Mps Energy EDS-E1 Controller Motor Meter User Manual
- June 3, 2024
- Mps Energy
Table of Contents
Mps Energy EDS-E1 Controller Motor Meter
Website: https://www.mpsenergy.com.tw/
Visit us:
Specification
Input Voltage | 24 ~ 60 V |
---|---|
Communication Interface | UART for controller BLE for app |
Display | LED |
Key | Power / + / – button |
Operating Temperature | -20°C ~ 60°C |
IP | IP65 |
Certifications | ISO 13849-1 2015 certification |
Operation
How to power on HMI
Long press “Power key” for 3 seconds to power on the HMI. After powering up the HMI, you will see all indicator lights turned on as the following figure.
How to power off
During HMI at power on state, you can long press “power key” for 3 seconds to power off the HMI.
LED Lights information
You can check the current status using the LED lights information. There are 7 LED lights on the HMI, their positions are labeled with number ① ~ ⑦ as the following figure.
Battery Indication
You can check the battery level to know the current battery capacity as the
following figure. LED ④, ⑤ and ⑥ represent battery levels in normal mode.
Assist levels
Short press UP / DOWN key to switch the assist level. Top level is 3, 0 for
neutral. LED ①, ②, and ③ represent assist levels in normal mode.
Walk mode
Keep pressing the DOWN key to enter the Walk mode. The speed limit for Walk
mode is 6km/h.
Release the DOWN key to return back to the assist mode.
Headlight ON/OFF
Long press the UP key for 1 second. Once the headlight icon is displayed on
the screen, the headlight is ON. To turn OFF, press the UP key for 1 second.
Bike status monitoring
The blinking LED ①, ②, and ③ represent different bike status, it can assist
user to check the status of the E-bike.
For status like:
Speed is over Speed Limit
Brake status
Temperature is above the limited value on the controller
If any of these status happens, the controller shall stop the motor output
immediately.
Controller status monitoring
The combination of blinking LEDs (① ~ ⑥) represent different controller
status. These status can assist user to check the state of the controller.
If any of below status happens:
- OC (Over Current)
- OT (Over Temperature)
- OV (Over Voltage)
- UV (Under Voltage) Software Error
The controller shall stop the motor output immediately.
Connection problem
If there is any connection problem between the controller and the HMI, a timeout status will be showed by LED ①, ②, ④ and ⑤ will blink.
Please try to switch the HMI and battery off first, and check if the cables are well connected and then switch on HMI again. If the problem persists, please contact the manufacturer for assistance.
BLE connection
When the APP establishes a BLE connection with the HMI, on HMI it shall start the BLE pin code mode, LED ⑦ will start blinking. LED ① ~ ⑥ will remain the same as normal mode.
In this state, user can long press the UP and DOWN keys simultaneously for 2
seconds to reset the BLE pin code to the default code (0000).
After user input the BLE pin code on the APP and the pin code is correct, the
HMI shall return to normal mode. LED ⑦ will continue turned on to indicate
that the BLE connection is established. Please check the following two
examples:
Update Mode
When power user updating the parameter or firmware version of the controller, the display will enter the update mode. LED ②, ⑤ and ⑦ will remain on until the update is completed. Normal user will not see this mode.