INTRODUCTION

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the InSinkErator® Water Filtration System. Retain these instructions for future reference.

  • F-3000S reduces PFOA/PFOS, pharmaceuticals, VOCs, cysts, lead, mercury, asbestos, benzene, atrazine, 2,4-D, lindane, TTHMs, p-Dichlorobenzene, class 1 particulates, and chlorine taste & odor

Warning
Warning indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury

Caution
Caution, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury

NOTICE
Notice is used to address practices not related to personal injury

*Claims valid and certified by IAPMO R&T when used in HWT300-F3000S System

COMPONENTS IN THIS PACKAGE

COMPONENTS IN THIS PACKAGE

A) Filter Head and Bracket
B) F-3000 Filter Cartridge
C) Two Polyethylene Tubes
D) “Y” Quick-Connector & Plug
E) Ferrule
F) Tube Insert
G) Brass Nut

OVERVIEW OF A COMPLETED SETUP

OVERVIEW OF A COMPLETED SETUP

Warning
To reduce the risk associated with choking: Do not allow children under 3 years of age to have access to small parts during the installation of this product.

Warning
To reduce the risk associated with ingestion of contaminants, do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before the system.

Warning
To reduce the risk associated with hazardous voltage do not install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the system bracket.

NOTICE
To reduce the risk associated with property damage due to water leakage or flooding, and to ensure optimal filter performance:

  • Replace filter cartridge every 6 months, or sooner if water flow rate slows.
  • Failure to replace the disposable filter cartridge at recommended intervals may lead to reduced filter performance and cracks in the filter housing, causing water leakage or flooding.
  • For systems using two handle HC model faucets, operate only one handle at a time.

Turn off water supply before starting.
Installation must comply with all state and local laws and regulations

INSTALLING FILTRATION SYSTEM

Warning
Personal Injury: Do not locate filter above an outlet or other electrical device. Install head and bracket so that connections require no stretching, kinking or pinching of tubing.

Screws provided are for use in wood studs or cabinets only. Use wall anchors (not supplied) for installation into drywall.
INSTALLING FILTRATION SYSTEM

  • Separate cartridge from filter head. Mark hole locations for filter head and bracket in a spot that allows for filter replacement.
  • Drill 1/8″ starter holes and attach bracket to wall with wood screws, turning until snug.
  • Insert cartridge into filter head. Top surface of cartridge will become flush with bottom of filter head when fully engaged

NOTICE
Property Damage: Tube runs need to form to the cabinet’s contours to allow storage space with no sharp bends. Tubes need clean, perpendicular, burr-free cuts to ensure a true fit.

  • Determine length of tubing required, then cut to length making sure the cut is perpendicular and burr-free.
  • Insert a 1/4″ tube into inlet side of filter head until it stops. Press in again to ensure a secure fit.
  • Insert the other 1/4″ tube into outlet side of filter head until it stops. Press in again to ensure a secure fit.
    INSTALLING FILTRATION SYSTEM

NOTICE
Property Damage: Do not extend the lines farther than the 16″ provided. Ensure tube(s) and “Y” connnector are securely fit

  • Insert the copper tubes(s) from the dispenser into “Y” quick-connector using the plug for hot-only models.
  • Connect the 1/4″ tube from the right outlet on the filter head into the quickconnect fitting until it stops. Press in again to ensure a secure fit.

To remove tube(s) or plug from quick-connector, depress the release ring and gently pull away
INSTALLING FILTRATION SYSTEM

It is normal for approximately 2 oz. of water to discharge when filter is removed.
INSTALLING FILTRATION SYSTEM

  • Connect remaining 1/4″ tube to incoming water supply line.

FINAL WATER CONNECTION

FINAL WATER CONNECTION

NOTICE
Property Damage: Join remaining tube to cold water supply only

  • Install a T-fitting (not included) onto the cold water supply line.
  • Install dedicated water control valve with 1/4″ compression fitting.
  • At the end of the 1/4″ tube from the filter or quick-connector, slide the supplied brass nut and ferrule over the tube and then push in the brass tube insert.
  • Insert the 1/4″ tube into the 1/4″ compression fitting and tighten.

TURN ON WATER & CONNECT POWER

TURN ON WATER & CONNECT POWER

Warning
Scalding Hazard: The faucet dispenses near-boiling (212ºF) water which can instantly cause scalds or burns. Use care when operating this appliance.

  • Turn on the water supply.
  • Depress the dispenser’s HOT handle and hold it until water flows from the spout (approximately 1 to 2 minutes).
  • Flush 3 gallons (11.4 L) through filter before first use (approximately 4 minutes).
  • Check all connections to ensure they are tight and that there are no leaks.

REPLACE FILTER EVERY 6 MONTHS

  • Add the next replacement date to your calendar (6 months from today) and write it on the enclosed sticker and attach filter label sticker to cabinet door or another convenient location for reference.
  • For your convenience and savings, scan this QR code to sign up for our filter subscription or filter reminder service.
    Qr code

Refer to the Performance Data Sheet online for InSinkErator Filter System Model F-3000S. Contact an authorized InSinkErator service agent for repairs or replacement components. Replacement filter F-3000 can be ordered by calling 800-558-5700, visiting shop.insinkerator.com, or by contacting an authorized InSinkErator reseller.

Pressure: 30-80 psi (207-550 kPA)
Temperature: 33˚F – 100˚F
F-3000S Flowrate: 0.75 gpm
Capacity: 500 gallons

Symbols
The F-3000 filter is certified by IAPMO R&T against NSF/ANSI standards 42, 53, 401 and CSA B483.1 for the reduction of claims specified in the performance data sheet when used in system HWT300-F3000S. HWT300-F3000S is also certified against NSF/ANSI 58 for material safety requirement and NSF/ANSI 372 for Lead Free.

IMPORTANT SAFETY INFORMATION

NOTICE
To reduce the risk associated with property damage due to water leakage or flooding:

  • Read and follow Use Instructions before installation and use of this system.
  • Installation and use MUST comply with all state and local plumbing codes.
  • Protect from freezing, remove filter cartridge when ambient temperatures are expected to drop below 40°F (4.4°C).
  • Contact a plumbing professional if you are uncertain how to check for these conditions.
    • If your water pressure exceeds 80 psi (550 kPa), you must install a pressure limiting valve.
    • Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester.
    • Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed.
  • Do not use a torch or other high temperature sources near system, cartridges, plastic fittings or plastic plumbing.
  • Do not install systems in areas where ambient temperatures may go above 100°F (37.8°C).
  • Do not install on hot water supply lines. The maximum operating water temperature of this system is 100°F (37.8°C).
  • Do not install in direct sunlight or outdoors.
  • Mount system in such a position as to prevent it from being struck by other items used in the area of installation.
  • Ensure that the location and fasteners will support the weight of the system when installed and full of water.
  • Ensure all tubing and fittings are secure and free of leaks.
  • Do not install unit if collet is missing. Contact 800-558-5700 if collets are missing from any fittings.
  • Do not install using rigid piping. System intended for use with plastic water lines (such as PEX tubing, PE tubing, PP tubing).

INSINKERATOR IN-HOME LIMITED WARRANTY

This limited warranty is provided by InSinkErator LLC (“InSinkErator” or “Manufacturer” or “we” or “our” or “us”) to the original consumer owner of the InSinkErator product with which this limited warranty is provided (the “InSinkErator Product”), and any subsequent owner of the residence in which the Product was originally installed (“Customer” or “you” or “your”).
InSinkErator warrants to Customer that your InSinkErator Product will be free from defects in materials and workmanship, subject to the exclusions described below, for a period of 1 year (the “Warranty Period”), commencing on the later of: (a) the date your InSinkErator Product is originally installed, (b) the date of purchase, or (c) the date of manufacture as identified by your InSinkErator Product serial number. You will be required to show written documentation supporting (a) or (b). If you are unable to provide documentation supporting either (a) or (b), the Warranty Period commencement date will be determined by Manufacturer, in its sole and absolute discretion, based upon your InSinkErator Product serial number.

Permitted Uses
You may use your InSinkErator Product hot or cold water tank and filter system in combination with any genuine InSinkErator Product dispenser and component parts and/or Authorized OEM Products. “Authorized OEM Products” mean those hot, cold or hot/cold water dispensers and component parts that have been manufactured by an authorized InSinkErator original equipment manufacturer (“Authorized OEM”) and which have documentation expressly stating that such Authorized OEM Products are compatible with the InSinkErator Product(s). Authorized OEMs may change from time to time. A list of Authorized OEMs is available to you upon request or at: www.insinkerator.com/oem. Use of your InSinkErator Product in combination with any products other than Authorized OEM Products will void this warranty.

What is Covered
This limited warranty covers defects in materials or workmanship, subject to the exclusions below, in InSinkErator Products used by a consumer Customer for residential use only, and includes all replacement parts and labor costs. YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE INSINKERATOR PRODUCT, PROVIDED, THAT IF WE DETERMINE IN OUR SOLE DISCRETION THAT NEITHER REMEDY IS PRACTICABLE, WE MAY PROVIDE YOU WITH A REFUND OF YOUR PURCHASE PRICE OR  A CREDIT TOWARDS ANOTHER INSINKERATOR PRODUCT

What is not Covered
This limited warranty does not extend to and expressly excludes:

  • Losses or damages or the inability to operate your InSinkErator Product resulting from conditions beyond the Manufacturer’s control including, without limitation, accident, alteration, misuse, abuse, neglect, negligence (other than Manufacturer’s), failure to install, maintain, assemble, or mount the InSinkErator Product in accordance with Manufacturer’s instructions or local electrical and plumbing codes.
  • Wear and tear expected to occur during the normal course of use, including without limitation, cosmetic rust, scratches, dents or comparable and reasonably expected losses or damages.
  • Losses or damages caused by any product or component part used with the InSinkErator Products, including both Authorized OEM Products and other products and components.

In addition to the above exclusions, this limited warranty does not apply to InSinkErator Products installed in a commercial or industrial application.

No Other Express Warranty Applies
This limited warranty is the sole and exclusive warranty provided to the Customer identified above. No other express warranty, written or verbal, applies. No employee, agent, dealer, or other person is authorized to alter this limited warranty or make any other warranty on behalf of Manufacturer. The terms of this limited warranty shall not be modified by the Manufacturer, the original owner, or their respective successors or assigns.

What we will do to Correct Problems
If your InSinkErator Product does not operate in accordance with the documentation provided to you, or you have questions concerning your InSinkErator Product or how to determine when service is needed, please call the toll free InSinkErator AnswerLine at 1 800-558-5700, or visit our website at www.insinkerator.com. You may also notify us at: InSinkErator Service Center, 4700 21st Street, Racine, Wisconsin 53406 USA.

The following information must be provided as part of your warranty claim: your name, address, phone number, your InSinkErator Product model and serial number, and if necessary, upon request, written confirmation of either: (a) the date shown on your installation receipt, or (b) the date shown on your purchase receipt

Manufacturer or its authorized service representative will determine, in its sole and absolute discretion, if your InSinkErator Product is covered under this limited warranty. You will be given the contact information for your closest authorized InSinkErator Service Center. Please contact your InSinkErator Service Center directly to receive in home warranty repair or replacement service. Only an authorized InSinkErator service representative may provide warranty service. InSinkErator is not responsible for warranty claims arising from work performed on your InSinkErator Product by anyone other than an  authorized InSinkErator service representative.

If a covered claim is made during the Warranty Period, Manufacturer will, through its  authorized service representative, either repair or replace your InSinkErator Product. Cost of replacement parts or a new InSinkErator Product, and cost of labor for repair or installation of the replacement InSinkErator Product are provided at no cost to you. Repair or replacement shall be determined by Manufacturer or its authorized service representative in their sole discretion. All repair and replacement services will be provided to you at your home.

If Manufacturer determines that your InSinkErator Product must be replaced rather than repaired, the limited warranty on the replacement InSinkErator Product will be limited to the unexpired term remaining in the original Warranty Period.

This InSinkErator Product is covered by Manufacturer’s limited warranty. This limited warranty is void if you attempt to repair the InSinkErator Product. For service information, please visit www.insinkerator.com or call, toll free, 1-800-558-5700

Limitation of Liability
TO THE EXTENT PERMITTED BY LAW, IN NO EVENT SHALL MANUFACTURER OR ITS AUTHORIZED SERVICE REPRESENTATIVES BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING ANY ECONOMIC LOSS, WHETHER RESULTING FROM NONPERFORMANCE, USE, MISUSE OR INABILITY TO USE THE INSINKERATOR PRODUCT OR THE MANUFACTURER’S OR ITS AUTHORIZED SERVICE REPRESENTATIVE’S NEGLIGENCE. MANUFACTURER SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT, REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY, OTHER SORT OR OTHERWISE), SHALL MANUFACTURER’S LIABILITY TO YOU EXCEED THE PRICE PAID BY THE ORIGINAL OWNER FOR THE INSINKERATOR PRODUCT.

The term “consequential damages” shall include, but not be limited to, loss of anticipated profits, business interruption, loss of use or revenue, cost of capital or loss or damage to property or equipment. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state.

InSinkErator® may make improvements and/or changes in the specifications at any time, in its sole discretion, without notice or obligation and further reserves the right to change or discontinue models.

InSinkErator may make improvements and/or changes in the specifications at any time, in its sole discretion, without notice or obligation and further reserves the right to change or discontinue models.
®/TM © 2022 InSinkErator. All rights reserved.

Scan to sign up for subscribe and save or for filter replacement reminders.
Qr code

1-800-558-5700
262-233-2231

1250 International Drive Mount Pleasant,
WI 53177 1.800.558.5700
www.insinkerator.com