GARDENA 4100 Silent Garden Pump Owner’s Manual

June 11, 2024
Gardena

GARDENA-LOGO

GARDENA 4100 Silent Garden Pump

GARDENA-4100-Silent-Garden-Pump-PRODUCT

Product Information

GARDENA Gartenpumpe 4100 Silent / 4200 Silent / 4300 Silent
The GARDENA Gartenpumpen 4100 Silent/4200 Silent/4300 Silent are garden pumps that are designed to pump water from wells, tanks, or other water sources to irrigate gardens or lawns, or for use in household applications such as washing cars or filling pools. The pumps come in three models with different maximum pressure levels: 2.4 bar for the 4100 model, 2.1 bar for the 4200 model, and 1.7 bar for the 4300 model. The pumps are equipped with a suction filter to prevent debris from entering the pump.

Product Usage Instructions

Safety Instructions
Before using the pumps, read the operator’s manual carefully and follow all safety instructions.

Assembly

  1. Screw the vacuum-resistant suction hose (2) tightly onto the suction side connection (1) of the pump. The suction hose should be laid straight and without any twists.
  2. Connect the pressure hose (4) to the pressure side connection (3) of the pump. Use the appropriate hose diameter and connector depending on the pump connection size.

Operation

  1. To start the pump, connect the suction hose and remove the pressure hose. The pump will start automatically after a suction process that may take up to 5 minutes.
  2. If the pump does not start after 5 minutes, check for any air leaks in the suction hose connections, and ensure that the suction hose is not kinked or twisted.
  3. To stop the pump, turn off the power switch or disconnect the power supply.

Maintenance

  1. Regularly clean the suction filter to prevent clogging and damage to the pump.
  2. Check for any air leaks in the suction hose connections and repair them if necessary.
  3. Lubricate the pump bearings and shaft seal according to the instructions in the manual.
  4. Store the pump in a dry, closed, and frost-proof place.
  5. Dispose of the pump according to local regulations.

Troubleshooting

If the pump is not working properly, refer to the troubleshooting table in the manual for possible solutions.

SAFETY WARNINGS

Explanation of the symbols

  • Read operator’s manual.

General safety warnings

General pump safety warnings

DANGER: Electric shock!

Risk of injury due to electric current.

  • The product must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • Disconnect the product from the mains before you put it into storage, maintain it or replace parts. Thereby the disconnected socket must be in the visual range.

Garden pump safety warnings

Safe operating practices

  • The water temperature should not exceed 35 °C.
  • The pump must not be used when people are in the water.
  • Pollution of the liquid could occur due to leakage of lubricants.

Circuit breakers
Thermal protection switch
In the event of an overload, the pump is switched off by the built-in thermal motor protection. After sufficient cooling of the motor, the pump is operational again.

Additional safety warnings

Intended use

This product may be used under supervision, or if instruction regarding the safe use of the product has been provided and the resulting dangers have been understood, by children aged 8 and above, as well as by persons with physical, sensory or mental disabilities or a lack of experience and knowledge. Children must not be allowed to play with the product. Cleaning and user maintenance shall not be carried out by children unless they aged 8 years and above and supervision.The use of this product by young people under the age of 16 is not recommended.

The GARDENA Garden pump is intended to pump ground water and rain water, tap water and water containing chlorine in private domestic gardens and allotments.

  • The product is not intended for long term use (professional use).
  • The product is not intended for continuous running.

Liquids to be pumped
The GARDENA Garden Pump must only be used to pump water.

DANGER Risk of injury
The pump must not be used for the delivery of salt water, muddy water, corrosive, easily inflammable or explosive liquids (e. g. petrol, paraffin, thinners), oil, heating oil or foodstuffs.

Pressure amplification
The inlet pressure must be protected by an adjustable pressure relief valve. When the pump is used for pressure amplification, the maximum permissible internal pressure must not exceed 6 bar. The maximum inlet pressure is therefore

  • GARDENA Garden pump 4100 Art. 9050 v Max: 2.4 bar
  • GARDENA Garden pump 4200 Art. 9054 v Max:  2.1 bar
  • GARDENA Garden pump 4300 Art. 9056 v Max:  1.7 b

Additional electrical safety warnings

DANGER Cardiac arrest: This product makes an electromagnetic field while it operates. This field may under some conditions interfere with active or passive medical implants. To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medical implant manufacturer before you operate the product.

The pump must be installed in a stable and flood-proof location and protected against falling into the water. Take care that the pump cannot fall into water.
Position the pump at a safe distance (min. 2 m) from the liquid to be pumped.
As an additional safety device an authorised safety switch can be used.

  • Ask your electrician for his advice.
    If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  • Protect the mains plug and the mains power cable from heat, oil and sharp edges.

  • Do not use the power cable for carrying the pump or for unplugging.

  • Place the pump in a flood-proof location.

  • Please regularly check the connecting line.

  • Before using, always subject the pump (especially the power cables and the power connections) to a visual inspection. A pump which is damaged must not be used.

  • In the event of damage, have the pump checked by GARDENA Service.
    Electrical changes are only conducted by an electrical specialist.

  • Before filling, dismantling, maintenance disconnect the mains.

  • When using our pumps with a generator, the warnings of the generator manufacturer must be observed.

Cables
If extension cables are used, these must comply with the minimum cross- sections in the table below:

Additional personal safety warnings
DANGER Risk of suffocation:
Small parts can be easily swallowed. There is also a risk that the polybag can suffocate toddlers.

  • Keep toddlers away when you assemble the product.

DANGER: Risk of injury from hot water

Pumped water is under pressure and when it hits the body or eyes directly can cause injury.
If the pump is operated for prolonged periods of time (> 5 min.) with the delivery side closed, the water in the pump may heat up so that there is a risk of scalding yourself with hot water.

  • Let the pump operate for max. 5 minutes against the closed pressure side or with missing water supply.
    If the water supply on the intake side of the pump fails, the water in the pump can heat up so that if water emerges, injuries could be caused by the hot water.

  • Disconnect the pump from the mains and let the water cool.

  • Do not open any caps and screw connections when the water is hot.

  • Before restarting, secure the water supply on the suction side and fill the pump completely with water.
    If hoses or pipes are exposed to the sun, they can become very hot.
    Do not use the product with loose hair.
    When connecting the pump to the water supply system, the country-specific sanitary regulations must be observed to prevent water not of drinking water quality being drawn back in.

  • Consult a specialist for sanitary installations.
    In order to avoid dry-running of the pump, take care that the end of the suction hose is always submerged into the liquid.

  • Before each operation, fill the pump with water up to the overflow (min. 1.1 l)!

  • When filling the pump with water, make sure that no hoses or consumers are connected to the pump and that the pump is generally in a horizontal position.

  • Make sure that the hoses are laid without kinks. Sand and other abrasive substances cause increased wear and reduce the pump’s output.

  • Use a pump pre-filter for pumping sandy liquids. Pumping dirty water, e. g. stones, pine needles etc., can cause damage to the pump.

  • Do not pump dirty water. The minimum flow rate is 90 l/h (1.5 l/min). Connection devices with a lower flow rate must not be operated.

ASSEMBLY

DANGER Risk of injury: Risk of injury due to accidental starting.

  • Unplug the plug of the mains cable from the mains socket.

Installation site:

  • When installing below the water level, a shut-off device must be installed to prevent unwanted water loss.
  • The installation site must be horizontal, solid and dry and allow the pump to stand securely.
  • It must be at a distance of at least 2 m from the water.
  • The pump must be installed in a flood-proof location with sufficient ventilation in the area of the ventilation slots.
  • The distance to the walls must be at least 5 cm.
  • Dirt (e. g. sand or soil) must not be sucked in through the ventilation slots.

To connect the hose to the suction side [ Fig. A6 ]
The connector on the suction side (1) is equipped with a 33.3 mm (G 1″) external thread.
The connection piece on the suction side may only be tightened by hand [ Fig. A2 ].
In order to reduce the suction time, it is advisable to use a suction hose with backflow preventer avoiding automatic draining of the suction hose when the pump has been switched off [ Fig. A3 ].
Sucking in air in the suction system can lead to functional failure and increased noise generation.

  • Connect the suction system carefully.

  • Check the gasket regularly and replace it if necessary.
    Don’t use any hose quick connection system fittings on the suction side.
    A vacuum-resistant suction hose must be used on the suction side:

    • e. g. the GARDENA Suction Unit Art. 1411 / 1412 / 1418
    • or the GARDENA Bore Hole Suction Hose Art. 1729.
  • Connect suction hoses (2) without threaded connection via a suction hose connection piece (e. g. Art. 1723 / 1724) to the connection of the suction side and screw it airtight.

There are 2 types of connection systems :

Intended for flat gasket: No thread sealing tape is required.

  • Make sure that the flat gasket ßG is inserted in the suction hose connection piece and is undamaged.

Intended for thread sealing tape (hemp/Teflon)

No flat gasket is required. An unsuitable sealing system can lead to leaks.

  • Use the sealing system intended for this purpose.
  1. Make sure that the flat gasket ßG is inserted in the suction hose connection piece.
  2. Screw the vacuum-resistant suction hose (2) airtight on the connector on the suction side (1). The connection piece must be placed straight on [ Fig. A1 ].
  3. Lay the suction hose (2) straight and free of twists.
  4. For suction heights exceeding 3 m: Fix the suction hose (2) additionally. (e. g. by fastening it to a wooden post).
    Therefore, the pump is relieved of the weight of the suction hose

To connect the hose to the pressure side [ Fig. A7 ] The connector on the pressure side (3) is equipped with a 33.3 mm (G 1″) external thread.

The connection pieces on the pressure side may only be tightened by hand
Optimised use of the pump capacity is achieved by connecting 19 mm (3/4″) hoses with

  • e. g. the GARDENA Pump Connection Set Art. 1752
  • or by connecting 25 mm (1″) hoses with the GARDENA Quick Thread Coupling with female thread Art. 7109 / Quick Coupling Hose Connector Art. 7103.

Hold or fix the pressure hose vertically to avoid kinking of the pressure hose at the vertical pump outlet.
Lay the hose flat on the ground; avoid u-shaped elevations of the hose and coiling it. In order to allow the air to escape optimally, lay out the pressure hose completely and give it a rising course as seen from the pump.

  • Connect the pressure hose (4) with the connector on the pressure side (3).

To connect the pressure hose via the GARDENA quick connection system
19 mm (3/4″) / 16 mm (5/8″) and 13 mm (1/2″) hoses can be connected via the GARDENA Connection System.

GARDENA-4100-Silent-Garden-Pump-FIG-3

Only for Art. 9056: Parallel connection of pressure hoses:
When connecting more than one pressure hose in parallel, we recommend the use of:

  • e. g. the GARDENA 2- or 4-Channel Water Distributor Art. 8193 / 8194
  • or the GARDENA Twin-Tap Connector Art. 940.

These can be screwed directly onto the connector of the pressure side (3).

OPERATION

DANGER Risk of injury: Risk of injury due to accidental starting.

  • Unplug the plug of the mains cable from the mains socket.

To start / To stop the pump [ Fig. O1 / O2 ]:

CAUTION: Dry-Running of the pump.
Make sure that the pump is filled with water up to the overflow (min. 1.1 l) before each starting procedure.

To start the pump:

  1. Connect the suction hose (In).

  2. Disconnect the pressure hose (Out).

  3. Unscrew the screw connection (5) on the filling opening (6) by hand.

  4. Slowly fill in at least 1.1 l of water via the filler opening (6) until a stable water level is reached at the level of the suction side connection [ Fig. A4 ].

  5. If a non-return valve is used: Fill the suction hose with water.
    This speeds up the suction process.

  6. Empty the residual water in the pressure hose (4) before connecting. This allows the air to escape during the suction process.

  7. After filling the pump: Connect the pressure hose (Out) to the pump.

  8. Tighten the screw connection (5) on the filling opening (6) by hand (do not use pliers).

  9. Open any shut-off valves in the pressure line (connection devices, water stop, etc.). All consumers must be opened to the max. possible position.

  10. Insert the plug of the mains cable into a mains socket.

  11. For high suction heights: Lift and hold the pressure hose (4) at least 1.8 m vertically above the pump during the suction process.

  12. Push the On / Off switch (7) to the position On.

The pump starts (the On/Off switch lights) and pumps the water after the suction process.
The suction process can take up to 5 minutes.

If the pump does not pump water after 5 minutes:

  1. Push the On / Off switch (7) to the position Off. The pump stops.
  2. Let the pump cool down.
  3. Search in the 6.2 Troubleshooting table for possible causes.
  4. Start the pump again (see 3.1.1 To start the pump).

To stop the pump:

  • Push the On/Off switch (7) to the position Off. The pump stops
Hints to pump

General tip on suction
The specified maximum self-priming height is only reached when the pump is filled to the overflow via the filling opening and the pressure hose (4) is held upwards during the priming process so that no water can escape from the pump via the pressure hose (4). Fill the pump before hoses, fixed piping etc. are connected to the pump on the pressure side.
This ensures that the pump can be completely filled with water (1.1 l) (air can escape).

The pump is to be filled with 1.1 l of water

Silent operation:
The pump is silent. This advantage can only be maintained with the correct installation:

  • Choose a low-vibration base (e. g. do not place on metal sheets or plastic tanks).

Assembly of the prefilter
If a prefilter is too long, it can be assembled in another position (e. g. horizontally) instead of in the vertical position still below.

MAINTENANCE

DANGER Risk of injury: Risk of injury due to accidental starting.

  • Unplug the plug of the mains cable from the mains socket

To clean the Pump:
DANGER Risk: Risk of injury and risk of damage to the product.

  • Do not clean the product with water or with a water jet (in particular high-pressure water jet).
  • Do not clean with chemicals including petrol or solvents. Some can destroy critical plastic parts.

The airflow slots must always be clean

  1. Clean the pump housing with a damp cloth.
  2. Clean the airflow slots with a soft brush (do not use sharp objects).

To flush the pump:
After pumping chlorinated water, the pump must be flushed.

  1. Pump through lukewarm water (max. 35 °C), possibly adding a mild cleaning agent (e. g. detergent) until the pumped water runs clear.
  2. Dispose of the residues in accordance with local waste disposal regulations.

STORAGE

To put into storage [ Fig. S1 ]

CAUTION: Damage to the pump due to frost!

  • Store the pump in a frost-free place.

The product must be stored away from children

  1. Unplug the plug of the mains cable from the mains socket.

  2. Close any shut-off valves in the suction line.

  3. Open any shut-off valves in the pressure line (accessories, water stop, etc.).
    Therefore the pressure line is depressurized.

  4. Unscrew the screw fitting (5) of the filler neck (6) and the water drain screw (8) by hand.
    Therefore the pump is drained.

  5. Tilt the pump in the direction of the drain (approx. 45°) so that the pump empties completely.

  6. Unscrew the suction hose and the pressure hose.

  7. Tighten the screw connection (5) on the filling opening (6) and the water drain screw (8) by hand (do not use pliers).

  8. Clean the pump (see 4. MAINTENANCE).

  9. Store the pump in a dry, enclosed and frost-free place.

TROUBLESHOOTING

DANGER Risk: of injury
Risk of injury due to accidental starting.

  • Unplug the plug of the mains cable from the mains socket.

To loosen the impeller [ Fig. T1 ]

An impeller blocked by dirt can be loosened.

  • Turn the shaft of the impeller (9) clockwise with an insulated screwdriver.
    Therefore the blocked impeller is loosened.

Troubleshooting table

GARDENA-4100-Silent-Garden-Pump-FIG-4GARDENA-4100-Silent-Garden-Pump-FIG-5GARDENA-4100-Silent-Garden-Pump-FIG-6GARDENA-4100-Silent-Garden-Pump-FIG-7

NOTE: Repairs must only be done by the GARDENA service departments or specialist dealers approved by GARDENA.

  • For any other malfunctions please contact the GARDENA service department.

TECHNICAL DATA

GARDENA-4100-Silent-Garden-Pump-
FIG-8

ACCESSORIES / SPARE PARTS

GARDENA-4100-Silent-Garden-Pump-FIG-9

SERVICE

Please contact the address on the back page.

DISPOSAL

Disposal of the pump: (according to Directive 2012/19/EU)
The product must not be disposed of to normal household waste. It must be disposed of in line with local environmental regulations.

IMPORTANT: Dispose of the product through or via your local recycling collection centre.

Declaration of Conformity
The undersigned hereby certifies as the authorized representative of the manufacturer, GARDENA Germany AB, PO Box 7454,
S-103 92, Stockholm, Sweden, that, when leaving our factory, the unit(s) indicated below is / are in accordance with the harmonised
EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the unit(s) is / are modified without our approval.

Description of the product: Garden Pump

  • Product type
  • Directives
  • Article number
  • GARDENA Technical: Procedure:
  • Noise level: measured / guaranteed

CONTACT

info@agroland.eu
Canada / USA
GARDENA Canada Ltd. 100 Summerlea Road Brampton, Ontario L6T 4X3
Phone: (+1) 905 792 93 30
info@gardenacanada.com

Iceland BYKO ehf. Skemmuvegi 2a 200 Kópavogur
Phone: (+354) 515 4000
byko@byko.is

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals