HANNA HI97115 Marine Master Waterproof Wireless Multiparameter Photometer User Manual
- June 9, 2024
- HANNA
Table of Contents
HANNA HI97115 Marine Master Waterproof Wireless Multiparameter Photometer
Marine Master Waterproof Wireless Multiparameter Photometer
pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate Low Range, Nitrate High
Range, Nitrite Ultra Low Range, Phosphate Ultra Low Range The HI97115 is a
compact and versatile Marine multiparameter photometer designed to accurately
determine pH, Alkalinity, Ammonia, Calcium, Magnesium, Nitrate, Nitrite, and
Phosphate levels in aquariums and marine biology applications. The HI97115 is
suitable for field and bench measurements.
The HI97115 can be used as a stand-alone photometer or can be connected to the
Hanna Lab App with a compatible smart device via the integrated Bluetooth
module. When connected, Hanna Lab App functions include measurement with the
ability to add notes, data logging with extended storage capacity, data
sharing, and the ability to create and save method groups.
Precise and advanced LED optical system
Innovative optical design that utilizes a reference detector and focusing lens
to eliminate errors from changes in the light source and from imperfections in
the glass cuvette. LEDs have a much higher luminous efficiency, providing more
light while using less power. They also produce little heat, which could
otherwise affect electronic stability
-
Waterproof and floating IP67 meter design
-
Option to select measurement location for better tracking consistency
-
CAL Check™ validation and calibration
Validate instrument performance at any time using CAL Check cuvettes made with NIST traceable standards. The CAL Check screen guides the user step-by-step through the validation process and user calibration. GLP data displays the last calibration date.
-
Backlit LCD and on-screen help to guide users
-
Built-in reaction timer that ensures consistency between tests.
-
On-screen tutorial mode with animations
The built-in tutorial mode guides users step-by-step through the measurement process. It includes all steps required for sample preparation, the required reagents and quantities. Tutorial mode can be easily enabled or disabled from the setup menu.
-
Includes auto-data logging features to easily record water testing results The instrument features a data autolog function to help users keep track of all measurements. Every time a measurement is made the data is automatically saved. The data log can hold 200 individual measurements. When the data log is full (200 data points), the meter will rewrite the oldest data point.
-
Positive locking system
The Hanna positive-locking system ensures cuvettes are placed into the holder in the same position every time.
Hanna Lab App
When used with the HI97115, the Hanna Lab App adds an enhanced user experience
to a compatible smart device. Features include: measurement with the ability
add notes, data logging with extended storage capacity, data sharing, and the
ability to create and save method groups..
-
Samples can be named along with annotations
-
View logged detail with date and time
-
Share logged data in various formats
-
Control meter settings within the Hanna Lab App
Specifications
Marine pH | Range | 6.3 to 8.6 pH |
---|---|---|
Resolution | 0.1 pHC | |
Accuracy | ±0.2 pH of reading at 25 °C | |
Method | Colorimetric Adaptation of the Phenol Red Method | |
LED | 525 nm | |
Marine Alkalinity | Range | 0.0 to 20.0 dKH |
Resolution | 0.1 dKH | |
Accuracy | ±0.3 dKH ±5 % of reading at 25 °C | |
Method | Colorimetric Method | |
Marine Ammonia | Range | 0.00 to 2.50 ppm (as NH₃) |
Resolution | 0.01 ppm | |
Accuracy | ±0.05 ppm ±5% of reading at 25 °C | |
Method | Adaptation of the Salicylate Method | |
LED | 610 nm | |
Marine Calcium | Range | 200 to 600 ppm |
Resolution | 1 ppm | |
Accuracy | ±6% of reading at 25 °C | |
Method | Adaptation of the Zincon Method | |
LED | 610 nm | |
Marine Magnesium | Range | 1000 to 1800 ppm (as Mg2+) |
Resolution | 5 ppm | |
Accuracy | ±5% of reading at 25 °C | |
Method | Adaptation of the Colorimetric EDTA Method using calmagite |
indicator
| LED| 610 nm
Marine Nitrate LR| Range| 0.00 to 5.00 ppm (as NO₃–)
| Resolution| 0.01 ppm
| Accuracy| ±0.25 ppm ±2% of reading at 25 °C
| Method| Zinc Reduction Method
| LED| 525 nm
Marine Nitrate HR| Range| 0.0 to 75.0 ppm (as NO₃
| Resolution| 0.1 ppm
| Accuracy| ±2.0 ppm ±5% of reading at 25 °C
| Method| Zinc Reduction Method
| LED| 525 nm
Marine Nitrite ULR| Range| 0 to 200 ppb (as NO₂–-N)
| Resolution| 1 ppb
| Accuracy| ±10 ppb ±4% of reading at 25 °C
| Method| Adaptation of the EPA Diazotization Method 354.1
| LED| 525 nm
Marine Phosphate ULR| Range| 0.00 to 0.90 ppm
| Resolution| 0.01 ppm
| Accuracy| ±0.02 ppm ±5% of reading at 25 °C
| Method| Adaptation of Standard Methods for the Examination of Water and
Wastewater, 20th Edition, Ascorbic Acid Method
| LED| 610 nm
Measurement system| system Light source| LED
| Bandpass filter| Wavelength 525 nm & 610 nm
bandwidth 8 nm
wavelength accuracy ±1.0 nm
| Light detector| silicon photocell
| Cuvette Type| round 24.6 mm diameter (22 mm inside diameter)
Additional Specifications| Auto logging| 200 readings
| Display| 128 x 64 pixel B/W LCD with backlight
| Auto-off| after 15 minutes of inactivity (30 minutes before a READ
measurement)
| Battery type / Life| alkaline 1.5 V AA (3) / > 800 measurements (without
backlight)
| Environment| 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable
| Dimensions| 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0″)
| Weight| 380 g (13.4 oz.); with batteries
| Casing| IP67 rating, floating
Ordering Information| HI97115 is supplied with sample cuvette (2 pcs.); sample
cuvette cap (2 pcs.); 1.5V AA alkaline batteries (3 pcs.); instrument quality
certificate; and quick reference guide with instructions for manual download.
CAL Check standards and testing reagents sold separately
HI97115C is delivered in a rugged carrying case and is supplied with
sample cuvette (2 pcs.); sample cuvette cap (2 pcs.); marine pH reagent, 30 mL
dropper (1 pc.), Marine Alkalinity reagent, 30 mL bottle (1 pc.); Marine
Ammonia starter kit – reagent A, 30 mL dropper (1 pc.), reagent B and C
(reagent for 25 tests, each); Marine Calcium starter kit – reagent A, 30 mL
bottle (1 pc.), reagent B (reagent for 25 tests); Marine Magnesium starter kit
– reagent A, 120 mL bottle (1 pc.); Magnesium indicator reagent (for 25
tests); Marine Nitrate High Range reagent (reagent for 25 tests); Marine
Nitrite Ultra Low Range reagent (reagent for 25 tests); Marine Phosphate Ultra
Low Range reagent (reagent for 25 tests); 1 Ml graduated syringe with tip (3
pcs.); minipipette with tip (1 pc.); 3 mL Pasteur pipette (2 pcs.); 5 mL
syringe with black printing and tip (1 pc.); 5 mL syringe with blue printing
and tip (1 pc.); 1.5V AA alkaline batteries (3 pcs.); cloth for wiping
cuvettes; scissors; instrument quality certificate; and quick reference guide
with instructions for manual download. CAL Check standards sold separately.
Nitrate LR testing reagent not included. HI97115UC is ordering code for USA|
Reagents and Standards| HI97105-11 CAL Check™ standards for Marine Master
photometer – cuvette kit|
| HI758-26 marine calcium reagent – 25 tests|
| HI758U-26 marine calcium reagent – 25 tests (ordering code in the USA)|
| HI764-25 marine nitrite ULR reagent – 25 tests|
| HI772-26 marine alkalinity reagent – 25 tests|
| HI774-25 marine phosphate ULR reagent – 25 tests|
| HI780-25 marine pH Reagent – approx. 100 tests|
| HI781-25 marine nitrate LR Reagent – 25 tests|
| HI782-25 marine nitrate HR reagent – 25 tests|
| HI783-25 marine magnesium reagent – 25 tests|
| HI784-25 marine ammonia reagent – 25 tests|
Accessories| Accessories HI70436M Deionized water (230 mL)|
| HI7101419 Blue carrying case for Marine Master photometer|
| HI731318 Cloth for wiping cuvettes (4 pcs.)|
| HI731360 Glass cuvette with cap (2 pcs.)|
| HI731339P 0.1 mL minipipette|
| HI731349P Tip for 0.1 mL minipipette (10 pcs.)|
| HI740142P 1 mL graduated syringe (10 pcs.)|
| HI740143 1 mL graduated syringe (6 pcs.)|
| HI740144P Plastic tip for 5 mL syringe (10 pcs.)|
| HI740157P Plastic refilling pipette (20 pcs.)|
| HI740226 5 mL graduated syringe with black printing (1 pc.)|
| HI740237 5 mL graduated syringe with blue printing (1 pc.)|
| HI740228 Filter disc (25 pcs.)|
| HI740270 10 mL syringe with Luer Lock (1 pc.)|
| HI740271 Filter holder with Luer Lock (1 pc.)|
| HI740272 16 gauge blunt needle (6 pcs.)|
| HI740273 Marine Nitrate LR measurement kit (1 pc.)|
| HI93703-50 Cuvette cleaning solution (230 mL)|
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>