MPS EVKT-8847 MP8847 Evaluation Kit User Guide
- June 11, 2024
- MPS
Table of Contents
MPS EVKT-8847 MP8847 Evaluation Kit
Overview
Introduction
The EVKT-8847 is an evaluation kit for MP8847.The MP8847 is a highly
integrated, high-frequency, synchronous, step-down switcher with an I2C
control interface. The MP8847 can support up to 6A of current from a wide
2.7Vto 6V range with excellent load and line regulation. This kit allows for
quick evaluation of the MP8847. By using the I2C, users can set the switching
frequency, slew rate, work mode, and the output voltage.
Kit Content
EVKT-8847 kit contents: (items below can be ordered separately).
# | Part Number | Item | Quantity |
---|---|---|---|
1 | EV8847-D-00A | MP8847GD evaluation board | 1 |
2 | EVKT-USBI2C-02 | Includes one USB to I2C communication interface, one USB | |
cable, one ribbon cable | 1 | ||
--- | --- | --- | --- |
Features and Benefits
The MP8847 is highly customizable. Users can program the IC via the MPS I2C
GUI.
⚠️ All changes made in I2C mode will NOT be retained once the EVB is powered
down.
Features adjustable under each method are outlined below.
I2C
- Selectable the output voltage
- Selectable transition response
- Selectable slew rate
- Selectable switching frequency
- Selectable output discharge
- Selectable VIN_OVP
- Selectable PG function
- Selectable mode (PFM & CCM)
- System enable
- Status indication: ILIM, UVLO, VIN & Vout OVP, Vout UVP, PG, OTW
Kit Specifications
Feature
Specification
Supply for Board
2.7V – 6V
Operating Input Voltage 2.7V – 6V
Operating Systems Supported Windows XP, 7,
and later
System Requirements Minimum
22.2MB free
GUI Software 3
Register Controls: VSEL, System 1, System 2
EVB Size (L x W) 6.3
cm x 6.3 cm
Section 1. Hardware Specifications
Personal Computer Requirements
The following must be minimally met to use the EVKT-8847.
- Operating System of Windows XP, 7, or later
- Net Framework 4.0
- PC with a minimum of one available USB port
- At least 22.2 MB of free space
EV8847-D-00A Specifications
The EV8847-D-00A is an evaluation board for the MP8847GD. For more
information, please refer to the EV8847-D-00Adatasheet.
Feature Specification
Supply for Board 2.7V – 6V
Operating Input Voltage 2.7V – 6V
EVB Size (L x W) 6.3 cm x 6.3 cm
EVKT-USBI2C-02 Specifications
The EVKT-USBI2C-02 refers to the communication interface, which connects the
EVB, the PC, and its supporting accessories. It provides I2C and PMBus
capabilities. Together with MPS Virtual Bench Pro and GUI tools, it provides a
quick and easy way to evaluate the performance of MPS digital products. For
more details, refer to the EVKT-USBI2C-02 datasheet.
Section 2. Software Requirements
Software Installation Procedure
Programming occurs through the MPS I2C GUI. Follow the instructions below to
install the software.
Note : This software can be downloaded directly from the MPS website.
- Visit the MP88xx I2C GUI page at https://www.monolithicpower.com/en/i2c-tool.html
- Click the “Download” button in the upper right-hand corner.
- Once the download has completed, double-click the .exe file to open the set-up guide (see Figure 4).If a protection window comes up, click “More info,” then click “Run anyway.”
- Follow the prompts in the set-up guide.
- Wait for status screen to verify that installation is complete (see Figure 5).
Section 3. Evaluation Kit Test Set-Up
Hardware Set-Up
The hardware must be properly configured prior to use. Use the USB cable to
connect the EVKT-USBI2C- 02 communication interface to the PC, and follow the
instructions below to set up the EVB.
- Locate the proper wires to connect the EVB to the EVKT-USBI2C-02 communication interface.
- Connect SCL, SDA, and GND (see Figure 6). If needed, refer to the datasheet for further clarification.
Powering up the EVB
- Connect the positive and negative terminals of the load to the VOUT and GND pins, respectively.
- Preset the power supply output to between 2.7V and 6V, and then turn off the power supply.
- Connect the positive and negative terminals of the power supply output to the VIN and GND pins, respectively.
- Turn the power supply on and make the EN voltage more than the threshold. The IC will enter the power-on sequence automatically.
Software Set-Up
After connecting the hardware according to the steps above, follow the steps
below to use the GUI software.
- Start the software. It will automatically check the EVB connection.
- If connection is successful, the address will be listed in the “Slave Address” (see Figure 7).
- If the connection is not successful, a warning will appear at the bottom. There are two warnings a user can expect (see Figure 8). Each of the warnings mean an invalid connection.
- “EVB is Disconnected!” This means that the evaluation board is not connected.
- “Communication Board is Disconnected!” This means that the USB I2C communication interface is not connected.
- If connection is successful, proceed to Step 3. Otherwise, check connections between the EVB, communication interface, and PC. Re-plug the USB into the computer and restart the GUI.
- Click the PartSelect button to select the MP8867 (see Figure 7) (The default GUI window is for the MP8861). The Register Control menu will appear on the left side. The I2C register values will be read and displayed on the right side after clicking the Read button (see Figure 9).
- Find the item you want to change and select the desired value from the drop-down menu.
- Click the Read button to update the values. The changed information of the item will appear on the right side (see Figure 10).
Troubleshooting Tips
Note : USBI2C-02 and USBI2C-01 drivers are not compatible. USBI2C-02 uses
USBXpress and USBI2C- 01 uses Cyusb3. USBI2C-02 is the recommended device for
the MPS PMBus and I2C.
EVKT-USBI2C-01
In case the USBI2C-01 driver is not properly installed, manual installation is
required. Follow the steps below:
- Open the Device Manager and select update driver software (see Figure 11).
- Click “Browse my computer for driver software.”
EVKT-USBI2C-02
In case the USBI2C-02 driver is not properly installed, manual installation is
required. Follow the steps below:
Note: Check driver version. Find “USBXpress” Device in the Device Manager
under USB controllers.
Right click and view properties. Check to make sure the driver version matches the newest version (see Figure 12).
-
Install the correct USBXpress “.exe” file.
Choose either the 32 bit or 64 bit operating system:
32-bit: USBXpressInstaller_x86.exe
64-bit: USBXpressInstaller_x64.exe -
Connect the EVKT-USBI2C-02 communication interface to the PC with the USB cable.
No Supply
The MP8847’s input pin has an under-voltage lockout (UVLO) detection
circuit. If the input voltage (AVIN) is lower than the UVLO rising threshold,
the MP8847’s functions are disabled.
Shutdown Event
If the MP8847 detects that the input voltage is lower than the UVLO falling
threshold (it enters a no supply state) or over-temperature protection is
triggered (it enters a power-off state), the MP8847 switches to no supply
state or power-off state, regardless of the current state.
Thermal Recovery
If the MP8847 is in a power-off state due to the die temperature exceeding
the thermal protection threshold, the MP8847 enters a power-on sequence when
the die’s temperature decreases.
Shutdown Sequence
When the input voltage is lower than the UVLO falling threshold, or the IC
is over-temperature, the MP8847 enters the shutdown sequence directly.
Section 4. Ordering Information
The components of the evaluation kit can be purchased separately depending on user needs.
Order directly from MonolithicPower.com or our distributors.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>