Forney Industries 45 P PRO Plasma Cutter User Guide
- June 10, 2024
- Forney Industries
Table of Contents
Forney Industries 45 P PRO Plasma Cutter User Guide
-
Read user manual
-
Connect to input air
Output air pressure is pre-set at the factory
* Clean air
* No oil
* No moisture
* 100-130 PSI
* 6.6 CFM recommended
-
Connect to input power
- Generator OK with continuous output > 5,000 W (120V) or 10,000 W (240V)
- Extension cord: #12 AWG (120V) or #8 AWG (240V) or larger. 25’ (8m) or shorter extension cords recommended
-
Drag tip on workpiece
NOTE: Correct consumable assembly
OPERATING TIPS
-
Travel speed
Too fast.Watch spark trail angle. -
Cutting capability
Will cut clean up to
120V: 1/4” (6,4mm)
240V: 7/8” (22mm)
-
Replace worn consumables
TROUBLESHOOTING GUIDE
Fault Code F01 Duty cycle exceeded
Allow machine to cool. See manual.
Fault Code F02 Input power outside of acceptable range
Verify power source is 240 (or 120) VAC +/- 10%
Fault Code F03 Consumables not in place properly
Check consumable assembly. Tighten cup. See manual.
Fault Code F04 Input air pressure outside of acceptable range
Ensure air input meets pressure and flow requirements. See manual.
FIND MORE INFORMATION ATFORNEYIND.COM
QUESTIONS OR TROUBLE?
Contact Forney Industries at
1-800-521-6038
customerservice@forneyind.com
forneyind.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>