Sygonix 2633526 Thermo Hygrometer User Manual

June 9, 2024
Sygonix

Sygonix 2633526 Thermo Hygrometer User Manual

Sygonix 2633526 Thermo Hygrometer User Manual

1 Intended use

This product is an indoor thermometer and hygrometer that measures and displays the temperature and humidity level in a room. The product features wide temperature and humidity measuring ranges, digital numbers, and 3 comfort indication face icons for easy monitoring. The product is designed with a foldable stand and a hole on the back for tabletop use or wall hanging. Battery operated.
The product is intended for indoor use only. Do not use it outdoors. Contact with moisture must be avoided under all circumstances.
If you use the product for purposes other than those described, the product may be damaged. Improper use can result in short circuits, fires, injuries or other hazards.
The product complies with the statutory national and European requirements. For safety and approval purposes, you must not rebuild and/or modify the product.
Read the operating instructions carefully and store them in a safe place. Make this product available to third parties only together with the operating instructions.
All company names and product names are trademarks of their respective owners. All rights reserved.

2 Delivery content

  • Product
  • 1 x 3.0 V CR2032 button cell
  • Operating instructions

3 Latest product information

Download the latest product information at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.

4 Description of symbols

The following symbols are on the product/appliance or are used in the text:

⚠ The symbol warns of hazards that can lead to personal injury.

5 Safety instructions

⚠ Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling in this manual, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/ guarantee.

5.1 General information
  • The device is not a toy. Keep it out of the reach of children and pets.
  • Do not leave packaging material lying around carelessly. This may become dangerous playing material for children.
  • If you have questions which remain unanswered by these operating instructions, contact our technical support service or other technical personnel.
  • Maintenance, modifications and repairs must only be completed by a technician or an authorised repair centre.
5.2 Handling
  • Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.
5.3 Operation
  • If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. DO NOT attempt to repair the product yourself. Safe operation can no longer be guaranteed if the product: ­
    – is visibly damaged,
    – is no longer working properly,
    – has been stored for extended periods in poor ambient conditions or
    – has been subjected to any serious transport-related stresses.
5.4 Operating environment
  • Do not place the product under any mechanical stress.
  • Protect the device from extreme temperatures, strong jolts, flammable gases, steam and solvents.
  • Protect the product from direct sunlight.
5.5 (Rechargeable) batteries
  • Correct polarity must be observed while inserting the (rechargeable) batteries.
  • The (rechargeable) batteries should be removed from the device if it is not used for a long period of time to avoid damage through leaking. Leaking or damaged (rechargeable) batteries might cause acid burns when in contact with skin, therefore use suitable protective gloves to handle corrupted (rechargeable) batteries.
  • (Rechargeable) batteries must be kept out of reach of children. Do not leave (rechargeable) batteries lying around, as there is risk, that children or pets swallow them.
  • (Rechargeable) batteries must not be dismantled, short-circuited or thrown into fire. Never recharge nonrechargeable batteries. There is a risk of explosion!

6 Product overview

Sygonix 2633526 Thermo Hygrometer User Manual - Product
overview

  1. Temperature reading
  2. Humidity reading
  3. Comfort indication face icon

7 Inserting the battery

  1. Turn the product over.
  2. Press and slide down the battery compartment cover to open it.
  3. Insert a new battery (1x 3.0 V CR2032 button battery) into the compartment with the positive (+) side facing up.
  4. Close the cover firmly. Æ The display automatically shows the current room temperature and humidity.

8 Placement

  • Open the stand on the back of the product and place the product on a flat, dry, and stable surface.
  • A hole is available on the back for wall hanging.

9 Operation

A comfort indication face icon indicates the comfort level of the ambient conditions.

Sygonix 2633526 Thermo Hygrometer User Manual -
Operation

10 Cleaning and care

Important:
– Do not use harsh cleaning agents, rubbing alcohol or other chemical solutions. They damage the housing and can cause the product to malfunction.
– Do not rinse the product under the tap or expose to moisture.
– Do not immerse the product in water.

  • Clean the product with a soft, dry cloth.
  • Remove the battery before storing the product, or when the battery is depleted, to prevent leakage.
  • Replace the battery at least once a year to prevent leakage.

11 Disposal

11.1 Product

This symbol must appear on any electrical and electronic equipment placed on the EU market. This symbol indicates that this device should not be disposed of as unsorted municipal waste at the end of its service life. Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose of it separately from unsorted municipal waste. Spent batteries and accumulators, which are not enclosed by the WEEE, as well as lamps that can be removed from the WEEE in a non-destructive manner, must be removed by end users from the WEEE in a non-destructive manner before it is handed over to a collection point. Distributors of electrical and electronic equipment are legally obliged to provide free take-back of waste. Conrad provides the following return options free of charge (more details on our website): in our Conrad offices at the Conrad collection points at the collection points of public waste management authorities or the collection points set up by manufacturers or distributors within the meaning of the ElektroG End users are responsible for deleting personal data from the WEEE to be disposed of. It should be noted that different obligations about the return or recycling of WEEE may apply in countries outside of Germany.

11.2 (Rechargeable) batteries

Remove batteries/rechargeable batteries, if any, and dispose of them separately from the product. According to the Battery Directive, end users are legally obliged to return all spent batteries/rechargeable batteries; they must not be disposed of in the normal household waste.
Batteries/rechargeable batteries containing hazardous substances are labelled with this symbol to indicate that disposal in household waste is forbidden. The abbreviations for heavy metals in batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or wherever (rechargeable) batteries are sold. You thus fulfil your statutory obligations and contribute to environmental protection. Batteries/rechargeable batteries that are disposed of should be protected against short circuit and their exposed terminals should be covered completely with insulating tape before disposal. Even empty batteries/rechargeable batteries can contain residual energy that may cause them to swell, burst, catch fire or explode in the event of a short circuit.

12 Technical data

12.1 Power supply

Battery required………………………. 1x 3.0 V CR2032 button cell

12.2 Measuring ranges

Temperature measuring range…. -20 to +60 °C
Temperature resolution…………….. 0.1 °C
Temperature accuracy……………… ±1 °C within 0 °C to +40 °C, ±2 °C outside this range
Humidity measuring range
………. 10 – 99 % RH
Humidity resolution………………….. 1 %
Humidity accuracy …………………… ±5 % within 40 – 80 %, ±8 % outside 40 – 80 %

  • If the reading is below/above the specified range, the product will only display the minimum/ maximum measurement supported in the range.
12.3 Environment

Operating/Storage conditions……. -20 to +60 °C, 10 ­ 99 % RH (non-condensing)

12.4 Other

Dimensions (W x H x D) …………… 44 x 57 x 11 mm
Weight …………………………………… 45 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represents the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
*2633526_v2_0123_02_DS_m2L(1)