ZENDURE SuperBase Pro 1500 Portable Power Station User Guide

June 9, 2024
ZENDURE

SuperBase Pro 1500
User Manual

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station
-

Read all safety guidelines, warnings and other product information in this manual carefully, and read any labels or stickers attached to the product before using.
Users take full responsibility for the safe usage and operation of this product.
Familiarize yourself with relevant regulations in your area. You are solely responsible for being aware of all relevant regulations and using Zendure products in a way that is compliant.
Keep this manual for future reference.

Specifications

General

Weight| z 41.451bs /18.8kg
Dimensions| 17.5 x 10.5 x 13.8in / 446 x 276 x 352mm
Capacity| 1,440Wh (30Ah/48V)
Wireless Type| Wi-Fi
Cell Network & GPS| Supported
Outputs
6AC Ports| Pure Sine Wave, rated 2,000W (surge 4,000W),
100-120V-50/60Hz (US, JP version)
or 220-240V-50/60Hz (Other versions)
4
USB-C Ports| USB-C1/2: 5-20V, 100W Max Each
USB-C3/4: 5-12V, 20W Max Total
1*Car Charger Port| 13.6V **10A, 136W Max
3*DC5521 Output Ports| 13.6V **10A, 136W Max Total

  • The EU version has 4 AC Outlets %#136W refers to the combined maximum output power of the Car Outlet and the DC5521 ports together.

Inputs

AC Charge| 1,800W Max,(1500W,JP)
100-120V-50/60Hz (US, JP version)
or 220-240V-50/60Hz (Other versions)
Solar Charge| 12-60Vmp 10A DC, 600W Max via XT60 input
60-160Vmp 11A DC, 1,800W Max via AC input
Total AC+DC MPPT,2400W
Car Charge| Supports 12V/24V= 10A Battery

SuperBase Pro cannot support AC output while recharing by solar charge via AC Input port.

Battery

Cell Chemistry| LiFePO4
Warranty| 2 years
Cycle Life| 6,000 cycles
Temperature
Optimal Operating Temperature| 59°F to 95°F (15°C to 35°C)
Discharge Temperature| -4°F to 140°F (-20°C to 40°C)
Charge Temperature| 32°F to 110°F (0°C to 40°C)
Storage Temperature| 32°F to 110°F (0°C to 45°C)

*The temperature mentioned above i s allambient temperature

Safety Guidelines

2.1 Usage

  1. 1. .Store product in a cool and dry place.
    1. Do not dispose of the product in heat or fire.
  2. Do not expose to moisture or submerge it in liquid.

    1. Do not use around strong static electricity or magnetic fields.
  3. Do not disassemble the product. Consult official Zendure channels when service or repairis required. Incorrect disassembly or reassembly may result in arisko f fire or injury to persons.

    1. When using the product, please strictly follow the operating environment temperature range specified in the user manual. If the temperature is too high, it may result in a fire or explosion; if the temperature i s too low , the product performance may be severely reduced, or the product may cease to work.
  4. Do not block or obstruct the fan during use or place the product in an unventilated or dusty area.

    1. Ensure the product i s not hit, dropped, or heavily vibrated. Securely fasten the product when transporting to avoid damage. If severely damaged, turn off the power source immediately and discontinue using the product.
  5. If you accidentally drop the product into water during use, please place it in a safe open area, and stay away from it until it i s completely dry. The dried product should not be used again and should be properly disposed o f according to the Disposal Guide section o f this manual.

    1. Only clean the ports with a dry cloth.
  6. .Place on aflat surface to keep the product from falling over. If the product is overturned and severely damaged, turn it off immediately, place the battery in an open area, keep it away from people and combustibles, and dispose of it in accordance w ithlocal laws and regulations.

  7. Keep out o f reach o f children and pets.

2.2 Disposal Guide

  1. 1. When possible, fully discharge the battery before disposing of it. Consult your local laws on battery recycling and disposal.
  2. If the battery cannot be fully discharged due to product failure, contact a professional battery recycling company for further processing.

  3. When disposing of secondary cells or batteries, keep cells or batteries of different electrochemical systems separate from each other.

Important Tips

 It is recommended to use this product in an environment of 15°C-35°C, away from water, fire and other sharp objects.
 For long-term storage, please charge and discharge this product once every 3 months. That is, discharge the product to 30% first, and then recharge it to 60%.
 For safety reasons, do not store this product i n an environment above 45°C o r below 0°C for along time.
 If the power of this product is lower than 1% after using, please charge it to 60% before storing it. Because the battery is left idle for along time when the power is seriously insufficient, it will cause irreversible damage to the battery and shorten the service life of the product.
 Do not disassemble the product. When service or repair is required, please consult official Zendure channels. Improper disassembly or reassembly may result in a risk of fire or personal injury.

Getting Started

4.1 What’s in the Box

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
2

4.2 Interface

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
3

4.3 Display

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
4

Power Button &Display ON/OFF

  • * Press 1 second to tum ON SBP1500,long press 3 seconds to turn OFF SBP1500.
  • Short press to turn OFF the Display and Ambient Light.

AC Power Button

  • Short press toturn ON/OFF AC Output.
  • lone press 3 seconds to change frequency(60Hz/50Hz,Applicable to the Kanto and Kansal reglons of Jp).

DC Power Button

  • Short press to turn ON/OFF DC Output(USB port for direct output,not controlled).
  • long press 3 seconds to turn ON/OFF 4G .

WI-FI Reset Button

  • long press 3 seconds to start WIFI connecting.
  • Short press to disconnect WIFI.

SBP1500 Reset

  • long press (Power button+AC button+DC button)5 seconds to Reset the device Indicator Tips
  • The device I s really turned off when the power light go out, so when turn off the device, please check if the power light go out.
  • If using UPS, the AC input must be connected to the grid and the AC output must be on. Both Power and AC indicators must be on at the same time.
  • Wifi indicator starts flashing and the device enters wifi connecting mode,after completing wifi connection, the indicator keeping green light and offline going out.
  • DC5521/Car charger output, DC Output butten must be on, the indicator must be on.

Display Tips

  • * rower Ring: The ring fills up as the battery i s charging. If the product is at 5% charge or less, the ring will lash.
    • WI-FI Status: Long press the WI-FI button 3s, the WI-FI Icon flashing, and it start connecting to Wi-Fi, after a successful connection, the icon remaining on. If there is no network available, the icon will keep flashing 5 min then going out.
    • Cell Network: Long press the DC button 3s , the cell network icon flashing, start connecting to a mobile network,after a successful connection, the icon remaining on. If there is no network available, the icon will keep flashing 5 min then golng out.

4.4 General Product Usage

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
5

Press for 1s to Turn On, Long Press for 3s to Turn Off

4.41 Startup, Power Off, Display On
– Press the Power Button for 1 second to turn on the product; the Display will light up and the power ring indicator will display.
– The Display will automatically turn off after 1 minute of idle operation. You can change this through the Zendure App, When the product senses any load change or
other changes to its operations, the Display will automatically light up.
– T o power off the product, press and hold the Power Button for 3 seconds.
– The default product standby time is 1 hour. With other buttons turned off and no other load access for 1 hour, the product will automatically s h u t down, The standby
time can be set in the Zendure App.
4.42 Zendure App
The Zendure App gives users the ability to control and monitor their Zendure power stations remotely.
Read the Zendure App user guide and access the download link here: https://zendure.com/pages/download-center

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station -
qr

https://app.zendure.com/download

Privacy Policy
By using Zendure Products, Applications and Services, you consent to the Zendure Terms of Use and Privacy Policy, which you can access via the “About” section o f the “User” page in the Zendure App.
*Add device and Update to the latest firmware version*
Using the device for the first time, you need to update the firmware via the Zendure App.
More information, Please check the Zendure App user guide.
Battery Capacity Calibration**
Using the device for the first time, you need to calibrate the battery capacity, as follows:
First discharge the left power of the product, and then let the device charge to 100%, then you have completed the capacity calibration.
*Standby Time Setting
The default product standby time is 1 hour. With other buttons turned off and no other load access for 1 hour, the product will automatically shut down. The standby time can be set in the Zendure App. For energy saving, keep SuperBase Pro1500 power off when the device is not in use.
4.43. Press “DC ON/OFF” button and “AC ON/OFF” button to enjoy the equipment using

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
7

Tips:

  • The DC Power button button only controls 12V DC output,that is, 3*5521 and Car output,not including USB-type C port which can output directly.
    • If the AC or DC power is on, the device will always be in standby , for energy saving, keep the AC and DC power off when the device is not i n use.
      • If the load power is less than 25W and the DC or AC power button is not turned on, the SuperBase pro 1500 will default to without load. After 1 hour of standby, it will automatically shut down to save power.

4.5 AC Recharging
Zendure’s GridFlow fast charge technology is specifically for AC recharging, offering 1,800W of maximum input power. This limit can be modified in the Zendure app. In
case o f unusual situations where the AC input current remains higher than 20A , the AC input port will initiate a self-protection function, and the Overload Switch on the
product will automatically pop up. After confirming that there i s no product failure, you can press the Overload Switch t o resume charging.

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
8

Tips:

  • * You can set the charging power in the Zendure App.
    • Please use the AC Charging Cable included in the package for fastcharging. Do not use other cables to charge. Plug directly into an AC wall outlet and make sure that the wall outlet and circuit are rated for more than 15A. Otherwise, reduce the unit charging speed via the Zendure App. Zendure assumes no responsibility for any consequences of product misuse, including but not limited t o charging with an unsuitable wall outlet, circuit, or power cable.
    • AC GridFlow charging cannot be stopped via the Zendure App, if you need tostop it, please unplug it manually.

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
9

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
10

4.6 Solar Recharging
Users can connect solar panels in series as shown in the figure to recharge the product. The product supports 12-160Vmp DC input, 11A max current, and 1,800W max charging power.
Tips:

  • SBP1500 not support Dual MPPT
    (AC 1800W+XT60 600W,chargeing a t the same time,the battery only support 1800W input)

4.7 Car Recharging
Users can recharge the product through the car cigarette lighter socket.
Tips:

  • Please recharge using the car charger only while the car’s engine i s running, to avoid draining your car’s battery.
  • In addition, please make sure that the cigarette lighter port of the Car Outlet and the Car Charger Input Cable (not included ) are in good condition. Zendure assumes no
    responsibility for any loss, damage, or injuries caused by misuse.

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
11

4.8 Using Cell Network & GPS
Tips:

  • * Only long press the DC button 3s to activate the 4G connection, and the GPS synchronously.Cell Network & GPS cannot be deactivated through Zendure APP.
    • Cell Network & GPS recommended use in outdoors where without WIFI but with strong GPS satellite signal.

You can manually turn off the cell network or GPS services in the Zendure App.
The signal strength of cell networks and GPS services can vary. If you have any questions, please contact the Zendure team for support.
4.9 AmpUp Mode
With Zendure AmpUp technology, the product can power a 3,000W max device while the rated output power remains 2,000W, avoiding operation failure due to overload
protection.
You can turn on AmpUp Mode in the Zendure App.
AmpUp Tips:

  1. 1. AmpUp is not available when the AC output is turned on in a recharging state (in bypass mode).
  2. AmpUp is not applicable for all electrical appliances; it’s incompatible with appliances that have strict voltage requirements and a rated power over 2,000W.
    Appliances with voltage protection (such as precise instruments) are not supported.
    AmpUp mode is more suitable for heating devices. When using AmpUp with an untested device, please monitor its performance for any irregularities.

4.10 Offline UPS
This product supports 13ms offline UPS.
When you connect the grid power to the AC Input Port of the product through an AC cable, you can power electrical devices through the AC Output Port (AC power will
come from the grid and not the power station in this situation).
In case of a sudden blackout, the product can automatically switch to the battery- powered supply mode within 13ms. As an offline UPS, this function does not support Oms switching.
Please do not connect the product to any device that requires Oms UPS, such as data servers and workstations.
Please test and confirm compatibility before using the product as a UPS.
We recommend that you only charge one device at a time and avoid using multiple devices simultaneously to avoid triggering overload protection. Zendure assumes no respon sibility for any device failures or data losses caused by misuse of this product.

ZENDURE ZDSBP1500 SuperBase Pro 1500 Portable Power Station - fig
12

Tips:

  • If wanting to use Offline UPS ,Please keep the grid power connecting to the AC Input Port with an AC cable,the AC power button is on and connect to the device you need SBP1500 to be powered.

4.11 Sleep Mode

  • * With Sleep Mode activated, SuperBase Pro will reduce the input power, deactivate the ambient light, and turn off all sounds,
    • You can turn on Sleep Mode in the Zendure App.
    • Any changes to input power setting, light, sound or standby time of the display will deactivate Sleep Mode.

FAQs

1. What are the charging methods for SuperBase Pro 15007
**** – SuperBase Pro 1500 supports 5 charging methods.
– Household AC socket (15A max);
– Solar panel AC port charging (1800W, T1A max);
– Solar panel XT60 charging (600W 11A max);
– Alternator charging (1800W);
– Car charger (charging when starting the engine, 12/24V 10A max);

3.What devices can the product’s AC output port power?****

– With 2,000W rated power and 4,000W peak power, the product’s AC output port can power most household appliances. Before you use it, we recommend that you confirm the power requirements of your appliances and ensure the total power of all loaded appliances is lower than the rated power.

4.Can I charge it at SOHZ and then output through 60HZ when using it?
**** – Yes, the device will detect the frequency required by your electrical equipment and switch automatically, or you can switch manually, But in UPS mode, the frequency requirements of the electrical equipment should be consistent with the grid, because i n this mode SuperBase Pro 1500 has no way to coordinate them.

9.Can’t recelve the verification code when registering an account?
**** – Please check if the verification code is in the spam of your mailbox.

Troubleshooting

Indicator (Flash) Issue Troubleshooting
OVERLOAD Overload Protection Normal operation will be resumed automatically

after you remove the overloaded device and restart the product. Electrical appliances should be used within rated power.
| High Temperature Protection| It can be resumed automatically after the battery cools down.
| Low Temperature Protection| It can be resumed automatically after the battery temperature rises above 32°F (0°C).
| Error Warning| Contact Zendure Customer Service for further information.
/| Reset method| Reset method:
Press and hold 3 buttons (power button + AC button + DC button) at the same time for 5 seconds, when you hear a “di”, the SBP starts to reset.
Applicable scenarios for reset:
1.Can’t connect to the internet.
2.Failed to bind the SuperBase Pro.
3.The screen is off and the button light is on.
4.There is no output from the type-C port.
5.The screen is abnormal.
6.The screen is frozen.
7.Crash.
/| Inaccurate battery display| Battery calibration:
After OTA or manually burning the firmware, discharge the device to 0% power (for example, the power of the device used by the user cannot be discharged to 0%, and there is a little remaining power, so that the device can run out of remaining power with no load).
And then connect the charging cable to charge the device to 100% power (the charging power can be set to any one of the 5 levels), until the charging power reaches 50W and below, that is, the SOC learning is completed.

Model: ZDSBP1500 ™
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ZENDURE User Manuals

Related Manuals