Scolmore Deco Fused Connection Units User Manual

June 10, 2024
Scolmore

Scolmore Deco Fused Connection Units User Manual
Scolmore Deco Fused Connection Units

After making the connections, screw the fused connection unit gently to the back box ensuring no wires become trapped. Screw the accessory fully home making sure, when done, the plate is not distorted.

Mains Wiring:
‘L’ – Live Coloured Brown or Red
– CPC Coloured Green/Yellow
‘N’ – Neutral Coloured Blue or Black
Mains Wiring

Decorative accessory plates are not suitable to be mounted onto wet / damp plaster or paint, as this may cause the accessory to tarnish. This range is not suitable for outdoor installation or in areas of high humidity. For cleaning / polishing of products, use only a soft, dry, clean cloth.

Technical Information

Voltage 230V~ 50Hz
Current Rating 13A
Terminal Size 5mm ø
Torque Value Terminal Screw: 2.0Nm
Cable Size 3 x 2.5mm2 or 2 x 4.0mm2
Back Box Depth (Min) 25mm (Deco, Deco+, Mode, Polar, Part M, Curva) 35mm (Define, Definity)
Operational Temperature -50 to +450 C
Standards The Low Voltage Directive 2014/35/EC Statutory Instruments 2014/35 BS 1363-4

Safety Information

Please read the following information carefully before commencing installation. Before commencing any electrical work, to prevent the possibility of receiving an electric shock, ensure the mains isolator on the consumer unit is in the ‘OFF’ position and safely isolated in accordance with Best Practice Guide 3. If in doubt consult a qualified electrician. The accessory plate must be installed in accordance with the latest IET Wiring Regulations, BS7671. If this product is being fitted as a replacement part to an existing installation account must be taken to the version of the wiring regulations it was installed to.

Installation Information

If replacing an existing accessory, check the layout of the existing terminals. When removing the cables from the terminals, note the cable connections in the terminal to ensure correct wiring of the new accessory. The mounting box must be of the correct size for the product, metal or plastic. If the back box has four lugs, then the top and bottom lugs will need to be bent back or removed. Please see Technical Information overleaf for minimum back box depth, range dependant. The cable must be routed through the most suitable entry point of the mounting box, taking note that a suitable protective grommet is recommended should a metal back box be used. Cables should be prepared to the appropriate lengths (as stated within these instructions) so that the conductor reaches into the terminal, and the circuit protective conductor is the longest. The terminals should be tightened to their appropriate torque value (2.0NM). Do not over tighten.

1 Gang Fused Connection Unit – Unswitched

Connection

Replacing the BS 1362 Fuse
Using a flat bladed screwdriver, slot into the groove of the fuse carrier. Fig. 1. Carefully leaver the screwdriver towards the wall. Fig. 2.

Replacing

1 Gang Fused Connection Unit Switched & Flex Outlet
Connection

Replacing the BS 1362 Fuse
Pull the fuse drawer towards you Fig. 3., Then push the fuse out, and replace with new fuse. Fig. 2. Push carrier drawer until flush with the faceplate

Replacing

References

Read User Manual Online (PDF format)