Product Information

The product is a lighting fixture that requires installation and electrical connection. It is important to follow all safety instructions to avoid electric shock, injury, and fire hazards. The product is manufactured by Acuity Brands Lighting, Inc. and falls under their brands that include Lithonia Lighting, Gotham, American Electric Lighting, Dark To Light, Carandini, Mark Architectural Lighting, Antique Street Lamps, Lighting Control & Design, Holophane, Peerless, Hydrel, ROAM, Reloc, Renaissance Lighting, Tersen, Sensor Switch, Winona Lighting, and Synergy.

Important Safety Instructions

  • Read and follow all safety instructions.
  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with theluminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.
  • Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
  • Do not exceed maximum wattage marked on luminaire label.
  • Follow all lamp manufacturer’s warnings, recommendations and restrictions on lamp operation including but not limited to: ballast type, burning position, replacement, and recycling.
  • Use only lamps that comply with ANSI standards.
  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.
  • Keep combustible and other materials that can burn, away from lamp/lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
  • Failure to follow any of these instructions could void product warranties.

Product Usage Instructions

  1. Before installation, read and follow all safety instructions.
  2. Disconnect or turn off power before installation or servicing.
  3. Verify that supply voltage is correct by comparing it with the luminaire label information.
  4. Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements. All wiring connections should be capped with UL approved recognized wire connectors.
  5. Allow lamp/fixture to cool before handling. Do not touch the enclosure or light source.
  6. Install the lighting fixture according to the manufacturer’s instructions and applicable codes.
  7. Do not exceed the maximum wattage marked on the luminaire label.
  8. Use only lamps that comply with ANSI standards. Follow all lamp manufacturer’s warnings, recommendations and restrictions on lamp operation including but not limited to: ballast type, burning position, replacement, and recycling.
  9. Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance. Avoid direct eye exposure to the light source while it is on.
  10. Keep combustible and other materials that can burn, away from lamp/lens. Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
  11. To mate and un-mate photocell to the receptacle, align photocell blades with receptacle power contact circuits. Note that the neutral photocell blade is larger than the line and load blades, providing mating polarization. After properly aligning the blades to the receptacle power contact circuits, push downward until the photocell is bottomed on the receptacle’s mating surface, slightly compressing the gasket of the photocell. Then complete mating by twisting the photocell in a clockwise direction. The photocell will lock into position.

SAFETY INSTRUCTIONS

IMPORTANT

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazardsplease read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazardsinvolved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level andminimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasivehousehold detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens andclean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit.Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • If the lamp is marked (Hg) it contains Mercury. Follow all disposal laws. See www.lamprecycle.org.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in

WARNING:RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with theluminaire label information.
  • Make all electrical and grounded connections in accordance withthe National Electrical Code (NEC) and any applicable local coderequirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.

CAUTION: RISK OF INJURY

  •  Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  •  Avoid direct eye exposure to the light source while it is on.

WARNING: RISK OF BURN

  •  Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
  •  Do not exceed maximum wattage marked on luminaire label.
  •  Follow all lamp manufacturer’s warnings, recommendations and restrictions on lamp operation including but not limited to: ballast type, burning position, replacement, and recycling.
  •  Use only lamps that comply with ANSI standards.

CAUTION: RISK OF FIRE

  •  Keep combustible and other materials that can burn, away from lamp/lens.
  •  Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands :

  • Indoor/Outdoor Lithonia Lighting Carandini Holophane Reloc
  • Indoor Lighting Gotham Peerless Renaissanc Lighe ting Winona Lighting
  • Outdoor Lighting Amer Elecican tr Lighic ting Mar Ark chitectur Lighal ting An Stique treet Lamps Hydrel Tersen
  • Controls Dar Tk Light Lighting Control & Design ROAM S Sensor witch Synergy

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 © 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

Installation Instructions

Instructions for Rotatable Dimming Receptacles Figure shows the parts that make up the receptacle. The dimming contact pads are lubricated with an electrical lu-bricant and personal contact with these pads should be avoided .AcuityBrands-Rotatable-Dimming-Receptacles-fig-1

Once the light fixture is installed in the field, it is easy to rotate the receptacle so the North indicator is aimed properly. Loosen the mounting screws just enough so the center receptacle housing rotates freely in the locking ring. Use a screwdriver to aim the center receptacle housing so the North indicator points in the desired direction (typically due North). The rotatable dim-ming receptacle is designed to limit the total rotation to 355 degrees with a stop feature. If the desired direction can’t be achieved by turning clockwise due to the stop feature, simply turn the center receptacle housing counter-clockwise to the desired position. Once the desired aiming is achieved, the mounting screws can be tightened to the recommended 15 inch pounds of torque. See the below Figure 3.

AcuityBrands-Rotatable-Dimming-Receptacles-fig-2

Instruction for mating and un-mating photocell to receptacle (Figure 4):
Align photocell blades with receptacle power contact circuits. Note that the neutral photocell blade is larger than the line and load blades, providing mating polarization. After properly aligning the blades to the receptacle power contact circuits, push downward until the photocell is bottomed on the receptacle’s mating surface, slightly compressing gasket of the photocell. Then complete mating by twisting the photocell in a clockwise direction. The photocell will lock into position.

To un-mate, reverse the above process steps.AcuityBrands-Rotatable-Dimming-
Receptacles-fig-3