Sytong XS-LRF Series Handheld Thermal Imaging Instruction Manual
- June 11, 2024
- Sytong
Table of Contents
XS-LRF Series Handheld Thermal Imaging
Instruction Manual HANDHELD THERMAL IMAGING
XS-LRF SERIES INSTRUCTION MANUAL
Shenzhen Shi Yutong Technology Co., LTD
XS-LRF Series Handheld Thermal Imaging
1, Lens Cover
2, Lens Focusing Ring
3, Power ON/OFF Button
4, Navigation UP Button
5, MENU Button
6, Navigation DOWN Button
7, LED Indicator
(GREEN = Power On, RED = Charging)| 8, Eyepiece Focusing Ring
9, Red Laser Pointer
10, Laser Rangefinder
11, Storage Card Compartment
12, Hand Strap
13, Objective Lens
14, Eyepiece Lens
15, Battery Cap
---|---
In The Box
- XS-LRF HANDHELD THERMAL IMAGING
- Type-C Cable
- Manual
- 18650 Lithium Battery
- 5V2A Adapter
- Hand Strap
Quick Start
Power On and Image Settings
- Hold the power (ON/OFF) button (3) for 3 seconds to power on.
- Rotate the eyepiece focusing ring (8) to get a clear image of the icons on the display.
- Rotate the lens focusing ring (2) to get a clear image of the observed object.
- Press the navigation UP button (4) to select the operating modes (White Hot, Black Hot, Sky Mode, Red Hot, Fusion).
- Press the navigation DOWN button (6) to select digital magnification (lx, 2x, 4x, 8x).
- Press the MENU button (5) to enter the menu to select the appropriate parameter.
- Hold the power (ON/OFF) button (3) for 3 seconds to power off. The LED indicator will be turned off after the device is powered off.
Button
Power (ON/OFF) Button
Hold the power (ON/OFF) button (3) for 3 seconds to power off. The LEO
indicator will be turned off after power off.
Hold the power (ON/OFF) button (3) for 1.2 seconds to go into sleep mode. The
110 indicator will be green when the device is in sleep mode. Wake the device
by pressing the power (ON/OFF) button. ‘Press the power button to refresh the
device
↑ Navigation UP button
In menu mode:
Press to switch menu items upwards.
When not in menu mode:
Press to change the operating modes.
Hold 1-3s to take a picture; Hold 3s to start/stop recording
MENU Button
In menu mode:
Press to confirm selection.
Hold to exit main menu or submenu.
When not in menu mode: Press to enter menu mode.
Hold to turn on or off the red laser pointer.
↓ Navigation DOWN Button
In menu mode: Press to switch menu items downwards.
When not in menu mode: Press to change set-up zoom lx,2x,4x,ex Hold to turn
on/off rangefinder
Menu Function
XS-LRF Detailed Functions
-
Operating Mode Options:
“White Hot”/”Sky Mode’/”Black Hot”/”Red Hot”/”Fusion” Default mode is “White Hot” -
Video Output
The video output function of the CVBS is enabled or disabled -
Wi-Fi
Options: “On”/”Off’
Turn on WiFi on both the device’s Menu and user’s phone.
On user’s phone, find and connect to “APPshow-XSLRF-XXX’s WiFi network with password 12345678.
Live image will be displayed on the App after the phone is connected to the device’s WiFi. -
Laser Rangefinder Unit
Options: “Meter/Yard” -
Laser Rangefinder Mode
L.Single distance measurement 2.,Continuous distance measurement -
OLED Brightness
Select “OLED Brightness in the main menu, press MENU button to set the screen brightness from”Super Dark/*Dark”/”Nommal”/’Bright”/”Super Bright”. The default mode is “Normal”, -
Target Brightness
Find the “Target Brightness” in the main menu. Press MENU button to choose from the S brightness levels (1-5). -
Contrast Ratio
Press the MENU button to enter the main menu and select “Contrast Ratio”. There are 10 options (1-10). -
Image Detail Boost
Press the MENU button to enter the main menu and select the “Image Detail Boost” function. Image resolution will vary according to each option. Press MENU button to choose your option. -
Date/Time
Move the options by pressing the MENU button. Change the value using the UP/DOWN button, Confirm the values by pressing the MENU button. Quit by holding the MENU button. -
Language
Enter the language menu setting, Save the settings by pressing the MENU button, -
Record Audio
Select “Record Audio” and press MENU button. Select “On* OH”. -
Format
Select “Format” under main menu, press the MENU button to format the memory storage in the device.
Attention! Data cannot be recovered after formatting! -
Auto Power Off
Select “Auto Power Off” under main menu, short press MENU button to set the mode between “3 Min”, “5 Min” and Off’.
The defualt made is “Off”. -
Default Setting
Find default settings under main menu, short press MENU button to enter the submenu.
Select “Confirm” to save the default settings. Attention ! Factory default settings will be saved after confirmation. -
Pixel Fix
Select “Pixel Fix” and press MENU button to get to the sub menu. The lens should be covered with lens cover before performing the pixel fix. Press the MENU button and follow the prompts to fix the bad pixels. After repair, please remember to save it .
Navigation key up, down move cursor, power button ta switch options, short press M key to save. -
Image Correction
Enter the menu of image correction. If image correction is required, select and confirm, close the lens cover, and press “M” ta correct the background image unifarmuty, After correction, it will automatically save and exit. -
Version
Select “Version’ to view the device’s software version.
APP Connection
Download APP by scanning the QR code using the phone’s camera app.
http://app.dayingtech.com/79819049674
XS03-LRF
Sensor (Military Grade)
Type | Uncooled |
---|---|
Frame Rate | 50 Hz |
NETD | <25mk |
Resolution | 384×288 Super Sensitive |
Pixel Size | 1211m |
Optical Characteristics
Objective Lens | f15/19/25/35mm, F/1.0 |
---|---|
Digital Zoom | 1x/2x/4x/8x |
Dioptre Adjustment | +5/-5 D |
FOV | 17.5°X13.1° / 13.8°X10.4° / 10.5°X7.9° / 7.5°X5.7° |
Magnification | 1.2x/1.5x/2.0x/2.8x |
Eye Relief | 30 mm |
Close-up Range | 5m-co |
Display
Operating Mode | White Hot , Sky Mode , Black H ot,Red Hot, Fusion |
---|---|
Type / Resolution | 0.39 inch / OLED / 1024X768 |
Operational Characteristics
Power Supply | 3-4.2 V |
---|---|
External Power Supply | 5V (USB) |
Operating Temperature | – 20°C to + 50°C |
Weight(Without Battery /Mount) | 390g |
Waterproof Rating | IP66 |
Battery | 18650 /3200mAh |
Dimensions | 156X68X75mm |
Operating Time
(At Temperature Of 22°C)| 5 hours
Video Recorder
Video / Photo resolution | 1024)(768 |
---|---|
Memory Type | Built-in 32G Memory Card |
Video / Photo Format | .mp4 /. jpg |
Wi- fi Channel
Frequency | 2.4GHz |
---|---|
WiFi Signal Range | 15m |
Standard | 802.11 b/g |
Rangefinder
Wavelength | 905nm |
---|---|
Measuring Accuracy | +/- im |
Max. Measuring Range | 1200m |
Detection Distance (Targt Size :1.7m x 0.5m) | 750m/955m/1250m/1750mm |
Notice!
Operating Instructions For Accessories
Power Adapter
Used only to charge batteries equal to or below 5V/2A.
Red Laser Pointer Adjustment
Hold the MENU button to turn on/off the red laser pointer. Adjust the position
of the red laser pointer by using an inner hexagon wrench.
FCC Warning Statement:
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment. This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The
device can be used in portable exposure condition without restriction.
Follow Sytong official account to learn more
Website: https://www.sytong2013.com