BG ELECTRICAL WP21ES-01 Weatherproof 13A Socket Instruction Manual
- June 11, 2024
- BG Electrical
Table of Contents
WP21ES-01 Weatherproof 13A Socket
Instruction Manual
Wiring Accessories
Weatherproof 13A Socket
– External Switched
– Large Housing with Adjustable Socket Position
Safety Warning
For your safety, this product must be installed in accordance with local
Building Regulations. If in any doubt, or where required by the law, consult a
competent person who is registered with an electrical self-certification
scheme. Further information is available online or from your Local Authority.
Please read carefully and use in accordance with these safety wiring
instructions. Before commencing any electrical work ensure the supply is
switched off at the mains. Either by switching off the consumer unit or by
removing the appropriate fuse or turning off MCB (trip). Wiring should be in
accordance with the latest edition of the IET regulations (BS 7671).
To prevent fire hazard always use cable of the correct rating & type for the
application.
Warning do not exceed the load rating of this device as stated on the rear of
the product.
Note – As from 1st April 2004 new colour codes for hard wire installations
were introduced.
EARTH = Green/Yellow Sleeving
NEUTRAL = Black (pre Apr 04) / Blue (after Apr 04)
LIVE = Red (pre Apr 04) / Brown (after Apr 04)
If installed correctly BG Electrical Weatherproof products provide an IP66
level of protection, this means that the sealed construction provides a very
high level of protection against the ingress of both water & dust. The cover
will seal regular sized plugs, however the cover must be closed and secured
when in use to provide the IP rating protection. Do not allow water to enter
the socket with the cover open.
Installation Instructions
Before commencing work always isolate the power at the consumer unit/fuse box.
-
The unit should be mounted on a clean, rigid vertical surface suitable to accept screw type fixings. Surface should be reasonably flat as unevenness could cause product damage or affect operation.
-
Remove Front assembly from Rear Box.
-
For cable entry, decide if conduit is being used & entry positions.
For side, top or rear entry the lowermost drain hole position MUST be drilled out using a 5mm drill. ONLY ONE drain hole position must be drilled.
For bottom entry a drain hole MUST NOT be drilled in Rear Box, but a drain hole MUST be drilled at lowermost point of conduit run.
For rear entry, drill/cut the appropriate size hole. For extra sealing protection, channels around knock-out and fixing holes are provided to accept a bead of sealant (not supplied) when fixing to mounting surface.
Note – The drilling of the drain hole or removing a knock-out will reduce the IP rating of the product. -
Mount the Rear Box using No.8 screws in all four, or at least two diagonal positions on fixing centres shown. The fixing holes are slotted to enable some rotation adjustment if required. Fit supplied Bungs over all used fixing screw positions to seal aperture recesses.
-
Make cable entry into rear box as required. Only remove the blanking plugs for positions used. Ensure adequate excess lengths of cable for connection to the Socket. Install & seal all cable glands & conduit to Manufacturer’s instructions.
To install, remove the blanking plug from rear box, and fit gland or conduit. Ensure the gland or conduit and cable entry are sealed with a non-setting sealant. -
Offer up Front Assembly to Rear Box to determine final lengths of cables & cut to suit. Strip outer insulation as required & then trim insulation on individual wires 10-12mm to expose conductor ends.
-
Connect the wires to the correct rear terminals.
Connect LIVE wire to BROWN LIVE (L) terminal
Connect NEUTRAL wire to BLUE NEUTRAL (N) terminal
Connect EARTH wire to GREEN/YELLOW (E) terminal
NOTE
(1) The colours of the wires will be dependent on the type of cable used.
(2) It is possible to remove the socket from the Front Assembly to aid wiring
by releasing the retaining screws on the rear.
WP21ES – Switched Socket Wiring Diagram
Product supplied pre-wired as a switched socket – do not disconnect the switch
from the socket and wire independently.
LIVE to “COM” on switch
EARTH to ****on socket
NEUTRAL to “N” on socket (ensure power indicator connection remains in the
terminal).
Safety Instructions
Please read carefully before installation.
- An outdoor location should be chosen ensuring adequate access to a mains supply circuit. The circuit MUST be protected by an appropriate fuse, circuit breaker or RCD (Residual Current Device) in accordance with current IET wiring regulations.
- Where conduit is used for cable runs, water condensation MUST be prevented from collecting inside the unit & conduit. Drain holes MUST be drilled out (see Installation Instructions).
- If metal conduit is used, earth continuity across the conduit must be maintained using appropriate connections (not supplied). An earth terminal in the Rear Box is provided as required.
- Where outdoor cable runs occur, ensure cable recommended for outdoor installations is used. In general, rubber insulated cable & plastic M20 cable glands can be used. Alternatively standard flat PVC twin & earth mains cable inside 20mm plastic or metal conduit may be used. Where necessary, SWA (Steel Wire Armoured) cable with metal cable glands should be used.
The outdoor use of unprotected flat PVC insulated cable is NOT recommended.
Large Enclosure with Adjustable Socket
This large enclosure is suitable for sealing RCD’s and transformer type plugs
in use where the socket position can be adapted to suit the plug type.
The following diagrams show the 3 arrangements for the socket position.
Select the socket position to suit the plug type of the connected appliance
(socket assembly should be fitted into position before wiring).
-
To relocate the socket assembly remove the mounting box to give access to the screws fixing the socket assembly and blanking mouldings.
-
Remove the 4 screws that fix the blanking mouldings into the frame, the socket fixing screws can then be unscrewed and the socket repositioned as required.
-
For all positions the socket assembly should be fitted before the blanking mouldings, removal is the reversal of this.
-
Locate and fix the socket assembly into the required position using the 2 screws (a).
-
Locate the blanking moulding ensuring that the tab is positioned into the recess in the socket plate (b).
-
The remaining blanking moulding should be fixed in the same manner (c).
-
WP23L – Large Adjustable Socket Wiring Diagram
-
All earth connections MUST be made & continuity maintained. Note – the Socket has two linked earth terminals but only one needs to be used for this installation.
-
Where any earth conductor is a bare wire, it MUST be sleeved with green/yellow sleeving.
-
Ensure all terminal screws are tight & all wires are neatly routed & not unduly stretched or pinched.
-
After wiring socket, refit Front Assembly onto Rear Box using fixing screws – DO NOT OVER TIGHTEN.
-
Fit Screw Covers to complete installation.
-
Switch power back on, check Socket is working & ensure Cover & Catch operate correctly. The product is now ready to use.
-
For security to prevent unwanted tampering with Socket, a lug feature with a 6mm hole is provided to accept a padlock or similar locking security device (not supplied).
Technical
Voltage : 240V ac
Frequency : 50/60Hz
Socket Rating : 13A
Terminal Capacity : 3 x 2.5mm², 3 x 4mm², 2 x 6mm²
IP Rating : IP66 (when cover securely closed)
Batch Code Explanation
yyWxx Manufacturing date code, year of manufacture (yy) and week of manufacture (Wxx)
Address/Helpline
Luceco PLC
Stafford Park 1
Telford TF3 3BD
ENGLAND| (EU) Luceco SE
C/ Bobinadora 1-5
08302 Mataró
SPAIN
---|---
If you have further technical assistance you can get in touch with our
Technical Helpline on: +44 (0)3300 249 279
technical.support@bgelectrical.co.uk
Care
This BG Electrical Nexus Storm Weatherproof accessory is made from
polycarbonate material that is durable with a high impact resistance. During
the life of the product any cleaning should be carried out with a damp cloth
using a mild detergent & warm water. DO NOT USE solvent based cleaners as
these may cause damage.
Environmental Protection
This symbol is known as the “Crossed-out Wheelie Bin Symbol”. When this symbol is marked on a product or battery, it means that it should not be disposed of with your general household waste. Some chemicals contained within electrical/electronic products or batteries can be harmful to health and the environment. Only dispose of electrical/electronic/battery items in separate collection schemes, which cater for the recovery and recycling of materials contained within. Your co-operation is vital to ensure the success of these schemes and for the protection of the environment.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>