Specifications
- 12VDC or 24VDC operation.
- Current draw: 95mA.
- 30A/28VDC, 120VAC or 277VAC SPDT contacts.
- UL Recognized relay.
Board Dimensions (W x L x H):
2” x 2.75” x 0.75” (50.8mm x 69.9mm x 19.1mm)
Operation
-
Mount the RB30 in desired location/enclosure.
-
Set switch to select 12VDC or 24VDC operation.
ON for 12VDC, OFF for 24VDC. -
Upon proper voltage application (12 or 24) to terminals marked [POS (+) and NEG (–)] relay will actuate and red LED will be lit.
-
Use output contacts to make and break load circuits.