LEPU LFR60 Infrared Forehead Thermometer Instruction Manual
Foreword
Please read the instruction manual carefully before using the infrared forehead thermometer for the first time, because the correct temperature measurement can be made only when the infrared thermometer is used in a correct way. The instruction manual presents the specific steps for measuring forehead temperature with the thermometer, and effective tips on how to reliably measure the forehead temperature. Please keep the instruction manual properly.
Safety Instructions
Warning
- Keep the device out of reach of infants, children or pets, since inhalation or swallowing of small parts (e.g. batteries) can be dangerous or even fatal.
- Do not use the thermometer for any other purpose than intended.
- The thermometer is not waterproof, do not immerse it in water or other liquids of any kind.
- Do not keep the thermometer in extreme environment.
- Please keep a distance of 0-5cm from the forehead center, better in between the eye and brow when measuring.
- If the infrared thermometer is kept in a place where the temperature is lower or higher than that of the place where it is used, please put it in the room where it is to be used 30 minutes in advance.
- The device contains no user serviceable parts.
- The user must check if the equipment can work safely, and see that it is in proper working condition before using.
- No modification of this equipment is allowed.
- The thermometer measurement does not substitute for diagnosis by physicians ,If you feel unwell and the temperature has been measured above 37.5°C several times, consult your doctor.
- This infrared forehead thermometer does not apply to premature or underage infants.
- Do not allow children to take their own temperature without supervision
- Do not remove the thermometer until you hear the beep.
- Please try to take the temperature in the same place, otherwise you may get different results.
- Do not hold the sensor when measuring to avoid the error code due to temperature instability.
- The device is not suitable for use in the presence of flammable anesthetic mixtures with air ,oxygen or nitrous oxide.
- The operator shall not touch battery container and the patient simultaneously.
- When the device is in use, there should not be any great power appliances such as high voltage cables, X-ray machine, ultrasound equipment and electrizer nearby.
- Electromagnetic field are capable of interfering with the proper performance of the thermometer. Therefore, make sure that all external devices operated in the vicinity of the thermometer comply with the relevant EMC requirements. Wireless communications equipment such as wireless home network devices, mobile phones, cordless telephones and their base stations, walkie-talkies or MRI devices are a possible source of interference as they may emit higher levels of electromagnetic radiation.
- Don’t near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high.
- Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.
- Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.”
- Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the equipment, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
- any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State.
Precaution
- Please follow some instructions offered in Cleaning and Maintenance to clean the thermometer.
- Remove the battery when the thermometer will not be used for a long time.
- The thermometer contains high quality precision parts; do not crash the thermometer and avoid severe shock or vibration; do not twist the thermometer or its sensor.
- Seek medical treatment in time in case of dysphoria, vomiting, diarrhea, dehydration, appetite or behavioral pattern changes of unknown reasons.
- Please note the storage and use conditions in the section of “Product Specifications”.
- Protect the thermometer sensor from dirt and dust.
Description of graphic symbols
Symbol | Description | Symbol | Description |
---|---|---|---|
Caution | Upward | ||
Keep dry | Keep away from sunlight | ||
Type BF applied part | Fragile, handle with care | ||
Serial number | Date of manufacture | ||
Limit four-storey | No step | ||
Disposal instructions for electronic devices | Refer to instruction manual | ||
Use-by date | Atmospheric pressure | ||
Manufacturer | Medical Device | ||
CE Mark And Identification Number Of Notified Body |
Authorized Indicates the authorized representative European Community
| Catalogue number
| Protected against solid foreign objects of 12.5mmφand greater Protection
against vertically falling water drops when ENCLOSURE tilted up to 15°
Environmental protection
The company designs and manufactures products for body temperature measurement according to the safety and environmental protection requirements. The equipment will not cause any harm to people or the environment if any outer cover of the product is not taken apart or the equipment is always used in a correct way. When materials that are potentially hazardous to the environment must be used, as permitted by laws and regulations, they must be handled in the right way.
Warning:
Do not dispose wastes generated by the thermometer products with industrial or
household waste together, please use separate collection facilities. Please
handle wastes generated by thermometer equipment based on proper method and
dispose of instruments when they reach its service life in accordance with
local and national environmental regulations. Please make recycling use of
wastes if they are reusable after handled by qualified company to reduce
environmental pollution. Related issues please refer to the company’s
services, or deal with them in the proper way according to local garbage
collection requirements.
Product Description
Intended Purpose
Medical Indications
Infrared forehead thermometer is an infrared thermometer intended for the measurement of human body temperature in people of all ages without contact to the body and may be used by medical professionals or by consumers in a home environment.
Contraindication
N/A
Intended patient population
The device is intended for adults and infants, except premature.
Intended Users
The device is intended to be used by medical professionals or lay person who
can express themself normally.
Clinical benefits to be expected
Ensure accuracy of the measurement.
Residual Risks and Undesirable Side-effects
Residual risks and undesirable side-effects that may be related to the use of infrared forehead thermometer can include but may not be limited to the following:
- Incorrect measurement result
- Cross infection
- Electrical shock
- User poison
- Environment pollution
- Fire or explode
- Inconvenience to user, such as too noisy, poor usability, inaudible sound, too hot surface
- Delay measurement, such as Damage of integrity, Short circuit, Electromagnetic interference, No output, Can not normally work, Can not normally operate, Button or shell failure, LCD failure, Wrong operation
Structural composition
The infrared forehead thermometer is composed of display, mode button, sensor probe, on/off button, bottom shell, memory button.
Product photo
Component | Function |
---|---|
On/off button | Turn on the product.Start to measure the temperature |
Memory button | Review the stored temperature values. Set the voice.Delete the |
stored temperature values.
Mode switch button| Switch among body mode, calibration mode and room
mode.Switch between ℃ and ℉.
Display| Display measurement value and symbols
Bottom shell| Protect the battery, PCBA
Sensing probe| Measure temperature
Display screen
1. Body mode symbol | 6. Decimal point |
---|---|
2. Calibration mode symbol | 7. Memory group |
3. Room mode symbol | 8. Memory icon |
4. Low-power icon | 9. Sound icon |
5. Unit icon | 10.Temperature display value |
Packing list
Names of articles | Quantity |
---|---|
Instruction manual, including warranty card and certificate of conformity | 1 |
9V dry battery | 1 |
Main engine | 1 |
※ Product packaging should contain the items described above. In case of any
shortage, please contact Shenzhen LEPU Intelligent Medical Equipment Co., Ltd.
or the agent distributor in time.
Why the Infrared Forehead Thermometer is Required?
Quick
With the innovative infrared technology, it can quickly measure the body temperature in non-contact mode
Accurate and reliable
By measuring the heat energy emitted from the forehead and calculating the
body
temperature accordingly, accurate readings can be obtained as long as it is
held within a range of 5cm when measuring.
Simple and easy to use
The infrared forehead thermometer is about inductive measurement. It can easily measure the body temperature, even for sleeping children. Compared with the rectal thermometer, a non-contact frontal thermometer can reduce the discomfort of children, and it is simpler and more practical than other thermometers in use.
Safe and hygienic
Contactless measurement can prevent the spread of bacteria; It is absolutely safe for children and adults;
Shenzhen LEPU Intelligent Medical Equipment Co., Ltd.
Manufacturer address: North side of floor 3, BLD 9 Bai Wangxin High-Tech
Industrial Park Song bai Road, Xili Street, Nanshan District 518055 Shenzhen,
Guangdong, CHINA
Tel: +86 0755-86952278
Fax: +86 0755-86952278
Customer Service
E-mail: service@lepu-medical.com
Website: www.lepucare.com
Company name: Lepu Medical (Europe) Cooperatief U.A. Company address: Abe
Lenstra Boulevard 36, 8448 JB, Heerenveen, The Netherlands
Tel:+31 – 515 – 573399 Fax:+31 – 515 – 760020
Product Installation and Use
Check
Please check the packing case carefully before unpacking. In case of any
damage
found, please contact the carrier immediately. Open the package correctly,
take out the infrared forehead thermometer and other components from the case
with care, and check them one by one against the packing list. When the
equipment is moved a different environment, the difference in temperature or
humidity may lead to condensation to it, in which case no use is allowed
before condensation disappears.
Install or replace batteries
The first step after unpacking is to install the battery. The battery holder is on the back of the infrared thermometer. The battery installation steps are as follows:
- Open the battery cover.
- Insert the battery and keep +, – poles of the battery in line with +, – poles of the battery holder.
- Close the battery cover.
Note:
Please use 9V dry battery. Remove the battery if the thermometer will not be used for a long time. When the symbol“ ” appearing on the screen indicates that the battery runs out. Please replace the battery before measuring.
Starting up
Press the “ON/OFF” button, then the backlight of the screen comes on, the LCD
is shown in full screen and displays the latest group of memory values, the
equipment enters the waiting state for measurement; If there is no operation
for about 60 seconds, the equipment will enter standby state.
Placement
Place the thermometer between the eyebrows, at a distance within 5cm from the center of the forehead; In non-contact mode, the blue pilot light will point to the area you are aiming at. If the eyebrow area is covered by hair, sweat or dirt, please clean it in advance to improve the accuracy of the reading. Keep the thermometer and forehead still when measuring, as movement will negatively affect the temperature reading.
Mode switch
At power-on state, switch to select Body mode / Calibration mode or Room mode
while pressing “mode” button;
Remark: The default mode is body mode.
Unit switch
At power-on state, press“ mode ”button for about 2 seconds to free convert
between ℃ to °F. The current setting will be saved by default.
Note:
If there is no operation for 60 seconds, the equipment will enter idle state.
The latest setting will be saved by default.
Body temperature measurement
Press” ON/OFF” button to enter measurement state, place the thermometer
within 5cm from the forehead. Press “ON/OFF” button again when two concentric
circles are overlapping and projecting in the middle of eyebrows and eyes (as
below), and then can see the temperature displayed on the screen after a “bi”
(no “bi” if the sound is shut down) in about 1 second. The number of memory
groups will show at the right down corner at the same time.
Note:
When the measured temperature is below 37.5 ℃, the LCD backlight is green.
When the measured temperature is between 37.5℃-38.5℃, the LCD backlight is
yellow, reminding of low fever. When the measured temperature is higher than
38.5 ℃, the LCD backlight is red, reminding of high fever with sound of “Bi”,
“Bi”, “Bi”
Object temperature measurement
Press “ON/OFF” button and then press “mode” switch to calibration mode, point
at the object and press “ON/OFF” button again when two concentric circles are
overlapping. Then the object temperature will display on the screen after a bi
(no “bi” if the sound is shut down) in about 1 second. The number of memory
groups will show at the right down corner at the same time.
Note:
When the measured temperature is <40.0℃, the LCD backlight is green; when the
measured temperature is ≥40.0℃, the LCD backlight is red and gives a warning
with sound of “Bi”, “Bi”, “Bi”.
Ambient temperature measurement
Press“ ON/OFF” button and then press“ mode” button switch to room mode, press
“ON/OFF” button again, LCD screen will show current ambient temperature.
Memory query
Press“ memory ”button briefly (no matter what state), the screen displays“- –
–
-M”and the symbol “M” flashes. Press“memory”button again, it displays with latest value + symbol“M”and number of groups. In body mode, different temperature ranges display with different backlights. In calibration mode, the backlight will turn to red when the temperature is over 40.0℃. While no memory, it displays “- – – – C+”M” and the backlight is green without human or object icon.
Memory deletion
In shutdown mode, press “memory” button for a long time, at the first 4 seconds, it will show up sound setting, please don’t release and keep pressing for another 4 seconds (up to 8seconds), then can delete memory values with flashing “CLr+M” on the screen. It will shut down automatically after three “Bi-Bi-Bi”.
Low battery indicator
When low voltage icon shows, please replace batteries before measuring.
Shutdown/Idle
If there is no operation, the equipment will enter idle state and switch to
room mode and the LCD displays the current ambient temperature. And no further
operation, it will shut down automatically in 60 minutes.
Standby state: LCD displays ambient temperature and the equipment enters low-power consumption mode. Shutdown: Nothing on the LCD screen and the equipment enters to sleep mode.
Special Instructions for Safe Use
You should know the normal body temperature of individuals when they are healthy, which will help you to accurately judge whether they have a fever. To get the normal body temperature, please take more measurements when they are healthy. The normal temperature of childr
en can be as high as 37.7°C or as low as 36.1°C. Please confirm it with a standard electronic thermometer. The human body can regulate the temperature to keep the normal body temperature within a certain fluctuation range, up to 1°C within a day. Besides, the internal temperature of the human body, i.e. the body core temperature, is different from the surface temperature of the skin, so we cannot simply define what temperature is “normal”, as the body temperature is always in connection with to the measurement site. The level of body temperature is also affected by ambient temperature, age, sleep time, hormonal readiness and physical activity.
Note:
Note:
Avoid taking the temperature until stay in the room for 30 minutes (the
subject to be measured and the infrared forehead thermometer should be at the
same ambient temperature for at least 30 minutes). Keep the infrared forehead
thermometer and forehead still when measuring, do not move the thermometer
before the last beep is heard. Do not take the baby’s temperature immediately
after breastfeeding. Wait a few minutes before taking the temperature after
waking up. Do not eat, drink or do any other physical activity before or
during the temperature measurement. If there is a hat on head, please take it
off and wait for 10 minutes before taking the temperature. Please clean the
dirt or hair on forehead before taking the temperature. Front bangs may cause
readings to rise. Wait for 10 minutes before taking the temperature after
cleaning the forehead. Please take the temperature in strict accordance with
the instructions. Temperature readings may be affected by improper placement.
For the following circumstances, it is recommended to measure the same site
three times, and take the highest one as the final.
- Newborn babies less than 100 days old.
- Children under three years old, with low immunity and greatly affected by fever on health.
- The user learns to use the infrared forehead thermometer for the first time, who has little knowledge about the operation and fails to get stable readings.
If patients intend to take body temperature by their own, we recommend contact measurement.
Calibration
The infrared forehead thermometer has been calibrated before delivery from the
factory. If you have any doubt about its accuracy, please contact the customer
service. We recommend technical inspection for the measurement every two
years, and it is required to comply with the applicable national regulations
of the local place. Technical inspection for the measurement may be carried
out by the government agencies in charge or by authorized fee-paying
maintenance services.
Troubleshooting
The infrared forehead thermometer has been calibrated before delivery from the
factory. If you have any doubt about its accuracy, please contact the customer
service. We recommend technical inspection for the measurement every two
years, and it is required to comply with the applicable national regulations
of the local place. Technical inspection for the measurement may be carried
out by the government agencies in charge or by authorized fee-paying
maintenance services.
Measured temperature too high
Error message on screen| Meaning of show| Possible causes and
solutions
---|---|---
| Measured body temperature is too high (above 43.0℃/109.4°F)| The result
exceeds the measurement range limit
| Measured object temperature is too high(above 100℃/212°F)| The result
exceeds the measurement range limit
Measured temperature too low
Error message on screen| Meaning of show| Possible causes and
solutions
---|---|---
| Measured body temperature is too low (below 32.0℃/89.6°F)| The result
exceeds the measurement range limit
| Measured object temperature is too low (below 0℃/32.0°F)| The result exceeds
the measurement range limit
Ambient temperature out of range
Error m essage on screen| Meaning of show| Possible causes and
solutions
---|---|---
| The ambient temperatureis lower than 5℃/41°F| Move to another warm room
| The ambient temperatureis higher than 40℃/104°F| Move to another cold room
Other error messages
Error message on screen| Meaning of show| Possible causes
and solutions
---|---|---
| Eeprom error| Please contact the after-sales service.
| Measurement environment is not stable| 1.Please wait for 10~30 minutes;
2.Don’t touch sensor whenwaiting;
Cleaning and Maintenance
Clean with a dry soft cloth. If the engine is particularly dirty, wipe with a wet and wrung out cloth and then dry it with a dry cloth. Disinfect the product only when necessary; disinfection is recommended to carry out by wiping the product surface twice with disinfectant. Do not soak or use gas for disinfection. Use of medical alcohol is recommended.
If necessary, clean the infrared forehead thermometer first when repeated measurement of the body temperature is required. Clean the thermometer shell and sensor with alcohol swab or cotton ball dipped in alcohol (70%), and be careful to avoid liquid entering the thermometer. No use of corrosive detergent, diluent or benzene solvent is allowed. Do not immerse the thermometer in water or other cleaning solutions of any kind.
Do not expose the equipment to high temperature, high humidity, dust or direct sunlight
Warranty Service
Warning
- Manufacturer will provide circuit diagrams, component part lists, descriptions, calibration instructions to assist to SERVICE PERSONNEL in parts repair. Remove the battery when the thermometer will not be used for a long time.