Hard Head 021093 Water Heater Instruction Manual
- June 4, 2024
- Hard Head
Table of Contents
WATER HEATER
OPERATING INSTRUCTIONS
Original instructions
021093 Water Heater
021093
Jula AB reserves the right to make changes to the product. Jula AB claims copyright on this documentation. It is not allowed to modify or alter this document in any way and the manual shall be printed and used as it is in relation to the product. For the latest version of operating instructions, refer to the Jula website.
|
---|---
|
|
SAFETY INSTRUCTIONS
- This product can be used by children from 8 years of age and by persons with physical, sensorial or mental disabilities, or persons who lack experience or knowledge if they are supervised or receive instructions concerning the safe use of the product and understand the risks involved.
- Keep children under supervision to make sure they do not play with the product.
- Do not allow children to clean or maintain the product without supervision.
- Incorrect installation and/or connection of the product can result in a risk of personal or fatal injury. Incorrect installation and/ or connection of the product can result in a risk of material damage, including but not limited to explosion, fire, and/or water damage.
- Installation, electrical connection, connection to a water pipe, and commissioning should be carried out by authorized electricians and personnel with authorization to carry out installation and/or connection of products in this category, and in compliance with current legislation.
- It is not permitted to modify the product and/or electrical circuits. Modification refers to dismantling and/or bypassing elements included in the product on delivery, installation and/or connection of elements not included in the product on delivery, and replacement of elements included in the product on delivery with elements that have not been approved by the manufacturer.
SYMBOLS
| Read the instructions.
---|---
| Approved in accordance with the relevant directives.
| Recycle discarded products in accordance with local regulations.
TECHNICAL DATA
Voltage | 230 V 50 Hz |
---|---|
Connection | 1/2″ |
Working pressure | 8 bar |
Volume | 10 l |
Output | 1500 W |
Cord length | 1.1 m |
Energy class (A+ – F) | B |
Working temperature | 60°C |
Size | 37 x 41 x 24 cm |
Weight | 6.48 kg |
DESCRIPTION
Sealed hot water heater with accumulator tank, with heat insulation.
FUNCTION
- The product consists of a steel container (water tank) and a plastic casing, with thermal insulation in between, plus 2 pipes with G 1/2” thread for cold water inlet (marked with blue ring) and hot water outlet (marked with red ring). The water tank is made of steel with a glass ceramic coating that provides protection from corrosion.
- On the flange, there is an electric heater element and thermostat. Products with glass ceramic coatings are fitted with a magnesium sacrificial anode. The electric heating element heats the water in the tank and is controlled by the thermostat, which automatically maintains the set temperature. The thermostat has built-in overheating protection, which switches off the power supply to the element if the temperature of the water is too hot.
- A shut-off valve with a safety valve ensures that the product is not emptied if the supply of cold water is stopped. The valve protects the product from overpressure when the water expands during the heating, by relieving the pressure through the outlet. It is normal for water to drip from the safety valve outlet during operation. This must be taken into consideration when the product is installed.
NOTE:
The shut-off valve with a safety valve does not protect the product if the
pressure in the water pipe exceeds the specified permitted pressure for the
product.
INSTALLATION
- The product must only be installed in areas and properties with normal fire safety.
- If the product is installed in a bathroom it must be protected from spraying water from a shower or other source.
- The product is only intended to be used in enclosed and heated areas where the temperature does not fall below 4°C. The product is not intended for prolonged continuous use.
INSTALLATION
- To reduce the loss of heat from pipes it is recommended to place the product as near to the tap point as possible. The place for installation must be selected so that it cannot be exposed to spraying water from a shower or other source.
- The product must be installed with the outlet pipe and inlet pipe turned up towards the ceiling.
- The product can be placed upright on the floor or hanging from a wall.
- For wall installation, the product must be fastened firmly to the wall with two hooks (minimum diameter 4 mm).
FIG. 1-12
CONNECTION
- The product is intended to supply hot water to households with a piping system with a pressure of less than 6 bar.
- The shut-off valve with a safety valve must be fitted in the supply pipe as per the flow arrow on the valve, which shows the direction of the incoming flow. No other shut-off taps must be fitted between the shut-off valve with the safety valve and the product. Exception: If local regulations or standards require the use of another safety valve or safety mechanism (in agreement with EN 1487 or EN 1489), this must be acquired separately. For mechanisms that function according to EN 1487, the specified pressure must not exceed 7 bar. Other safety valves should be calibrated to a pressure that is 1 bar less than what is specified on the product type plate. In such cases, the supplied safety valve cannot be used.
- The shut-off valve with the safety valve must be cleaned and checked at regular intervals to ensure that the product is working properly and safely. The valve must not be clogged or blocked. Any scale must be removed.
- The product must only be installed in areas where the floor has an approved sealing layer and where it is possible to empty the pipes, otherwise, there is a risk of material damage in the event of a fault in the hot water system. Do not put nonwater-resistant material or items under the product. If the product is installed in an area without an approved sealing layer a collector trough that runs to a drain should be placed under the product.
- It is normal for water to drip from the safety valve outlet during operation. The safety valve should be open to the atmosphere. Take steps to collect and lead water away from any leakage, otherwise, there is a risk of water damage.
- The product must be emptied if there is a risk of the ambient temperature falling below 0°C. The power supply to the product must be disconnected before the product is
emptied of water.
Connection to water pipe
NOTE:
Collector trough sold separately.
- Inlet pipe.
- Safety valve (8 bar).
- Pressure relief valve (if the water pressure exceeds 6 bar).
- Shut-off valve.
- Funnel-shaped outlet to drain.
- Hose.
FIG. 15
Note the color markings (rings) on the pipes when connecting to the water pipe. BLUE for the water inlet/cold water. RED for water outlet/hot water. The shut-off valve with the safety valve supplied with the product must be installed. The shut-off valve with a safety valve must be installed in the supply pipe as per the flow arrow on the valve.
The product is filled with water by opening the tap in the supply pipe and the mixer’s hot water tap. The product is filled with water when the flow of water from the mixer tap is continuous. The mixer tap can then be closed. The power supply to the product must be disconnected before the product is emptied of water.
NOTE:
It is not permitted to use any other type of shut-off device between the shut-
off valve with the safety valve and the product.
NOTE:
The use of other shut-off valves with safety valves can cause the product to
malfunction. Any such devices must therefore be removed.
NOTE:
It is not permitted to install the shut-off valve with a safety valve on a
thread longer than 10 mm, because this can damage the valve and can result in
using the product resulting in a risk of personal injury and/or material
damage.
NOTE:
The safety valve and the pipe between the valve and the product must be
protected from freezing. When emptying with a hose the free end of the hose
should always be open to the atmosphere (not immersed in fluid). The hose must
also be protected from freezing.
Emptying of products for installation below tap point
- Disconnect the power supply to the product.
- Disconnect the water connections from the product.
- Find a suitable container. Unhang the product, turn it with the pipes to the floor, and let the water run out into the container. Wait until all the water has run out. A pressure relief valve must be fitted if the pressure in the water pipe is higher than the value given in section I above, otherwise, the product will not work properly. The manufacturer cannot accept liability for any damages resulting from improper use.
IMPORTANT:
Take suitable precautions to avoid water damage when emptying the product.
MAINS CONNECTION
- Check that the product is full of water before starting.
- Make sure to connect the product to earth when connecting to the mains.
- A damaged cord or plug must be replaced by an authorized service center or qualified person to ensure safe use.
- A hissing noise may be heard when the water is heating. This is normal. The noise can increase in time as a result of scale. Remove scale regularly to avoid high levels of noise.
Models with power cord and plug
- Models with a power cord and plug are connected to a power point. The product can be disconnected from the mains by unplugging the plug.
The wires in the connecting cable are connected as follows.
– Wire with brown insulation is connected to the live wire (L).
– Wire with blue insulation is connected to the neutral wire (N).
– Wire with yellow/green insulation is connected to the earth wire ( ).
FIG. 14
Models without connecting cable for permanent connection
- The product must be connected to a separate circuit. The circuit must have a 16 A fuse. Single wires (not stranded) must be used for the connection. The minimum cross-sectional area is 3 x 1.5 mm2 for an output of 2000 W.
- The circuit to which the product is connected must have a built-in all-pole switch that complies with the requirements for overvoltage category III.
- The plastic casing must be removed before the electrical connection of the product. The connection follows the marking of the terminals in the overheating protection.
– The live wire is connected to the terminal marked (L).
– The neutral wire is connected to the terminal marked (N).
– The earth wire is connected to the terminal marked.
The power cord can be connected to the control panel with a stress reliever. Replace the plastic casing correctly after connection.
FIG. 14
TR: Thermostat. TS: Overheating protection. IL:
Status light. R: Heater element.
NOTE:
The product must be connected to a correctly fused separate circuit. Only
connect the product to a correctly earthed power point.
USE
Before using the product for the first time check that it is correctly connected to the power supply and full of water. The product is started with switch included in the installation circuit, or for products with a power cord and plug by plugging the plug.
- Status light
- Adjusting lever
The status light (1) goes on when the product is in heating mode. The status
light (1) goes off when the water reaches the set temperature to indicate that
the product is not heating.
FIG. 13
TEMPERATURE SETTING
The required temperature can be set with the dial on the control panel.
FIG. 13
OVERHEATING PROTECTION
The product has overheating protection that switches off the power to the
product if the temperature of the water is too hot.
WARNING!
If the overheating protection trips it will not reset automatically and the
product will not work. Contact an authorized service center.
MAINTENANCE
Clean the product as necessary with a soft, damp cloth. Do not use abrasive
detergent or solvent on the product. Do not spray water or any other liquid on
the product. The magnesium sacrificial anode protects the inside of the water
tank from corrosion. The anode becomes consumed in time and must be replaced
at regular intervals.
The manufacturer recommends that qualified personnel check the anode at
regular intervals and replace it when necessary for best results and life
span. This check should be included in the regular preventive maintenance of
the product.
Contact an authorized service center for replacement anodes.
Scale forms in time during normal use on the surface of the heater element.
Such deposits reduce the transfer of heat between the heater element and the
water. A higher surface temperature on the heater element is required to heat
the water. The thermostat will switch on and off more often. The overheating
protection can trip. The manufacturer recommends preventive maintenance every
other year by an authorized service center to avoid such problems. Such
preventive maintenance should include cleaning and checking the sacrificial
anode (for products with glass ceramic coating). The sacrificial anode should
be replaced when necessary.
The manufacturer cannot accept liability for any damage resulting from failure to follow these instructions.
Product Fiche(in accordance with EU regulation no. 812/2013)
Trade mark: JULA
Model: Water heater 10l over
Load profile: XXS –
Energy efficiency class: B
Energy efficiency: 35 η wh [%] Annual electricity consumption AEC:
535 AEC, [kWh/annum] [кВт⋅⋅год/рік] Thermostat temperature settings: 60
T out of box [˚C] Sound power level: 15 dB
Specific precautions: Refer to the manual
Product Information (in accordance with EU regulation no. 814/2013)
Model: Water heater 10l over
Daily electricity consumption: 2,535 Qelec [kWh] [кВт·год] Load
profile: XXS
Sound power level: 15 dB
Storage volume: 10,0 V, [l] [л] Mixed water at 40 °C V40: [L] [л]
T max: 60 Tmax [˚C] Out-of-box mode: 60 Tout of the box [˚C] Water
heating energy efficiency: 34,5 ηwh [%]
All of the data that is included in the product information was determined by applying the specifications of the relevant European directives. Differences to product information listed elsewhere may result in different test conditions. Only the data that is contained in this product information is applicable and valid.
2022-08-22
WWW.JULA.COM
© JULA AB
JULA AB
BOX 363, 532 24 SKARA, SWEDEN
References
Read User Manual Online (PDF format)