FLARE FIREPLACES Outdoor Vent Free Large Double Corner Fireplace Owner’s Manual

June 11, 2024
FLARE FIREPLACES

FLARE FIREPLACES Outdoor Vent Free Large Double Corner Fireplace

FLARE-FIREPLACES-Outdoor-Vent Free-Large-Double-Corner-Fireplace-
product

Unit Dimensions

FLARE-FIREPLACES-Outdoor-Vent Free-Large-Double-Corner-
Fireplace-fig- \(1\)

Model 50 60 70 80 100
A- Inch 54 2/16 62 13/16 70 11/16 80 14/16 99
B- Inch 52 14/16 61 9/16 69 7/16 79 11/16 97 13/16
C- Inch 27 6/16 27 6/16 27 6/16 27 6/16 27 6/16
D- Inch 16 16 16 16 16

Cavity Dimensions

FLARE-FIREPLACES-Outdoor-Vent Free-Large-Double-
Corner-Fireplace-fig- \(2\)

  X Y Z
50 Inch 54 2/16 31 6/16
mm 1375 797 422
60 Inch 62 13/16 31 6/16
mm 1595 797 422
70 Inch 70 11/16 31 6/16
mm 1795 797 422
80 Inch 80 14/16 31 6/16
mm 2054 797 422
100 Inch 99 31 6/16
mm 2515 797 422

Appliance Considerations

FLARE-FIREPLACES-Outdoor-Vent Free-Large-
Double-Corner-Fireplace-fig- \(3\)

Drainage

Flare Fireplaces Vent Free lines are outdoor rated using Stainless Steel, corrosion resistant materials. However, care should be taken to ensure rain and other moisture cannot collect between the unit and the mounting platform. Plan for drainage to run outside of the cavity away from other fixed buildings and objects.

Electrical Connection

  • 110V AC (15 AMP dedicated recommended but not required) power source must be provided to run the fireplace. An electrical connection needs to be provided to the right of the unit and utilize a Ground Fault Circuit Interrupter (GFCI/GFI) outlet is required.
  • Ensure a switch is installed to control power to an outlet for control over the fireplace.

Gas Supply

Gas should be run into the right side of the unit. Flex pipe will be provided within the unit, but hard piping should be done into the fireplace box.

Manual Gas Shut Off

Required on all outdoor unit installations. The manual Gas Shut off must be visible (after finishing) and remain accessible in the event of an emergency. Consult city,\ state and other local codes to confirm additional requirements as needed.

Clearance to Floor

Flare Ventless line must maintain box opening at least 11” above any combustible flooring. For fireplaces which are considering being mounted lower, flooring must be non-combustible material (i.e. stone, tile, cement, etc.)

Finishing Fireplace

FLARE-FIREPLACES-Outdoor-Vent Free-Large-Double-
Corner-Fireplace-fig- \(4\)

Index Description Dimension from the fireplace opening
A From the ground or another combustible surface 11”
C From Opening to Ceiling (minimum) 36” from top opening
D Alcove Width (minimum) 36” +36” (side opening)
E Non-Combustible Board above opening (side and front opening) 8”
F In front of the opening, short and long 36”

See Installation Manual for all clearances and requirements. Type-X is not allowed as a non-combustible board over appliance opening

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FLARE FIREPLACES User Manuals

Related Manuals