Flare Fireplaces 50 Outdoor Vent Free Large Right Corner Fireplace Owner’s Manual
- June 9, 2024
- FLARE FIREPLACES
Table of Contents
Flare Fireplaces 50 Outdoor Vent Free Large Right Corner Fireplace
Unit Dimensions
Model | 50 | 60 | 70 | 80 | 100 |
---|---|---|---|---|---|
A- Inch | 55 8/16 | 64 2/16 | 72 | 82 4/16 | 100 6/16 |
B- Inch | 52 14/16 | 61 9/16 | 69 7/16 | 79 11/16 | 97 13/16 |
C- Inch | 27 6/16 | 27 6/16 | 27 6/16 | 27 6/16 | 27 6/16 |
D- Inch | 16 | 16 | 16 | 16 | 16 |
Cavity Dimensions
X | Y | Z | |
---|---|---|---|
50 | Inch | 57 8/16 | 31 6/16 |
mm | 1461 | 797 | 422 |
60 | Inch | 66 2/16 | 31 6/16 |
mm | 1680 | 797 | 422 |
70 | Inch | 74 | 31 6/16 |
mm | 1880 | 797 | 422 |
80 | Inch | 84 4/16 | 31 6/16 |
mm | 2140 | 797 | 422 |
100 | Inch | 102 6/16 | 31 6/16 |
mm | 2600 | 797 | 422 |
Appliance Considerations
Drainage- Flare Fireplaces Vent Free line are outdoor rated using Stainless Steel, corrosion resistant materials. However, care should be taken to ensure rain and other moisture cannot collect between unit and mounting platform. Plan for drainage to run outside of cavity away from other fixed buildings and objects.
Electrical Connection- 110V AC (15 AMP dedicated recommended but not required) power source must be provided to run fireplace. Electrical connection needs to be provided to the right of the unit and utilize a Ground Fault Circuit Interrupter (GFCI/GFI) outlet required. Ensure switch is installed to control power to outlet for control over fireplace.
Gas Supply- Gas should be run into the right side of the unit. Flex pipe will be provided within unit, but hard piping should be done into fireplace box.
Manual G a s Shut Off- Required on all outdoor unit installations. Manual Gas Shut off must be visible (after finishing) and remain accessible in the event of an emergency. Consult city, state and other local codes to confirm additional requirements as needed.
Clearance to Floor- Flare Ventless line must maintain box opening at least 11” above any combustible flooring. For fireplaces which are considering being mounted lower, flooring must be non-combustible material (i.e. stone, tile, cement, etc.)