General

Scope
This specification defines the performance characteristics of a single phase 850 watts, 5output power supply . This specification also defines worldwide safety and electromagnetic compatibility requirements for the power supply which is intended for use in computer products.

Input Characteristics

Input Voltage

Max. Input Current Measuring Range
     100-264 Vrms    12~6A

Input Frequency

Nominal Frequency Frequency Variation Range
50-60 Hz 47 Hz to 63 Hz

The power supply must operate at above frequency with 90-264VACrms input voltage range.

Max. Input AC Current

Max. Input Current Measuring Range
12-6A 100-164

4 Inrush Current

The power supply must meet inrush requirements for any rated AC voltage,
during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and over the specified temperature range. The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device).

Efficiency

Efficiency versus Load for ENERGY STAR*, at 115V/60Hz and 230V/50Hz

Loading| Low Load(2%)| Light Load(20%)| Typical Load(50%)| Full Load(100%)| PFC@50%Load
---|---|---|---|---|---
Minimum Efficiency| 60%| 90%| 92%| 89%≥0.9|

Output characteristics

Normal Operation Output

Normal Operation Output

OutputVoltage LoadMIN RangeMAX TotalRegulation Ripple & NoiseP-P Max.
+5V 0.0A 20A ±5% 40mV
+12V 0.0A 70.8A +5% /-7% 80mV
–12V 0.0A 0.3A ±10% 80mV
+5Vs 0.0A 3.0A ±5% 40mV
+3.3V 0.0A 20A ±5% 40mV
  • Maximum continuous total DC output power should not exceed 850W
  • Maximum continuous combined load on +3.3VDC and +5VDC outputsshall not exceed 100W.
  • Maximum combined load on +12V output rails shall not exceed 850W

NOTE:
Noise test should be measured with 20 MHz bandwidth frequency oscilloscope. The output terminal shall add a tantalum capacitor of 10uF in parallel with a ceramic capacitor of 0.1uF.

Remote On/Off Controlled mode

The PSON# signal is required to remotely turn on/off the power supply, PSON# is an active low signal that turns on the output power rails. When this is not pulled low by the system, or left open, the outputs (except the +5VSB) turn off. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply.

TTL level: “H” 2.0 V – 5.25 V “L” 0.0 V – 1.0 V

Regulation

The cross regulation defined as follows, the output regulation should be within the specified range.

Load +5V +3.3V +12V -12V +5Vsb
Low Load 0.21A 0.21A 1.24A 0.01A 0.05A
Light Load 2.11A 2.11A 12.43A 0.05A 0.53A
Typical Load 5.29A 5.29A 31.08A 0.13A 1.32A
Full Load 10.57A 10.57A 62.16A 0.26A 2.63A

Rise Time
DC output rise time is less than 20 mS at nominal line and full load.

+5V DC / +3.3V DC Power Sequencing
The +12V and +5V output levels must be equal to or greater than the +3.3V output at all times during power-up and normal operation. The time between any output of + 12V and +5V reaching its minimum in-regulation level and +3.3V reaching its minimum in-regulation level must be ≤ 20mS.

Hold-up Time
PG output maintains at least 16mS is 40% 1oad after power off which hold within para 3.1 under 115V/60Hz and 230V/50Hz condition.

5VSB
5VSB is requierd for the implementation of PS-ON described above. 5VSB is a tandby voltage that may be used to power circuits that require power input during the powered-down state of all power rails. The 5 VSB pin should deliver 5V ± 5% at a minimum of 3.0 A for PC board circuits to operate. Conversely, PC board should draw no more than 3.0A maximum form this pin. This power may be used to operate circuits such as soft power control.

PG-OK
PG-OK is a power good signal and should be asserted high by power supply to indicate that the +5 VDC and +3.3 VDC outputs are above the under-voltage
thresholds of the power supply. When this signal is asserted high, there should be sufficient mains energy stored by the converter to guarantee continuous
power operation within specification. Conversely, when either the +5VDC or the +3.3VDC output voltage falls below the under-voltage threshold, or when mains power has been removed for a time sufficiently long so that power supply operation is no longer guaranteed, PG-OK should be deasserted to a low state. See Figure 1 for a representation of the timing characteristics of the PG-OK, PS-ON, and germane power rail signals.

3.3V Sense.
A default 3.3V sense line should be implemented pin 13 of the connector.

Capacitive Load
The power supply should be able to power up and operate normally with the
following capacitances simultaneously present on the DC outputs.

Output Capacitive load (uF)
+5V 3300
+12V 3300
+3.3V 3300
-12V 330
+5VSB 3300

Support PCIE 12VHPWR Power

*PCI Express 12VHPWR Connector Power Limits**

Initial Permitted Power at System Power Up| Maximum Sustain Power after Software Configuration| Support type
---|---|---
375 W| 600 W|
225 W| 450 W|
150 W| 300 W|
100 W| 150 W|

PCIe* AIC and PSU Power Budget used for Peak Power Excursion

% of PSU Rated Size PSU≤450 Watts & PSUswithout 12VHPWR Connector| Power Excursion % of PSU Rated SizePSU > 450 Watts & 12VHPWR Connectorpresent| Time for Power Excursion (TE)| Testing Duty Cycle
---|---|---|---
100%| 100%| Infinite|
110%| 120%| 100ms| 50%
135%| 160%| 10ms| 25%
145%| 180%| 1ms| 20%
150%| 200%| 100 us| 10%

Protection

Input Protection
In primary circuit of the power supply , a protected fuse is inserted. Only internal
fault of the power supply will cause the fuse blown. Any overload or short circuitc at DC output will keep from fuse brown or fire hazard.

Output Protection
Under voltage protection
The +12V/+5V/+3.3V DC output are protected against the under voltage condition range value can’t be exceed 10.3~11.0V at 12V terminal and 3.3~3.7V at 5V, 2.0~2.4V at 3.3V.

Over Voltage Protection
The +12V/+5V/+3.3V DC output are protected against the over voltage condition. Maximum value can’t be over 15.6V at 12V terminal and 7.0V at 5V, 4.3V at 3.3V.

Over Power Protection
The power supply can be used electronic circuit to limit the output current against exceeding 30-70% of surge output power or protected against excessive power delivery since short circuit of any output or over total power at high line.

Short Circuit Protection
Short circuit placed on +5V,+12V,+3.3V,-12Vwill latch off. +5VSB will auto- recovery.

Over Current Protection
Current protection should be designed to limit the current to operate within safe operating conditions.Over current protection schemes where only the voltage output that experiences the over current event is shut off may be adequate to maintain safe operation of the power supply and the system; however, damage to the motherboard or other system components may occur. The recommended over current protection scheme is for the power supply to latch into the shutdown state. The setting of over currentprotection for each output rail is as following. +5V is less than or equal to 22~30A.. +3.3V is less than or equal to 22~30A. +12V is less than or equal to 92~120A.

Over Temperature Protection
This power supply includes an over-temperature protection sensor, which can trip and shut down the power supply at 75℃ ±10℃

Start Stability

No Load Start
When power is applied to PSU with no load connected or under minimum load connected, neither damage to power supply nor hazards to users will occur.

Cold Start
The power supply shall operate properly when first applied at normal input voltage and or so maximum load after 4 hours storage in 0℃ environment.

Environments

Temperature and Humidity

Operating

  • Temperature: 0 to 50 °C
  • Relative Humidity:   20 to 90 %

Storage

  • Temperature: -40 to 70 °C
  • Relative Humidity:   20 to 95 % noncondensing

Altitude
The power supply can operate normally at any altitude between 0 to 10000 feet.

Vibration and Shock

Sweep and resonance search for each of X,Y,Z, axis at the sweep. RATE of 1/OCTAVE/Min.

Frequency Duration Amplitude
5-55-10 Hz 30 minutes 0.35mm

Conducted EMI

CE.FCC

Product Safety

Safety Requirement
TUV,CB .UL/c-UL

Leakage Current
The AC leakage current is less than 3.5mA when the power supply connect to 264Vac/50Hz .

Insulation Resistance
The insulation resistance should be not less than 30M ohm after applying of 500VDC for 1 minute.

Dielectric Voltage Withstand
The power supply shall withstand for 1 minute without breakdown the application of a 60Hz 1500V AC voltage applied between both input line and chassis (20mA DC cut-off current). Main transformer shall similarly withstand 3000Vac applied between both primary and secondary windings for a minimum of one minute.

Power Good Signal

A TTL compatible signal for the purpose of initiating an orderly start-up procedure under normal input operating conditions. During power up, this signal is asserted ( low ) until +5V is under regulation and AC reaches min. line specification range. After all voltage are going appropriate level, the system may have a turn on delay of 100mS, but no greater than 250mS. During power off the signal should go to low level before +5V is out of regulation. The low level is 0 to 0.8V and high level is 4.75 to 5.25V. The ” Power Good “signal can drive up to 6 standard TTL loads.

Figure 1 Time Diagram
Time Diagram

  • T0 : AC Turn on time ( 2S. Max.)
  • T1 : Turn on time ( 200mS. Max.)
  • T2 : Rise time ( 0.2~20 mS.)
  • T3 : PWR_OK delay ( 100~ 250 mS )
  • T4 : PWR_OK rise time (10mS. Max.)
  • T5 : AC loss to PWR_OK hold-uptime (16mS Min 40% Load )
  • T6 : PWR_OK inactive to DC lossdelay (1 mS Min )
  • Power on-off cycle :

When the power supply is turned off for a minimum of 2.0 sec. and turn on again, the power good signal will be asserted.

MTBF

The MTBF of the power should be 100,000 hours min.

Burn-In

Input Voltage
Applying 230Vac
The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :2005standard of class D, test at 230Vac 50Hz.

Power Factor

The power supply with active power factor correction, and meet the EN61000-3-2 standards, The power factor is greater than 0.95 at 230V/50Hz, Max. load.

Fanless Function

  1. The fan does not turn when the load is less than 110W, but the fan will start to cool down when the temperature inside the machine exceeds the safe range.
  2.  when the load exceeds 200W, the fan starts.
  3. an Delay Mode PS_ON# is turned off, the fan stops working 2 minute later.

Mechanical Specification

Outline Dimension

125mm (W) X 63.5mm (H) X100mm( D)

POWER SUPPLY CONNECTOR OVERUSE DEFINITION

Power Supply

Power supply connector overuse definition

A single PCIe 8pin cable and connector’s maximum current rating is 12.5A, which is 150W (+12V x 12.5A). So SilverStone’s warranty will not cover damages or malfunction resulting from the use of a graphics card or expansion card with a single PCIe 8pin connector that exceeds standard 225W total power draw (150W from PCIe 8pin connector + 75W from PCIe motherboard slot). Similarly, a graphics card or expansion card with dual PCIe 8pin connectors that exceed 375W total power draw (300W from two PCIe 8pin connectors + 75W from PCIe motherboard slot) will also not be covered under warranty

Peripheral (molex) or SATA connector’s maximum current rating is 5A, which is 60W (+12V x 5A) or 25W (+5V x 5A). Please ensure connected devices are operating under these limits. SilverStone’s warranty will not cover damages or malfunction resulting from usages exceeding these connectors and their associated cables.

24pin motherboard connector’s maximum current rating for its dual +12V metal pins are 5A each, which totals 120W (+12V x 5A x 2). Please ensure +12V drawing devices connected to the motherboard are operating under these limits. SilverStone’s warranty will not cover damages or malfunction resulting from usages exceeding these connectors and their associated cables.

This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Model (safety certification):SST-SX0850MCPT-A The equipment a Class | Switching Power Supply intended to use for information technology equipment or Audio and Video equipment.