KARCHER SC 5 Easy Fix Series Steam Cleaner User Manual
- June 9, 2024
- Karcher
Table of Contents
- KARCHER SC 5 Easy Fix Series Steam Cleaner
- Product Usage Instructions
- General notes
- Intended use
- Environmental protection
- Accessories and spare parts
- Scope of delivery
- Warranty
- Safety devices
- Description of the device
- Installation
- Operation
- Important application instructions
- How to use the Accessories
- Steam ironing
- Care and service
- Troubleshooting guide
- Technical data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KARCHER SC 5 Easy Fix Series Steam Cleaner
Product Information
The SC 5 EasyFix is a steam cleaner that can be used for cleaning in
private households. It comes with various safety features such as a pressure
regulator, safety thermostat, and
boiler thermostat. The package includes a water tank, floor nozzle, hand
nozzle, extension tubes, power nozzle, round brush, and microfiber cloth. The
device has a power output of 2200 watts and a water tank capacity of 1.5
liters.
Product Usage Instructions
Assembly:
- Place the child safety lock to the back to lock the steam lever.
Operation:
- Pull the water tank straight up vertically. See Figure C.
- Place the child safety lock to the back to lock the steam lever.
- Turn the selector switch from the OFF position to the desired steam level.
- Press the steam button and start cleaning.
- To stop cleaning, unplug the device and empty the water tank.
Recommended Steam Levels:
Level | Fabric Type | Minimum Steam Level | Maximum Steam Level |
---|---|---|---|
I-IV | Jeans | – | 250 g/min |
Cotton | 60 g/min | 150 g/min | |
Silk | 60 g/min | 150 g/min | |
Wool | 60 g/min | 150 g/min |
Maintenance:
- Only use original accessories and spare parts. They ensure that the appliance will run fault-free and safely.
- Refer to the user manual for instructions on how to descale the device.
- Empty the water tank after each use and store the device in a dry place.
Environmental Protection:
- Dispose of the device and its accessories in accordance with local regulations.
- For information on the device’s ingredients, refer to www.kaercher.de/REACH.
General notes
Read these original operating instruc-tions and the enclosed safety instruc-
tions before using the device for the first time. Proceed accordingly.
Keep both books for future reference or for future owners.
Intended use
Only use the appliance in private households. The appliance is intended for cleaning with steam and can be used with appropriate accessories as described in these operating instructions. Detergents are not required. Observe the safety instructions.
Environmental protection
The packing materials can be recycled. Please dispose of packaging in
accordance with the environmental regulations.
Electrical and electronic appliances contain valuable, recyclable materials
and often components such as batteries, rechargeable batteries or oil, which –
if handled or disposed of incorrectly – can pose a potential threat to human
health and the environment. However, these components are required for the
correct operation of the appliance. Appliances marked by this symbol are not
allowed to be disposed of together with the household rubbish.
Notes on the content materials (REACH)
Current information on content materials can be found at:
www.kaercher.com/REACH
Accessories and spare parts
Only use original accessories and original spare parts. They ensure that the
appliance will run fault-free and safely.
Information on accessories and spare parts can be found at
www.kaercher.com.
Scope of delivery
The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.
Warranty
The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorized customer service site. (See overleaf for the address)
Safety devices
CAUTION
Missing or modified safety devices
Safety devices are provided for your own protection. Never modify or bypass
safety devices.
Symbols on the device
(according to type of appliance)
- Risk of burns, surface of appliance becomes hot during operation
- Risk of scalding from steam
- Read operating instructions
Pressure controller
The pressure controller keeps the pressure in the steam boiler as constant as
possible during operation. The heating is switched off when the maximum
operating pressure is reached in the steam boiler and is activated if there is
a pressure drop in the steam boiler as a result of a steam removal.
Safety thermostat
The safety thermostat prevents the device from overheating. If the pressure
regulator and the boiler thermo-stat fail and the unit overheats, the safety
thermostat switches the unit off. Before resetting of the safety thermostat,
contact the responsible KÄRCHER Customer Service.
Boiler thermostat
The boiler thermostat switches off the heating in the event of a fault; for
example, if there is no water in the steam boiler and the temperature in the
steam boiler ris-es.
As soon as you refill the water, the device is ready for use again.
Maintenance lock
The maintenance lock seals the steam boiler from the steam pressure present.
The maintenance cap is also a pressure relief valve. If the pressure regulator
is defec-tive and the steam pressure in the steam boiler rises, the pressure
relief valve opens and steam is escapes through the lock.
Prior to restarting the device, contact the responsible KÄRCHER Customer
Service.
Description of the device
The maximum amount of equipment is described in these operating instructions.
Depending on the model used, there are differences in the scope of delivery
(see packaging).
For the illustrations, refer to the graphics page. Illustration A
- Device socket with cover
- Water reservoir
- Carrying handle for the water reservoir
- Selector switch
- Control panel
- Display – OFF position
- Display – water shortage (red)
- Display – heating (green)
- Min. steam stage
- Steam setting selection range
- Max. steam stage
- VapoHydro function steam stage
- Cap for accessory compartment
- Maintenance lock
- Carrying handle
- Holder for accessories
- Accessory storage compartment
- Mains connection cable storage compartment
- Park bracket for floor nozzle
- Mains connection cable with mains plug
- Non-driven wheels (2 x)
- Steering roller
- Steam gun
- Steam lever
- Unlocking button
- Child lock
- Steam hose
- Steam connector
- Spotlight nozzle
- Round brush (small)
- **Power nozzle
- **Round brush (large)
- Manual nozzle
- Manual nozzle microfibre cover
- Extension tubes (2 x)
- Unlocking button
- Floor nozzle
- Hook and loop fastener
- Microfibre floor cloth (1 x)
- Microfibre floor cloth (2 x)
- Carpet glider
- Descaler
- Steam pressure iron
- Indicator light (orange) – heating
- Steam switch (bottom)
- Steam connector
optional
Installation
Installing accessories
-
Open the cover on the device socket. Illustration B
-
Connect the steam connector to the device socket so that the steam connector audibly engages. Illustration B
-
Push the open end of the accessory onto the steam gun so that the unlocking button on the steam gun engages.
Illustration H -
Push the open end of the accessory onto the spot-light nozzle.
Illustration I -
Connect the extension tubes with the steam gun.
a Push the 1st Push the first extension tube onto the steam gun so that the unlocking button on the steam gun engages.
The connection pipe is connected.
b Push the 2nd extension tube onto the 1st extension tube.
The connection pipes are connected. Illustration J -
Push the accessory and/or the floor nozzle onto the free end of the extension tube. Illustration K
The accessory is connected.
Disconnecting accessories
-
Set the child lock to the rear.
The steam lever is locked. -
Push the cover on the device socket down and disconnect the steam connector from the device socket.
-
Push the unlocking button and pull the parts apart. Illustration O
Operation
Filling water
The water reservoir can be removed at any time for fill-ing or be filled
directly at the device.
ATTENTION
Damage to the device
Unsuitable water can block the nozzles or damage the water level indicator.
Do not fill in pure distilled water. Use a maximum of 50% distilled water
mixed with tap water.
Do not use condensation from the clothes dryer for filling. Do not use
collected rainwater for filling.
Do not use cleaning agents or other additives (e.g. scents) for filling.
Remove the water reservoir for filling
- Pull the water reservoir vertically upwards. Illustration C
- Fill the water tank vertically with tap water or a mixture of tap water and no more than 50% distilled water up to the “MAX” mark.
- Insert the water reservoir and press downwards until it locks into place.
Filling the water reservoir directly on the device
- Fill tap water or a mixture of tap water and no more than 50% distilled water from a vessel into the filling hole of the water reservoir up to the “MAX” mark. Illustration D
Switching on the device
Note
If there is no or too little water in the steam boiler, the water pump starts
to run and pumps water from the water reservoir into the steam boiler. The
filling process can take several minutes.
Note
The device briefly closes the valve every 60 seconds causing an audible soft
click. Closing prevents the valve from clogging. This does not affect the
steam output.
-
Place the device on a firm surface.
-
Insert the mains plug into a socket. Illustration E
-
Turn the selector switch from the OFF position to the steam setting selection range.
The green heating indicator light flashes. Illustration F -
Wait until the green heating indicator stays on. Illustration G
-
Press the steam lever.
Illustration H Steam leaks out.
Regulating the steam volume
The expelled steam volume is regulated using the selector switch for steam volume. The selector switch has the setting options min. steam stage for light soiling to max. steam stage for heavy soiling. The VapoHydro function is for the removal of heavy soiling in areas that are difficult to access.
- Set the selector switch for the steam volume to required steam volume.
- Press the steam lever.
- Before starting cleaning, point the steam gun at a cloth until steam is expelled evenly.
Refilling water
If there is not enough water, the water shortage indicator lamp flashes red and a signal tone sounds.
Note
The water pump fills the steam boiler at intervals. If the filling is
successful, the red water shortage indicator lamp goes out.
Note
If there is no or too little water in the steam boiler, the water pump starts
to run and pumps water from the wa-ter reservoir into the steam boiler. The
filling process can take several minutes.
ATTENTION
Damage to the device
Unsuitable water can block the nozzles or damage the water level indicator.
Do not fill in pure distilled water. Use a maximum of 50% distilled water
mixed with tap water.
Do not use condensation from the clothes dryer for filling. Do not use
collected rainwater for filling.
Do not use cleaning agents or other additives (e.g. scents) for filling.
- Fill the water tank with tap water or a mixture of tap water and no more than 50% distilled water up to the “MAX” mark.
The device is ready for use.
Switching off the device
- Turn the trigger to “OFF” position.
Illustration N****
The device is switched off.
-
Set the child lock to the rear.
The steam lever is locked. -
Push the cap on the device socket down and disconnect the steam connector from the device socket.
-
Pull the mains plug out of the socket.
-
Drain the water reservoir.
Rinsing out the steam boiler
Rinse the device’s steam boiler out after every eighth filling of the tank.
-
Switch the device off; see Chapter Switching off the device.
-
Allow the device to cool down.
-
Drain the water reservoir.
-
Remove the accessory/accessories from the accessory holders.
-
Open the cap of the accessory compartment.
-
Remove the accessory/accessories from the accessory compartment.
-
Open the maintenance lock. To do this place the open end of an extension tube on the maintenance lock, insert this into the guide so it engages and open it.
Illustration R**** -
Fill the steam boiler with water and swing it around vigorously. Lime residue which has been deposited on the bottom of the steam boiler will be released as a result.
-
Drain the water completely out of the steam boiler. Illustration S
Storing the device
- Store the round brush in the accessory compartment.
- Connect a manual nozzle to one extension tube.
- Connect the extension tubes to the accessory holders.
- Insert the spotlight nozzle in the storage for accessories.
- Hang the floor nozzle in the park bracket. Illustration P
- Wind the steam hose around the extension tube and connect the steam gun to the floor nozzle. Illustration Q
- Store the mains cable in the storage for the mains cable.
- Store the device in a dry location that is protected from frost.
Important application instructions
Cleaning the floor areas
We recommend sweeping the floor or vacuum cleaning it before using the
appliance. In this way the floor will be cleared of dirt and loose particles
before the wet cleaning.
Freshening up textiles
Prior to using the appliance, always check the compati-bility of the textiles
at a concealed point: Steam down the textile, allow it to dry and then check
it for any change in colour or shape.
Cleaning coated or painted surfaces
ATTENTION
Damaged surfaces
Steam can loosen wax, furniture polish, plastic coatings or paint and edge
band from edges.
Do not direct the steam at glued laminated edges as the edge band may loosen.
Do not use the appliance for cleaning unsealed wood or parquet floors.
Do not use the appliance for cleaning painted or plastic-coated surfaces such
as kitchen or living room furniture, doors or parquet.
- To clean these surfaces, steam a cloth briefly and use it to wipe over the surfaces.
Glass cleaner
ATTENTION
Glass breakages and damaged surfaces
Steam can damage sealed points of the window frame and, at low outside
temperatures, lead to tension on the surface of window panes and hence to
glass breakages. Do not direct the steam at sealed points on the window frame.
At low outside temperatures, heat up the window panes by gently steaming the
full surface of the glass.
- Clean the window area with a manual nozzle and cover. To remove the water, use a squeegee or wipe the surfaces dry.
How to use the Accessories
Steam gun
The steam gun can be used for the following applica-tions without accessories:
- For removing slight creases from the hanging cloth-ing items: Steam the clothing item from a distance of 10- 20 cm.
- For wiping damp dust: Steam a cloth briefly and use it to wipe over the furniture.
Spotlight nozzle
The spotlight nozzle is suitable for cleaning areas, joins, fittings, drains,
sinks, WCs, blinds or radiators that are difficult to access. The closer the
spotlight nozzle is to the soiled area, the greater the cleaning efficiency
will be as the temperature and steam volume are at their highest at the nozzle
opening. Larger lime deposits can be treated before steam cleaning with a
suitable deter-gent. Allow the detergent to soak in for approx. 5 minutes and
then steam it off.
- Slide the spotlight nozzle onto the steam gun.
Illustration H
Round brush (small)
The small round brush is used for cleaning stubborn dirt. Stubborn dirt can be removed more easily by brushing.
ATTENTION
Damaged surfaces
The brush may scratch sensitive surfaces.
It is not suitable for cleaning sensitive surfaces.
- Fit the round brush to the spotlight nozzle.
Illustration I
Round brush (large)
The large round brush is suitable for cleaning large rounded surfaces, e.g.
wash basin, shower tray, bath tub, kitchen sink.
ATTENTION
Damaged surfaces
The brush may scratch sensitive surfaces.
It is not suitable for cleaning sensitive surfaces.
- Fit the large round brush to the spotlight nozzle.
Illustration I
Power nozzle
The power nozzle is used for cleaning stubborn dirt, blowing down corners,
joins etc.
- Install the power nozzle onto the spotlight nozzle according to the round brush. Illustration I
Manual nozzle
The manual nozzle is used for cleaning small areas that can be washed down, shower cubicles and mirrors.
-
Push the manual nozzle onto the steam gun according to the spotlight nozzle.
Illustration H -
Pull the cover over the manual nozzle.
Floor nozzle
The floor nozzle is used for cleaning washable wall and floor coverings e.g.
stone floors, tiles and PVC floors.
ATTENTION
Damage due to build-up of steam
Heat and moisture can lead to damage.
Check the heat resistance and steam effect on an inconspicuous area using a
minimal volume of steam prior to use.
Note
Detergent residue or care emulsions on the surface to be cleaned can lead to
streaks during steam cleaning, which will disappear however once these have
been used several times.
We recommend sweeping the floor or vacuum cleaning it before using the device.
In this way the floor will be cleared of dirt and loose particles before the
wet cleaning commences. Work slowly on surfaces that are heavily soiled so
that the steam has longer to take effect.
- Connect the extension tubes with the steam gun. Illustration J
- Push the floor nozzle onto the extension tube. Illustration K
- Fasten the floor cleaning cloth to the floor nozzle. a Place the floor cleaning cloth with the hook and loop fastener strips pointing upwards on the floor. b Place the floor nozzle onto the floor cleaning cloth, applying slight pressure. Illustration L
The floor cleaning cloth will stick to the floor nozzle of its own accord due to the hook and loop fastener.
Removing the floor cleaning cloth
- Place one foot on the bottom corner of the floor cleaning cloth and lift the floor nozzle up. Illustration L
Note Initially, the floor cleaning cloth’s hook and loop fastener strip is very strong and cannot be removed from the floor nozzle easily. After the floor cleaning cloth has been used several times and washed, it is easier to re-move from the floor nozzle and it has reached the opti-mum adhesion.
Parking the floor nozzle
- Hang the floor nozzle in the park bracket during breaks in work. Illustration P
Carpet glider
The carpet glider is used for freshening up carpets.
ATTENTION
Beware of damaging the carpet glider and carpet
Contamination on the carpet glider, as well as heat and moisture penetration,
can result in the carpet being damaged.
Prior to the application, also check the heat resistance and impact of steam
on the carpet at an insignificant spot using as small an amount of steam as
possible. Observe the cleaning instructions from the carpet manufacturer.
Prior to using the carpet glider, make sure that the carpet has been vacuumed
and that stains have been removed.
Prior to application and following operating pauses, remove any possible water
accumulation (condensate) in the appliance by means of evaporating the
condensate into a drain (without floor cleaning cloth / with accessories).
Only use the carpet glider with a floor cleaning cloth on the floor nozzle.
Steam clean with a weak steam stage when using the carpet glider.
In order to prevent too much moistening and to avoid the risk of damage due to
temperature effects, do not direct the steam continuously onto one spot
(maximum 5 seconds).
Do not use the carpet glider on deep-pile carpets.
Fastening the carpet glider to the floor nozzle
-
For fastening the floor cleaning cloth to the floor nozzle, please refer to chapter Floor nozzle. Illustration L
-
Using a little force, allow the floor nozzle to slide into the carpet glider and engage there.
Illustration M -
Start cleaning the carpet.
Removing the carpet glider from the floor nozzle
CAUTION
Beware of burns to your feet
The carpet glider can heat up during the steaming pro-cess.
Do not operate or remove the carpet glider bare-footed or using open sandals.
Only operate or remove the carpet glider using suitable footwear.
- Press the strap on the carpet glider downwards us-ing your toecap.
- Lift the floor nozzle upwards.
Illustration M****
Iron steam pressure
Note
We recommend using the KÄRCHER ironing board with active steam suctioning.
This ironing board is optimally matched to the device you have acquired. It
facilitates and speeds up the ironing process. In any case, the ironing board
used should have a steam-permeable, grid-like ironing base surface.
Note
It should be noted that in the case of an ironing board without steam
extraction, it is possible for an ironing board cover to become wet if
condensate accumulates.
Initial startup of steam pressure iron
ATTENTION
Material damage due to condensate/moisture Ironing may cause condensation
to drip on the floor and damage sensitive floor coverings.
If possible, perform ironing tasks on a floor covering which is insensitive to
condensation (e.g. tiles/stone). For sensitive floor covering, ensure that the
area on which condensation can drip is adequately protected (e.g. water-
impermeable floor mat).
Note
The iron plate must be hot to prevent steam from con-densing on the sole plate
and dripping onto the ironing laundry.
Note
Do not turn on the steam stage for the VapoHydro func-tion when the steam
pressure iron is plugged in, since otherwise the ironing laundry will get wet.
Recommended steam stages
level | Clothing fabrics |
---|---|
Min. steam stage | Garments with few wrin- kles |
Max. steam stage | Jeans |
- Ensure that tap water or a mixture of tap water and no more than 50% distilled water is in the steam boiler of the steam cleaner.
- Insert the steam plug of the iron into the unit plug until it clicks into place.
- Putting the steam cleaner into operation, see chapter Switching on the device.
- Wait until the steam cleaner is ready for use.
- The iron is ready for use as soon as the indicator light (orange) has gone out.
- The warning light comes on during use, when the iron is reheating. The application must not be interrupted during reheating.
Steam ironing
ATTENTION
Damage to garments
Failure to observe the ironing information in the garment may result in
damage.
Observe the ironing information in the garment.
Note
With the fixed, optimal temperature setting, all ironable tex-tiles can be
ironed without additional temperature setting. Smooth delicate fabrics and
imprints on the back with steam without direct contact with the iron. Steaming
the fabrics at a distance of 2 to 3 cm will gently straighten the fibres.
Note
The iron is fitted with an automatic switch-off which switches off the device
if it has not been moved for more than 5 minutes. This automatic shut-off
increases safety and saves energy as the iron does not heat up continu-ously.
The iron will switch back on as soon as it is moved and start heating up.
Note
The iron can be held vertically for steaming curtains, dresses, etc.
- As soon as the heating indicator light (orange) of the iron goes out, ironing can be started.
- Press the steam switch on the handle below. Steam emits as long as the switch is pressed.
- Before ironing and after pauses in the ironing process, direct the blast of steam onto a cloth until the steam flows evenly.
Dry ironing
ATTENTION
Damage to the device
Water shortage in the steam boiler leads to damage to the device
Make sure that there is water in the steam boiler.
ATTENTION
Damage to garments
Failure to observe the ironing information in the garment may result in
damage.
Observe the ironing information in the garment.
Note
With the fixed, optimal temperature setting, all ironable tex-tiles can be
ironed without additional temperature setting. Delicate fabrics and prints
should not be dry-ironed.
- Wait until the heating indicator light (orange) of the iron goes out.
The iron is ready for ironing.
Care and service
Descaling the steam boiler
Note
Since the lime clogs the appliance, we recommend descaling the appliance based
on the number of times the water reservoir is filled as specified in the table
(TF=tank fillings).
Hardness range | °dH | mmol/l | TF |
---|---|---|---|
I | soft | 0-7 | 0-1.3 |
II | Medium | 7-14 | 1.3-2.5 |
III | Hard | 14-21 | 2.5-3.8 |
IV | Very hard | >21 | >3.8 |
Note
Your water board or municipal utilities authority can pro-vide information on
hardness of tap water.
ATTENTION
Damaged surfaces
The descaler may corrode sensitive surfaces. Fill and empty the appliance
carefully.
-
Switching off the device, see chapter Switching on the device.
-
Allow the device to cool down.
-
Drain the water reservoir.
-
Remove the accessory/accessories from the accessory holders.
-
Open the cap of the accessory compartment.
-
Remove the accessory from the accessory compartment.
-
Open the maintenance lock. To do this place the open end of an extension tube on the maintenance lock, insert this into the guide so it engages and open it.
Illustration R -
Drain the water completely out of the steam boiler. Illustration S** ATTENTION
**
Appliance damage due to descaler
An unsuitable descaler or incorrect dosing of the descal-er may damage the
appliance.
Only use KÄRCHER descaler.
Use 1 dosing unit of the descaler for 0.5 l water.
- Apply descaler solution to the descaler according to the details.
- Fill the descaler solution into the steam boiler. Do not seal the steam boiler.
- Allow the descaler solution to take effect for approx. 8 hours.
- Drain descaler solution completely out of the steam boiler.
- Repeat the descaling process if necessary.
- Rinse the steam boiler 2-3 times with cold water in order to drain all the descaler solution residue.
- Drain the water completely out of the steam boiler. Illustration S
- Dry the mounting for the grid connection cable.
- Close the maintenance lock with an extension tube.
Care of accessories
(Accessories – depending on scope of delivery)
Note
The micro fibre cloths are not suitable for dryer. Note
When washing the cloths, observe the instructions on the washing tag. Do not
use any liquid softeners as this will affect the ability of the cloths to pick
up dirt.
Wash the floor cleaning cloths and covers at a max. temperature of 60 °C in
the washing machine.
Troubleshooting guide
Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.
WARNING
Risk of electric shock and burns
Trying to eliminate faults while the appliance is connect-ed to the mains or
has not yet cooled down is always dangerous.
Remove the mains plug.
Allow the appliance to cool down.
The water shortage indicator light flashes red and a signal tone sounds
No water in the tank.
Fill the water reservoir up to the “MAX” marking. The water shortage indicator
light is lit in red
No water in the steam boiler. The pump’s overheat protection has triggered.
- Switch the device off; see Chapter Switching off the device.
- Fill the water reservoir.
- Switch on the device; see Chapter Switching on the device.
The water tank is not inserted correctly or is calcified.
- Remove the water reservoir.
- Rinse the water reservoir.
- Insert the water reservoir and press downwards until it locks into place.
The steam lever cannot be pressed
The steam lever is locked with the child lock.
Set the child lock (selector switch for steam volume) to the front.
The steam lever is released.
-
Long heating-up time The steam boiler is scaled.
-
Descale the steam boiler.
High water output
The steam boiler is scaled. -
Descale the steam boiler.
VapoHydro steam stage set. -
Turn the selector switch to the steam setting selection range.
-
The steam pressure iron “spits” water
Rinse or descale the steam boiler of the steam cleaner; see Chapter Descaling the steam boiler -
After ironing breaks, water droplets come out of the steam pressure iron
During longer ironing breaks, steam can condense in the steam line.
After pauses in the ironing process, direct the blast of steam onto a cloth until the steam flows evenly.
Technical data
Electrical connection|
---|---
Voltage| V| 220-240
Phase| ~| 1
Frequency| Hz| 50
Degree of protection| | IPX4
Protection class| | I
Performance data| |
Heating capacity| W| 2200
Heating capacity of iron| W| 700
Maximum operating pressure| MPa| 0.42
Heating-up time| Minutes| 3
Continuous steaming| g/min| 60
Maximum steam blast| g/min| 150
VapoHydro steam volume| g/min| 250
Filling quantity| |
Water reservoir| l| 1.5
Steam boiler| l| 0.5
Dimensions and weights| |
Weight (without accessories)| kg| 6.0
Length| mm| 439
Width| mm| 301
Height| mm| 304
Subject to technical modifications.| |
References
- Cher - Official Site
- Cleaning equipment and pressure washers | Kärcher International
- Cleaning equipment and pressure washers | Kärcher International
- Dealer Search | Kärcher International
- Home and Garden Warranty Registration USA - Kärcher