Forney Industries 45 P PRO Plasma Cutter User Guide

June 10, 2024
Forney Industries

Forney Industries 45 P PRO Plasma Cutter User Guide
Forney Industries 45 P PRO Plasma Cutter

  1. Read user manual

  2. Connect to input air

Output air pressure is pre-set at the factory

  * Clean air
  * No oil
  * No moisture
  * 100-130 PSI
  * 6.6 CFM recommended
  1. Connect to input power

    • Generator OK with continuous output > 5,000 W (120V) or 10,000 W (240V)
    • Extension cord: #12 AWG (120V) or #8 AWG (240V) or larger. 25’ (8m) or shorter extension cords recommended
  2. Drag tip on workpiece
    INSTRUCTION

NOTE: Correct consumable assembly
INSTRUCTION

OPERATING TIPS

  • Travel speed
    OPERATING TIPS
    Too fast.Watch spark trail angle.

  • Cutting capability
    Cutting capability
    Will cut clean up to
    120V: 1/4” (6,4mm)
    240V: 7/8” (22mm)

  • Replace worn consumables
    Replace worn consumables

TROUBLESHOOTING GUIDE

Fault Code F01 Duty cycle exceeded

Allow machine to cool. See manual.

Fault Code F02 Input power outside of acceptable range

Verify power source is 240 (or 120) VAC +/- 10%

Fault Code F03 Consumables not in place properly

Check consumable assembly. Tighten cup. See manual.

Fault Code F04 Input air pressure outside of acceptable range

Ensure air input meets pressure and flow requirements. See manual.

FIND MORE INFORMATION ATFORNEYIND.COM 

QUESTIONS OR TROUBLE?
Contact Forney Industries at 1-800-521-6038 customerservice@forneyind.com forneyind.com