BG ELECTRICAL NXCONSIL-D Single to Double Converter Socket Instruction Manual
- June 11, 2024
- BG Electrical
Table of Contents
Wiring Accessories
Single to Double Converter Socket
Wiring Instructions
Power Off
Before commencing work always isolate the power at the consumer unit / fuse
box.
*Note — If your installation uses a four-lug metal mounting box, remove the top and bottom lugs or bend fully back.
Removal of Existing Accessory
- Unscrew the accessory from the wall/mounting box.
- Note the cable connections:
There will generally be three different wiring configurations, the wiring diagram shows 2 wires of each colour connected to each terminal (there could be 1 or 3 wires of each colour connected to each terminal) plus an additional connection between the mounting box earth terminal and the socket earth terminal.
Connection (See diagram)
- Line up the new accessory to mounting box and take note of where each terminal is located.
- Connect each wire to the matching terminal.
- An earth connection should always be made between the mounting box earth terminal and the accessory earth terminal, where fitted.
- All bare earth wires must be sheathed with green/yellow sleeving.
- When connecting the new accessory ensure that only the bare end of the wire enters the terminal and no bare wires are visible.
- Tighten terminal screws securely. (Do not over tighten)
- This socket is fitted with two linked terminals to provide a dual earth fa This is for use in “clean” installations where additional earth capacity is required to comply with Regulation 607 IEE Wiring Regulations.
Complete Installation & Test
- Carefully position the accessory into the mounting box, ensuring that no wires are trapped between the plate and the wall and secure with screws (do not over tighten) then insert screw covers (optional).
- Once the installation has been completed correctly, replace the fuse/ reset MCB (trip), switch the power back on at the consumer unit and test.
Safety Warning
For your safety, this product must be installed in accordance with local
Building Regulations. If in any doubt, or where required by the law, consult a
competent person who is registered with an electrical self-certification
scheme. Further information is available online or from your Local Authority.
Please read carefully and use in accordance with these safety wiring
instructions. Before commencing any electrical work ensure the supply is
switched off at the mains. Either by switching off the consumer unit or by
removing the appropriate fuse or turning off MCB (trip). Wiring should be in
accordance with the latest edition of the IET regulations (BS 7671).
To prevent fire hazard always use cable of the correct rating & type for the
application.
Warning do not exceed the load rating of this device as stated on the rear of
the product.
Wire Identification – Twin & Earth Cable
Note – As from 1st April 2004 new colour codes for hard wire installations
were introduced.
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
Removal of Existing Accessory
Wiring Diagram
Fitting New Converter Socket
Technical
Voltage : 220-250V~
Frequency : 50/60Hz
Rating : 20A 16AX
SBL Rating : 250W
Rating (Fan Isolator) : 10A 3 Pole
Rating (Bell Push) : 10A
Terminal capacity : 4 x 1mm² 4 x 1.5mm² 2 x 2.5mm² 1 x 4mm² 1 x 6mm²
Min box depth (profiled plates) : 1 & 2 gang switches 16mm Fan, 3, 4 & 6 gang
switches 25mm
Min box depth (flat plates) : 25mm
ASTA Approved
The ASTA quality mark is evidence that the product has been independently
tested to comply with the relevant clauses of the applicable standards.
Batch Code Explanation
yyWxx Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)
Address/Helpline
Luceco PLC
Stafford Park 1
Telford TF3 3BD
ENGLAND| (EU) Luceco SE
C/ Bobinadora 1-5
08302 Mataró
SPAIN
---|---
If you have further technical assistance you can get in touch with our
Technical Helpline on:
+44 (0)3300 249 279
technical.support@bgelectrical.co.uk
Environmental Protection
This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>