Important Safety Instructions

Please read this owner’s guide carefully and save it for future reference.

This product is intended for installation by professional installers only! This document is intended to provide professional installers with basic installation and safety guidelines for this product in typical fixed- installation systems. Please read this document before attempting installation.

WARNING

  • All Bose products must be installed in accordance with local, state, federal and industry regulations. It is the installer’s responsibility to ensure installation of the loudspeakers and mounting system is performed in accordance with all applicable codes, including local building codes and regulations. Consult the local authority having jurisdiction before installing this product.
  • To reduce the risk of fire or electrical shock, do not expose the product to rain or moisture.
  • Do not expose this apparatus to dripping or splashing, and do not place objects filled with liquids such as vases, on or near the apparatus. Exposure to liquid may create a fire hazard.
  • Do not place any naked flame sources, such as lighted candles, on or near the apparatus.
  • This product is not intended for installation or use in indoor water facility areas (including, without limitation, indoor pools, indoor water parks, hot tub rooms, saunas, steam rooms and indoor skating rinks).

Symbol Contains small parts which may be a choking hazard. Not suitable for children under age 3.

CAUTION:

  • Do not make unauthorized alterations to the product; doing so may compromise safety, regulatory compliance, system performance, and may void the warranty.

The exclamation point within an equilateral triangle, as marked on the system, is intended to alert the user to the presence of important operating and maintenance instructions in this installation guide.

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with a dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources, such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.
  9. Only use attachments/accessories specified by the manufacturer.
  10. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

This product conforms to all applicable EU directive requirements. The complete Declaration of Conformity can be found at www.Bose.com/compliance

This product conforms to all applicable Electromagnetic Compatibility Regulations 2016 and all other applicable UK regulations. The complete declaration of conformity can be found at: www.Bose.com/compliance

Introduction

Product Features

Bose® ControlCenter zone controllers provide three options for remote volume control and input source selection:

Controller Function Compatible Products
CC-1 Volume control only FreeSpace® IZA 190-HZ1, IZA 250-LZ1, IZA 2120-LZ/HZ

FreeSpace ZA 2120-LZ/A – HZ/A FreeSpace DXA 2120
PowerShare PS602, PS404A, PS604A
Any ControlSpace® processor
CC-2| Volume control with A/B source selection switch| FreeSpace IZA 190-HZ, IZA 250-LZ, IZA 2120-LZ/HZ

FreeSpace DXA 2120

Any ControlSpace processor

CC-3| Volume control with A/B/C/D source selection switch| Any ControlSpace processor

Each zone controller is available in white and black, and in North America, Japan, and EU configurations. The North America zone controllers are sized for Decora® wall mounting, and include two 1/2 inch #6-32 screws. The Japan zone controllers fit Wide 21 wall plates with a face height of 1 mm above the thick wall plate cover; the controllers have approximately 3 mm face height when used with other types of wall plate covers. Two 8 mm M4 screws are included. Wall plate covers are not included with North America and Japan zone controllers. The EU zone controllers come as a finished wall plate of size 86 mm x 86 mm, with 60 to 60.3 mm screw spacing suitable for either vertical or horizontal mounting, and include two 18 mm M4 screws. All models include a sheet of pre-printed color-matched labels.

Connecting a Single Zone Controller

Connect a single zone controller to a FreeSpace or PowerShare amplifier using a CAT 5 cable with maximum length of 609 meters (2000 feet). Connect to a ControlSpace ESP using a CAT 5 cable with a maximum length of 152 meters (500 feet) for a shielded cable or 30 meters (100 feet) for an unshielded cable. The cable must be terminated on one end with an RJ-45 connection using TIA/EIA 568B pinout, and on the other end with an RJ-45 connector for PowerShare amplifiers, or the Euroblock connector appropriate for the FreeSpace amplifier or ControlSpace processor (2-pin, 4-pin, or 6-pin).

Operates with a fixed input (B). Amp front panel A/B switch is inactive.

Connecting Multiple Zone Controllers

Some amplifier models allow adjacent zone controllers to be ganged together directly. Each zone controller can be independently configured to control any output, or combination of outputs, for bi-amping.

Use a CAT 5 cable with RJ-45 connectors to connect zone controllers to each other, then create a single home run from the last zone controller in the chain back to the amplifier. The maximum total cable length (from the first zone controller to the amplifier) is 609 meters (2000 feet). Use standard CAT 5 cables and RJ-45 connectors as described in Connecting a Single Controller.

CV41 4-to-1 Converter

For PowerShare amplifier models, you can use the CV41 4-to-1 Converter to create a single home run back to an amplifier from multiple zone controllers distributed throughout an installation. Connect each zone controller to the CV41 converter using CAT 5 cables with RJ 45 connectors, then run a single CAT 5 cable from the CV41 4-to-1 Converter to the amplifier. You can connect up to two CC-1 zone controllers to a PS602 amplifier, and up to four CC-1 zone controllers to a PS404A or PS604A amplifier, or any ControlSpace processor.

CV41 4-to-1 Converter

CC-1 Installation Guide

CC-1 Zone Controller

The CC-1 zone controller provides volume control only. It is compatible with FreeSpace®
IZA 190-HZ, IZA 250-LZ, IZA 2120-LZ/HZ, ZA 2120-LZ/A – HZ/A; DXA 2120 amplifiers; PowerShare PS602, PS404A, and PS604A amplifiers; and any ControlSpace® processor.

CC-1 Zone Controller – North America

CC-1 Zone Controller - North America

CC-1 Zone Controller – Japan

CC-1 Zone Controller - Japan

CC-1 Zone Controller – EU

CC-1 Zone Controller - EU

Pin-to-Remote Connections

Connections from the RJ-45 (TIA/EIA 568B wiring) connector on the CC-1 zone controller to the REMOTE connector on the FreeSpace® amplifier or CONTROL INPUTS connector on the ControlSpace® processor. Use GPI mode A- in CSD. PowerShare requires a separate wire in the CAT 5 cable for COM, PWR, and each VOL_# connection.

Pin| Color| FreeSpace IZA/ZA| FreeSpace DXA 2120| ControlSpace| PowerShare
---|---|---|---|---|---
8| Brown| | | | COM
7| White/Brown| | | |
6| Green| | | VOL #4| VOL_4
5| White/Blue| | | VOL #3| VOL_3
4| Blue| VOL #2| | VOL #2| VOL_2
3| White/Green| VOL #1| PWR| VOL #1| VOL_1
2| Orange| PWR #2| VOL_2| |
1| White/Orange| PWR #1| VOL_1| COM| PWR
| CSD GPI Mode: A-|

Connecting the CC-1 Zone Controller

Connect one CC-1 zone controller to FreeSpace® amplifier models IZA 190-HZ1 , IZA 250-LZ1 , IZA 2120-LZ/HZ, ZA 2120-LZ/A – HZ/A, or DXA 2120, or PowerShare amplifier models PS602, PS404A, or PS604A, or any ControlSpace® processor. Use GPI mode A- CSD. If one CC-1 is to be used in zone 2 of the DXA 2120, then wire into VOL_2. DIP switch settings are the same.

Connecting the CC-1 Zone Controller

Pin-to-Remote Connection Diagrams

Pin-to-Remote Connection Diagrams

If one CC-1 is to be used in zone 2, then wire into VOL_2. DIP switch settings are the same.

Pin-to-Remote Connection Diagrams

Configure the CC-1 zone controller using the following DIP switch settings:

| 1| 2| 3| 4| 5| 6| 7| 8|
---|---|---|---|---|---|---|---|---|---
FreeSpace IZA/ZA| 0| 0| 1| 0| 1| 0| 0| 0
FreeSpace DXA 2120| 0| 0| 1| 0| 1| 0| 0| 0
**PowerShare*| 0| 0| 1| 0| | | |
ControlSpace**| 0| 0| 1| 0| | | | **| CSD GPI Mode: A-

For the PowerShare PS602, PS404A, and PS604A amplifiers, the CC-1 controls any outputs with corresponding DIP switches in the ON position:

DIP 5 – OUTPUT 1
DIP 6 – OUTPUT 2
DIP 7 – OUTPUT 3 (PS404A and PS604A only)
DIP 8 – OUTPUT 4 (PS404A and PS604A only)

** For the DSPs, the DIP switch configuration determines the CC-1 ID:

DIP 5 – ID 1
DIP 6 – ID 2
DIP 7 – ID 3
DIP 8 – ID 4

FreeSpace IZA/ZA/DXA 2120, PowerShare Amplifiers, and ControlSpace Processors

CC-1 Zone Controller #1

Connect two ganged CC-1 zone controllers to FreeSpace® amplifier models IZA 2120-HZ,
ZA 2120-HZ/A or DXA 2120; or PowerShare amplifier models PS602, PS404A, or PS604A; or any ControlSpace processor

CC-1 Installation

Pin-to-Remote Connection Diagrams

Pin-to-Remote Connection Diagrams

Configure the CC-1 zone controllers using the following DIP switch settings:

| 1| 2| 3| 4| 5| 6| 7| 8|
---|---|---|---|---|---|---|---|---|---

FreeSpace IZA/ZA

| Controller #1| 0| 0| 1| 0| 1| 0| 0| 0
Controller #2| 0| 0| 0| 1| 0| 1| 0| 0
FreeSpace DXA 2120| Controller #1| 0| 0| 1| 0| 1| 0| 0| 0
Controller #2| 0| 0| 0| 1| 1| 0| 0| 0
**PowerShare*| Controller #1| 0| 0| 1| 0| | | |
Controller #2| 0| 0| 1| 0| | | |
ControlSpace**| Controller #1| 0| 0| 1| 0| | | | | CSD GPI Mode: A-
Controller #2| 0| 0| 1| 0| | | | **

  • For the PowerShare PS602, PS404A, and PS604A amplifiers, the CC-1 controls any outputs with corresponding DIP switches in the ON position:

DIP 5 – OUTPUT 1
DIP 6 – OUTPUT 2
DIP 7 – OUTPUT 3 (PS404A AND PS604A only)
DIP 8 – OUTPUT 4 (PS404A AND PS604A only)

** For the DSPs, the DIP switch configuration determines the CC-1 ID:

DIP 5 – ID 1
DIP 6 – ID 2
DIP 7 – ID 3
DIP 8 – ID 4

  • FreeSpace IZA/ZA Amplifiers

  • FreeSpace DXA 2120 Amplifier

  • PowerShare Amplifiers/ ControlSpace DSP (Any)

Connect up to four ganged CC-1 zone controllers to the PowerShare amplifier models PS404A and PS604A, or any ControlSpace processor.

CC-1 Installation

Configure the CC-1 zone controllers using the following DIP switch settings:

| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---
Controller #1| 0| 0| 1| 0| 1| 0| 0| 0
Controller #2| 0| 0| 1| 0| 0| 1| 0| 0
Controller #3| 0| 0| 1| 0| 0| 0| 1| 0
Controller #4| 0| 0| 1| 0| 0| 0| 0| 1

CC-1 Installation

Connect multiple CC-1 zone controllers to PowerShare amplifier models PS602, PS404A, or PS604A using the CV41 4-to-1 converter. Connect up to two CC-1 zone controllers to the PS602 amplifier or up to four CC-1 zone controllers to the PS404A and PS604A amplifiers, or any ControlSpace processor.

CC-1 Installation

Configure the CC-1 zone controllers using the following DIP switch settings:

| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---
Controller #1| 0| 0| 1| 0| 1| 0| 0| 0
Controller #2| 0| 0| 1| 0| 0| 1| 0| 0

CC-1 Installation

Connect up to four CC-1 zone controllers to the PowerShare PS404A and PS604A amplifier, or any ControlSpace processor, using the CV41 4-to-1 converter.

CC-1 Installation

Configure the CC-1 zone controllers using the following DIP switch settings:

| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---
Controller #1| 0| 0| 1| 0| 1| 0| 0| 0
Controller #2| 0| 0| 1| 0| 0| 1| 0| 0
Controller #3| 0| 0| 1| 0| 0| 0| 1| 0
Controller #4| 0| 0| 1| 0| 0| 0| 0| 1

CC-1 Installation

CC-2 Installation

CC-2 Zone Controller

The CC-2 zone controller provides volume control and A/B source selection. It is compatible
with FreeSpace® amplifier models IZA 190-HZ, IZA 250-LZ, IZA 2120-LZ/HZ, DXA 2120, and any ControlSpace® processor

CC-2 Zone Controller – North America

CC-2 Zone Controller - North America

CC-2 Zone Controller – Japan

CC-2 Zone Controller - Japan

CC-2 Zone Controller – EU

CC-2 Zone Controller - EU

Pin-to-Remote Connections

Connections from the RJ-45 (TIA/EIA 568B wiring) connector on the CC-2 zone controller to REMOTE connector on the FreeSpace® amplifier or to CONTROL INPUTS connector on the ControlSpace® processor. Use GPI mode A- in CSD.

Pin| Color| FreeSpace IZA| FreeSpace DXA 2120| ControlSpace ESP
---|---|---|---|---
8| Brown| | |
7| White/Brown| A/B Select #2| A/B_2| A/B Select #2
6| Green| A/B Select #1| A/B_1| A/B Select #1
5| White/Blue| | |
4| Blue| VOL #2| | COM #2
3| White/Green| VOL #1| PWR| COM #1
2| Orange| PWR #2| VOL_2| VOL #2
1| White/Orange| PWR #1| VOL_1| VOL #1
| CSD GPI Mode: A-

Connecting the CC-2 Zone Controller

Connect one CC-2 zone controller to FreeSpace® amplifier models IZA 250-LZ, IZA 190 HZ, IZA 2120-LZ/HZ, DXA 2120, and any ControlSpace® processor. Use GPI mode A- in CSD.

Connecting the CC-2 Zone Controller

Pin-to-Remote Connection Diagrams

Pin-to-Remote Connection Diagrams

Configure one CC-2 zone controller using the following DIP switch settings:

| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---
Controller| 1| 0| 1| 0| 1| 0| 0| 0

Connect two ganged CC-2 zone controllers to FreeSpace® amplifier model IZA 2120-HZ or DXA 2120, or any ControlSpace processor.

CC-2 Installation

Pin-to-Remote Connection Diagrams

Pin-to-Remote Connection Diagrams

| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---
Controller #1| 1| 0| 1| 0| 1| 0| 0| 0
IZA/ZA/DSP #2| 0| 1| 0| 1| 0| 1| 0| 0
DXA 2120 #2| 0| 1| 0| 1| 1| 0| 0| 0

Pin-to-Remote Connection Diagrams

CC-3 Installation

CC-3 Zone Controller

The CC-3 zone controller provides volume control and A/B/C/D source selection. It is compatible with any ControlSpace® processor.

CC-3 Zone Controller – North America

CC-3 Zone Controller - North America

CC-3 Zone Controller – Japan

CC-3 Zone Controller - Japan

CC-3 Zone Controller – EU

CC-3 Zone Controller - EU

Pin-to-Remote Connections

Connections from the RJ-45 (TIA/EIA 568B wiring) connector on the CC-3 zone controller to the CONTROL INPUTS connector on the ESP. Use GPI mode A+ in CSD.

Pin Color ControlSpace
8 Brown COM
7 White/Brown A
6 Green B
5 White/Blue C
4 Blue D
3 White/Green VOL
2 Orange
1 White/Orange
CSD GPI Mode: A+

Connecting the CC-3 Zone Controller

Connect one CC-3 zone controller to any ControlSpace® processor. Use GPI mode A+ in CSD.

Connecting the CC-3 Zone Controller 

Pin-to-Remote Connection Diagrams

Pin-to-Remote Connection Diagrams

Limited Warranty

Your product is covered by a limited warranty, Visit pro.Bose.com for warranty details.

The warranty information provided with this product does not apply in Australian and New Zealand. See our website at www.bose.com/au/warranty or www.bose.com/nz/warranty for details of the Australian and New Zealand warranty.

Decora® is a registered trademark of Leviton Manufacturing Co., Inc.

Importer Information

China Importer: Bose Electronics (Shanghai) Company Limited, Level 6, Tower D, No. 2337 Gudai Rd. Minhang District, Shanghai 201100
UK Importer: Bose Limited Bose House, Quayside Chatham Maritime, Chatham, Kent, ME4 4QZ, United Kingdom
EU Importer: Bose Products B.V., Gorslaan 60, 1441 RG Purmerend, The Netherlands Mexico Importer: Bose de México, S. de R.L. de C.V. , Paseo de las Palmas 405-204, Lomas de Chapultepec, 11000 México, D.F. For importer & service information: +5255 (5202) 3545
Taiwan Importer: Bose Taiwan Branch, 9F-A1, No. 10, Section 3, Minsheng East Road, Taipei City 104, Taiwan. Phone Number: +886-2-2514 7676

Contact Information

Visit us on the web atpro.Bose.com.

Americas
(USA, Canada, Mexico, Central America, South America)
Bose Corporation
The Mountain
Framingham, MA 01701 USA
Corporate Center: 508-879-7330
Americas Professional Systems,
Technical Support: 800-994-2673

Australia
Bose Pty Limited
Unit 3/2 Holker Street
Newington NSW Australia
TEL 61 2 8737 9999

Belgium
Bose N.V. / S.A
Limesweg 2, 03700
Tongeren, Belgium
TEL (32) 012-390800

China
Bose Electronics (Shanghai) Co Ltd
36F, West Gate Tower
1038 West Nanjing Road
Shanghai, P.R.C. 200041 China
TEL 86 21 6271 3800

France
Bose S.A.S
12 rue de Temara
78100 St. Germain en Laye, France
TEL 01-30-61-63-63

Hong Kong
Bose Limited
Suites 2101-2105, Tower One, Times Square
1 Matheson Street, Causeway Bay, Hong Kong
TEL 852 2123 9000

India
Bose Corporation India Private Limited
Salcon Aurum, 3rd Floor
Plot No. 4, Jasola District Centre
New Delhi – 110025, India
TEL 91 11 43080200

Italy
Bose SpA
Centro Leoni A – Via G. Spadolini
5 20122 Milano, Italy
TEL 39-02-36704500

Japan
Bose Kabushiki Kaisha
Shibuya YT Building
28-3 Maruyama-sho
Shibuya-Ku, Tokyo, 150, Japan
TEL 81-3-5489-0955
www.bose.co.jp

The Netherlands
Bose BV
Nijverheidstraat 8 1135 GE
Edam, Nederland
TEL 31 (0)299-390139

United Kingdom
Bose House
Quayside Chatham Maritime
Chatham, Kent ME4 4QZ, United Kingdom
TEL 44 (0)3330-142545

Germany
Bose GmbH
Max-Planck Strasse 36D 61381
Friedrichsdorf, Deutschland
TEL 06172-7104-0

See website for other countries

©2022 Bose Corporation, All rights reserved.
Framingham, MA 01701-9168 USA
PRO.BOSE.COM
All trademarks are the property of their respective owners
AM771705 Rev. 02
April 2022

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals