Inventor CF-WUHI-16L Comfort Dehumidifier User Manual
- June 9, 2024
- inventor
Table of Contents
- SAFETY & WARNING INSTRUCTIONS
- ELECTRICAL INFORMATION
- SOCIABLE REMARKS ENVIRONMENTAL PROTECTION
- ADDITIONAL WARNINGS FOR APPLIANCES WITH R290 REFRIGERANT
- STEPS BEFORE USE
- GETTING TO KNOW YOUR DEHUMIDIFIER
- CONTROL PANEL • FUNCTIONS
- ON-DISPLAY INDICATORS
- ΑUTOMATIC MODES
- PAIR THE DEHUMIDIFIER WITH THE INVENTOR CONTROL APPLICATION
- WATER TANK & DRAIN HOSE
- STORAGE
- FREQUENTLY ASKED QUESTIONS & TROUBLESHOOTING
- INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING REFRIGERANT R290
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Inventor CF-WUHI-16L Comfort Dehumidifier User Manual
Dear Consumer,
Congratulations on your choice!
Comfort dehumidifier series is an innovative device that ensures both dehumidifying and purifying capabilities with a premium performance. It’s dual usage and the smart dehumidification logic that the device follows, offers benefits that one would have with two dedicated units.
With Comfort series you can enjoy a healthy & comfortable living and take advantage of all the extra benefits.
Please refer to this manual, to obtain full efficiency of tdehumidifier – air purifier, through the guidelines included in the following pages and make savings via clever use of this device.
Please read all the safety instructions carefully before use and keep this instruction manual for future reference.
SAFETY & WARNING INSTRUCTIONS
For your continued safety and to reduce the risk of injury or Electric shock, please follow all the safety warnings list below.
- Please be certain the power supply is 220-240V/50Hz.
- To avoid possible electric shock, this device should not be placed near a window or in a bathroom.
- Do not operate this unit if not in a up-right position. If the device has been tipped over it must be unplugged immediately. If the unit has been placed on its side for a longer period of time, it is advised to allow the unit to stand in its up-right position for at least 2 hours prior to its operation.
- Please ensure a required clearance of 30cm on all sides
- Be certain the inlet and outlet ventilation is not obstructed at all times
- Do not spray or spill any water on this unit, as this may result in malfunction and/or possible shock.
- Do not pull the power cable with force as this may result in its damage.
- Always power off the unit prior to unplugging to avoid possible electric shock.
- Handle this device with care. The appliance must be unplugged prior to cleaning.
- Empty the water reservoir before moving the unit.
- No children under the age of 8 should be permitted to operate this electric device. Be certain, that children, handicapped people, or people with the lack of knowledge and experience, must be supervised, depending the situation, by persons responsible for their well-being and do not undertake procedures such as the cleaning or the maintenance of this device.
- It is important that adequate supervision is provided and no minors are left unattended with this device.
- This dehumidifier is for domestic and small office use only. Do not use this device for commercial, industrial or marine use, and in areas with wet surfaces such as restrooms or shower rooms. To avoid possible electric shock, this device should not be placed near a window or in a bathroom.
- This device should always be kept in an upright position to avoid any damage. Operate the unit in a flat and sturdy surface to avoid possible vibration and extra noise.
- All house exits (windows doors etc) where the dehumidifier is operating, should be shut.
- If water leakage appears within the unit, turn the unit off and disconnect the power cord.
- Before moving, unplug the device and manage to keep it in a vertical position in order to safely be transferred from one area to another.
- Be sure to empty the water whenever the water tank is full or when the device will not be used for a prolonged time.
- Always empty the water tank before storing the unit.
- If the unit is misplaced or tipped, unplug the power cord immediately. Make sure the unit is completely dry before resuming operation.
- Disconnect the device, if abnormal sounds, odors or smoke occur.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard. Never attempt to dismantle, repair or modify the device.
- Do not attempt to repair, dismantle or modify this appliance. Contact your authorized service technician for repair or maintenance of this device.
- Do not operate or stop the unit by switching the power supply on or off.
- Do not insert any objects in the unit’s air inlet and exhaust as this may cause damage to the device.
- Do not place heavy objects on the power cord. Make sure that the cord is not compressed.
- Do not place cord under any obstacles (carpets rugs or runners etc). Cord should be arranged away from areas where accidental tripping may occur.
- Casters should be able to move comfortably over any obstacle. Be extra cautious while moving over carpets, since any extra force may cause the tipping of the unit, or the spilling of any water collected in the bucket.
- Do not sit or climb on the device.
- Do not place the unit in direct sunlight or near other heating sources.
- Do not use the unit near heat sources, chemicals, radiators, flammable materials or fire.
- Do not remove the water tank while the device is in use.
- Do not use the device without the filter. Dirt and lint may clog the unit thus reducing performance.
- Do not drink or use the collected water of the unit for any purpose.
- Do not use the unit with wet hands.
Upon first use, and for proper calibration, please allow unit to operate continuously for 24 hours
UV-C lamp
This appliance contains a UV-C lamp. Read the maintenance instructions
before opening the appliance.
- Do not operate UV-C lamps outside of the appliance.
- Appliances that are obviously damaged must not be operated.
- Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in small doses, cause harm to the eyes and skin.
- Before opening doors and access panels bearing the ULTRAVIOLET RADIATION hazard symbol for the conducting USER MAINTENANCE, it is recommended to disconnect the power.
- The UV-C lamp cannot be cleaned, repaired and replaced.
- UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not be removed.
ELECTRICAL INFORMATION
The nameplate with all the electrical and technical data of this appliance, is
located on the
οpposite site of the unit.
- The appliance should be installed in accordance with national wiring regulations.
- Be sure the device is grounded properly. Proper grounding is important as it minimizes the chance of electric shock or fire. The power cord is equipped with a grounding plug for protection against electric shock hazards.
- The device must be used in a properly grounded wall socket. If the specific socket you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
- Ensure the wall socket is still accessible after the installation of the dehumidifier.
- Do not use extension cords or adapter plugs with this device.
- To avoid personal injury, always disconnect the power supply of the device, before maintenance.
Power off the dehumidifier before removing the plug.
SOCIABLE REMARKS ENVIRONMENTAL PROTECTION
Disposal of equipment no longer used:
Please follow the instructions below, when using this dehumidifier in European countries.
- This appliance requires special treatment for disposal. In the European Union, electronic equipment must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2002/96/EC of the European Parliament and Council of 27th January 2003 concerning old electrical and electronic equipment. The disposal of this unit should follow all legal requirements and should not be disposed as unsorted municipal waste. The hazardous substances can leak into the ground water supply thus entering the food chain, endangering your health and the environment.
- There are several alternative solutions for disposal:
A) Your local municipality has established free collection systems for
electronic waste.
B) Your local retailer upon purchase of a new product.
C) The manufacturer may accept the old appliance for disposal.
D) Old appliances sometimes contain valuable resources for scrap metal
dealers.
ADDITIONAL WARNINGS FOR APPLIANCES WITH R290 REFRIGERANT
(refer to the nameplate for the type of refrigerant used)
- REFER TO THE USER’S MANUAL PRIOR TO USING THIS APPLIANCE.
- R290 refrigerant complies with European environmental directives.
- Do not penetrate in any way or burn.
- The maintenance and repairs that require the assistance of qualified personnel should be carried out under the supervision of inflammable refrigerant specialists.
For detailed instructions on performing repairs on appliances which contain the refrigerant R290 please refer to Section “INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING REFRIGERANT R290”
STEPS BEFORE USE
Please refer to the electronic warranty instructions, in the last page
(English section) of this manual.
For warranty purposes, please note the SN (serial number) placed on the
device.
Installation tips
-
Do not block or restrict the airflow around the unit. Make sure the air inlet exhaust grills are not obstructed. Allow 30cm of clearance around the unit and 40cm above.
-
Place the unit in an area where the temperature levels will not fall bellow 5ºC (41ºF) There is a possibility the coils will collect frost at temperatures that are under 5ºC (41ºF), which may result in low performance. (Working conditions: 5°C-35°C, 30%RH–90%RH).
-
Ensure the filter is clean.
-
Place unit in vertical operating position and allow 2 hours before initial use in order to avoid malfunctions.
-
Before the initial operation, please check, if the water level switch, located within the water bucket area, is in the right position.
- **** Remove the filter components
- Remove the protective plastic packaging of the filter prior to initial use.
- Install the filter componenets
GETTING TO KNOW YOUR DEHUMIDIFIER
CONTROL PANEL • FUNCTIONS
POWER
By pressing the ” ****” button the dehumidifier/air purifier turns ON or OFF.
Once powered, the digital display is activated indicating the current
settings. The default operation of the device prior to first use is the
Dehumidifier in manual mode at fan speed medium.
OPERATION
By pressing the ‘’ ’ **** ’ button, three different operations can be
selected. The device will work under the operation of an Air Purifier,
Dehumidifier & Air Purifier and Dehumidifier. While changing operations the
device will make a short beep sound and the indications + will appear on the
digital display.
Air purifier
Operation as air purifier: When this operation is selected the indication will
appear on the digital display. The ambient humidity will appear on the digital
display. Under this operation no dehumidification takes place.
**** When the unit operates as an Air Purifier, only Manual mode and Sleep mode can be selected.
Dehumidifier
Operation as an dehumidifier: When this operation is selected the indications
- will appear on the digital display. The indicator will remain permanently active while the indicator will flash slowly until the compressor starts to operate. During this operation the compressor and the fan will work together to achieve the desired level of humidity in the room. Under this operation both the compressor and the fan ar operating together to reach the desired humidity level. When the set humidity level is reached, the compressor will stop running while the fan will continue until the energy saving function is automatically activated, and the appliance will enter idle mode. After the predetermined timeframe in standby mode, and if the humidity levels have increased, the device will resume dehumidification.
**** When the unit operates as an Air Purifier & Dehumidifier or Dehumidifier, Manual mode, Smart Dehumidification (SMD) mode, Sleep mode and Dry Clothes mode can be selected.
Dehumidifier & Air purifier
Operation as a dehumidifier & Air purifier: When this operation is selected
the indications + will appear on the digital display. Under this operation
both the compressor and the fan are operating together to reach the desired
humidity level. The humidity level of the room will appear on the digital
display. When the set humidity is reached the compressor will turn off and the
dehumidification process will stop. The fan will keep operating.
**** When the unit operates as an Air Purifier & Dehumidifier or Dehumidifier, Manual mode, Smart Dehumidification (SMD) mode, Sleep mode and Dry Clothes mode can be selected.
Humidity level led light
A led indicator on the unit will change color depending on the humidity level
inside the room. The humidity sensor will detect the humidity level and the
led indicator will change color based on the humidity conditions
- The blue led light indicates that the humidity level inside the room is below 55%.
- The yellow led light indicates the humidity level inside the room is between 56% – 79%.
- The red led light indicates that the humidity level inside the room is above 80%. Depending on the external conditions the ideal humidity levels fluctuate between 45% to 55%
MODE
By pressing the ‘’ ’’ button you can select between four different modes. The
available modes are: Manual mode , Smart Dehumidification (SMD) mode , Sleep
mode and Dry Clothes mode .
Manual mode
Under manual mode, the desired operating conditions can be adjusted.
- When the unit operates as an Air Purifier the fan speed may be adjusted.
- When the unit operates as a Dehumidifier & Purifier or as a Dehumidifier + both the desired fan speed and humidity level can be adjusted. The digital display will indicate ambient relative humidity levels.
Smart dehumidification mode
When the Smart Dehumidification (SMD) mode is selected the unit will initiate
the dehumidification process in order to achieve the ideal living conditions
inside the room, depending on the existing temperature and humidity levels.
The dehumidifier will set the humidity level between 45% to 55% according to
the room’s temperature thus ensuring energy efficiency and excellent room
conditions.
**** Under the Smart Dehumidification (SMD) mode the humidity level cannot be adjusted.
Sleep mode
Under sleep mode the device will silently operate with the fan at low speed.
This mode can be selected under all three operations of Comfort series.
**** When sleep mode is activated and the device is operating as a Dehumidifier & Air Purifier or as a Dehumidifier, only the humidity levels can be adjusted. The fan will remain at low speed.
Dry Clothes mode
When this mode is selected the humidity level cannot be adjusted and the fan
will operate only at high speed. After operating for approximately 2 hours the
unit will check the ambient humidity level. If the relative humidity is under
45% the dehumidification process will stop, and the fan will continue
operating for 2 hours to ensure the effective drying of clothes. If the
relative humidity is still under 45% the device will turn off.
-
If the relative humidity is higher than 45% after the first 2 hours of operation, the device will keep operating for another 1 hour before testing again the relative humidity. This process will repeat as many times needed to ensure the complete drying of the clothes.
-
The maximum operation time set by this mode is 12 hours and can be reduced depending on the room size and the dampness of the clothes.
-
If the water tank fills during the operation, before the 2 hours set time, the device will keep counting from the moment of the water full tank indication.
-
In the event of a power failure the unit will restart the drying clothes process from the beginning.
-
For better results place the device in a small room and set nearby the clothes rack. Keep doors shut and allow the dehumidifier to dry the clothes.
-
Manual wringing of the clothes is suggested.
-
Allow 30-50cm distance from the moist clothes.
HUMIDITY SET BUTTON
The humidity level can be set within a range of 40% RH (Relative Humidity) to
80% RH (Relative Humidity) and CO in 5% increments each time the relative
button is pressed. The humidity set button is only available under the
operation of Dehumidifier & Air Purifier and Dehumidifier and it can only by
applied at Manual mode and Sleep mode .
**** Under Continuous operation (CO) the device operates in a continuous manner regardless of the ambient relative humidity levels. This is suggested in cases where immediate dehumidification is necessary, such as areas or rooms that have not been occupied for an extended period of time.
FAN SPEED
By pressing the “ ” button, under the operation of Air Purifier the fan air
speed could be set to: Low (1) / Medium (2) / High (3). By pressing the “ ”
button, under the operation of Dehumidifier & Air Purifier + , the fan air
speed could be set to: Low (1) / Medium (2).
- Low: When Low Speed is selected, indicated by number ‘’01’’ on the digital display, the operation is silent, and standard functioning conditions are applied
- Medium: When Medium Speed is selected, indicated by number ‘’02’’ on the digital display, the fan is set at medium speed.
- High: When High Speed is selected, indicated by number ‘’03’’ on the digital display, the fan is set at maximum speed. This option is ideal for air purification in areas with a larger air quality issue.
- Auto: When Auto is selected, indicated by the letter A on the digital display, the fan speed will be automatically adjusted based on the humidity level inside the room. The fan speed can change between low, medium, and high.
**** The adjustment of the fan speed is not available during Sleep mode (set at low speed) and during Dry Clothes mode (set at high speed).
TIMER
Press the “ ” button to set up timer for automatically turn off.
- Any time this button is pressed, the set time is increased by 1h (hour), for auto STOP of the device. This function offers the selection of when the device will automatically turn off within a range from 1h to 9h (hours).
- Once the desired hour(s) selected, wait for 3 seconds without pressing anything and the indication of timer will appear on the digital display to confirm that timer is activated.
- For auto STOP the device should be left continue its function.
**** In the event of a power failure the timer function is not restored after power resumes
SWING LOUVER
Press the ‘’ ’’ button to activate/deactivate this feature.
- By pressing the button once, the swing louver operates in such a manner allowing a multidirectional air stream.
- By pressing the button a second time, the louver can be stopped at a desired angle. This option is selected for a direct air flow ideal for drying clothes.
ENERGY SAVING FUNCTION
The Energy Saving function is activated by default in your device. During this function the dehumidifier will turn off automatically after 12 hours of operation, regardless any timer settings. To deactivate it, press continuously for 3 seconds the buttons, ” ”, ” ”, ” ” and ” ” and the dehumidifier must be switched off.
In the event of power loss, the setting will return to its default mode and the energy saving function will be activated again.
INDICATOR LIGHT
Press the ‘’ ’’ button to activate/deactivate the digital display and the
humidity level color indicator.
- By pressing the button once, the humidity light indicator will switch off.
- By pressing the button twice, the digital display indications will switch off too, allowing the device to operate with no indicators visible.
- By pressing the button a third time, all indications will be activated again.
Muting Of The Control Panel
The sound of the control panel buttons can be muted and unmuted by pressing
simultaneously the Swing Louver and the Indicator Light buttons for 3 seconds.
When in mute status the sound alarms will remain activated.
IONIZER
Long press for 3 seconds the button to switch on/off the ionizer. Ions will be
released in the air to purify it and remove unpleasant and unhealthy
particles.
ULTRAVIOLET TYPE C (UVC)
Long press for 3 seconds the button to switch on/off the ultraviolet led type
C. The UVC led will help eliminate microorganisms such as germs, viruses,
bacteria and fungi.
CHILD LOCK
By long pressing the timer button for 3 seconds, child lock will be
activated/deactivated automatically. The indicator will remain steadily on the
display informing that child lock is active.
- **** Under Child Lock: All control buttons are deactivated and the unit will make a beeping sound each time a button is pressed.
- All control buttons are activated again, once the Child Lock is deactivated, if the unit is unplugged or if there is a power failure.
ANTIBACTERIAL FUNCTION
By long pressing the button for 3 seconds the antibacterial function will be
selected. After the completion of each operation the device will not turn off
but instead the antibacterial function will initiate. The fan will operate for
90 minutes ensure that no water will remain inside the tank that could cause
the increase the concentration of bacteria or mold, thus put your health at
risk.
The antibacterial function can be operated daily however the frequency depends on the needs of every user. When the function is selected a countdown of the 90 minutes will appear on the digital display.
ON-DISPLAY INDICATORS
P1 – AUTO DEFROST
When this unit operates in very low temperatures, possible frost may build up
internally. The device is equipped with an auto-defrost mode. In this event,
the P1 indication will activate on the digital display panel.
- Whenever the sensor which is placed on heat exchanger detects temperature under ≤0ºC, the unit enters defrost mode for 12 minutes. After 12 minutes of defrosting, the sensor checks temperature again. If temperature rises ≥2ºC, the unit exits defrost mode and defrost indicator turns off.
- This function ensures the safe operation and the efficient performance of the device.
- **** When Auto Defrost mode is on, the device may cause some noise from the refrigerant fluids flowing, that is normal.
- Do not turn off the device when auto defrost mode is on.
P2- FULL WATER TANK
When the water tank is full, removed or not placed correctly, the indication
P2 will appear on the digital control panel followed by a beeping sound.
P3 – PRE-FILTER CLEAR NOTICE
When this indicator appears on the digital display it is a reminder that the
pre-filter should be removed and cleaned properly. This reminder will appear
once 360 operational hours have been completed. Rinse the pre filter with
water and let it dry completely before replacing it on the unit.
After replacing the clean filter on the unit, long press for 3 seconds the ” ” button to reset the notice. The device will then begin to recount the 360 working hours.
P4 – HEPA FILTER REPLACEMENT REMINDER
The HEPA FILTER replacement reminder will be activated on the digital panel of
the device, once 2160 operational hours have been completed.
- When this indication appears, the HEPA filter should be replaced with a new one.
- After the replacement of the HEPA filter, the ” ” button must be pressed continuously for 3 seconds for the timer to be reset and the indication to be removed.
The timely replacement of HEPA filter, will guarantee optimal performance, clean and healthy air.
Periodical cleaning of HEPA filter every 30 days, could be applied with the use of a vacuum cleaner
Lo – Very Low Humidity
When the Room Humidity is ≤31%RH, this indication activates on the digital
control panel of the device.
- During this condition, the compressor stops and the fan keeps operating in the selected settings.
- Once room humidity ≥32%RH detected, the compressor will resume its operation in the previous settings.
Hi – Very High Humidity
When the Room Humidity is ≥91%RH this indication steadily appears in the
monitor of the device.
- During this condition, the compressor will keep operating in the selected settings.
- Once room humidity drops under ≤90%RH, the indication disappears.
ΑUTOMATIC MODES
AUTO-RESTART
The device memorizes the set operating conditions whenever power plug is
connected. In the event of a power failure the device performs Auto-Restart,
once power is restored.
In case of power failure or when the power plug unplugged from the socket, the unit will operate in default settings prior to disconnection.
**** After Auto-Restart the setting of “Timer” and of the child lock cannot be retained.
PAIR THE DEHUMIDIFIER WITH THE INVENTOR CONTROL APPLICATION
Before you start:
- Verify that the router is broadcasting at 2.4GHz.
- If the router has dual band broadcasting, verify that the network names (SSIDs) are different. For additional help, contact your router/internet provider.
- Verify that the Wi-Fi password is WPA2-PSK encrypted, and the authorization type is set to AES.
- Position the dehumidifier as close as possible to the router during the pairing process.
Step 1 : Download and install the “Inventor Control” application from the Google Play Store or IOS App Store.
Step 2: Select “Register” to create a new account or “Log in with Existing Account”
Step 3 : To add the device, select “My appliances” and press “+” on the
top right corner, or “Add Device” and select “Dehumidifier”.
Notes:
Carefully read the Privacy Policy and select “Agree” to continue.
To create an account, an email or a mobile number are required. Enter the code that you received in your registered email or phone number, in the “Enter Verification Code” field to proceed with the pairing process.
Step 4 : Plug in the dehumidifier to a power supply and turn it on. Press
the Mode button on the device for 3 seconds until the pairing indication
appears on the display. Press Confirm to proceed
Step 5 : Select the Wi-Fi Network and enter the password. Press Confirm
to proceed. The pairing process may take some time.
Note:
When the dehumidifier is successfully connected and during the remote control
the wireless symbol will appear on the led display
Troubleshooting:
If the pairing process is not successful:
- Verify that the router is broadcasting at 2.4GHz.
- If the router has dual band broadcasting, verify that the network names (SSIDs) are different. For additional help, contact your router/internet provider.
- Verify that the Wi-Fi password is WPA2-PSK encrypted, and the authorization type is set to AES.
- Position the dehumidifier as close as possible to the router during the pairing process.
- Power off the router, the dehumidifier, and the device (tablet or mobile) and allow 5 minutes.
- Restart the pairing process from Step 2.
- If the pairing is not successful, repeat the process with a different smart device (tablet or mobile).
- Contact Inventor’s After Sales Dept
WATER TANK & DRAIN HOSE
There are two ways to remove collected water. Before proceeding ensure that you have switched off and unplugged the unit
-
Usage of the water tank
When unit is OFF and the tank of the dehumidifier is full, the full indicator will be lit. Additionally, when the unit is on and the tank is full, indicator will illuminate, and the unit will automatically stop operating.- Carefully remove the bucket. Slowly slide the water tank outwards to the accumulated water does not overflow.
- Lift the plastic lid, in order to remove the accumulated water from the tank, once the water is emptied close the plastic lid once again, and place the tank securely and properly into the device.
- **** When the water tank is re-installed the unit will automatically restart.
- When you remove the tank, do not touch any parts inside the unit, as you may damage the device.
- Be sure to gently place the tank into the dehumidifier.
- Do not drink or use the collected water from the device.
- Wipe any excess water on, or in, the unit when removing the tank.
-
Continuous draining
Water automatically can be emptied into a floor drain by attaching the unit with a water hose.- Remove the rubber plug located opposite the unit. Insert the water hose into the drain outlet and make sure all connections are firmly tightened in order to avoid any possible leaks.
- The dehumidifier – air purifier, should be placed on a flat surface in an upright position.
- Lead the water hose towards a suitable drainage facility and be certain that the water flows naturally. For correct drainage, make sure the hose stays below the level of the drain hose outlet.
**** When the continuous drainage feature is not being used, remove the drain hose from the drain hose outlet and re-install the rubber cap.
Maintenance & Cleaning of your air filter
The air filter of the unit collects dust contained in the air. The buildup of dust reduces the efficiency of the unit. To prevent the dust from clogging up the unit always use it with the air filter in place.
Always clean the air filter every 2 weeks. If the unit operates in a dusty atmosphere clean the air filter more often
- Remove the air filter.
- Clean the air filter with a vacuum cleaner. lf the air filter is very dirty, you can wash it in warm water (never use hot or soapy water). Make sure that the air filter is dry and refitted correctly. Do not bend the filter and ensure it is fitted before operating the unit.
Cleaning the tank:
Remove the plastic protective lid and partially fill the tank with clean water
adding a minimal amount of mild detergent. Clean thoroughly empty and rinse.
- Clean the tank every 2 weeks to prevent mold, mildew and bacteria growth.
- After cleaning, make sure the tank is placed back securely for the dehumidifier to operate.
Cleaning the unit
- Clean the unit by using a damp sponge, and dry it with a clean, soft cloth.
- Never use alcohol or any product containing solvents.
- Do not immerse the unit in water.
NEVER USE THE DEVICE WITHOUT THE AIR FILTER
STORAGE
When unit is inactive for an extended period of time, please make sure you
follow the
instructions below, for the appropriate storage of your appliance:
- Turn unit off allowing one day before storage.
- Remove drain hose (if attached).
- Clean the removable parts of the device, water tank and air filter.
- Position and secure the power cord with its band opposite the dehumidifier.
- Cover the device.
- Store the dehumidifier. in upright position, in a dry, well ventilated area and avoid direct sunlight.
FREQUENTLY ASKED QUESTIONS & TROUBLESHOOTING
Are dehumidifiers costly?
For about the first month of use, the dehumidifier operates intensively. This will gradually decrease within time, since the dehumidifier will have been calibrated in its working environment. Condensed households may sometime be significantly expensive to heat. The use of a dehumidifier may lower energy costs
Where should the dehumidifier be placed ideally?
For optimal results, it is suggested that the dehumidifier is placed in a central area. Doors within the household should be open in order for the dehumidifier to enhance its operation.
Can the filter be replaced by another HEPA type filter?
The dehumidifier’s filter cannot be replaced by any other type of filter since it is specifically designed to operate with this unit.
Which is the appropriate room humidity level?
Maintaining a proper home humidity level is essential for your well-being and that of your household. Extreme fluctuations cause adverse effects on both; low humidity may cause respiratory problems and damage on wooden doors, windows, and furniture, and make you vulnerable to electric shocks due to increased static electricity. Onthe other hand, high humidity may promote mold growth, serving as breeding grounds for various bacteria and resulting in poor health and also a damaged home. The ideal humidity levels fluctuate between 45% to 55%.
Why does condensation persist on windows even with dehumidifier’s use?
When the desired humidity level is reached, there is a possibility of partial humidity formation on windows. This occurs due to the temperature variation between the window and the external weather conditions.
- Operating the dehumidifier should significantly reduce condensation formation on windows.
Why am I not able to set the desired humidity level by using the control panel?
In order to manually adjust the desired humidity level, ensure that the unit operates as a Dehumidifier & Air Purifier and the indications + are activated. The humidity can be adjusted only under Manual and Night Mode
How much time is needed to dry my clothes?
The exact time needed to dry clothes depend on many factors, the room’s temperature, the humidity level, the moisture of the clothes etc., so there is no standard time since of these variable factors mentioned above.
Poor performance of dehumidifying
- Did not operating enough time to remove the moisture.
- Make sure there are obstacles blocking air inlet/air outlet.
- The ambient humidity may be lower than the humidity setting.
- Check that all doors, windows and other openings are securely closed.
- Room temperature is too low, below 5ºC(41ºF).
The dehumidifier is not a chilling device. What could be the cause of cold airbeing extracted?
The dehumidifier operates by intaking condensed air removing any moisture and sending it back in the area it operates. If you are standing near the dehumidifier while operating you may feel that the air coming out of the fan is cooler due to the diffusion. In reality, it is at the same roomtemperature but with less humidity
The unit does not start
- Make sure the dehumidifier’s plug is placed completely into the socket.
- Check the house fuse/circuit breaker box.
- Check whether the power cord is damaged.
- Check the water bucket, if it is full, empty it.
- Check if the dehumidifier has reached its preset level.
- Make sure the water bucket is positioned properly.
- Room temperature is lower or higher than the advised operational range.
- Check whether the humidity level has been set in high levels.
Dehumidifier does not dry the air as efficient
- Make sure that the dehumidifier has been operating enough time to remove the moisture.
- Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier.
- The humidity selector may not be set low enough.
- Make sure you have cleaned the filter as suggested. Clogged filter may result in reduced performance.
- All house exits (windows doors etc) where the dehumidifier is operating, should be shut.
- Room temperature is below the advised operational range.
- There is a kerosene heater or something giving off water vapor in the room.
- The room that the device is placed is bigger than suggested.
- The humidity level is too high.
The unit makes a loud noise when operating
- The air filter is clogged.
- The device is tilted instead of being in an upright position.
- The floor surface is not flat.
Frost build up on coils
- This is normal. This unit is supplied with an Auto defrost feature.
Drain hose water leakage
- Check the correct installation of the drain hose.
- Check for any blockage or damage of the drain hose.
Understanding Error code indications
C1 – Temperature humidity sensor or NTC failure
C2 – Temperature sensor failure
C8 – Refrigerant leakage or NTC ≥40°C
In the event of any of the above-mentioned errors, all buttons are unavailable, except for the “POWER” button so that the device can be turned off. After powering off, unplug the device for 10minutes to reset. When device is turned back on check if the error persists. In case the error persists, the unit should remain turned off and unplugged. Contact the manufacturer or a qualified technician for service.
INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING REFRIGERANT R290
-
Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work in the system. Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed. -
General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material. -
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. nonspeaking, adequately sealed or intrinsically safe. -
Presence of fire extinguisher
If any work is to be conducted on the refrigeration equipment or amy associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. -
No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks.”No Smoking” signs shall be displayed. -
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. -
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following check shall be applied to installations using flammable refrigerants: –the charge size is in accordance with the room size within which the refrigerant containing parts are installed; –the ventilation machinery and outlets are operating adequately and are not obstructed; -
Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used . This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: –that capacitors are discharged; this shall be done in a safe manner to avoid possibility of sparking; –that there no live electrical components and wring are exposed while charging, recovering or purging the system; –that there is continuity of earth bonding. -
Repairs to sealed components
During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation. Particular attention shall be paid to the following to ensure that by working inelectrical components, the casing is not altered in such a way that level of protection is affected. This shall include damage to cables, excessive numble of connection, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications,
NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them. -
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. -
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual leaks. A halide torch (or any other detector using a naked flame) shall not be used -
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used. -
Leak detection methods
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibrated.(Detection equipment shall be calibrated in a refrigerant- free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas(25% maximum )is confirmed . Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe work. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system both before and during the brazing process. -
Removal and evacuation
When breaking into the refrigerant circuit to make repairs- or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to: remove refrigerant; purge the circuit with inert gas; evacuate; purge again with inert gas; open the circuit by cutting or brazing; The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be “flushed’ with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This processing shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available. -
Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed. -Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- label the system when charging is complete (if not already)
- Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system is shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
-
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken is case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
a) become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure ensure that; Mechanical handling equipment is available and being used correctly; the recovery process is supervised at all times by a competent person; recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible , make a manifold so that refrigerant can be removed from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer’s instructions.
h) Do not overfill cylinders. (No more than 80% volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. -
Labeling
Equipment shall be labeled stating that it has been de-commissioned and emptied of
refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. -
Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant(i.e special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and , if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer of in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior toreturning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. When oil drained form a system, it shall be carried out safely. -
Transport of equipment containing flammable refrigerants
Determined by local regulations. -
Discarded appliances supplies flammable refrigerants
See National Regulations. -
Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions. -
Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
All the pictures in the manual are for explanatory purposes only. The actual shape of the unit you purchased may be slightly different, but the operations and functions are the same. The company may not be held responsible for any misprinted information. The design and the specifications of the product for reasons, such as product improvement, are subject to change without any prior notice.
Please consult with the manufacturer at +30 211 300 3300 or with the Sales agency for further details. Any future updates to the manual will be uploaded to the service website, and it is advised to always check for the latest version.
Scan here to download the latest version of this manual.
www.inventorappliances.com/manuals
References
- Κλιματιστικά Inverter WiFi, Ψυγεία, Αφυγραντήρες, Air Conditioners - Inventor
- Biblioteca media - Inventor
- Αρχεία και Υποστήριξη - Inventor
- Inventor Appliances User Manuals - Inventor appliances
- Inventor
- 10 χρόνια εγγύηση κλιματιστικών Inventor - Inventor
- Inventor
- 2 Year Warranty Card Registration - Inventor appliances
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>