SIEMENS S7-1200/S7-1500 Absolute Addressing Ethernet User Guide
- June 9, 2024
- SIEMENS
Table of Contents
SIEMENS S7-1200/S7-1500 Absolute Addressing Ethernet
Supported Series: Siemens S7-300/1200/1500 Series, ET200SP series
Website:
http://www.siemens.com/entry/cc/en/
Settings
HMI Setting
Parameters | Recommended | Options | Notes |
---|---|---|---|
PLC type | Siemens S7-1200/S7-1500 (Absolute Addressing) (Ethernet) | ||
PLC I/F | Ethernet | ||
Port no. | 102 | ||
Rack | 0 | ||
CPU slot | 1 | ||
On-line simulator | Yes | Multi-HMI connect | TIA Settings *Note |
--- | --- | --- | --- |
Connect S7-300 settings
Note: According to Connection resource / HMI Communication settings
Support Device Type:
S7-1200 data type | EasyBuilder data format | Memo |
---|---|---|
Bool | bit | |
Byte | 16-bit BCD, Hex, Binary, Unsigned | 8-bit |
SInt | 16-bit BCD, Hex, Binary, Signed | 8-bit |
USInt | 16-bit BCD, Hex, Binary, Unsigned | 8-bit |
Word | 16-bit BCD, Hex, Binary, Unsigned | 16-bit |
Int | 16-bit BCD, Hex, Binary, Signed | 16-bit |
UInt | 16-bit BCD, Hex, Binary, Unsigned | 16-bit |
DWord | 32-bit BCD, Hex, Binary, Unsigned | 32-bit |
DInt | 32-bit BCD, Hex, Binary, Signed | 32-bit |
Real | 32-bit Float | 32-bit |
UDInt | 32-bit BCD, Hex, Binary, Unsigned | 32-bit |
LInt | 64-bit Signed | |
ULInt | 64-bit Unsigned | |
LReal | 64-bit Double | |
Array |
Note: EasyBuilder Pro V6.03.02 or later supports 64 bits data type, but please note that the address limit range is 48 bits in maximum.
User define type
- User define type can be established in PLC data type
- User define type can be used in DB. User-defined types mapping address fuction are not supported. When using a user-defined type, please add it to the end of DB, to avoid influencing import and communication (address offset calculation).
- User define type cannot be imported automatically, you need to manually create an address in EasyBuilder Pro to communicate.
Device Address:
Bit/Word | Device type | Format | Range | Memo |
---|---|---|---|---|
B | I | DDDDDo | 0 ~ 655357 | Input (I) |
B | Q | DDDDDo | 0 ~ 655357 | Output (O) |
B | M | DDDDDo | 0 ~ 655357 | Bit Memory |
B | DBnBit | FFFFFDDDDo | 0 ~ 6553599997 | |
B | DBxBit | FFFFFDDDDDo | 0 ~ 10700655327 | |
B | DB1Bit-DB99Bit | DDDDDo | 0 ~ 655357 | Data Register Bit |
BYTE | IB | DDDDD | 0 ~ 65535 | Input (I) |
W | IW | DDDDD | 0 ~ 65533 | Input (I) |
DW | ID | DDDDD | 0 ~ 65535 | Input (I) |
BYTE | QB | DDDDD | 0 ~ 65535 | Output (O) |
W | QW | DDDDD | 0 ~ 65533 | Output (O) |
DW | QD | DDDDD | 0 ~ 65535 | Output (O) |
BYTE | MB | DDDDD | 0 ~ 65535 | Bit Memory |
W | MW | DDDDD | 0 ~ 65533 | Bit Memory |
DW | MD | DDDDD | 0 ~ 65535 | Bit Memory |
BYTE | DBBn | FFFFFDDDD | 0 ~ 655359999 | Data Register |
BYTE | DBBx | FFFFFDDDDD | 0 ~ 1070065535 | Data Register |
W | DBn | FFFFFDDDD | 0 ~ 655359999 | Data Register |
W | DBx | FFFFFDDDDD | 0 ~ 1070065535 | Data Register |
DW | DBDn | FFFFFDDDD | 0 ~ 655359999 | Data Register |
DW | DBDx | FFFFFDDDDD | 0 ~ 1070065535 | Data Register |
W | DBn_String | FFFFFDDDD | 0 ~ 655359999 | Char Array |
W | DBx_String | FFFFFDDDDD | 0 ~ 1070065535 | Char Array |
W | DBn_String1 | FFFFFDDDD | 0 ~ 655359999 | String |
W | DBx_String1 | FFFFFDDDDD | 0 ~ 1070065535 | String |
DW | DBDn_String | FFFFFDDDD | 0 ~ 655359999 | Char Array |
DW | DBDx_String | FFFFFDDDDD | 0 ~ 1070065535 | Char Array |
W | DB1 ~ DB99 | DDDDD | 0 ~ 65535 | Data Register |
DW | S5TIME_10Ms | FFFFFDDDD | 0 ~ 655359999 | 10MS ~ 9S990MS |
DW | S5TIME_100Ms | FFFFFDDDD | 0 ~ 655359999 | 100MS ~ 1M39S900MS |
DW | S5TIME_1S | FFFFFDDDD | 0 ~ 655359999 | 1S ~ 16M39S |
DW | S5TIME_10S | FFFFFDDDD | 0 ~ 655359999 | 10S ~ 2H46M30S |
- Double word and floating point value must use DBDn device type.
- When using DBn, DBDn, DBLn, DBx, DBDx, DBLx addresses, the object address must be an even number due to the limitation of the original software protocol.
PLC Setting:
Note: Please follow the settings below, or the communication may fail.
- Do not check [DB UTILITAIRES] -> [Attributes] -> [Optimized block access]
- Check [General] -> [Protection] -> [Permit access with PUT/GET communication from remote partner]
How to import address tags using TIA portal?
Exporting PLC Tags (.xlsx file format).
- Under [PLC tags] create the address tags and then click the Export icon.
- Designate the directory to save the file and click OK button.
Exporting Program Blocks (.scl file format).
-
Under [Program blocks] create “Data_block_1 [DB1]” as shown in the following figure. Click the right mouse button on [DB1] and then click [Generate source from blocks].
-
In EasyBuilder click [New PLC…], select Siemens S7-1500 (Ethernet) PLC type, and then click [Settings…] to set the parameters.
-
Click [Import Tag…] button.
-
Select file type (.scl; .db) or select TIA file (.apxx) for import. Compiling the TIA file by using TIA software before import is necessary to avoid importing incomplete data.
Note1. Please compile your project before importing TIA files (.ap12~17).
Note: CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)
Unable to import using TIA project (.ap), please use [Get tag info] instead. -
Import Files (.scl; .db)
Select the PLC Tags and Program Blocks to be imported, click [Import] button, and then click [OK] to leave when the tags are imported successfully.
* At least one db file must be imported. If only plc tags cannot be imported successfully. -
Import Files (.ap)
Select the tags to be imported and then click OK. (Support multiple devices in the same project) -
The following message window is shown if the import has succeeded.
Get Tag Info:
- In S7-1200/1500 program software create PLC program and tag and then download to PLC.
- Select Go offline, EasyBuilder will connect to PLC and get tag data. In PLC type select “SIEMENS S7-1200/1500 (Absolute Addressing) (Ethernet)”.
- Click “Settings …”, input PLC IP address.
- Check the PLC that is not connected to any PC. Click “Get tag info…”.
- Added Tag Manager that allows selecting the Siemens S7-1200/1500 PLC tags to be imported.
- Create an object and click read address “Settings…”
- In the device select “S7-1200/1500” then select “user-defined tag”.
- Select PLC tag.
Wiring Diagram
Ethernet cable:
Documents / Resources
|
SIEMENS S7-1200/S7-1500 Absolute Addressing
Ethernet
[pdf] User Guide
S7-1200 S7-1500 Absolute Addressing Ethernet, S7-1200 S7-1500, Absolute
Addressing Ethernet, Addressing Ethernet
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>