KARCHER SP 6 Flat Inox Clear Water Submersible Pump Instructions

October 27, 2023
Karcher

KARCHER-logo

KARCHER SP 6 Flat Inox Clear Water Submersible Pump

KARCHER-SP-6-Flat-Inox-Clear-Water-Submersible-Pump-
product

Please read and comply with these original operating instructions and the enclosed safety instructions. Proceed accordingly. Keep both booklets for future reference or subsequent owners.

Warranty

The warranty terms published by the relevant sales company are applicable in each country. We will repair potential failures of your appliance within the warranty period free of charge, provided that such failure is caused by faulty material or defects in manufacturing. In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service center. Please submit the proof of purchase. The adhesive-type label must not be removed from the device. Warranty is no longer granted if the label is removed.

Environmental protection
The packaging material can be recycled. Please do not place the packaging into the or-dinary refuse for disposal, but arrange for the proper recycling. Old appliances contain valuable materials that can be recycled. Please arrange for the proper recycling of old appliances. Please dispose your old appliances using appropriate collection systems.

Note
The oil used to seal the ceramic slide ring is biodegradable. No negative effects are expected for humans or the environment if the oil smears or leaks.

Notes about the ingredients (REACH)
You will find current information about the ingredients at:
www.kaercher.com/REACH.

Description of the Appliance

  1. Switch (automatic mode/manual operation)
  2. Carrying handle
  3. Power cord with plug
  4. Rail (level sensor)
  5. Level sensor
  6. Automatic venting device
  7. Quick-Connect
  8. Pump connecting pieces (1“, 1¼“ and 1½“ hose connection and G1½ – thread)
  9. Check valve (SP 6 Flat Inox)
  10. Connection nozzle (G1½ – thread)
  11. Pre-filter (SP 6 Flat Inox removable)
  12. Support legs (SP 6 Flat Inox)KARCHER-SP-6-Flat-Inox-Clear-Water-Submersible-Pump-fig-1 KARCHER-SP-6-Flat-Inox-Clear-Water-Submersible-Pump-fig-2

Proper use

This appliance has been designed for use in private households and is not intended for commercial use. The manufacturer is not responsible for any damages that may occur on account of improper use or wrong operations. The device is mainly intended for draining building parts in case of flooding, but also for pumping over or out containers, for water removal from wells and shafts as well as for draining water from boats and yachts, provided that it is fresh water.

NOTICE
The device is not suitable for continuous pump operation (e.g. continuous circulation in a pond) or as a stationary installation (e.g. lifting device, fountain pump).

Approved feed fluids

  • Freshwater up to a certain degree of soiling
  • Water from the swimming pool (provided the dosing of additives is proper)
  • Washing lye, e.g. leaked washing machine load. Then clean with clear water.

Sp 7 Dirt Inox (wastewater pump)

  • Water with a degree of contamination up to a grain size of 30 mm

SP 6 Flat Inox (clean water pump)

  • Water with impurities up to a maximum grain size of 5mm

DANGER
Risk of injury, risk of damage! Caustic, slightly inflammable and other explosive substances (such as petrol, petroleum, diluted nitrogen), greases, oils, salt water, and wastewater from toilets as well as sludgy water that has a slower flow capacity than water, must not be transported with this pump. The temperature of the delivered fluid must be between 5 °C and 35 °C.

Startup

NOTICE
The shorter the hose length and the larger the hose diameter, the higher the pump capacity. In order to prevent the pump from clogging, use the en-closed pre-filter (SP 6 Flat Inox) or slide down the integrated pre-filter (SP 7 Dirt Inox) with hose diameters of less than 1¼ “. The pump connection is equipped with a plug system (Quick-Connect). The unmounted connection nozzle with the pump connecting piece is enclosed in the device.
Illustration AKARCHER-SP-6-Flat-Inox-Clear-Water-Submersible-Pump-
fig-3

  • To remove the connection nozzle, press the Quick-Connect (grey button).

Illustration B

  • Screw the pump connecting piece onto the connection nozzle.
  • Slide the hose clamp onto the hose.
  • Slide the hose onto the pump connecting piece and secure it by means of a hose clamp.
  • Slide the connection nozzle into the Quick-Connect.

NOTICE
Hoses with a diameter of 1“, 1¼“, and 1½“ can be connected to the pump connecting piece. A sufficiently large hose diameter must be selected and the pump connecting piece must be shortened according to the grooves so that the required particle size can be used. A large hose diameter is also recommended for smaller particle sizes to allow a high flow volume.

Illustration C

  • Slide the level sensor onto the rail from the top.

Illustration D

KARCHER-SP-6-Flat-Inox-Clear-Water-Submersible-Pump-
fig-6

  • Fold out or fold in the support legs (SP 6 Flat Inox) for the pump start.

NOTICE
It is not mandatory to fold out the support legs; a higher pump capacity is achieved by folding out the support legs. Folding in the support legs enables the flat vacuuming of the fluid up to a residual fluid height of up to 1 mm.

  • Install or uninstall pre-filter (SP 6 Flat Inox).
  • Slide down or up the pre-filter (SP 7 Dirt Inox).

NOTICE
It is not necessary to install the pre-filter, but a higher pump capacity is reached by installing the pre-filter (only for SP 6 Flat Inox). The feed fluids are pre-filtered by the pre-filter to protect the pump from heavy contamination. Particles up to 5 mm can still be used in the filter. Disassembly of the pre-filter allows for the flat vacuum-ing of the fluid up to 1 mm residual fluid height (SP 6 Flat Inox).

  • Safely place the pump on a stable surface in the feed fluid or immerse it using a rope tied to the carrying handle.

NOTICE
The suction area must not be blocked by soil. In case of muddy ground, place the pump on a brick or the like. Ensure that the pump is level. Do not carry the pump on the cable or the hose.

Operation

DANGER
Risk of mortal danger on account of electric shock! Do not touch feed fluids, the rope attached to the carry-ing handle as well as objects that are in contact with the feed fluid (e.g. pipelines extending into the water, rail- ings, etc.).

General

Illustration FKARCHER-SP-6-Flat-Inox-Clear-Water-Submersible-Pump-
fig-8 NOTICE
In order for the pump to draw independently, the fluid level must be at least 50 mm (SP 7 Dirt Inox) or 7 mm (SP 6 Flat Inox). The pump can pump up to a residual fluid height of 35 mm (SP 7 Dirt Inox) or 1 mm (SP 6 Flat Inox).

Automatic venting device

Illustration E
With a low fluid level, possibly drawn air or air that is present in the pump escapes via the automatic venting device. In addition, fluid may leak at this spot. If the pump has suction problems with a low fluid level, unplug and plug in the mains plug repeatedly in order to support the suction process.

Automatic operation

NOTICE
In the automatic mode, the level sensor automatically controls the pumping operations. As soon as the level sensor has contact with the rising feed fluid the pump switches on. The pump switches off as soon as the level sensor loses contact with the falling feed fluid and an after-running time of 15 s has passed.

Switching on:
Minimum fluid level required to enable the pump to function independently (=minimum switch-on point):

  • SP 6 Flat Inox: 7 mm (57 mm when using the pre-filter) SP 7 Dirt Inox: 50 mm

Highest adjustable switching height of the level sensor:
SP 6 Flat Inox: 190 mm without pre-filter (240 mm when using the pre-filter)

  • SP 7 Dirt Inox: 237 mm

Minimum residual fluid height/max. Extraction depth:
The pump can pump out up to a residual liquid height of SP 6 Flat Inox: 1 mm (without pre-filter, with folded base) SP 7 Dirt Inox: 35 mm

NOTICE
It is recommended to use the pre-filter.

NOTICE
Ensure that the pump is level. Otherwise, it can happen that the level sensor does not lose the fluid contact and the pump runs dry.

  • Push the level sensor to the desired switch-on height (contact with feed fluid).

NOTICE
The higher the level sensor is adjusted, the higher the switch-on and switch- off point. See the following table for application examples:KARCHER-SP-6
-Flat-Inox-Clear-Water-Submersible-Pump-fig-10

  • Set the switch to automatic mode (AUTO).
  • Insert the mains plug into the socket.

Manual operation

NOTICE
In manual operation, the pump remains switched on continuously.
Illustration G

  • Set the switch to manual operation (MAN).
  • Insert the mains plug into the socket.

ATTENTION
Risk of damage! Dry running leads to increased wear; never leave the pump unattended during manual operation. Unplug immediately in case of dry running.

Flat vacuuming (SP 6 Flat Inox)

It is recommended to use manual mode to reach the min. residual fluid height of 1 mm. A check valve is installed for the SP 6 Flat Inox. This prevents residual fluid in the hose from flowing back after the pumping process finishes.

Finish operation

NOTICE
Soiling can deposit and lead to malfunctions.

  • Pump clear water or thoroughly rinse the pump af-ter every use. This especially applies after pumping chlorinated water or other liquids that leave residue.
  • Disconnect the main plug from the socket.

Maintenance

The pump is maintenance-free.

Transport

CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the appliance during transport (see Specifications).

  • Lift and carry the pump on the carrying handle.
  • If you want to transport the appliance on a vehicle secure it from slipping.

Storage

CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the appliance when selecting a storage lo-cation for it (see Specifications).

Storing the pump

  • Completely drain the pump and allow it to dry.
  • Store the pump in a frost-free place.

Special accessories

KARCHER-SP-6-Flat-Inox-Clear-Water-Submersible-Pump-
fig-11

Troubleshooting

DANGER

Risk of mortal danger on account of electric shock!
To avoid risks, all repairs and replacement of spare parts may only be carried out by authorised customer service personnel.KARCHER-SP-6-Flat-Inox-Clear-
Water-Submersible-Pump-fig-12

Specifications

KARCHER-SP-6-Flat-Inox-Clear-Water-Submersible-Pump-
fig-13

Subject to technical modifications.KARCHER-SP-6-Flat-Inox-Clear-Water-
Submersible-Pump-fig-14

The possible delivery rate is even larger:

  • the lower the delivery height
  • the larger the diameter of the hose used
  • the shorter the hose used
  • the lower the pressure loss caused by the connected accessories.

THANK YOU!

  • Register your product and benefit from many advantages.

www.kaercher.com/welcome

  • Rate your product and tell us your opinion.

www.kaercher.com/dealersearch

Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28-40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals