orangjo VC701 Voltage Tester User Guide

June 11, 2024
Orangjo

VC701 Voltage Tester

orangjo-VC701-Voltage-Tester-product-image

Voltage Tester – VC701

The VC701 is a voltage tester designed for measuring both AC and DC voltage. It is important to read the following information and guidelines prior to using the device to prevent electric shock, health damages, or loss of life.

Safety Guidelines

  1. Thoroughly read the operating manual and terms of safe use before using the device.
  2. Check for damages on device’s casing or measuring cables before commencing measurements. If any damage is detected, the device should not be used as it may pose an electric shock threat.
  3. The device should not be used when insulation wrapping the probes and cables is damaged.
  4. Only use gauging cables delivered with the set for measurements. If gauging cables are damaged, they should be replaced with cables of exact technical parameters.
  5. The device can only be used for measurements compliant with the manual and its technical specification. Otherwise, device’s safety provisions may not be sufficient for safe usage.
  6. During measurements, do not touch any metal ends. Keep fingers above insulation sheaths.
  7. Do not make measurements with wet hands.
  8. The device should not be used or kept in high air humidity or temperature conditions, in strong electromagnetic field, or in an explosive or flammable environment. Such conditions may influence gauging results and create an electric shock hazard.
  9. Store the device in a place inaccessible for children.
  10. Do not use the device directly after it is relocated from a room with high air humidity, excessively low or high temperature conditions.

Technical Specification

  • Voltage tester
  • Indication of DC voltage polarization
  • Optical voltage indicators
  • AC/DC voltage measurement
  • Safety category: CAT IV

Product Usage Instructions

  1. Apply the ,,+ meter tip to the active part of the circuit (L).
  2. Apply the tip of the test lead to the neutral part of the circuit (N).
  3. Read the voltage value with the illuminated diode on the meter housing.

General information

Voltage tester for measuring AC and DC voltage.

Safety guidelines

  1. Prior to initiation of device’s usage it is recommended to get thoroughly acquaint-ed with operating manual and terms of safe use. This will allow avoiding an electric shock, health damages or loss of life, as well as it may prevent damages to the device.
  2. Prior to commencing measurements it is recommended to check for damages on device’s casing or measuring cables. In case any cable or device damages are detected device should not be used, as it may pose an electric shock threat.
  3. The device should not be used when insulation wrapping the probes and cables is damaged.
  4. Only gauging cables delivered with the set may be used for measurements. In case gauging cables are damaged they should be replaced with cables of exact technical parameters.
  5. The device can be used only for measurements compliant with the manual and its technical specification. Otherwise, device’s safety provisions may not be sufficient for safe usage.
  6. During measurements all metal ends should not be touched. Fingers should be kept above insulation sheaths.
  7. It is not allowed to make measurements with wet hands.
  8. The device should not be used, or kept, in high air humidity or temperature conditions, in strong electromagnetic field or in an explosive or flammable environment. Such conditions may influence gauging results and create an electric shock hazard.
  9. Device should be used and stored in a place inaccessible for children.
  10. Device should not be used directly after it is relocated from a room with high air  humidity, excessively low or high temperature conditions.

Specification

Measurement accuracy for particular gauging values is given for 1 year from calibration date and for an operating temperature of 23ºC º5ºC and air humidity of 75%.

  • Accuracy: +-% of indicated value  number of least significant digits. 3.5 digit LCD display.
  • Power supply: 23A battery (DC 12 V º ).
  • Number of readouts: 2 readouts per second .
  • Buzzer .
  • Dimensions: 102 x 60 x 24 mm .
  • Operating conditions: from 0ºC to 40º, air humidity: < 80% .
  • Storage conditions: from – 10ºC to +50ºC, air humidity < 85% .
  • Weight: approx. 60 g .
  • Kit includes: multimeter, gauging cables, battery (a test battery – not covered by the guarantee), operating manual.

Safety category

  • CAT I – gauging category CAT I defines safety requirements for measurements in  devices which are not connected directly to a low voltage network, such as batteries, accumulators, flashlights.
  • CAT II – gauging category CAT II defines safety requirements for measurements carried out in devices directly connected to a low voltage network, such as home appliances, office equipment or workshop equipment.
  • CAT III – gauging category CAT III defines safety requirements for measurements carried out in the circuits of installations inside buildings.
    Multimeter should not be used for measurements of devices defined by CAT IV.

Description

  1.  indication of DC voltage polarization
  2. optical voltage indicators

AC/DC voltage measurement

  1. Apply the „+” meter tip to the active part of the circuit (L).
  2. Apply the tip of the test lead to the neutral part of the circuit (N).
  3. Read the voltage value with the illuminated diode on the meter housing 2.

When measuring alternating current, the +/– polarity is indicated 1.

Electromalt Limited
15, Level 1, Suite 4, Naxxar Road, Birkirkara, BKR9049
Malta
Tel. 00356 77028874
Website: www.electromalt.com
Email: [email protected]

Please refer to the local collection and segregation rules for electrical and electronic equipment. Observe the regulations and do not dispose electrical and electronic equipment  with cosumer waste. Proper disposal of used products helps to reduce their harmful effects on the environment and human health.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Orangjo User Manuals

Related Manuals