Wiring Instructions

Power Off
Before commencing work always isolate the power at the consumer unit / fuse box. Note – If your installation uses a four-lug metal mounting box, remove the top and bottom lugs or bend fully back.

Installation

  1. Install mounting box (metal or moulded) for either flush or surface mounting, ensuring appropriate size of product IMounting box to be purchased separately).
  2. Select the most suitable entry point of the mounting box (knock-out) and route the cables through. If a metal box is used, a cable grommet should be fitted to the entry point.
  3. Cables should be prepared so a sufficient conductor length reaches the terminals. Strip the ends of the individual conductors leaving an adequate length bare to enter terminals.

Connection (See diagram)

  1. Line up the new accessory to mounting box and take note of where each terminal is located.
  2. Connect each wire to the matching terminal. An earth connection should always be made between the mounting box earth terminal and the accessory earth terminal, where fitted. All bare earth wires must be sheathed with green/yellow sleeving. When connecting the new accessory ensure that only the bare end of the wire enters the terminal and no bare wires are visible.
  3. Tighten terminal screws securely. IDo not over tighten)

Complete Installation & Test

  1. Carefully position the accessory into the mounting box, ensuring that no wires are trapped between the plate and the wall and secure with screws Ido not over tighten) then insert screw covers (optional).
  2. Once the installation has been completed correctly, replace the fuse/ reset MCB (trip), switch the power back on at the consumer unit and test.

Fan Isolator – 3 Pole Switch with Fuse Module
During repair or installation or routine maintenance the power supply to the _ fan unit must be disconnected.This isolating switch can be installed as shown in the diagrams to enable the remainder of the circuit to remain live. This unit is supplied with a Fuse module to allow the feed to the Fan to be fused as required by the manufacturer, please check the fuse rating meets their requirements.A wire is required to link the relevant terminal on the output side of the Fan Isolator Switch to the input of the Fuse module, as shown in the wiring diagrams. These instructions should be read in conjunction with the instructions supplied with the fan unit and the latest IET Wiring Regulations. Please follow the appropriate wiring diagram for your particular installation.
Important
The continuity of the protective conductors must be maintained . The isolator switch shall be so situated as to be inaccessible to a person using a fixed bath or shower.

Safety Warning

For your safety, this product must be installed in accordance with local Building Regulations. If in any doubt, or where required by the law, con-sult a competent person who is registered with an electrical self-certifi-cation scheme. Further information is available online or from your Local Authority. Please read carefully and use in accordance with these safety wiring instructions. Before commencing any electrical work ensure the supply is switched off at the mains. Either by switching off the consumer unit or by removing the appropriate fuse or turning off MCB (trip). Wiring should be in accordance with the latest edition of the IET regulations (BS 7671). To prevent fire hazard always use cable of the correct rating & type for the application.
Warning do not exceed the load rating of this device as stated on the rear of the product.
Wire Identification – Twin & Earth Cable
Note – As from 1st April 2004 new colour codes for hard wire installations were introduced.
EARTH = Green/Yellow Sleeving .S■4-1E
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04) 1–1 N E
LIVE = Red (pre Apr 04) / Brown (after Apr 04)

Instruction
Instruction
Instruction
Instruction

Care

To maintain the high quality appearance of decorative finish switches and sockets, BG Electrical recommend the use of a soft cloth periodically to clean the front face. When installing a decorative product please ensure that the wall is decorated, finished and free of moisture prior to installa-tion. BG Electrical recommends avoiding using, but not restricted to, these substances from becoming in contact with the decorative metal front-plates when cleaning or decorating:

  • Adhesive tape, including low tack masking tape
  • Solvents
  • White spirit
  • Multi surface cleaners
  • Industrial multipurpose cleaning wipes
  • Wet wipes

Using items like those listed above may cause a degrading effect to the front- plates lacquer/plated finish, although the function will remain unaffected.

Additional Advice for Decorative Products

Fixing method varies depending on which product range is supplied. Always ensure wall surface is reasonably flat and smooth, with no bumps or projections. Metal frontplates WITH screw fixing holes, fix the unit to the back box using two fixing screws supplied. All Decorative products MUST have an earth connection between the frontplate and back box. Frontplates WITHOUT screw fixing holes. These products comprise main unit with integral gasket, and frontplate as separate item. Fix unit to back box using two fixing screws supplied. Clip frontplate onto main assembly, ensuring screwdriver notch is located bottom right hand corner. To remove plate, place medium size flat bladed screwdriver in notch and lever off against gasket.

Batch Code explanation

yyWxx Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)

Address/Helpline

Luceco PLC Stafford Park 1 Telford TF3 3BD ENGLAND
(EU) Luceco SE C/ Bobinadora 1-5 08302 Matar6 SPAIN

If you have further technical assistance you can get in touch with our Technical Helpline on: +44 [0)3300 249 279 technical.supportfabgetectrical.co.uk

Technical

Voltage : 220-240V ac
Frequency : 50/60Hz
Rating : Switch – 10A Rated, Fuse module fitted with 3A fuse (B51362)
Terminal capacity : 4 x 1mm2 4 x 1.5mm2 2 x 2.5mm2 1 x 4mm2
Min box depth [profiled plates) : 25mm Min box depth (flat plates) : 25mm

Environmental Protection

 This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/ electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/ battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BG Electrical User Manuals

Related Manuals