Tamarack Solar Products Flush Mount Solar Roof Mount System for 8 Rail Kit Instruction Manual
- June 10, 2024
- Tamarack Solar Products
Table of Contents
- Tamarack Solar Products Flush Mount Solar Roof Mount System for 8 Rail
- Tamarack Flush Mount System Features
- Tamarack Flush Mount 84-inch Rail Kit
- Leveling Rails
- Product Tamarack Flush Mount System Features
- Tamarack Product Summary
- Tamarack Flush Mount 84-inch Rail Kit
- Torque Specifications
- Prepare for Installation
- Grounding
- Module Level Power Electronics
- Wire Management
- Module Installation
- Channel End Clamps
- Installers Responsibilities
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Tamarack Solar Products Flush Mount Solar Roof Mount System for 8 Rail
Kit
Tamarack Flush Mount Solar Roof Mount System
Installation Features and Ratings
- Class A Fire Rating per UL 1703 for steep roof slope applications when ETL Listed to UL 2307 for bonding and grounding when installed in accordance with this manual.
- Rails, clamps, splices, and mounting devices are UL2703 Listed for
Tamarack Flush Mount System Features
- Tamarack Product Summary
- Complete the installation in less time.
Tamarack Flush Mount 84-inch Rail Kit
The kit includes
- Eight rails for attractive low-profile flush mount installation of solar panels
- 50-50 clamp
- Push-In Bonding Rail Splice
- Rail Mount and L-Foot
- Push-On End Cap
- Wire Management Clip
- Eight caps, for two rows give Ground lug
- Channel End Clamp
- MLPE Adapter
Tools Required
You will need:
- A torque wrench
- A drill with a 5/32” bit (for wood) or 1/4” bit (for metal)
- A tape measure and marking tools
- A string level or straight edge
Prepare for Installation
The rails can be installed parallel or perpendicular to the roof rafters. Center the rails over the structural members as much aspossible. Leave enough room to work safely around the array during the installation process. Some building codes may require additional clearances. The length of the rails for each row in the installation will be equal to the total width of the clamping. When using the channel end clamp, rails can be cut to the edge of the array. Allowable spans between roof supports are 6 feet.
Attach Rail Mounts
Attach Rail Mounts using off-the-shelf mounting products that have vertical leveling slots. Tamarack recommends using Rail Mount Q Blocks. Rail Adapters may be installed anywhere on the rails, including at splices, and they will not interfere with module mounting clamps.
Install Rails
Install Rails to mount eight 60 cell or 72 cell modules with a width of up to 42”. When mounting modules in landscape orientation,the number of modules you can mount with this kit will vary with module length. Use a Tamarack bonding splice to connect each section of rail in a row. Each section of rail at the end of a row must be supported by two mounts before being spliced.
Rail mounting is simple and easy. The Rail Adapter clamps to the two feet on the bottom of the rail. There is never any drilling,and parts can be brought on the roof fully assembled and ready to be installed. Simply position the adapter into the two feet on the bottom of the rail, and tighten the bolt of the middle mount.
Leveling Rails
Leveling Rails is important for proper installation. Tamarack recommends placing the Rail Adapters near the middle of the leveling range and adjusting as necessary to have visually levelrails. Level the top rail of the array in the same manner. Use a string level or straight edge to help adjust the remaining rails. It is possible to visually align rails in the middle of the array.
Product Tamarack Flush Mount System Features
- Designed for mounting on most residential roofs
- Can be installed with most available roof attachments for composition shingle, tile and metal roofs
- Only 4 tools required for installation
- Top clamps and rail attachments require the use of a single standard 1/2-inch socket
- One part for both mid-clamp and end-clamp use simplifies ordering and stocking parts
- Module clamps are spring loaded to ease module placement
- Two rail heights and one rail length
- Bonding splice installs easily without tools
- Built-in wire management for module and microinverter cables
- Sleek low-profile design eliminates the need for an array skirt
Tamarack Product Summary
Flush mount is a visually appealing, low profile, photovoltaic (P) module
installation system that significantly lowers PV module installation cost by
allowing the installation professional to stock fewer parts and to complete
the installation in less time.
Certified to meet local and International Building Codes when installed in
accordance with this manual. The design load rating meets the minimum
requirements of 10 PS downward pressure, 5 PSF upward pressure and 5 PSF down-
slope load. Module orientation may be portrait or landscape. Designed for use
with most third-party roof attachments including Solar Roof Hooks, Quick Mount
PV, Ironridge Flashfoot, S-5 Clamps, etc.
Class A Fire Rating per UL 1703 for steep roof slope applications when using
Type 1 or Type 2 Listed Photovoltaic Modules. This is per Middle- ton fire
test report 103427989MID-004.
ETL Listed to UL 2307 for bonding and grounding when installed in ac- cordance
with this manual.
Rails, clamps, splices and mounting devices are UL2703 Listed for mounting
flat-plate Photovoltaic Modules and Panels
Tamarack Flush Mount 84-inch Rail Kit
Install Eight Typical PV modules
-
Mill Finish Rails
Eight rails for attractive lowprofile mounting of up to eight modules with four-foot roof attachment spacing. Certified for up to 180 MPH wind speed and 120 PSF snow load. -
Push-In Bonding Rail Splice
Quickly splice and bond rail sections with no tools or fas- teners. Top Clamps and Rail Mounts can be co-located with splice. Eight splices included. -
50-50 Clamp
One clamp can be used as a mid-clamp or an end-clamp on modules with 30 mm to 40 mm frame height.
Twenty clamps are included. -
Rail Mount and L-Foot
Quickly and securely mount the rail from either side, to any L-Foot, Tile Hook or specialty flashing with a hole or slot for a 5/16-inch bolt. 16 mounts are included. -
Push-On End Cap
Eight caps, for two rows give the rail system a finished look while allowing drainage. -
Wire Management Clip
Kit includes 24 clips that can be pushed into top of rail to keep cables in place. -
Ground lug
Use one per module row to ground rail with bare 6 to 10 AWG copper wire. Four clamps are included. -
Channel End Clamp
Use this end clamp for mounting modules flush with the end of the rails. This end clamps replaces 50/50 clamps at the end of the row. Eight clamps are included in the kit. -
MLPE Adapter
Attach microinverters or power optimizers to the rails under the modules. Use one adapter for each device. Eight adapters are included.
Tools Required
- Cordless Drill
- Torque Wrench
- Rachet and 1/2″ Socket
- Level
Torque Specifications
- Rail Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ft-lbs
- MLPE Rail Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ft-lbs
- Ground Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ft-lbs
- 50-50 clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ft-lbs
- Rail Ground Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ft-lbs
- Ilsco SGB-4 Module Frame Ground lug . . . . . . . . . . . . . . . . . . . . . 12 ft-lbs
Prepare for Installation
Plan the PV module layout that fits the roof and confirm that plans comply
with local AHJ requirements.
The rails can be installed parallel or perpendicular to the roof rafters.
Center the rails over the structural menbers as much as possible.
Leave enough room to work safely around the aray during the installation
process. Some building and fire codes require minimum clearances around PV
module installations.
The length of the rails for each row in the installation will be equal to the
total width of the modules plus 1/2-inch for each 50-50 clamp used between
modules plus 2-inches total for end clamping. When using the channel end
clamp. rails can be cut to the edge of the arrav. Install proper roof mount
flashings per the manufacturer’s instructions. The maximum allowable spans
between roof supports is 6 feet.
Attach Rail Mounts
Each Rail-Mount consists of two parts, a 5/16 inch bolt and a clamp extrusion.
The rail adapters have been designed to interface with off-the-shelf mounting
products that have vertical leveling slots. Our Rail Mounts work with most
products that have 5/16 inch or 3/8 inch bolt slots. We also offer our own L
foot for mounting to products that have a flat mounting surface, such as seam
clamps, exposed beams or Quick Mount O Blocks.
Install Rails
This kit contains eight 84-inch rails. This is enough to mount eight 60 cell
or 72 cell modules with a width of up to 40.5 inches in portrait orientation.
If you are mounting modules in landscape orientation, the amount of modules
you can mount with this kit will vary with module length.
Use a Tamarack bonding splice to connect each section of rail in a row.
If a cut section of rail is required for the installation, it must not be
installed at the end of a row.
Each section of rail at the end of a row must be supported by two mounts
before being spliced.
If a rail section has a splice and 3 roof mounts, the splice should be located
within 1/3 rail span of the middle mount.
Rail mounting is simple and easy.
The Rail Adapter clamps to the two feet on the bottom of the rail.
There is never any drilling, and parts can be brought on the roof fully
assembled and ready to be installed. Rail Adapters may be installed anywhere
on the rails, including at splices and they will not interfere with module
mounting clamps.
Simply position the adapter into the two feet on the bottom of the rail, and tighten the bolt slightly. Leave the bolt slightly lose to allow leveling of the rails in the next step.
Leveling Rails
Start by leveling the bottom rail of the array first. Set the Rail Adapters
near the middle of the leveling range and adjust as necessary to have visually
level rails.
Tighten the attachment bolts to the specified torque when they are aligned.
Level the top rail of the array in the same manner.
If there are multiple rows of rails in the array, use a string level or
straight edge to help adjust the remaining rows to be level with the top and
bottom rails. It is also possible to visually align rails in the middle of the
array.
Tighten all hardware to the specified torque.
Grounding
Tamarack rails and PV modules are bonded by 50-50 Module Clamps and bonding
splices.
The 50-50 clamps acheive bonding to the module frames by stainless-steel pins
in the clamping surface of the clamp tops, which penetrate module frame
coating. The rails and channel nuts are bonded because of the conductive
surface of the mill finish aluminum used in the rail construction.
SolarEdge Optimizers and Enphase Microinverters are bonded to the rail with
the Tamarack
MPLE adapters.
Bonding Method 1: Rail Lug
Use a Ground Clamp to bond a ground conductor to a rail.
Bonding Method 2 (Optional): Frame Lug
Use a module ground lug to bond a module frame to a ground conductor. The
resulting system is bonded primarily through the module frames. This method
may not be acceptable to all building inspectors. This lug is not included in
the kit.
Grounding Diagrams
Rail Grounding method
Frame Grounding Method
Rail Grounding method with SolarEdge Optimizers
Frame Grounding method with SolarEdge Optimizers
Module Level Power Electronics
Use the Tamarack MLPE Rail
Adapter to attach Enphase microinverters or SolarEdge Optimizers to the rails.
The large flat washer is installed between the mounting plate of the MLPE and
the top of the rail.
Tighten the bolt to 12 ft.-Ib. with a torque wrench and a 1/2-inch socket.
Wire Management
Place electrical conductors and connectors at the bottom of the rail channels.
Install the wire protection clips where necessary to keep wires in the
channels.
When using 1.6 inch rail, it is possible to damage connectors or large bundles
of wire when 50-50 bolts are tightened. Position connectors and bundles
appropriately to prevent risk of ground faults.
NOTE
These kits may have extra parts that will not be needed in some situations
Module Installation
Start module installation at one end of the rails. If there are multiple rows,
start on the bottom row.
Install a 50-50 clamp at the end of each rail with the side of the clamp with
2 bonding pins on the module frame.
Push the channel nut into the rail. The integrated spring assembly will hold
the clamp in place.
Place the first module onto the rails so that it is centered over the rails. Make sure the module is touching the inside edge of the clamps and tighten the clamps with a 1/2″ socket.
Install 50-50 Clamps in each rail on the other side of the first module. The
springs will hold the clamps in place prior to tightening. Place the second
module on the rails, align it with the first module, and push in against the
clamps. Tighten the clamps to fully secure the module.
Install the remaining modules and clamps on the rails in the same manner,
aligning the corners of the modules.
Do a final check to be sure that all installation hardware on the array is properly tightened to 12 ft. Ibs.
Channel End Clamps
Channel End Clamps may be used in place of the 50-50 clamps at the ends of
rails. Channel Clamps secure the module frame from below and allow the rails
to be cut flush to the edge of the array for a clean look.
Insert channel end clamp in the rail. The module must be lifted slightly to
slide the clamp under the frame. Allow the module to rest on the rail again
and slide the clamp back toward the end of the module until it is flush with
the outside end of the module frame and tighten lightly.
Feel under the array to check that the clamp is clamping the module flange
securely, then tight- en to 12 ft. Ibs.
End Caps
Place an end cap at the end of each rail to inprove the look of the system.
Drain holes on the bottom of the end caps ensure that water does not
accumulate in the rails.
Disclaimer
This manual describes proper installation procedures and provides necessary
standards required for product reli- ability. Warranty details are available
on our website. www.tamaracksolar.com
All installers must thoroughly read this manual and have a clear understanding
of the installation procedures prior to installation. Failure to follow these
guidelines may result in property damage, bodily injury or even death.
Installers Responsibilities
-
Follow all applicable local or national building and fire codes, including any that may super sede this manual.
-
Electrical installation should be conducted by a licensed and bonded electrician or solar con tractor.
-
Module maintenance or removal must not break the bonding path of the system.
-
Ensure all products used are appropriate for the installation and array under the site’s loading conditions.
-
Use only Tamarack parts or parts approved by Tamarack; substituting parts may void any ap plicable warranty.
-
Comply with all applicable fire codes including, but not limited to, keeping walkways clear.
-
Ensure bare copper grounding wire does not contact aluminum and zinc-plated steel compo nents, to prevent risk of galvanic corrosion.
-
If loose components or loose fasteners are found during periodic inspection, retighten imme diately. If corrosion is found, replace affected components immediately.
-
Provide an appropriate method of direct-to-earth grounding according to the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, NEC 690: Solar
Photovoltaic Systems, and CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1 -
Disconnect AC power before servicing or removing microinverters and power optimizers.
-
Review module manufacturer’s documentation to ensure compatibility and compliance with warranty terms and conditions.
-
Maximum Series Fuse Rating of 20 Amps.
Technical Support: 707-234-8107 or 800-819-7236 ext.556
Certified Module List for UL2703 Listing Program
Manufacturer | Model |
---|---|
Aleo | P18/P19/S18/S19/S59/S79. |
AU Optronics | PM Series |
Astronergy | CHSM6612M, CHSM6612M/HV, CHSM6612P, CHSM6612P/HV, CHSM6610M (BL) |
(BF)/(HF), CHSM6610M/HV, ASM3310P
Auxin| AXN6M610Txxx, AXN6P610Txxx, AXN6M612Txxx, AXN6P612Txxx.
Axitec| AXIblackpremium 60 (35mm), AXIpower 60 (35mm), AXIpower 72 (40mm),
AXIpremium 60 (35mm), AXIpremium
72 (40mm).
Boviet| BVM6610, BVM6612, BNM6612
BYD| P6K Series (35mm), MHK-36
Canadian Solar
| CS6V-xxxM, CS6P-xxxP, CS6K-xxxM, CS5A-xxxM, CS6K-xxxMS CS6U-P, CS6U-M, CS6X-P, CS6K-MS, CS6K-M,
CS6K-P, CS6P-P, CS6P-M, CS3U-P, CS3U-MS, CS3K-P, CS3K-MS, CS1K-MS, CS3K, CS3K, CS3U, CS3U-MB- AG, CS3K-MB-AG, CS3K-MB-AG, CS6K, CS6U, CS3L, CS3W, CS1H-MS, and CS1U-MS
CentrsoSolar America| C and E series.
Certainteed| CTxxxMxx-01, CTxxxPxx-01, CTxxxMxx-02 Where “xx” denotes frame
and backsheet color.
CT-03 Series
Dehui| DH-60M xxx-xxxW
Eco Solargy| ORION 1000 ECOXXXH156P-60, APOLLO 1000 ECOXXXT156M-60, and APOLLO
1000 ECOXXXA156M-60.
ET Solar| ETAC Module, ET Module.
GCL
| 40mm frame: GCL-P6/72
35mm frame: GCL-P6/72, GCL-P6/72H, GCL-M6/72, GCL-M6/72H
35mm frame (Black frame): GCL-P6/60, GCL-M6/60
Hansol| TD-AN3 (40mm), TD-AN4, UB-AN1 (35mm), UD-AN1 (40mm), UB-AN1, UD-AN1
Heliene| 36M, 60M, 72M, 60P, and 72P.
HT Solar| HT60-156(M) (NDV) (-F), HT 72-156(M/P)
Hyundai| HI, KG, MG, TG, RI, RG, TI, MI, KI series (35mm and 40mm).
ITEK| iT-xxx, iT-xxx-HE, iT-xxx-SE, iT-xxx-SE-72 (40mm).
JA Solar
| JAP6 60-xxx, JAM6-60-xxx/SI, JAM6(K)-60/xxx, JAP6(k)-72-xxx/4BB, JAP72SYY- xxx/ZZ, JAP6(k)-60-xxx/4BB, JAP60SYY-xxx/ZZ, JAM6(k)-72-xxx/ZZ, JAM72SYY- xxx/ZZ, JAM6(k)-60-xxx/ZZ, JAM60SYY-xxx/ZZ, JAM 72S09,
JAM72S10, JAP72S10, JAM60S10, JAP60S10
i. YY: 01 white backsheet, 02 black backsheet, 03 half-cell and white backsheet, 09 M4 cell, 10 M4 1/2 cell
ii. ZZ: SC standard cell, PR = perc, BP = bifacial, HiT = HIT, IB = IBC, MW = MWT
Japan Solar| JPS-xxxP-60 (35mm), JPS-xxxM-60 (35mm), JPS-xxx-P-72 (40mm), JPS- xxxM-60-BB (35mm), JPS-xxx-P-72-BB
(40mm)
Jinko
| JKM xxx P-60, JKM xxx PP-60, JKM xxx M-60, JKM xxx M-60B, JKMS xxx PP-60
JKMS xxx P-60, JKMSxxx-72, JKMxxxP-72, JKMSxxxP-72, JKMxxxM-72, JK07A (JKMSxxxPP-60 & JKMSxxxPP- 72), JK07B (JKMSxxxPP-60), JKM xxx PP-60(Plus), JKM xxx PP-60B, JKM xxx M-60B, JKMSxxxM-60, JKMSxxxM-
60-EP, JKM xxx P-72B, JKMxxxPP-72, JKMxxxPP-72B, JKMxxxPP-72(Plus), JKMSxxxPP-72, JKMxxxM-72-V,
JKMxxxPP-72-V, JKMxxx-72L-V, JKMxxx-72HL-V, JKMxxxM-60L, JKMxxxM-60BL, JKMxxxM-60HL, JKMxxxM- 72HL-V, JKMxxxM-72L-V
Hanwha Q-Cells
| G3, L-G4 and L-G2, Q.PLUS G4 xxx, Q.PLUS BFR G4.1/TAA xxx, Q.PLUS BFR, G4.1/MAX xxx, Q.PLUS BFR G4.1 xxx, Q.PRO-G4 xxx, Q.PRO EC-G4.4 xxx, Q.PRO BFR G4 xxx, Q.PRO BFR G4.1 xxx, Q.PRO BFR G4.3 xxx, Q.PEAK-G4.1 xxx
Q.PEAK- G4.1/MAX xxx, Q.PEAK BLK G4.1 xxx, Q.PEAK-G4.1/TAA xxx
Q.PEAK BLK G4.1/TAA xxx, B.LINE PRO BFR G4.1 xxx, B.LINE PLUS BFR G4.1 xxx, B.LINE PRO BFR G4.1 xxx, Q.PEAK DUO-G5-xxx, Q.PEAK DUO-G5.X-xxx and Q.PEAK DUO BLK-G5-xxx
Q.PEAK L G4.2, Q.PLUS L G4.2, Q.PLUS L G4.1 -35mm, Q.PLUS L G4 – 35mm, Q.PRO L G4 -35mm, Q.PRO L G4.1 – 35mm, Q.PRO L G4.2 – 35mm, B.LINE PLUS L G4.2 – 35mm, B.LINE PRO L G4.1 – 35mm, B.LINE PRO L G4.2 – 35mm, Q.PLUS L-G4.2/TAA -35mm, Q.PEAK DUO L-G5.2, Q.PEAK DUO L-G5.3 (380-395), Q.Peak Duo L-
G6 xxx, Q.Peak Duo L-G6.2 xxx, Q.Peak Duo L-G6.3 xxx, Q.Peak Duo G6 xxx, Q.Peak Duo BLK-G6 xxx
32mm high frame profile: Q.PEAK DUO-G7, B.LINE PEAK DUO-G7, Q.PEAK DUO-G7.2, B.LINE PEAK DUO- G7.2, Q.PEAK DUO L-G7, Q.PEAK DUO L-G7.1, Q.PEAK DUO L-G7.2, Q.PEAK DUO L-G7.3, B.LINE PEAK DUO L-G7, B.LINE PEAK DUO L-G7.1, B.LINE PEAK DUO L-G7.2, B.LINE PEAK DUO L-G7.3, Q.PEAK DUO-G8,
Q.PEAK DUO BLK-G8
Kyocera| KU26x-6MCA where x is 0 or 5.
LG
| MONO X, MONO X 2, Mono X Plus, Mono Neon 2, Mono Neon 2 LG xxx S1C-L4, LG xxx N1C-G4
LG xxx S1C-A5, LG xxx N1C-A5, LGxxxQ1C(Q1K)-A5, LGxxxN1C(N1K)-A5, LGxxxS1C-A5, LGxxxA1C-A5, LGxxxN2T-A4, LGxxxN2T-A5, LGxxxN2W-A5
LGxxxS2W-A5, LGxxxE1C-A5, LGxxxN1C(N1K)-G4, LGxxxN2W-G4, LGxxxS2W-G4
LGxxxS1C-G4, LGxxxE1K-A5, LGxxxN1K-V5, LGxxxN1C-V5, LGxxxQ1C-V5, LGxxxN2W-V5
LONGi
| LR6-60 (40mm), LR6-72 (40mm), LR6-60 HV (40mm), LR6-72 HV (40mm), LR6-60 PH (40mm), LR6-72 PH (40mm), LR6-60 PE (40mm), LR6-72 PE (45mm), LR6-60 BK (40mm Black frame), LR6-72 BK (40mm Black
frame), LR6-60 PB (40mm Black frame), LR6-72 PB (45mm Black frame) Number in paranthesis signifies frame
profile height.
Mission Solar | MSE series |
---|---|
Mitsubishi | MJE, MLE |
NSP | D6M and D6P |
Panasonic | VBHNxxxSA16/VBHNxxxSA16B, VBHNxxxSA15/VBHNxxxSA15B, VBHNxxxKA01, |
VBHN SA17/18/KA03/04, VBHNxxxSA17G, VBHNxxxSA17E/18E, VBHNxxxZA01,
VBHNxxxZA02, VBHNxxxZA03, VBHNxxxZA04.
Peimar| SGXXXM (FB), SGXXXM (BF), SGXXXM
Phono Solar| PS-xxx-60, PS-xxx-72
Risen| RSM72-6 (MDG) (M), RSM60-6
REC Solar| PEAK Energy Series, PEAK Energy BLK2 Series, PEAK Energy 72 Series,
TWINPEAK 2 SERIES
TWINPEAK 2 BLK2 SERIES, TWINPEAK SERIES, alpha Series
Renesola| Virtus II with module ratings of 250-260 in increments of 5.
156 series with module ratings of 270-275.
S-Energy| SN3xxM-10/SN3xxP-10 (40mm), SNxxxM-10/SN2xxP-10 (40mm), SNxxxP-15 (40mm)
Seraphim
| SEG-6PA-XXXWB (XXX=280 to 335), SEG-6PA-XXXBB (XXX=280 to 335), SEG-6PB- XXXWW (XXX=240 to 275), SEG-6PB-XXXWB (XXX=240 to 275),SEG-6PB-XXXBB (XXX=240 to 275), SEG-6MA-XXXWW (XXX=290 to 370), SEG-6MA-XXXWB (XXX=290 to 370), SEG- 6MA-XXXBB (XXX=290 to 370), SEG-6MB-XXXWW (XXX=250 to 305)
SEG-6MB-XXXWB (XXX=250 to 305), SEG-6MB-XXXBB (XXX=250 to 305) SEG-E01A-XXX (XXX=325 to 400), SEG-E01B-XXX (XXX=275 to 330) SEG-E11A-XXX(XXX=325 to 385), SEG-E11B-XXX(XXX=275 to 320)
SRP-XXX-6QA-WX-XX (XXX=345 to 370) (XX=40 or 50 mm) (X=B or S for Black or Silver frame), SRP-XXX-6QA- BX-XX (XXX=345 to 370) (XX=40 or 50 mm) (X=B or S for Black or Silver frame), SRP-XXX-6QB-WX-XX (XXX=280 to 300) (XX=40 or 50 mm) (X=B or S for Black or Silver frame), SRP-XXX-6QB-BX-XX (XXX=280 to 300)
(XX=40 or 50 mm) (X=B or S for Black or Silver frame)
Sharp| 60 and 72 NUSA-xxx/NUSC-xxx
Silfab| SLA-M and SLG-M
SolarWorld| Sunmodule Protect, Sunmodule Plus
Solaria
| PowerXT-xxxy-zz, PowerXT-xxxR-PD/BD, PowerXT-xxxR-AC, PowerXT-xxxC where: xxx is power in watts y is module size (R for residential, C for commercial), zz is other
PowerXT-xxxy-zz all share the same rail profiles
Sonali| SS 230 – 265
SunEdison/
Flextronics
| F-Series / FXS, R-Series / FXS
Suniva| MVX xxx-60, OPT xxx-60-4-100
Sunpower
| E20-xxx-COM, X21-xxx, X22-360-C-AC.
Evaluated with both the G3 and G5 frame SPR-P17-xxx-COM
(xxx: module power rating)
SunSpark| 40mm high frame profile: Mono module 60P (xxxW), Mono Module 72P
(xxxW)
Suntech| STP 35/40
Talesun
| TP572, TP596, TP654, TP660 (35mm/40mm), TP672, Hipor M350+ (40mm)
Talesun Smart (35mm) M = Mono, P = Poly, B = Black, T = Transparent
(H) = 1500V, without (H) is 1000V
Tesla/ZEP/SolarCity| SCxxx, SCxxxB, SCxxxB1, SCxxxB2
Trina Solar| TSM-xxx PA05.08, TSM-xxx PD05.10, TSM-xxx PD05.08, TSM-xxx
DD05.08
TSM-xxx DD05A.05(II), TSM-xxx DD05A.05(II), TSM-DD14/PE14/PD14, TSM- DE14
Upsolar| UP-MxxxP, UP-MxxxP-B, UP-MxxxM, UP-MxxxM-B
URE| D7MxxxH8A, D7KxxxH8A, D7MxxxH7A
Vikram| Eldora Grand Ultima, Eldora Grand, Eldora Prime, Eldora Ultima,
Solivo, Somera Grand, Ultima, Somera Grand,
Somera Half (VSMH.72), Somera Prime, Somera Ultima
Yingli| YL xxx P-29b, YLM 60, YLM 72, YGE, YGE-VG, YLM, YL xxx P-35b, YL xxx
D-30b, YL xxx D-36b
Waaree| AC, Adiya 60/72 Mono/Poly Black, Adiya 60/72 Multi
Winaico| WST (35mm), WSP (40mm)
SolarEdge| P400J, P600, P700, P730, P800p, P800s
---|---
Enphase| M250-72, 250-60, M215-60, C250-72, S230, S280, IQ 6, IQ 6+, IQ 7, IQ
7+, IQ 7X, Q Aggregator
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>