LEDone LOC-PT Multi-Watt Multi-Color Post Top LED Installation Guide
- June 4, 2024
- LEDone
Table of Contents
LOC-PT Multi-Watt Multi-Color Post Top LED
Installation Guide
SAFETY INSTRUCTIONS:
Read the instructions carefully before attempting to install the fixture.
- All wiring should be performed by a qualified electrician.
- Disconnect power before installing or servicing. This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances.
- Proper grounding is required to ensure personal safety.
- This fixture is for outdoor use and should not be used in areas with limited ventilation or high ambient temperatures.
CAUTION: Risk of fire
- WARNING: Make certain power is OFF before installing or maintaining the fixture. No user-serviceable parts inside.
CLEANING & MAINTENANCE:
CAUTION: Be sure the fixture temperature is cool enough to touch. Do NOT clean or maintain while the fixture is energized.
- Clean glass lens with non-abrasive cleaning solution.
- Do NOT open the fixture to clean the LED. Do NOT touch the LED.
Note: These instructions do not cover all details or variations in equipment, nor do they provide for every possible situation during installation, operation, or maintenance.
TROUBLESHOOTING:
- Check that the line voltage at the fixture is correct. Refer to wiring directions.
- Check that the fixture is grounded properly.
POLE MOUNTING:
- Make the wiring connections with UL-approved connectors. Knot the wires for strain relief.
- Tenon pole adaptor can fit tenon with 3” or 2 3/8” diameter. Slip the tenon pole adaptor over the tenon and secure the fixture to the tenon.
a. For 3” tenon, use the shorter (3/8”) tenon set screw.
b. For the 2 3/8” tenon, use the longer (7/8”) tenon set screws.
INSTALLATION:
- Feed the (3) housing wires through one of the three rods.
- Screw the top of (3) rods into the housing. Be sure the housing clips are properly engaged onto the rods.
- Feed fixture wires through the tenon pole adaptor.
- Slide tenon pole adaptor on the 3 rods. Be sure the notches face the inside of the tenon pole adaptor.
- Put the rubber mat onto the adaptor.
- Tighten the (3) set screws at the tenon pole adaptor to secure rods.
WIRING:
Universal voltage driver permits operation at 100V through 277V, 50/60Hz
except for fixtures that the factory ordered with a 120V photocell (/PC).
- Connect the BLACK fixture lead to the (+) LIVE line supply wire.
- Connect the WHITE fixture line to the NEUTRAL line supply wire.
- Connect the GREEN fixture line to the supply ground.
0-10V DIMMABLE WIRING:
Universal voltage driver permits operation at 120V through 277V, 50/60Hz. For
0-10V dimming, follow the wiring instructions in the figure below.
- Connect the BLACK fixture lead to the (+) LINE supply lead.
- Connect the WHITE fixture lead to the (-) COMMON supply lead.
- Connect the GROUND wire from the fixture to the supply ground. DO NOT connect the GROUND of the dimming fixture to the output.
- Connect the PURPLE fixture lead to the (V+) DIM lead.
- Connect the GRAY fixture lead to the (V-) DIM lead.
- The driver comes with dimmable leads. If it is unused, make sure the leads are properly capped (if applicable).
WATTAGE AND CCT ADJUSTABLE TABLE SWITCH SETTING:
LOC-PT-MW(60/80/100/150)MCCT(30/40/50)DLV
Default Wattage: 150W
Default CCT: 5,000K
Wattage Options | CCT Options |
---|---|
60W | 3,000K |
80W | 4,000K |
100W | 5,000K |
150W |
Phone: (844) LEDONE6
Fax: 1-510-217-9461
Web: www.ledonecorp.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>