BG ELECTRICAL 804-IL-C Fan Isolator Ceiling Switch Instruction Manual
Wiring Instructions
Power Off
Before commencing work always isolate the power at the consumer unit / fuse
box.
*Note – If your installation uses a four-lug metal mounting box, remove
the top and bottom lugs or bend fully back.
Installation
- Install mounting box (metal or moulded) for either flush or surface mounting, ensuring appropriate size of product (Mounting box to be purchased separately).
- Select the most suitable entry point of the mounting box (knock-out) and route the cables through. If a metal box is used, a cable grommet should be fitted to the entry point.
- Cables should be prepared so a sufficient conductor length reaches the terminals. Strip the ends of the individual conductors leaving an adequate length bare to enter terminals.
Connection (See diagram)
- Line up the new accessory to mounting box and take note of where each terminal is located.
- Connect each wire to the matching terminal. An earth connection should always be made between the mounting box earth terminal and the accessory earth terminal, where fitted. All bare earth wires must be sheathed with green/yellow sleeving. When connecting the new accessory ensure that only the bare end of the wire enters the terminal and no bare wires are visible.
- Tighten terminal screws securely. (Do not over tighten)
Complete Installation & Test
- Carefully position the accessory into the mounting box, ensuring that no wires are trapped between the plate and the wall and secure with screws (do not over tighten) then insert screw covers (optional).
- Once the installation has been completed correctly, replace the fuse/ reset MCB (trip), switch the power back on at the consumer unit and test.
Fan Isolator – 3 Pole Switch
During repair or installation or routine maintenance the power supply to the
fan unit must be disconnected. This isolating switch can be installed as shown
in the diagrams to enable the remainder of the circuit to remain live. These
instructions should be read in conjunction with the instructions supplied with
the fan unit and the latest IET Wiring Regulations. Please follow the
appropriate wiring diagram for your particular installation.
Important
The continuity of the protective conductors must be maintained. The isolator
switch shall be so situated as to be inaccessible to a person using a fixed
bath or shower.
Safety Warning
For your safety, this product must be installed in accordance with local
Building Regulations. If in any doubt, or where required by the law, consult a
competent person who is registered with an electrical self-certification
scheme. Further information is available online or from your Local Authority.
Please read carefully and use in accordance with these safety wiring
instructions. Before commencing any electrical work ensure the supply is
switched off at the mains. Either by switching off the consumer unit or by
removing the appropriate fuse or turning off MCB (trip). Wiring should be in
accordance with the latest edition of the IET regulations (BS 7671). To
prevent fire hazard always use cable of the correct rating & type for the
application.
Warning do not exceed the load rating of this device as stated on the rear of
the product.
Wire Identification – Twin & Earth Cable
Note – As from 1st April 2004 new colour codes for hard wire
installations were introduced.
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
Technical
Voltage : 220-240V ac
Frequency : 50/60Hz
Rating : 10A
Terminal capacity : 4 x 1mm² 4 x 1.5mm² 2 x 2.5mm² 1 x 4mm²
Min box depth (profiled plates) : 25mm
Batch Code explanation
yyWxx Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)
Address/Helpline
Luceco PLC
Stafford Park 1
Telford TF3 3BD
ENGLAND
(EU) Luceco SE
C/ Bobinadora 1-5
08302 Mataró
SPAIN
If you have further technical assistance you can get in touch with our
Technical Helpline on: +44 (0)3300 249 279
technical.support@bgelectrical.co.uk
Environmental Protection
This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/ electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/ battery items in separate collection schemes, which cater forthe recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.