Before commencing work always isolate the power at the consumer unit/fuse box.
-
The unit should be mounted on a clean, rigid vertical surface suitable to accept screw type fixings. Surface should be reasonably flat as unevenness could cause product damage or affect operation.
-
Remove Front assembly from Rear Box.
-
For cable entry, decide if conduit is being used & entry positions.
For side, top or rear entry the lowermost drain hole position MUST be drilled out using a 5mm drill. ONLY ONE drain hole position must be drilled.
For bottom entry a drain hole MUST NOT be drilled in Rear Box, but a drain hole MUST be drilled at lowermost point of conduit run.
For rear entry, drill/cut the appropriate size hole. For extra sealing protection, a channel around knock-out is provided to accept a bead of sealant (not supplied) when fixing to mounting surface.
Note – The drilling of the drain hole or removing a knock-out will reduce the IP rating of the product. -
Mount the Rear Box using No.8 screws in all four, or at least two diagonal positions on fixing centres shown. The fixing holes are slotted to enable some rotation adjustment if required. Fit supplied Bungs over all used fixing screw positions to seal aperture recesses.
-
Make cable entry into rear box as required. Only remove the blanking plugs for positions used. Ensure adequate excess lengths of cable for connection to switch (s). Install & seal all cable glands & conduit to Manufacturer’s instructions.
To install, remove the blanking plug from rear box, and fit gland or conduit.
Ensure the gland or conduit and cable entry are sealed with a non-setting sealant. -
Offer up Front Assembly to Rear Box to determine final lengths of cables & cut to suit. Strip outer insulation as required & then trim insulation on individual wires 8- 10mm to expose conductor ends.
-
Refer to Wiring Diagrams for connection advice.
-
Tighten terminal screws securely (Do not over tighten).
-
Any earth connections MUST be made & continuity maintained. All bare earth wires must be sheathed with green/yellow sleeving.
-
After wiring Switch, refit Front Assembly to Rear Box, secure using the fixing screws provided (Do not overtighten)
-
Once the installation has been completed correctly, replace the fuse/reset MCB (trip), switch the power back on at the consumer unit and test.
Safety Warning
For your safety, this product must be installed in accordance with local
Building Regulations. If in any doubt, or where required by the law, consult a
competent person who is registered with an electrical self-certification
scheme.
Further information is available online or from your Local Authority.
Please read carefully and use in accordance with these safety wiring
instructions.
Before commencing any electrical work ensure the supply is switched off at the
mains. Either by switching off the consumer unit or by removing the
appropriate fuse or turning off MCB (trip). Wiring should be in accordance
with the latest edition of the IET regulations (BS 7671).
To prevent fire hazard always use cable of the correct rating & type for the
application.
Warning do not exceed the load rating of this device as stated on the rear of
the product.
Note – As from 1st April 2004 new colour codes for hard wire installations
were introduced.
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
If installed correctly BG Electrical Weatherproof products provide an IP66
level of protection, this means that the sealed construction provides a very
high level of protection against the ingress of both water & dust.
Safety Instructions
Please read carefully before installation.
- An outdoor location should be chosen ensuring adequate access to a mains supply circuit. The circuit MUST be protected by an appropriate fuse, circuit breaker or RCD (Residual Current Device) in accordance with current IET wiring regulations.
- Where conduit is used for cable runs, water condensation MUST be prevented from collecting inside the unit & conduit. Drain holes MUST be drilled out (see Installation Instructions)
- If metal conduit is used, earth continuity across the conduit must be maintained using appropriate connections (not supplied). An earth terminal in the Rear Box is provided as required.
- Where outdoor cable runs occur, ensure cable recommended for outdoor installations is used. In general, rubber insulated cable & plastic M20 cable glands can be used. Alternatively standard flat PVC twin & earth mains cable inside 20mm plastic or metal conduit may be used. Where necessary, SWA (Steel Wire Armoured) cable with metal cable glands should be used.
The outdoor use of unprotected flat PVC insulated cable is NOT recommended.
Wiring Connections
NOTE
The colours of the wires will be dependent on the type of cable used.
See wire identification section for reference.
One Way Switch – WPL12
One way switching is used in installations that require just one switch to
control a light (or circuit) i.e. on or off.
A two way switch can be used for one way connection use COM and L1 terminals.
For single pole one way switching, wire the module as follows:
Connect the Live wire to COM terminal
Connect SWITCHED LIVE wire to L1 terminal
Two Way Switch – WPL42
Two way switching is used where a light is controlled by two switches.
For two way switching using this switch and another remote switch, wire the
module as follows:
On one switch:
Connect the Live wire to COM terminal
Connect SWITCHED LIVE wire to 1 WAY terminal
On remote switch, using 3 core cable between switches:
Connect wire core 1 between COM terminals
Connect wire core 2 between L1 terminals
Connect wire core 3 between L2 terminals
Indicator Wiring
The unit has an Indicator pre-wired between the COM terminal & terminal block, with a link wire to 1 WAY terminal. The Indicator can be wired in one of three ways depending on presence of Neutral supply.
- Power Mode: LED ALWAYS ON when POWER is ON.
- Switch Mode: LED ONLY ON when switch is ON.
- Locator Mode: LED ONLY ON when switch is OFF.
If Neutral supply wire is present, the LED Indicator can be wired in Power or Switch Mode (or Locator Mode if required).
Care
This decorative BG Weatherproof accessory has a Stainless Steel finish, and
over time environmental conditions/weathering may affect the finish of this
product, especially in coastal regions.
During the life of the product any cleaning should be carried out with a damp
cloth using a mild detergent & warm water. DO NOT USE solvent based cleaners
as these may cause damage.
Technical
Voltage : 250V ac
Frequency : 50/60Hz
Switch Rating : 20AX
SBL Rating : 250W
Terminal Capacity : 4 x 1.5mm², 2 x 2.5mm², 1 x 4mm², 1 x 6mm²
IP Rating : IP66
ASTA Approved
The ASTA quality mark is evidence that the product has been independently
tested to comply with the relevant clauses of the pplicable standards.
Batch Code Explanation
yyWxx Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)
Address/Helpline
Luceco PLC | (EU) Luceco SE |
---|---|
Stafford Park 1 | C/ Bobinadora 1-5 |
Telford TF3 3BD | 08302 Mataró |
ENGLAND | SPAIN |
If you have further technical assistance you can get in touch with our
Technical Helpline on:
+44 (0)3300 249 279
technical.support@bgelectrical.co.uk
Environmental Protection
This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general ousehold waste. Some chemicals contained within electrical/electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co- operation is vital to ensure the success of these schemes and for the protection of the environment.