LEDone HB006 Microwave Motion Sensor Owner’s Manual

June 9, 2024
LEDone

HB006
Microwave Motion Sensor

HB006 Microwave Motion Sensor

Date: Location: ____
Product: Project: ____
Quantity: _____Catalog #: __

INPUT INPUT 10.5V-15V DC, >30mA
STANDBY CONSUMPTION <30mA (Power Consumption)
OUTPUT DIM OUTPUT 1-10V
DAYLIGHT PRIORITY FUNCTION Detection Area: 120Lux/80Lux/50Lux/30Lux Standby

period: +∞
Standby dimming level: 10%/ 20%/ 30%
SENSOR PARAMETERS| DETECTION AREA| 25% / 50% / 75% / 100%
HOLDTIME| 5s / 30s / lmin / 3min / 5rnin / 10min / 20rnin / 30min
DAYLIGHT THRESHOLD| 2Lux / 10Lux / 30Lux / SOLux / 80Lux / 120Lux / Disable
STANDBY PERIOD| Os / lOs / 30s/ lmin / 5min / 10min / 30min / 60min +.
STANDBY DIMMING LEVEL| 10%/ 20%/ 30%/ 50%
MICROWAVE FREQUENCY| 5.8GHz +/- 75MHz
MICROWAVE POWER| <0.3mW
MOUNTING HEIGHT| ≤39.37FT (12m) (ceiling mounted)
DETECTION RANGE| Max. 52.49ft (16m) (ceiling mounted)
MOTION DETECTION| 0.5 ~ 1m/s
OTHER| TEMPERATURE| -20°C – 60°C (-4°F – 140°F)
IP GRADE| IP65
WARRANTY| 5 years
REMARK| Factory Default Setting: Detection Area 100%/ Hold Time: 5s/
Daylight Threshold Disable / Standby Period: Os / Standby Dimming Level: 1031

MEASUREMENTS

DETECTION COVERAGE

OPTIONAL COMPATIBLE ACCESSORY

Remote Control LOC-GDHB-HD05R

DUSK/DAWN SENSOR

Dual-PD technology brings a fully automatic Dusk/Dawn sensor which can tell the difference between natural light and LED light to ensure the light will be off when needed.

Precondition of Daylight priority:

  1. Daylight threshold is on 30Lux/50Lux/80Lux/120Lux;
  2. Standby period is +00;
  3. Standby dimming level is on 10%/20%/ 30%.

Application Daylight priority

  • Daylight threshold is on 30Lux /5O0Lux /80Lux/120Lux;
  • Standby period is +∞; Standby dimming level is on 10%/20%/ 30%.

| | |
---|---|---|---
Light automatically on when ambient brightness is lower than preset lux level.| With insufficient ambient brightness, light dims to 100%
when motion detected.| Light dims to standby level if no motion detected after hold time.| Light off when ambient lux level is higher than preset lux amount.

Automatically ON/OFF Function:

  • Daylight threshold is on 2Lux/10Lux/30Lux/SOLux/80Lux/120Lux/200Lux;
  • Standby period is Os; Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase

| |
---|---|---
With sufficient daylight, even when motion detected, light remains OFF.| With insufficient daylight, when motion detected, light ON.| After the last detection and the present hold time elapsed, light OFF.

No Daylight Function:
* Daylight threshold is on “Disable”; Standby period is on 0s/10s/30s/1min/Smin/10min/30min/60min.

  • Light on when detect movement, After people leave, Light off after stand-by period.
  • Stand-by period is set to +o, The light will always remain ON.

| |
---|---|---
When motion is detected, the sensor will switch on the light to 100% brightness.| After people leave the detection area, light remains 100% brightness within hold time.| After the last detection and the present hold time elapsed, light OFF.

  • Daylight threshold is on 2Lux/10Lux/30Lux/50Lux /80Lux/120Lux/200Lux;
  • Standby period is on 0s/10s/30s/1 min/Smin/10min/30min/60min.
  • Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.

| | |
---|---|---|---
With sufficient daylight, even when motion detected, light remains OFF.| With insufficient daylight, when motion detected, fight ON.| After last detection, the light will be dimmed down to the stand-by dimming level (10%, 20%,30% or 50%) after hold time.| After the stand-by period, light OFF.

Dimmable Control / Coridor Function:
* Daylight threshold is on 2Lux/10Lux/30Lux /5O0Lux /80Lux/ 1 20Lux /200Lux;

  • Standby period is on 0s/10s/30s/ I min/Smin/1Omin/30min/60min.
  • Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.

| | |
---|---|---|---
With sufficient daylight, even when motion detected, light remains OFF.| With insufficient daylight, when motion detected, light ON.| After last detection, the light will be dimmed down to the stand-by dimming level (10%, 20%,30% or 50%) after hold time.| After the stand-by period, light OFF.

Phone: (844) LEDONE6 | Fax: 1-510-217-9461 | Web: www.ledonecorp.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LEDone User Manuals

Related Manuals