity value.
Water Leakage| Overflow while moving the unit.| Empty the water tank before transport.
Check if the drain hose is kinked or bends.| Straighten the hose to avoid a trap existing.
Excessive Noise| Check if the unit is securely positioned.| Place the unit on horizontal and firm ground.
Check if any loose, vibrating parts.| Secure and tight the parts.
Noise sounds like water flowing.| Noise comes from flowing refrigerant. This is normal.

Error code

E2| Humidity sensor dampened or failure.| To clean or replace the humidity sensor.
---|---|---
CL| Display when Room temperature is below 5 °C (41 °F).| Normal. The compressor stops, and the fan keeps running.
CH| Display when Room temperature is above 35 °C (95 °F).| Normal. The compressor stops, and the fan keeps running.
LO| Display when Room relative humidity is bellow 20%RH.| Normal. The compressor stops, and the fan keeps running.
HI| Display when Room relative humidity is above 90%RH.| Normal. The compressor and the fan keep running.

CAUTIONS:

  • Switch off the unit and unplug it immediately if you notice something abnormal in the operation of the device.
  • Then contact a qualified electrician.
  • Do not dispose of electrical appliances as unsorted municipal waste, use special collection facilities.
  • Contact your local authorities for information on available collection facilities.
  • Releasing refrigerant into atmosphere is strictly forbidden! According to European Directive 2012/19 / EU on waste electrical and electronic equipment and transposition into national law, used electrical appliances must be collected separately and recycled in an environmentally sound manner.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MYCOND User Manuals

Related Manuals