DeWALT DXCMLA1683066 Air Compressor Instruction Manual
- June 11, 2024
- Dewalt
Table of Contents
DXCMLA1683066 Air Compressor
Product Information: Air Compressor
- Air Compressor with a 30-gallon tank capacity
- Weight: 165 lbs. (75 kg)
- Approx. blow off pressure: 175 psi
- Pump Specifications: 2 Cylinder, Single Stage, Oil Lubricated, Cast iron crankcase, cylinder, and aluminum head
- Comes with Pump Air Intake Filter, Auto(-)/Off(O) Switch, Air Tank Pressure Gauge, Regulated Pressure Gauge, Pressure Regulator, Air Outlet, Safety Valve, Air Tank Drain Valve, Pump Oil Fill Plug, Pump Oil Drain Plug, Check Valve, and Quick Connect
Product Usage Instructions:
- Before using the air compressor, read the instruction manual for safety, operation, and maintenance instructions.
- Make sure to place the compressor in a well-ventilated area that is free of combustible materials, gasoline, or solvent vapors.
- Locate the compressor at least 20′ (6.1 m) away from any spray area when using with flammable vapors.
- Do not operate the unit in any confined area. Store indoors.
- Make sure to keep the compressor away from any hot surfaces such as compressor cylinder & head, pump crankcase, and outlet tube.
- The air compressor comes with various parts such as Pump Air Intake Filter, Auto(-)/Off(O) Switch, Air Tank Pressure Gauge, Regulated Pressure Gauge, Pressure Regulator, Air Outlet, Safety Valve, Air Tank Drain Valve, Pump Oil Fill Plug, Pump Oil Drain Plug, Check Valve, and Quick Connect. Use these parts as per the instructions provided in the manual.
- Make sure to keep the compressor in a clean, dry, and well-ventilated area.
- Do not allow the compressor to operate unattended to prevent any risk of fire or explosion.
- Keep the compressor away from any contact with flammable materials.
- Make sure to store the compressor in a secure location away from any children.
Air Compressor
- A. Pump Air Intake Filter
- B. Auto(-)/Off(O) Switch
- C. Air Tank Pressure Gauge
- D. Regulated Pressure Gauge
- E. Pressure Regulator
- F. Air Outlet
- G. Safety Valve
- H. Air Tank Drain Valve
- I. Pump Oil Fill Plug
- J. Pump Oil Drain Plug
- K. Check Valve
- L. Quick Connect
Pump Specifications
- 2 Cylinder
- Single Stage
- Oil Lubricated
- Cast iron crankcase, cylinder, and aluminum head Weight: 30.5 lbs (13.8 kg.)
- Oil Capacity: 13 oz. (384 mL)
Specifications
MODEL | DXCMLA1683066 |
---|---|
WEIGHT | 165 lbs. (75 kg) |
HEIGHT | 48″ |
WIDTH | 24.12″ |
AIR TANK CAPACITY | 30 gallons (113,6 liters) |
APPROX. BLOW OFF PRESSURE | 175 psi |
Hot Surfaces
Definitions: Safety Guidelines
The definitions below describe the level of severity for each signal word.
Please read the manual and pay attention to these symbols.
- DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
- WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
- CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
- NOTICE: Indicates a practice not related to personal injury which, if not avoided, may result in property damage.
IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR ANY DEWALT TOOL, CALL US TOLL FREE AT: 1-888-895-4549
Important Safety Instructions
- WARNING: Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions.
- WARNING: CONTAINS LEAD. May be harmful if eaten or chewed. May generate dust containing lead. Wash hands after use. Keep out of reach of children.
- WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
SAVE THESE INSTRUCTIONS
DANGER: RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN
- It is normal for electrical contacts within the motor and pressure switch to spark.
- If electrical sparks from com-pressor come into contact with flammable vapors, they may ignite, causing fire or explosion.
- Restricting any of the com-pressor ventilation openings will cause serious overheat-ing and could cause fire.
- Unattended operation of this product could result in personal injury or property dam-age. To reduce the risk of fire, do no allow the com-pressor to operator unat-tended
HOW TO PREVENT IT
- Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors.
- If spraying flammable materials, locate compressor at least 20′ (6.1 m) away from spray area. An additional length of air hose may be required.
- Store flammable materials in a secure location away from compressor.
- Never place objects against or on top of compressor.
- Operate compressor in an open area at least 12” (30.5 cm) away from any wall or obstruction that would restrict the flow of fresh air to the ventilation openings.
- Operate compressor in a clean, dry well ventilated area. Do not operate unit in any confined area. Store indoors.
- Always remain in attendance with the product when it is operating.
- Always turn off and unplug unit when not in use.
DANGER: RISK TO BREATHING (ASPHYXIATION)
WHAT CAN HAPPEN
- The compressed air directly from your compressor is not safe for breathing. The air stream may contain carbon monoxide, toxic vapors, or solid particles from the air tank. Breathing these contaminants can cause serious injury or death.
- Exposure to chemicals in dust created by power sanding, sawing, grinding, drilling and other construction activities may be harmful.
- Sprayed materials such as paint, paint solvents, paint remover, insecticides, weed killers, may contain harmful vapors and poisons.
HOW TO PREVENT IT
- Never use air obtained directly from the compressor to supply air for human consumption. The compressor is not equipped with suitable filters and in-line safety equipment for human consumption.
- Work in an area with good cross ventilation. Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying. Always use certified safety equipment: NIOSH/OSHA respiratory protection or properly fit ting face mask designed for use with your specific application.
DANGER: RISK OF BURSTING
Air Tank: On February 26, 2002, the U.S. Consumer Product Safety
Commission published Release # 02-108 concerning air compressor tank safety:
Air compressor receiver tanks do not have an infinite life. Tank life is
dependent upon several factors, some of which include operating conditions,
ambient conditions, proper installations, field modifications, and the level
of maintenance. The exact effect of these factors on air receiver life is
difficult to predict.
If proper maintenance procedures are not followed, internal corrosion to the
inner wall of the air receiver tank can cause the air tank to unexpectedly
rupture allowing pressurized air to suddenly and forcefully escape, posing
risk of injury to consumers.
Your compressor air tank must be removed from service by the end of the year
shown on your tank warning label.
The following conditions could lead to a weakening of the air tank, and result
in a violent air tank explosion:
WHAT CAN HAPPEN
-
Failure to properly drain condensed water from air tank, causing rust and thinning of the steel air tank.
-
Modifications or attempted repairs to the air tank.
-
Unauthorized modifications to the safety valve, or any other components which control air tank pressure.
Attachments & Accessories: -
Exceeding the pressure rating of air tools, spray guns, air operated accessories, tires and other inflatables can cause them to explode or fly apart, and could result in serious injury.
-
Over inflation of tires could result in serious injury and property damage.
HOW TO PREVENT IT
- Drain air tank daily or after each use. If air tank develops a leak, replace it immediately with a new air tank or replace the entire compressor.
- Never drill into, weld or make any modifications to the air tank or its attachments. Never attempt to repair a damaged or leaking air tank. Replace with a new air tank.
- The air tank is designed to withstand specific operating pressures. Never make adjustments or parts substitutions to alter the factory set operating pressures.
- Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Never use compressor to inflate small low pressure objects such as children’s toys, footballs, basketballs, etc.
- Use a tire pressure gauge to check the tires pressure before each use and while inflating tires; see the tire sidewall for the correct tire pressure.
NOTE: Air tanks, compressors and similar equipment used to inflate tires can fill small tires very rapidly. Adjust pressure regulator on air supply to no more than the rating of the tire pressure. Add air in small increments and frequently use the tire gauge to prevent over inflation.
DANGER: RISK OF INJURY OR PROP ER TY DAMAGE WHEN TRANSPORTING OR STORING
WHAT CAN HAPPEN
- Oil can leak or spill and could result in fire or breathing hazard; serious injury or death can result. Oil leaks will damage carpet, paint or other surfaces in vehicles or trailers.
HOW TO PREVENT IT
- Always place compressor on a protective mat when transporting to protect against damage to vehicle from leaks. Remove compressor from vehicle immediately upon arrival at your destination. Always keep compressor level and never lie on its side.
WARNING: RISK FROM FLYING OBJECTS
WHAT CAN HAPPEN
- The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles and small objects at high speed, resulting in property damage or personal injury.
HOW TO PREVENT IT
- Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields when using the compressor.
- Never point any nozzle or sprayer toward any part of the body or at other people or animals.
- Always turn the compressor off and bleed pressure from the air hose and air tank before attempting maintenance, attaching tools or accessories.
WARNING: RISK OF HOT SURFACES
WHAT CAN HAPPEN
- Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns.
HOW TO PREVENT IT
- Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation
- Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
WARNING: RISK OF ELECTRICAL SHOCK
WHAT CAN HAPPEN
- Your compressor is powered by electricity. Like any other electrically powered device, if it is not used properly it may cause electric shock.
- Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
- Electrical Grounding: Failure to provide adequate grounding to this product could result in serious injury or death from electrocution. Refer to Grounding Instructions paragraph in the Installation section.
HOW TO PREVENT IT
- Never operate the compressor outdoors when it is raining or in wet conditions.
- Never operate compressor with protective covers removed or damaged.
- Any electrical wiring or repairs required on this product should be per-formed by authorized ser-vice center personnel in accordance with national and local electrical codes.
- Make certain that the electrical circuit to which the compressor is connected provides proper electrical grounding, correct voltage and adequate fuse protection.
WARNING: RISK OF UNSAFE OPERATION
WHAT CAN HAPPEN
- Unsafe operation of your air compressor could lead to serious injury or death to you or others.
HOW TO PREVENT IT
- Review and understand all instructions and warnings in this manual.
- Be come familiar with the operation and controls of the air compressor.
- Keep operating area clear of all persons, pets, and obstacles.
- Keep children away from the air compressor at all times.
- Do not operate the product when fatigued or under the influence of alcohol or drugs. Stay alert at all times.
- Never defeat the safety fea tures of this prod uct.
- Equip area of operation with a fire extinguisher.
- Do not operate machine with missing, broken, or un authorized parts.
- Never stand on the compressor.
WARNING: RISK FROM MOVING PARTS
WHAT CAN HAPPEN
- Moving parts such as the pulley, flywheel, and belt can cause serious injury if they come into contact with you or your clothing.
- Attempting to operate compressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury.
HOW TO PREVENT IT
- Never operate the compressor with guards or covers which are damaged or removed.
- Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.
- Air vents may cover moving parts and should be avoided as well.
- Any repairs required on this product should be performed by a DEWALT factory service center or a DEWALT authorized service center.
WARNING: RISK OF INJURY FROM LIFTING
WHAT CAN HAPPEN
- Serious injury can result from attempting to lift too heavy an object.
HOW TO PREVENT IT
- The compressor is too heavy to be lifted by one person. Obtain assistance from others before lifting.
CAUTION: RISK FROM NOISE
WHAT CAN HAPPEN
- Under some conditions and duration of use, noise from this product may contribute to hearing loss.
HOW TO PREVENT IT
- Always wear certified safety equipment: ANSI S12.6 (S3.19) hearing protection.
SAVE THESE INSTRUCTIONS FOR FUTURE USE
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare
the illustrations with your unit to familiarize yourself with the location of
various controls and adjustments. Save this manual for future reference.
FEATURES
AUTO (-) / OFF (O) SWITCH
Place this switch (B) in the AUTO (-) position to provide automatic power to
the pressure switch and OFF(O) to remove power at the end of each use.
NOTE: ALWAYS ensure the switch (B) is in the OFF (O) position before
removing or replacing pressure switch cover. PRESSURE SWITCH
The pressure switch (B) automatically starts the motor when the air tank
pressure drops below the factory set cut-in pressure. It stops the motor when
the air tank pressure reaches the factory set cut-out pressure.
SAFETY VALVE
This valve (G) is designed to prevent system failures by relieving pressure
from the system when the compressed air reaches a predetermined level. The
valve is preset by the manu-facturer and must not be removed or modified in
any way.
CHECK VALVE
When the air compressor is operating, the check valve (K) is open, allowing
compressed air to enter the air tank. When the air compressor reaches cut-out
pressure, the check valve closes, allowing air pressure to remain inside the
air tank.
AIR INTAKE FILTERS
The filters (A) are designed to clean air entering the pump. To ensure the
pump continually receives a clean, cool, and dry air supply the filters must
always be clean and the filter intakes must be free from obstructions
.
AIR TANK DRAIN VALVE
The drain valve (H) is located at the base of the air tank and is used to
drain condensation at the end of each use. See Draining Air Tank under
Maintenance.
REGULATED PRESSURE GAUGE
The regulated pressure gauge (D) indicates the air pressure available at the
outlet side of the regulator. This pressure is controlled by the regulator and
is always less or equal to the air tank pressure.
TANK PRESSURE GAUGE
The tank pressure gauge (C) indicates the reserve air pressure in the tank.
UNIVERSAL QUICK CONNECT BODY
The universal quick connect body (L) accepts the three most popular styles of
quick connect plugs: Industrial, automotive, and ARO. One hand push-to-connect
operation makes connections simple and easy.
REGULATOR
The regulator knob (E) controls the air pressure coming from the air tank.
To Adjust Regulator:
Turn knob clockwise to increase regulated pressure and counterclockwise to
decrease regulated pressure.
WARNING: Risk of Bursting. Too much air pressure causes a hazardous risk
of bursting. Check the manufacturer’s maximum pressure rating for air tools
and accessories. The regulator outlet pressure must never exceed the maximum
pressure rating.
AIR COMPRESSOR PUMP
The pump compresses air into the air tank. Working air is not available until
the compressor has raised the air tank pressure above that required at the air
outlet.
MOTOR OVERLOAD PROTECTOR
The motor has a thermal overload protector. If the motor overheats for any
reason, the overload protector will shut off the motor. The motor must be
allowed to cool down before restarting.
To restart:
- Set the Auto/Off switch to OFF (O) and unplug unit.
- Allow the motor to cool.
- Depress the red reset button (N) on the motor.
- Plug the power cord into the correct branch circuit receptacle.
- Set the Auto/Off switch to AUTO (-).
INSTALLATION
Assembly (Fig. 1)
Unpack the air compressor. Inspect the unit for damage. If the unit has been
damaged in transit, contact the carrier and complete a damage claim. Do this
immediately because there are time limitations to damage claims.
The carton should contain:
- Air compressor
- Operator and parts manuals
Check the compressor’s serial label to ensure that you have received the model ordered, and that it has the required pressure rating for its intended use.
INSTALLING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand when installing
or disconnecting to prevent hose whip.
- Ensure regulated pressure gauge reads 0 psi.
- Apply sealant tape to hose threads.
- Assemble hose to air outlet (F).
IMPORTANT: Do not assemble splitters directly to the air outlet (F).
NOTE: Assembling quick connect bodies (L) to air outlet (F) and quick connect plugs to hose ends make connecting and disconnecting hoses simple and easy. Quick connect bodies and plugs are available for purchase from your local dealer or authorized service center.
DISCONNECTING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand when installing
or disconnecting to prevent hose whip.
- Ensure regulated pressure gauge reads 0 psi.
- Remove hose from air outlet (F).
Lubrication and Oil
AIR COMPRESSOR
The air compressor pump was filled WITH oil at the manufacturer. Check air
compressor pump oil level before operating unit. See Compressor Pump Oil under
Maintenance.
Compatibility
Air tools and accessories that are run off the compressor must be
compatible with petroleum based products. If you suspect that a material is
not compatible with petroleum products, an air line filter for removal of
moisture and oil vapor in compressed air is required.
NOTE: Always use an air line filter to remove moisture and oil vapor when
spraying paint.
Location
-
Locate the air compressor in a clean, dry, and well ventilated area.
-
Located the air compressor at least 12” (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air.
-
Locate the air compressor as close to the main power supply as possible to avoid using long lengths of electrical wiring.
NOTE: Long lengths of electrical wiring could cause power loss to the motor. -
The air filters must be kept clear of obstructions which could reduce air flow to the air compressor.
HUMID AREAS
In frequently humid areas, moisture may form in the pump and produce sludge in
the oil, causing running parts to wear out prematurely. Excessive moisture is
especially likely to occur if the unit is located in an unheated area that is
subject to large temperature changes. Two signs of excessive humidity are
external condensation on the pump when it cools down and a “milky” appearance
in compressor oil. You may be able to prevent moisture from forming in the
pump by increasing ventilation or operating for longer intervals.
Wiring Instructions
- WARNING: Improper electrical installation of this product may void its warranty and your fire insurance. Have circuit wiring performed by qualified personnel such as a licensed electrician who is familiar with the current national electrical code and any prevailing local electrical codes.
- WARNING: Risk of electrical shock. Improper electrical grounding can result in electrical shock. The wiring should be done by a qualified electrician.
A qualified electrician needs to knows the following before wiring:
- The amperage rating of the electrical box should be adequate. Refer to the Specifications, in the parts manual, for this information.
- The supply line should have the same electrical characteristics (voltage, cycle, phase) as the motor. Refer to the motor nameplate, on side of motor, for this information.
NOTE: The wiring used must be rated for the motor nameplate voltage, plus
or minus 10%. Refer to local codes for recommended wire sizes, correct wire
size, and maximum wire run; undersize wire causes high amp draw and
overheating to the motor.
WARNING: Risk of electrical shock. Electrical wiring must be located away
from hot surfaces such as manifold assembly, compressor outlet tubes, heads,
or cylinders.
Grounding Instructions
WARNING: Risk of electrical shock. In the event of a short circuit, grounding
reduces the risk of shock by providing an escape wire for the electric
current. This air compressor must be properly grounded. O
The portable air compressor is equipped with a cord having a grounding wire
with an Q appropriate grounding plug.
-
The cord set and plug (O) with this unit contains a grounding pin (P). This plug MUST be used with a grounded outlet (Q). IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.
-
Ensure the outlet being used has the same configuration as the grounded plug.
DO NOT USE AN ADAPTER.
Inspect the plug and cord before each use. Do not use if there are signs of damage. -
If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.
DANGER: Risk of electrical shock. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.- Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.
- Repairs to the cord set or plug MUST be made by a qualified electrician.
Extension Cords
If an extension cord must be used, be sure it is:
- A 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product
- In good condition
- Plug is not worn
- No longer than 50 feet (15.2 m)
- 12 gauge (AWG) or larger. (Wire size increases as gauge number decreases. 10 AWG and 8 AWG may also be used. DO NOT USE 14 OR 16 AWG.)
NOTICE: The use of an undersized extension cord will cause volt-age to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed. Always use a minimum 3/8” (9.5 mm) or greater air hose rated at 300 psi.
Voltage and Circuit Protection
Refer to the Voltage and Minimum Branch Circuit Requirements under
Specifications.
CAUTION: Certain air compressors can be operated on a 15 amp circuit if
the following conditions are met.
- Voltage supply to circuit must comply with the National Electrical Code.
- Circuit is not used to supply any other electrical needs.
- Extension cords comply with specifications.
- Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse.
NOTE: If compressor is connected to a cir-cuit protected by fuses, use only time delay fuses. Time delay fuses should be marked “D” in Canada and “T” in the U.S.
If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.
How to Use Your Unit (Fig 3)
How to Stop:
Set the Auto/Off switch to “Off”.
Before Starting
WARNING: Do not operate this unit until you read this instruction manual for
safety, operation and maintenance instructions.
Break-in Procedure
NOTICE: Risk of property damage. Serious damage may result if the following
break-in instructions are not closely followed.
This procedure is required before the air compressor is put into service and
when the check valve or a complete compressor pump has been replaced.
-
Make sure the Auto/Off switch is in the “Off” position.
-
Check oil level in pump. See Oil paragraph in the Maintenance section for instructions.
-
Plug the power cord into the correct branch circuit receptacle.(Refer to Voltage and Circuit Protection paragraph in the installation section of this manual.)
-
Open the drain valve (counterclockwise) fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period.
-
Move the Auto/Off switch to “Auto” position. The compressor will start.
Run the compressor for 30 minutes. Make sure the drain valve and all air lines are open so there is only a minimal air pressure build-up in tank.
NOTE: After about 30 minutes, If the unit does not operate properly, SHUT DOWN IMMEDIATELY, and contact Product Service. -
Check all air line fittings and connections/piping for air leaks by applying a soap solution. Correct if necessary.
NOTE: Minor leaks can cause the air compressor to overwork, resulting in premature breakdown or inadequate performance. -
Check for excessive vibration.
-
After 30 minutes, turn the Auto/Off switch to the “Off” position.
-
Close the drain valve.
-
Turn the Auto/Off switch to the “Auto” position. The air receiver will fill to “cut-out” pressure and the motor will stop. The compressor is now ready for use.
Before Each Start-Up
- Place Auto/Off switch to “Off”.
- Close the drain valve.
- Visually inspect air lines and fittings for leaks.
- Check safety valve. See To Check Safety Valve under Maintenance.
- Turn the regulator knob counterclockwise to set the outlet pressure to zero.
- Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip.
WARNING: Risk of unsafe operation. Do not use damaged or worn accessories.
NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.
WARNING: Risk of bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.
CAUTION: Risk of unsafe operation. Compressed air from the unit may contain wa ter condensation and oil mist. Do not spray un fil tered air at an item that could be damaged by moisture. Some air tools and accessories may require filtered air. Read the instructions for the air tools and accessories.
How to Start
- Turn the Auto/Off switch to “Auto” and allow tank pressure to build. Motor will stop when tank pressure reaches “cut-out” pressure.
- Turn the regulator knob clockwise to increase pressure.
IMPORTANT: When using regulator and other accessories refer to the manufacturers instructions.
WARNING: Risk of bursting. If any unusual noise or vibration is noticed, stop the compressor immediately and have it checked by a trained service technician.
The compressor is ready for use.
Shut-down (Fig. 1)
-
Move Auto/Off switch to the OFF position.
NOTE: If finished using compressor, follow Steps 2 – 6. -
Turn the regulator knob counterclockwise until fully closed. Ensure regulated pressure gauge reads 0 psi.
-
Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip. -
Drain the air tank, see Draining Air Tank under Maintenance.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will condense in air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. -
Allow the compressor to cool down.
-
Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
Maintenance Chart
Procedure| Daily| Weekly| Monthly| 1 year
or 100 Hours
| See tank warning label
---|---|---|---|---|---
Check safety valve| X| | | |
Inspect air filter| | X+| | |
Drain air tank| X| | | |
Check pump oil level| X| | | |
Change pump oil| | | | X *+|
Oil leak inspection| X| | | |
Inspect drive belt| X| | | |
Check drive belt tension| | | X| |
Check pulley/flywheel alignment| | | | X|
Check for unusual noise/vibration| X| | | |
Check for air leaks| X| | | |
Clean compressor exterior| | X| | |
Remove tank from service| | | | | X++
- To check for air leaks apply a solution of soapy water around joints. While compressor is pumping to pressure and after pressure cuts out, look for air bubbles to form.
** The pump oil must be changed after the first 20 hours or operation. Thereafter, when using full synthetic non-detergent air compressor oil, change oil every 100 hours of operation or once a year, whichever comes first.
+ Perform more frequent in dusty or humid conditions.
++ For more information, call 1-888-895-4549 .
WARNING: Risk of unsafe operation. Unit cycles automatically when power
is on. When performing maintenance, you may be exposed to voltage sources,
compressed air, or moving parts. Personal injuries can occur. Before
performing any maintenance or repair, disconnect power source from the
compressor and bleed off all air pressure.
To ensure efficient operation and longer life of the air compressor outfit, a
routine maintenance schedule should be prepared and fol-lowed. The following
routine maintenance schedule is geared to an outfit in a normal working
environment operating on a daily basis. If necessary, the schedule should be
modified to suit the condi-tions under which your compressor is used. The
modifications will depend upon the hours of operation and the working
environment. Compressor outfits in an extremely dirty and/or hostile
environment will require a greater frequency of all maintenance checks.
NOTE: See Operation section for the location of controls.
Checking Safety Valve (Fig. 1)
- WARNING: Hot surfaces. Risk of burn. Tubes, pump head, and surrounding parts are very hot, do not touch (see the Hot Surfaces identified in Fig. 2). Allow compressor to cool prior to servicing.
- WARNING: Risk of bursting. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion.
- WARNING: Risk from flying objects. Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
Checking Air Filter (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Tubes, pump head, and surrounding parts
are very hot, do not touch (see the Hot Surfaces identified in Fig. 2). Allow
compressor to cool prior to servicing.
A dirty air filter will not allow the compressor to operate at full capacity.
Keep the air filter clean at all times.
- Ensure Auto/Off switch (B) is in the OFF Position.
- Allow unit to cool.
- Remove the 2 wing nuts (R).
- Remove the outer metal covers (S).
- Check the filter elements (T) if they are dirty or filled with paint, replace them.
- Place the outer metal covers back over the filter elements
- Secure with the wing nuts.
CAUTION: Risk of unsafe operation. Do not operate without air filter.
Draining Air Tank (Fig. 3)
WARNING: Risk of unsafe operation. Air tanks contain high pressure air. Keep
face and other body parts away from outlet of drain. Use eye protection [ANSI
Z87.1 (CAN/CSA Z94.3)] when draining as debris can be kicked up into face.
WARNING: Risk from noise. Use ear protection (ANSI S12.6 (S3.19) as air
flow noise is loud when draining.
NOTE: All compressed air systems generate condensation that accu-mulates in any drain point (e.g., tanks, filter, aftercoolers, dryers). This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations.
-
Set the Auto/Off switch to “Off”.
-
Turn the regulator knob counterclockwise to set the outlet pressure to zero.
-
Remove the air tool or accessory.
-
Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.
-
Drain water from air tank by opening drain valve (counter clock-wise) on bottom of tank.
WARNING: Risk of bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
NOTICE: Risk of property damage. Drain water from air tank may contain oil and rust which can cause stains. -
After the water has been drained, close the drain valve (clock- wise). The air compressor can now be stored.
NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.
Compressor Pump Oil (Fig. 4)
- NOTICE: Risk of property damage. Use air compressor oil only. Multi-weight automotive engine oils like 10W30 should not be used in air compressors. They leave carbon deposits on critical compo-nents, thus reducing performance and compressor life.
- NOTE: Use full synthetic, non-detergent air compressor oil.
- NOTE: Crankcase oil capacity is approximately 13 fluid ounces (113,6 ml).
Checking
- The oil level should be to the middle of the sight glass (X).
- If needed remove oil fill plug (Y) and slowly add oil until it reaches the middle of the sight glass.
Changing
WARNING: Drain tank to release air pressure before removing the oil fill cap
or oil drain plug.
-
Remove the oil fill plug (Y).
-
Remove the oil drain plug (W) and drain oil into a suitable container.
-
Replace the oil drain plug (W) and tighten securely
-
Slowly add compressor oil until it reaches the middle of the sight glass (X).
NOTE: When filling the crankcase, the oil flows very slowly into the pump. If the oil is added too quickly, it will overflow and appear to be full.
CAUTION: Overfilling with oil will cause premature compressor failure. Do not overfill. -
Replace oil fill plug (Y) and tighten securely. Belt Replacement
WARNING: This unit starts automatically. ALWAYS shut off and unplug the compressor, and bleed all pressure from the system before servicing the compressor, and when the compressor is not in use. Do not use the unit with the shrouds or belt guard removed. Serious injury could occur from contact with moving parts. Hot surfaces. Risk of burn. Pump head, and surrounding parts are very hot, do not touch (see the Hot Surfaces identified in Fig. 2). Allow compressor to cool prior to servicing. -
Set the Auto/Off lever to “Off”, unplug the unit, and relieve all air pressure from the air tank.
-
Remove the front of the beltguard by removing the screws (Z) using a Torx T25 bit.
-
Mark motor position on saddle. Z
-
Loosen the motor mounting screws and slide the motor toward the air compressor.
-
Remove the belt and replace with a new one.
-
See the Adjusting Belt Tension before tightening motor mounting screws.
Adjusting Belt Tension
- Slide motor into original position, line the motor up with the mark made earlier on saddle.
- Tighten two outside motor mounting screws enough to hold the motor in place for checking pulley and flywheel alignment.
- The belt should deflect 1/2” (13 mm)at mid- way between the pul- ley and the flywheel when a 5 pound (2.26 kg.) weight is applied at the midway point.
- 3. When proper belt tension is achieved, tighten all four motor mounting screws. Torque to 20-25 ft-lbs (27.1–33.9 Nm). NOTE: Once the motor pulley has been moved from its factory set location, the grooves of the flywheel and pulley must be aligned to within 1/16” (1.6 mm) to prevent excessive belt wear. Verify the alignment by performing the following Motor Pulley/Flywheel – Alignment.
Motor Pulley/Flywheel Alignment
NOTE: Once the motor pulley has been moved from its factory set location, the
grooves of the flywheel and pulley must be aligned to within 1/16” (1.6 mm) to
prevent excessive belt wear.
The air compressor flywheel and motor pulley must be in-line (in the same plane) within 1/16” (1.6 mm) to assure belt retention within flywheel belt grooves.
To check alignment, perform the following steps:
- Set the Auto/Off lever to “Off”, unplug the unit, and relieve all air pressure from the air tank.
- Remove belt guard.
- Place a straightedge against the outside of the flywheel and the motor drive pulley.
- Measure the distance between the edge of the belt and the straightedge at points A1 and A2 in figure. The difference between measure- ments should be no more than 1/16” (1.6 mm).
- If the difference is greater than 1/16” (1.6 mm) loosen the set screw holding the motor drive pulley to the shaft and adjust the pulley’s position on the shaft until the A1 and A2 measurements are within 1/16” (1.6 mm) of each other.
- Tighten the motor drive pulley set screw.
- Visually inspect the motor drive pulley to verify that it is per-appendicular to the drive motor shaft. Points B1 and B2 of Figure should appear to be equal. If they are not, loosen the setscrew of the motor drive pulley and equalize B1 and B2, using care not to disturb the belt alignment performed in step 2.
- Retighten the motor drive pulley setscrew. Torque to 145–165 in lbs (16.4–20.3 Nm).
- Reinstall belt guard.
Air Compressor Pump Intake and Exhaust Valves
-
Once a year have a Trained Service Technician check the air com-pressor pump intake and exhaust valves.
Inspect Air Lines and Fittings for Leaks 1. Set the Auto/Off lever to “Off”, unplug the unit, and relieve all air pressure from the air tank. -
Apply a soap solution to all air line fittings and connections/piping.
-
Correct any leaks found.
IMPORTANT: Even minor leaks can cause the air compressor to overwork, resulting in premature breakdown or inadequate performance.
Air compressor Head Bolts – Torquing
The air compressor pump head bolts should be kept properly torqued. Check the
torques of the head bolts after the first five hours of operation. Torque to
8-11 ft.-lbs. (11-15 Nm).
Service and Adjustments
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED
SERVICE TECHNICIAN.
Risk of unsafe operation. Unit cycles automati-cally when power is on. When
servicing, you may be exposed to voltage sources, compressed air, or moving
parts. Before servicing unit unplug or disconnect electrical supply to the air
compressor, bleed tank of pressure, and allow the air compres-sor to cool.
To Replace or Clean Check Valve
-
Release all air pressure from air tank. See Draining Air Tank in the Maintenance section.
-
Set the Auto/Off lever to “Off”, unplug the unit, and relieve all air pressure from the air tank.
-
Using an adjustable wrench loosen outlet tube nut at air tank and pump. Carefully move outlet tube away from check valve.
-
Using an adjustable wrench loosen pressure relief tube nut at air tank. Carefully move pressure relief tube away from check valve.
-
Unscrew the check valve (turn counter-clockwise) using a 7/8” open end wrench.
NOTE the orientation for reassembly. -
Using a screwdriver, carefully push the In closed position valve disc up and disc is visible. down.
NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position, if not the check valve needs to be cleaned or replaced. -
Clean or replace the check valve. A solvent, such as paint or varnish remover can be used to clean the check valve.
-
Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).
-
Replace the pressure release tube. Tighten nuts.
-
Replace the outlet tube and tighten nuts.
-
Perform the Break-in Procedure. See Break-in Procedure in the Operation section.
Additional Service
Disassembly or service of the air compressor beyond what is cov-ered in this
manual is not recommended. If additional service is required, contact your
nearest Authorized Warranty Service Center.
Accessories
Recommended accessories for use with your tool are available for purchase from
your local dealer or authorized service center. If you need assistance in
locating any accessory for your tool, please call
1-888-895-4549 or visit our website
www.dewalt.com.
WARNING : The use of any other accessory not recommended for use with this tool could be hazardous. Use only accessories rated equal to or higher than the rating of the air compressor.
Service Information
Please have the following information available for all service calls:
- Model Number ____
- Serial Number ___
- Date and Place of Purchase ____
Repairs
To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment
should be performed by a DEWALT factory service center, a DEWALT authorized
service center or other qualified service personnel. Always use identical
replacement parts.
Limited Warranty
The Manufacturer warrants from the date of purchase.
2 Year – Limited warranty on oil-lubricated air compressor pumps.
1 Year – Limited warranty on all other air compressor components. This
warranty is not transferable to subsequent owners.
The Manufacturer will repair or replace, without charge, at their option, any
defects due to faulty materials or workmanship. For further detail of warranty
coverage and warranty repair information, call 1-(888)-895-4549 or visit
dewalt.com. This warranty does not apply to accessories or damage caused where
repairs have been made or attempted by others.
This warranty also does not apply to merchandise sold by the Manufacturer
which has been manufactured by and identified as the product of another
company, such as gasoline engines. Such manufacturer’s warranty, if any, will
apply. ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE OR EXPENSE THAT
MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT IS NOT
COVERED BY THIS WARRANTY. Some states do not allow the exclusion of limitation
of incidental or consequential damages, so the above limitation or exclusion
may not apply to you. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF
ORIGINAL PURCHASE. Some states do not allow limitations on how long an implied
warranty lasts, so the above limitations may not apply to you
What the Manufacturer Will Do: (the Manufacturer) will cover parts and labor to remedy substantial defects due to materials and workmanship during the first year of ownership, with the exceptions noted below. Parts used in repair of whole goods or accessories are warranted for the balance of the original warranty period.
What is not covered Under This Warranty? Failures by the original retail purchaser to install, maintain, and operate said equipment in accordance with standard industry practices. Modifications to the product, or tampering with components, or failure to comply with the specific recommendations of the Manufacturer set forth in the owner’s manual, will render this warranty null and void. The Manufacturer shall not be liable for any repairs, replacements, or adjustments to the equipment, or any costs for labor performed by the purchaser without the Company’s prior written approval. The effects of corrosion, erosion, surrounding environmental conditions, cosmetic defects, and routine maintenance items, are specifically excluded from this warranty. Routine maintenance items such as: oil, lubricants, and air filters, as well as changing oil, air filters, belt tensioning, etc…fall under the owner’s responsibility. Additional exclusions include: freight damage, failures resulting from neglect, accident, or abuse, induction motors when operated from a generator, oil leaks, air leaks, oil consumption, leaky fittings, hoses, drain valve, bleeder tubes, and transfer tubes.
- The following components are considered normal wear items and are not covered after the first year of ownership: Belts, pulleys, flywheels, check valves, pressure switches, air unloaders, throttle controls, electric motors, brushes, regulators, o-rings, pressure gauges, tubing, piping, fittings, fasteners, wheels, quick couplers, gaskets, seals, air filter housings, piston rings, connecting rods, and piston seals.
- Labor, service calls, and travel charges, are not covered after the first year of ownership on stationary compressors (compressors without handles, or wheels). Repairs requiring overtime, weekend rates, or any other charges beyond the standard shop labor rate are not covered.
- Time required for orientation training for the service center to gain access to the product, or additional time due to inadequate egress.
- Damage caused by incorrect voltage, improperly wired, or failure to have a certified licensed electrician install the compressor, will render this warranty null and void.
- Damage caused from inadequate filter maintenance.
- Pump wear or valve damage caused by using oil not specified.
- Pump wear or damage caused by any oil contamination.
- Pump wear or valve damage caused by failure to follow proper maintenance guidelines.
- Operation below proper oil level or operation without oil.
- Gas Engines, if product is equipped with a gas engine, see engine manual for specific engine manufacturer’s warrant cy overage.
Parts purchased separately:
The warranty for parts purchased separately such as: pumps, motors, etc.,
are as follows:
From Date of Purchase
- All single & two stage pumps 1 year
- Electric motors 90 days
- Universal motor/pump 30 days
- All other parts 30 days
- No return authorization will be issued for electrical components once items are installed.
How do You Get Service? In order to be eligible for service under this warranty you must be the original retail purchaser, and provide proof of purchase from one of the Manufacturer’s dealers, distributors, or retail outlet stores. Portable compressors or components must be delivered, or shipped, to the nearest Authorized Service Center. All associated freight costs and travel charges must be borne by the consumer. Please call our toll free number 1-888-895-4549 for assistance.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER
RIGHTS WHICH VARY FROM STATE TO STATE.
THE MANUFACTURER MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND
WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE. ALL IMPLIED
WARRANTIES, INCLUDING ANY WARRANTY OF ERCHANTABILITY AND FITNESS FOR
PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIABILITY FOR CONSEQUENTIAL AND
INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES, OTHER CONTRACTS, NEGLEGENCE,
OR OTHER TORTS IS EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW.
FREE WARNING LABEL REPLACEMENT : If your warning labels become illegible or are missing, call 1-888-895-4549 for a free replacement.
- WARNING HOT SURFACES: To reduce the risk of burns – Do not touch exposed metal surfaces.
- WARNING: CONTAINS LEAD. May be harmful if eaten or chewed. May generate dust containing lead. Wash hands after use. Keep out of reach of children.
- WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
098-3870 | CAUTION |
---|---|
Before starting, read and understand the operator manual for safe operation |
and maintenance.
| Risk of electric shock or injury —Use indoors only.
- Use a dedicated circuit. If connected to a circuit protected by a fuse, use time delay (marked D) fuses with this product.
| Risk of bursting —Do not adjust regulator to result in output pressure greater than the marked maximum pressure of attachment. Use only recommended air-handling parts acceptable for pressures not less than 200 psi.
- Rust weakens tank, may cause explosion and severe or fatal injury/ property damage. Drain condensed water from tank after each use to reduce rusting.
- Never weld on or repair tank—replace by authorized dealer.
| WARNING
| Risk of fire or explosion —Do not spray
a flammable liquid in a confined area or towards a hot surface.
- Spray area must be well ventilated.
- Do not smoke while spraying or spray where spark or flame is present. Keep compressors as far from spraying area as possible.
- Arching parts—Keep compressor at least 20 feet away from explosive vapors, such as when spraying with a spray gun.
| Risk of injury —Do not direct air stream at body.
- Disconnect power and drain all air pressure from tank before servicing and after each use.
- Do not used com- pressed air for breathing.
- Wear ANSI Z87 approved eye protection.
- Do not operate with supplied guards removed.
| RISK OF BURSTING
Prevent tank corrosion. After each usage,
drain all moisture from tank.
MOISTURE DRAIN
GLOSSARY
- CFM: Cubic feet per minute.
- SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
- PSI: Pounds per square inch; a unit of measure of pressure.
- Cut-in pressure: Factory set low pressure point that starts the compressor to repressurize the tank to a higher pressure.
- Cut-out pressure: Factory set high pressure point that stops the compressor from increasing the pressure in the tank above a certain level.
- Well-ventilated: A means of providing fresh air in exchange for dangerous exhaust or vapors.
- Dedicated circuit: An electrical circuit reserved for the exclusive use of the air compressor.
- ASME: American Society of Mechanical Engineers. Indicates that the components are manufactured, tested and inspected to the specifications set by ASME.
- CSA: Canadian Standards Association
Indicates that the products that have this marking have been manufactured, tested and inspected to standards that are set by CSA.
Canadian Standards Association (USA): Indicates that the products that have this marking have been manufactured, tested and inspected to standards that are set by CSA. These products also conform to U.L. standard 1450.
California Code: Unit may comply with California Code 462 (l) (2)/(M) (2). Specification/model label is on the side of the air tank on units that comply with California Code.
Troubleshooting Guide
This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance personnel can perform some corrective actions, and others may require the assistance of a qualified DEWALT technician or your dealer.
Problem Code
- Air leaks …………………………………………………………………………………………………………………….1
- Air leaks in air tank or at air tank welds………………………………………………………………………….2
- Air leaks between head and valve plate………………………………………………………………………….3
- Air leaks from safety valve…………………………………………………………………………………………….4
- Compressor is not supplying enough air to operate accessories……………………………………… 1, 5, 6, 7, 9, 10
- Restricted air intake……………………………………………………………………………………………………..9
- Oil in discharge air………………………………………………………………………………………………………. 9, 19, 31
- Knocking Noise………………………………………………………………………………………………………….. 4, 10, 11, 12, 13, 14
- Excessive belt wear…………………………………………………………………………………………………….. 10, 11, 14, 15
- Squealing sound………………………………………………………………………………………………………….10
- Moisture in pump crankcase………………………………………………………………………………………… 1, 3, 8, 17, 18, 19, 20, 21, 22
- Excessive current draw……………………………………………………………………………………………….. 14, 26, 27
- Compressor won’t start in cold temperatures………………………………………………………………… 17, 34, 35
- Pressure reading on the regulated pressure gauge drops when and accessory is used……….23
- Regulator knob has continuous air leak………………………………………………………………………….24
- Regulator will not shut off air outlet……………………………………………………………………………….24
- Air tank pressure will not build………………………………………………………………………………………25
- Compressor stalls……………………………………………………………………………………………………….. 28, 29, 30
- Overheating……………………………………………………………………………………………………………….. 27, 32, 33
CODE | POSSIBLE CAUSE | POSSIBLE SOLUTION |
---|---|---|
1 | Fittings are not tight | Tighten fittings where air can be heard escaping. |
Check fittings with soapy water solution. DO NOT OVERTIGHTEN.
2| Defective air tank| Air tank must be replaced. Do not repair the leak.
WARNING: Risk of bursting. Do not drill into, weld or otherwise modify air tank or it will weaken. The air tank can rupture or explode.
3| Leaking seals| Contact a DeWALT factory service center or a DeWALT
authorized service center.
4| Defective safety valve| Operate safety valve manually by pulling on ring.
If valve still leaks, it must be replaced.
5| Prolonged excessive use of air| Decrease amount of air usage.
6| Compressor is not large enough for accessory| Check the accessory air
requirement. If it is higher than the SCFM or pressure supplied by your air
compressor, a larger compressor is needed to operate accessory.
7| Hole in air hose| Check and replace air hose, if required.
8| Unit operating in damp or humid conditions| Move unit to a dry well
ventilated area.
9| Restricted air intake filter| Clean or replace air intake filter.
10| Loose belt| Check belt Maintenance.| tension,| see Adjusting Belt Tension|
under
11| Loose pulley| Tighten pulley set screw, torque to 85-90 in.-lbs. (9.6–10.2
Nm).
12| Loose flywheel| Tighten flywheel screw, torque to 14–18 ft.-lbs.
(20.0–24.4 Nm).
13| Carbon build-up in pump| Contact a DeWALT factory service center or a
DeWALT authorized service center.
14| Belt to tight| Check belt Maintenance.| tension,| see Adjusting Belt
Tension| under
15| Pulley misalignment| See Motor Pulley/Flywheel Alignment under
Maintenance.
16| Pump oil is low| Add full synthetic, non-detergent air compressor oil to
pump. See Compressor Pump Oil under Maintenance.
17| Detergent type oil being used in pump| Drain oil and refill pump with full
synthetic non-detergent air com- pressor oil.
18| Extremely light duty cycles| Run unit for longer duty cycles. It is
recommended to run at high throttle 50-75% of the run time and idle for 25% of
the run time.
19| Piston rings damaged or worn| Contact a DeWALT factory service center or a
DeWALT authorized service center.
20| Cylinder or piston damaged or worn| Contact a DeWALT factory service
center or a DeWALT authorized service center.
21| Compressor cylinder finish worn| Contact a DeWALT factory service center
or a DeWALT authorized service center.
22| Water in pump oil| Drain oil and refill pump with full synthetic non-
detergent air com- pressor oil.
23| Regulator is not adjusted correctly for accessory being used.| It is
normal for some pressure drop to occur when and accessory is used, adjust the
regulator as instructed in Regulator under Features if pressure drop is
excessive.
NOTE: Adjust the regulated pressure under flow conditions while the accessory is being used.
24| Damaged regulator| Replace
25| Regulator open| Rotate the regulator knob counter-clockwise to its built-
in stop.
26| Low voltage/motor overload| Check that power supply is adequate and that
compressor is on a dedicated circuit. If using extension cord, try using
without. If compressor is connected to a circuit protected by a fuse, use dual
element time delay fuses (Buss Fusetron type “T” only).
27| Restricted air passages| Inspect and replace transfer tubes or check
valve, as required.
28| Low voltage motor| Furnish adequate powder.
29| Bad check valve| Replace check valve.
30| Seized pump| Contact a DeWALT factory service center or a DeWALT
authorized service center.
31| Oil level too high| Reduce to proper level. See Compressor Pump Oil under
Maintenance.
32| Poor ventilation| Relocate compressor to an area with cool, dry, well
circulated air, at least 12 in. from nearest wall.
33| Dirty cooling surfaces| Clean all cooling surfaces thoroughly.
34| Too much back pressure in tank.| Open drain valve when starting motor.
35| Compressor too cold| Move compressor to a warmer location.
For product, service or warranty information contact us at:
Tel: 1-888-895-4549
Website: www.DEWALT.com
MAT Industries, LLC, Long Grove, IL 60047
Under license from DEWALT Industrial Tool Co.
Bojo licencia de DEWALT Industrial Tool Co.
Sous licence de DEWALT Industrial Tool Co.
The following are trademarks for one or more DEWALT power tools: thee yellow and black color scheme; the “D” shaped air intake grill; the array of pyramids on the handgrip; the kit box configuration; and the array of lozenge shape humps on the surface of the tool.
References
- DEWALT® Power Tools Official Site | Guaranteed Tough®
- DEWALT® Power Tools Official Site | Guaranteed Tough®
- P65Warnings.ca.gov
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>