BG ELECTRICAL PM12W Part M Grey Moulded 1 Gang 2 Way Plateswitch Instruction Manual
- June 11, 2024
- BG Electrical
Table of Contents
Wiring Accessories
Plate Switch
Wiring Instructions
- Power Off
Before commencing work always isolate the power at the consumer unit/fuse box.
*Note – If your installation uses a four-lug metal mounting box, remove the top and bottom lugs or bend fully back.
2a. Replacing an existing accessory
-
Unscrew the accessory from the wall/mounting box.
-
Note the cable connections:
The illustration shows 1 wire of each colour connected to each terminal.
There should be an additional connection between the mounting box earth terminal and the accessory earth terminal. -
Unscrew each terminal to release the wire.
2b. New installation
- Install mounting box (metal or moulded) for either flush or surface mounting, ensuring appropriate size of product (Mounting box to be purchased separately).
- Select the most suitable entry point of the mounting box (knock-out) and route the cables through. If a metal box is used, a cable grommet should be fitted to the entry point.
- Cables should be prepared so a sufficient conductor length reaches the terminals. Strip the ends of the individual conductors leaving an adequate length bare to enter terminals.
Connection (See diagram)
- Line up the new accessory to mounting box and take note of where each terminal is located.
- Connect each wire to the matching terminal.
An earth connection should always be made between the mounting box earth
terminal and the accessory earth terminal, where fitted.
All bare earth wires must be sheathed with green/yellow sleeving. When
connecting the new accessory ensure that only the bare end of the wire enters
the terminal and no bare wires are visible.
Tighten terminal screws securely. (Do not over tighten)
SWITCHED LIVE
Complete Installation & Test
- Carefully position the accessory into the mounting box, ensuring that no wires are trapped between the plate and the wall and secure with screws (do not over tighten) then insert screw covers (optional).
- Once the installation has been completed correctly, replace the fuse/reset MCB (trip), switch the power back on at the consumer unit and test.
Switch types
One Way Switching
One way switching is used in installations that require just one switch to
control a light (or circuit) i.e. on or off.
A two-way switch can be used for one way connection, use COM and L1 terminals.
For multiple gang switches (2, 3, 5 & 6) repeat.
Two Way Switching
Two way switching is used where a light is controlled by two switches.
For multiple gang switches (2, 3, 5 & 6) repeat.
Bell Push
The bell push is a one way switch with a retractive rocker switch.
Before installing, ensure the bell unit is suitable for supply voltage.
Intermediate Switching
Intermediate switching is used in installations that require three or more
switches to control a light, and should be used together with two 2-way
switches.
Additional Advice for Decorative Products
Fixing method varies depending on which product range is supplied. Always
ensure wall surface is reasonably flat and smooth, with no bumps or
projections. Metal frontplates WITH screw fixing holes, fix the unit to the
back box using two fixing screws supplied. All Decorative products MUST have an
earth connection between the frontplate and back box. Frontplates WITHOUT
screw fixing holes. These products comprise main unit with integral gasket, and
frontplate as separate item. Fix unit to back box using two fixing screws
supplied. Clip frontplate onto main assembly, ensuring screwdriver notch is
located bottom right hand corner.
To remove plate, place medium size flat bladed screwdriver in notch and lever
off against gasket.
Care
To maintain the high quality appearance of decorative finish switches and
sockets, BG Electrical recommend the use of a soft cloth periodically to clean
the front face. When installing a decorative product please ensure that the
wall is decorated, finished and free of moisture prior to installation.
BG Electrical recommends avoiding using, but not restricted to, these
substances from becoming in contact with the decorative metal front-plates
when cleaning or decorating:
- Adhesive tape, including low tack masking tape
- Solvents
- White spirit
- Multi surface cleaners
- Industrial multipurpose cleaning wipes
- Wet wipes
Using items like those listed above may cause a degrading effect to the front- plates lacquer/plated finish, although the function will remain unaffected.
Safety Warning
For your safety, this product must be installed in accordance with local
Building Regulations. If in any doubt, or where required by the law, consult a
competent person who is registered with an electrical self-certification
scheme. Further information is available online or from your Local Authority.
Please read carefully and use in accordance with these safety wiring
instructions. Before commencing any electrical work ensure the supply is
switched off at the mains. Either by switching off the consumer unit or by
removing the appropriate fuse or turning off MCB (trip). Wiring should be in
accordance with the latest edition of the IET regulations (BS 7671).
To prevent fire hazard always use cable of the correct rating & type for the
application.
Warning do not exceed the load rating of this device as stated on the rear of
the product.
Wire Identification – Twin & Earth Cable
Note – As from 1st April 2004 new colour codes for hard wire installations
were introduced.
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
One Way Switching
Two Way Switching
Bell Push
Intermediate switching
Fan Isolator – 3 Pole Switch
During repair or installation or routine maintenance the power supply to the
fan unit must be disconnected.
This isolating switch can be installed as shown in the diagrams to enable the
remainder of the circuit to remain live.
These instructions should be read in conjunction with the instructions
supplied with the fan unit and the latest IET Wiring Regulations.
Please follow the appropriate wiring diagram for your particular installation.
Important
The continuity of the protective conductors must be maintained .
The isolator switch shall be so situated as to be inaccessible to a person
using a fixed bath or shower.
Fan Isolator switching
Technical
Voltage : 220-250V~
Frequency : 50/60Hz
Rating : 20A 16AX
SBL Rating : 250W
Rating (Fan Isolator) : 10A 3 Pole
Rating (Bell Push) : 10A
Terminal capacity : 4 x 1mm² 4 x 1.5mm² 2 x 2.5mm² 1 x 4mm² 1 x 6mm²
Min box depth (profiled plates) : 1 & 2 gang switches 16mm Fan, 3, 4 & 6 gang
switches 25mm
Min box depth (flat plates) : 25mm
ASTA Approved
The ASTA quality mark is evidence that the product has been independently
tested to comply with the relevant clauses of the applicable standards.
Batch Code Explanation
yyWxx Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)
Address/Helpline
Luceco PLC
Stafford Park 1
Telford TF3 3BD
ENGLAND| (EU) Luceco SE
C/ Bobinadora 1-5
08302 Mataró
SPAIN
---|---
If you have further technical assistance you can get in touch with our
Technical Helpline on:
+44 (0)3300 249 279
technical.support@bgelectrical.co.uk
Environmental Protection
This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.