PENTAIR H SERIES Water Filtration Systems Instruction Manual

June 9, 2024
Pentair

H SERIES Water Filtration Systems

EVERPURE

Product Specifications

The EVERPURE filter system is available in six different models,
H-54, H-300, H-104, H-300-HSD, H-300-NXT, and H-1200. Each model
has a different rated capacity ranging from 750 to 1000 gallons.
The filter system requires cartridge replacement once a year or
sooner if the flow becomes too slow or if the rated capacity is
reached.

Tools Required

  • Plumbers Tape
  • Locking Washers (2 required)
  • Screws (2 required)
  • Angle Stop Valve Adaptor
  • Tubing, 1/4 poly (per foot)
  • Elbow Fitting Pack Restrictor (2 required)
  • Faucet Connector
  • Everpure Filter Timer

Basic Installation Instructions

  1. Open the carton and inspect the parts.
  2. Verify the undersink mounting location.
  3. Mount the filter head under the sink.

Step 1: Open Carton & Inspect Parts

The installation parts included in the carton are as
follows:

Key Description Part No.
1 QL3 Filter Head (incl. Qty. 2 ea of 3 & 4) EV925831
2 Filter Cartridge (incl. 10) EV925268, EV927072, EV961211, EV927075,

EV927441
3| Locking Washers (2 req.)| EV306204
4| Screws (2 req.)| EV306196
5| Angle Stop Valve Adaptor| EV312120
6| Tubing, 1/4 poly (per foot)| A0860119
7| Elbow Fitting Pack Restrictor (incl. Qty. 2 ea of 3 &
4)| EV308168
8| Plumbers Tape| EV312119
9| Faucet Connector| EV312135
10| Everpure Filter Timer| EV314160

Step 2: Verify Undersink Mounting Location

Measure 22 inches from the base of the cabinet and mark the
mounting location for the top of the filter head. Ensure there is
enough space above the head to open and close the built-in shut-off
valve and to avoid crimping the water line tubing. Also, ensure the
chosen location offers easy access for future cartridge
changes.

Note: The head and cartridge must be mounted in
the vertical position, with the cartridge hanging down.

Step 3: Mount Filter Head Under Sink

A. Identify the filter head and the two elbow fittings. Note
that the outlet fitting has a black band, which includes a small
restrictor insert to ensure maximum flow at 0.5 gpm (1.9 Lpm) per
minute.

B. Apply plumbers tape to the threads of each elbow fitting.
Wrap the tape in the direction of the threads to ensure a tight fit
and avoid small leaks.

Important: The use of saddle valves is
prohibited by the Universal Plumbing Code adopted by over 20 states
and other specific state and county codes. Copper tubing should not
be used with the John Guest fittings provided with the Everpure
Filter System. If copper tubing is required, you must use copper
compression fittings available from any hardware/plumbing
supply.

For any related questions, adhere to your state/local plumbing
codes and consult your licensed plumber.

For purchase of replaceable components, please contact your
local distributor. H-1200 customers: Instructions for installing
the H-1200 begin on page 6 of this Installation and Operation
Guide.

EVERPURE
H SERIES WATER FILTRATION SYSTEMS SISTEMA DE FILTRACIÓN DE AGUA DE LA SERIE H H SÉRIE SYSTÈME DE FILTRAGE D’EAU INSTALLATION AND OPERATION MANUAL MANUAL DE INSTALACIÓN Y OPERACIÓN MANUEL D’INSTALLATION ET D’UTILISATION

INSTALLATION INSTRUCTIONS – ENGLISH Product Specifications …………………………………… Page 3 Tools Required ………………………………………………. Page 4 Basic Installation Instructions………………………….. Page 4 H-1200 Installation Instructions …………………….Pages 6-7 Claims & Notes………………………………………………..Page 7
INSTRUCCIONES DE INSTALACIÓN – ESPAÑOL Especificaciones Del Producto …………………….. Página 14 Herramientas necesarias …………………………….. Página 15 Instrucciones básicas de instalación……………… Página 15 H 1200 Instrucciones de instalación …………. Páginas 17-18 Declaraciones y notas …………………………………. Página 18 INSTRUCTIONS D’INSTALLATION – FRANÇAIS Caractéristiques Techniques Du Produit ………….. Page 25 Outils nécessaires………………………………………… Page 26 Instructions d’installation de base…………………… Page 26 Consignes d’utilisation pour l’H 1200………….. Pages 28-29 Revendication & remarques …………………………… Page 29
2 · EVERPURE H-Series Water Filtration Systems

ENGLISH

Thank you for purchasing an Everpure§ commercial-grade water filtration system for your home. With your Everpure system, you get premium quality water direct from your tap that’s great-tasting and convenient for you and your family. Product Specifications:
·For Cold Water Use Only ·Temperature Range: 35-100°F (2-38°C) ·Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar) ·Service Flow Rate: 0.5 gpm (1.9 Lpm)

The Universal Plumbing Code adopted by over 20 states, and other specific state and county codes, prohibit the use of saddle valves and their use is never recommended. You must adhere to your state/local plumbing codes. Consult your licensed plumber if you have related questions.
Do NOT use copper tubing with the John Guest Fittings provided with your Everpure Filter System. Copper tubing may appear to fit, but water leaks will develop over time and use. If copper tubing is required, you must use copper compression fittings available from any hardware/plumbing supply.

THE OWNER’S GUIDE IS APPLICABLE FOR THE FOLLOWING EVERPURE FILTER MODELS:
Model H-54 Rated Capacity: 750 gal (2,839 L) Model H-300 Rated Capacity: 300 gal (1,136 L) Model H-104 Rated Capacity: 1,000 gal (3,785 L) Model H-300-HSD Rated Capacity: 300 gal (1,136 L) Model H-300-NXT Rated Capacity: 300 gal (1,136 L) Model H-1200 Rated Capacity: 1,000 gal (3,785 L) For optimum performance, cartridge replacement is required once a year, or sooner if flow becomes too slow for convenience, or if the unit’s rated capacity is reached.
For purchase of replaceable components, please contact your local distributor. H-1200 customers: Instructions for installing the H-1200 begin on page 6 of this Installation and Operation Guide.

Multiple Appliance Connections: You can also connect your Everpure Filter to the refrigerator for ice and water, an instant hot water dispenser or chiller, or a plumbed-in coffee brewer. Simply install connection “tees” (available from any hardware/plumbing supply) in the water line between the filter and the faucet adaptor, and run new tubing to each appliance. NOTE: Spent adsorption media will not be regenerated and used. NOTE: If adsorption media is affected by chlorine, water supply should be treated to remove chlorine prior to entering filter. NOTE: DO NOT connect this system to a commercial ice maker. These appliances require flow and volume beyond the design limits of your undersink filter system. NOTE: If connecting to a home ice maker and there is no filter faucet connection under the sink, a flush valve is required.

EVERPURE H-Series Water Filtration Systems · 3

ENGLISH

BASIC INSTALLATION INSTRUCTIONS
Tools Needed For Installation · #2 Phillips Screwdriver · Wrench · Pencil · Utility Knife · Measuring Tape

1. OPEN CARTON & INSPECT PARTS Installation Parts

Key Description

Part No.

1

QL3 Filter Head

(incl. Qty. 2 ea of 3 & 4 )

EV925831

2

Filter Cartridge (incl. 10 )

­ Model H-54

EV925268

­ Model H-300

EV927072

­ Model H-104

EV961211

­ Model H-300-HSD

EV927075

­ Model H-300-NXT

EV927441

3

Locking Washers (2 req.)

EV306204

4

Screws (2 req.)

EV306196

5

Angle Stop Valve Adaptor

EV312120

6

Tubing, 1/4″ poly (per foot)

A0860119

7

Elbow Fitting Pack Restrictor

EV308168

(incl. Qty. 2 ea of 3 & 4 )

8

Plumbers Tape

EV312119

9

Faucet Connector

EV312135

10

Everpure Filter Timer

EV314160

1 1 2
2

2. VERIFY UNDERSINK MOUNTING LOCATION Measure 22″ from the base of the cabinet, and mark the mounting location for the top of the filter head. Make sure there is adequate space above the head to open and close the built-in shut off valve and to avoid crimping the water line tubing. Also, make sure your chosen location offers easy access for future cartridge changes.

3

4

5

7 6
10
8

9

22″

4 · EVERPURE H-Series Water Filtration Systems

ENGLISH

DIMENSION

Width

Height

Depth

3

B

H-54

5″

15″

5″

H-104

5″

20″

5″

H-300

5″

22″

5″

H-300-HSD

5″

22″

5″

H-300-NXT

5″

22″

5″

NOTE: The head and cartridge must be mounted in the

E

vertical position, with the cartridge hanging down.

3. MOUNT FILTER HEAD UNDER SINK A. Identify Filter Head and the two Elbow Fittings, and note that the Outlet Fitting has a black band. This fitting includes a small restrictor insert to ensure maximum flow at 0.5 gpm (1.9 Lpm) per minute. B. Apply Plumbers Tape to the threads of each Elbow Fitting. Wrap tape in direction of the threads to ensure a tight fit and avoid small leaks.
4 C. Screw Inlet Elbow Fitting into the left side of the filter head, and hand tighten only. D. Screw Outlet Elbow Fitting (black band) into the right
side of the filter head in the same manner. E. Securely mount the filter head on the cabinet wall
using the enclosed mounting screws and washers.

4. ATTACH INLET WATER SUPPLY

F. Locate and close the cold water Angle Stop Valve under your kitchen sink. Open cold water line of faucet

to release water pressure.

G. Unscrew and disconnect the braided tubing on top of

the Angle Stop Valve.

H. Attach the bottom of Angle Stop Adaptor to the existing cold water Angle Stop Valve.

G

I. Attach the braided tubing to the top of the Angle Stop Adaptor.

J. Close side valve on Angle Stop Adaptor and open cold

water Angle Stop Valve to return water service to

kitchen sink. Check for leaks.

NOTE: Plumbers Tape should not be required for

these next steps. K. Measure length of tubing needed to connect Angle

L

Stop Adaptor to Inlet Elbow Fitting on Filter Head.

Allow adequate tubing to avoid sharp turns.

L. Cut tubing at a 90° angle using a sharp knife.

M. Insert ends of tubing into quick-connect fittings. Push tube into fitting and gently pull to confirm a tight fit.

5. ATTACH FILTERED WATER TO SINK FAUCET

N. Install separate faucet for filtered drinking water.

Follow individual manufacturer’s instructions. O. Attach Faucet Connector Fitting to bottom end of

5

threads on new faucet assembly. Plumbers Tape

N

should not be required for this step.

P. Measure length of tubing needed to connect the

Outlet Elbow Fitting on Filter Head to the new Faucet

Connector Fitting. Allow adequate tubing to avoid

sharp turns. Cut and insert each end of the tubing into

the fittings.

O

C

D

F I
H M
P

EVERPURE H-Series Water Filtration Systems · 5

ENGLISH

6. INSTALL AND FLUSH FILTER CARTRIDGE Q. Lift handle of the built-in shut off Valve on the Head.
R. Hold Head firmly with one hand.
S. Align cartridge lug with label on filter Head.
T. Insert filter Cartridge ­ Push upwards.
U. Turn it to the right ­ About 1/4 turn ­ Until rotation stops.
V. Open Side Valve of Angle Stop Adaptor and check for leaks up to Inlet Elbow Fitting.
W. Open Filtered Water Faucet.
X. Lower handle of built-in shut off valve on the Head, to flush water to the sink.
NOTE: Flush new filter cartridges for at least 5 minutes to remove air and any loose carbon. At first the water may appear cloudy due to trapped air in the filter and tubing. If water continues to be cloudy for more than one week, please contact Everpure Technical Services for assistance.
Y. Activate Filter Timer by pinching bubble until you feel a change in resistance as the filter timer “pops.” Within a few seconds, a thin RED line will appear in the white window showing the Timestrip has been activated. Peel away backing and adhere to desired location. When the white window is completely filled with RED, it is time to replace your product.

6 V Y

Q

S

Label

Lug

R T

U

W

X

H-1200 INSTRUCTIONS

Tools Needed For Installation · #2 Phillips Screwdriver · Wrench · Utility Knife · Measuring Tape · Pencil

1. OPEN CARTON & INSPECT PARTS Installation Parts

Key Description

1

Twin Filter Head

H-1200 Filter Cartridges

2

(Set of 2) (Includes 10 )

3

Locking Washers (2 req.)

4

Screws (2 req.)

5

Angle Stop Valve Adaptor

6

Tubing, 1/4″ poly (per foot)

7

Elbow Fitting Pack Restrictor (incl. Qty. 2 ea of #3 & #4)

8

Plumbers Tape

9

Faucet Connector

10

Everpure Filter Timer

11

Shut Off Valve, 3/8″ John Guest x 3/8″ FPT

12

Coupler, 3/8″ FPT Stainless

Part No. N/A
EV928201
EV306204 EV306196 EV312120 A0860119
EV308168
EV312119 EV312135 EV314160
EV309860
EV312350

6 · EVERPURE H-Series Water Filtration Systems

1 1
2

34

5

7

8

6

10

11

12 9

ENGLISH

2. VERIFY UNDERSINK MOUNTING LOCATION Measure 22″ from the base of the cabinet, and mark the

2

mounting location for the top of the filter head. Measure

13″ for the width required for the H-1200 System with dual

cartridges. Make sure there is adequate space above the

head to open and close the shut-off valve and to avoid

crimping the water line tubing. Also, make sure your chosen

location offers easy access for future cartridge changes.

DIMENSION

Width

Height

Depth

H-1200

13″

22″

5″

NOTE: The head and cartridge must be mounted in the

3

vertical position, with the cartridge hanging down.

3. MOUNT FILTER HEAD UNDER SINK A. Identify Dual Filter Head and Shut Off Valve (EV309860). B. Apply Plumbers Tape to the threads on the inlet (left) side of the Head. Screw on the new Shut Off Valve and hand tighten. Repeat for the Stainless Coupler (EV312350) for the outlet (right) side of the Head. C. Apply Plumbers Tape to the threads of the Outlet Elbow Fitting (black band). Screw into the outlet of the Stainless Coupler. Wrap tape in direction of the threads to ensure a tight fit and avoid small leaks. D. Securely mount the filter head on the cabinet wall using the enclosed mounting screws and washers.

4. Go to page 5 and follow Basic Installation Instructions, Steps 4, 5, and 6, to complete the H-1200 System installation.

Dual Filter Head
B

22″
A Shut Off Valve
C

CLAIMS & NOTES This installation must comply with all applicable state and local regulations. Do not use with water that is microbiologically unsafe or unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on waters that may contain filterable cysts. Spent adsorption media will not be regenerated and used. If adsorption media is affected by chlorine, water supply should be treated to remove chlorine prior to entering filter. Testing was performed under standard laboratory conditions, actual performance may vary. EPA Est. No. 002623-IL-002
The H-54, H-300, H-104, H-300-HSD, & H-1200 are Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 42 and 53 for the claims specified C US on the Performance Data Sheet.
The H-300-NXT is Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 42, 53 and 401 for the claims specified on the Performance C US Performance Data Sheet.

D
The H-1200 is certified by IAPMO R&T against NSF/ANSI 53 for the reduction of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS).
EVERPURE H-Series Water Filtration Systems · 7

ENGLISH

EVERPURE

H-104 CARTRIDGE – PART NO. EV9612-11, EV9612-16

IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.
FEATURES · Finely polishes treated water to premium quality for
drinking and cooking. · Reduces chlorine taste and odor. · Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes. · NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means. · Reduces common earthy, moldy, shy tastes and odors. · Reduces lead to below the Federal Action Level. · Reduces particles as small as 0.5 micron in size by
mechanical means.

H-104 Performance Data

This system has been tested according to NSF/ANSI 42 and 53
foHr-t1h0e4rPedEuRcFtiOonRMofAthNeCsEuDbsAtTanAces listed be low. The concentration of the indicated substances in wate4r2enatnedring
the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specied in NSF/ANSI 42 and 53.
42 and

Substance

Influent Challenge Max. Permissible Product Reduction Minimum Average

Concentration

Water Concentration Requirements Reduction Reduction

Standard 42–Aesthetic Effects

Chlorine

2.0 mg/L ± 10%

50%

87.8%

Particulate, Class I particles 0.5 to <1 µm

at least 10,000 particles/mL

Standard 53–Health Effects

85%

98.8%

Cyst

Minimum 50,000/L

99.95% 99.99% 99.99%

Lead 8.5 Lead 6.5

0.15 mg/L ± 10% 0.15 mg/L ± 10%

0.010 mg/L 0.010 mg/L

99.3% 98.7%

99.3% 99.3%

*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

OPERATING SPECIFICATIONS · Capacity: 1,000 gallons (3,780L) · Pressure Requirement: 10-125 psi (0.7 – 8.6 bar), non-shock · Temperature: 35-100°F (2°-38°C) · Flow Rate: 0.5 gpm (1.9 Lpm)

PERFORMANCE DATA SHEET
H-104 DRINKING WATER SYSTEMS

GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS · Space required: 5 x 5 x 20 in. (13 x 13 x 51 cm) including
2½ inches of clear space under unit for cartridge change. · Install vertically with cartridge hanging down. · Use minimum length of tubing possible. · Flush new cartridge at full ow for three minutes to purge air. · Replace cartridges when capacity is reached, or when flow
becomes too slow, but at least annually.

SPECIAL NOTICES · Installation instructions, parts and service availability,
and standard warranty are included with the product. · This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter cartridges. Suggested retail $122.99. · Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certied for cyst reduction may be used on disinfected waters that may contain lterable cysts. · The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water. · Check for compliance with state and local laws and regulations. · Tested under standard laboratory conditions, actual performance may vary. · Spent adsorption media will not be regenerated and used. · If adsorption media is aected by chlorine, water supply should be treated to remove chlorine prior to entering filter.

C US

System Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 42 and 53 for the claims specified on the Performance Data Sheet.
EPA Est. No. 002623-IL-002

8 · EVERPURE H-Series Water Filtration Systems

ENGLISH

EVERPURE

H-54 CARTRIDGE – PART NO. EV9730-06, EV9252-06, EV9252-66, EV9252-67, EV9252-68

IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.
FEATURES · Finely polishes treated water to premium quality for
drinking and cooking. · Reduces chlorine taste and odor. · Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and suldes. · NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means. · Reduces common earthy, moldy, shy tastes and odors. · Reduces lead to below the Federal Action Level of 15 ppb. · Reduces particles as small as 0.5 micron in size by
mechanical means.

H-54 Performance Data

THh-is10sy4sPteEmRFhaOsRbMeAenNtCeEstDedAaTcAcording to NSF/ANSI 42 and 53

for the reduction of the substances listed below.

42 and

The concentration of the indicated substances in water entering

the system was reduced to a concentration less than or equal to

the permissible limit for water leaving the system, as specified

in NSF/ANSI 42 and 53.

42 and

Substance

Influent Challenge Concentration

Standard 42–Aesthetic Effects

Max. Permissible Product Reduction Minimum Average Water Concentration Requirements Reduction Reduction

Chlorine

2.0 mg/L ± 10%

50%

86.8%

Particulate, Class I particles 0.5 to <1 µm

at least 10,000 particles/mL

Standard 53–Health Effects

85%

98.8%

Cyst

Minimum 50,000/L

99.95%

99.99% 99.99%

Lead 8.5

0.15 mg/L ± 10%

0.005 mg/L

98.7%

99.3%

Lead 6.5

0.15 mg/L ± 10%

0.005 mg/L

99.3%

99.3%

*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

OPERATING SPECIFICATIONS · Capacity: 750 gallons (2,839L) · Pressure Requirement: 10-125 psi (0.7 – 8.6 bar), non-shock · Temperature: 35-100°F (2°-38°C) · Flow Rate: 0.5 gpm (1.9 Lpm)

PERFORMANCE DATA SHEET
H-54 DRINKING WATER SYSTEMS

GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS · Space required: 5 x 5 x 15 in. (13 x 13 x 38 cm) including
2½ inches of clear space under unit for cartridge change. · Install vertically with cartridge hanging down. · Use minimum length of tubing possible. · Flush new cartridge at full ow for three minutes to purge air. · Replace cartridges when capacity is reached, or when flow
becomes too slow, but at least annually.

SPECIAL NOTICES · Installation instructions, parts and service availability,
and standard warranty are included with the product. · This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter cartridges. Suggested retail $100.99. · Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certied for cyst reduction may be used on disinfected waters that may contain lterable cysts. · The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water. · Check for compliance with state and local laws and regulations. · Tested under standard laboratory conditions, actual performance may vary. · Spent adsorption media will not be regenerated and used. · If adsorption media is aected by chlorine, water supply should be treated to remove chlorine prior to entering filter.

C US

System Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 42 and 53 for the claims specified on the Performance Data Sheet.
EPA Est. No. 002623-IL-002

EVERPURE H-Series Water Filtration Systems · 9

EVERPURE

PERFORMANCE DATA SHEET
H-300 DRINKING WATER SYSTEMS

ENGLISH

H-300 CARTRIDGE – PART NO. EV9270-71, EV9270-72,

IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.

OPERATING SPECIFICATIONS · Capacity: 300 gallons (1,135L) · Pressure Requirement: 10-125 psi (0.7 – 8.6 bar), non-shock · Temperature: 35-100°F (2°-38°C) · Flow Rate: 0.5 gpm (1.9 Lpm)

FEATURES

· Finely polishes treated water to premium quality for drinking and cooking.

PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING

· Reduces chlorine taste and odor.

· Reduces dirt, rust and other particulates such as oxidized iron, manganese, and suldes.

Substance

Influent Challenge Maximum Permissible Product Concentration mg/L Water Concentration mg/L

· NSF/ANSI Standard 53 certied to reduce cysts such as

alachlor

0.050

0.001

Cryptosporidium and Giardia by mechanical means. · Controls even extreme levels of common “off” taste and odors,
including those which are earthy, moldy, and fishy. · Reduces lead to below the Federal Action Level.

atrazine benzene carbofuran carbon tetrachloride chlorobenzene

0.100 0.081 0.190 0.078 0.077

0.003 0.001 0.001 0.0018 0.001

· Effectively reduces Volatile Organic Chemicals (VOCs), including Trihalomethanes (THMs).
· Reduces particles as small as 0.5 micron in size by mechanical means.

chloropicrin 2,4-D dibromochloropropane (DBCP) o-dichlorobenzene p-dichlorobenzene

0.015 0.110 0.052 0.080 0.040

0.0002 0.0017 0.00002 0.001 0.001

1,2-dichloroethane

0.088

0.0048

H-300 Performance Data This system has been tested according to NSF/ANSI 42 and 53

1,1-dichloroethylene cis-1,2-dichloroethylene trans-1,2-dichloroethylene 1,2-dichloropropane

0.083 0.170 0.086
0.080

0.001 0.0005 0.001 0.001

for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to

cis-1,3-dichloropropylene dinoseb endrin ethylbenzene

0.079 0.170 0.053 0.088

0.001 0.0002 0.00059 0.001

the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

Substance

Influent Challenge Concentration

Standard 42–Aesthetic Effects

Chlorine

2.0 mg/L ± 10%

Particulate, Class I particles 0.5 to <1 µm

at least 10,000 particles/mL

Max. Permissible Product Reduction Minimum Average Water Concentration Requirements Reduction Reduction

50%

86.8%

85%

98.8%

ethylene dibromide (EDB) haloacetonitriles (HAN):
bromochloroacentonitrile dibromoacetonitrile dichloroacetonitrile trichloroacetonitrile
haloketones (HK): 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone
heptachlor
heptachlor epoxide
hexachlorobutadiene

0.044
0.022 0.024 0.0096 0.015
0.0072 0.0082 0.025 0.0107 0.044

0.00002
0.0005 0.0006 0.0002 0.0003
0.0001 0.0003 0.00001 0.0002 0.001

Standard 53–Health Effects

hexachlorocyclopentadiene

0.060

0.000002

nd

Cyst

Minimum 50,000/L

99.95%

99.99% 99.99%

lindane methoxychlor

0.055 0.050

0.00001 0.0001

Lead 6.5

0.15 mg/L ± 10%

0.005 mg/L

99.3%

99.3%

pentachlorophenol

0.096

0.001

Lead 8.5

0.15 mg/L ± 10%

0.005 mg/L

98.7%

99.3%

simazine styrene

0.120 0.150

0.004 0.0005

nd

Chloroform

0.300 mg/L

0.015 mg/L

95.8%

98.9%

1,1,2,2-tetrachloroethane

0.081

0.001

tetrachloroethylene

0.081

0.001

*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

toluene

0.078

0.001

2,4,5-TP(silvex)

0.270

0.0016

The H-300 is Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 42

tribromoacetic acid 1,2,4-trichlorobenzene 1,1,1-trichloroethane

0.042 0.160 0.084

0.001 0.0005 0.0046

C US

and 53 for the claims specified on the Performance Data Sheet.

EPA Est. No. 002623-IL-002

NOTE: Spent adsorption media will not be regenerated and used. If adsorption media is affected by chlorine, water supply

1,1,2-trichloroethane
trichloroethyl ene
trihal omethanes (includes): chloroform (surrogate chemical) bromoform bromodichloromethane chlorodibromomethane xylenes (total)

0.150 0.180
0.300 0.070

0.0005 0.001
0.015 0.001

should be treated to remove chlorine prior to entering filter.

10 · EVERPURE H-Series Water Filtration Systems

2 and and

EVERPURE

H-1200 CARTRIDGE – PART NO. EV9282-01, EV9282-03,

IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.

FEATURES · Finely polishes treated water to premium quality for
drinking and cooking. · NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means. · IAPMO R&T certified against NSF/ANSI 53 for the reduction
of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS). · High- performance system certified to reduce up to 97.5% of PFOA/PFOS, commonly known as “forever chemicals”. · Reduces dirt, rust and other particulates sulfides (oxidized iron and manganese ­ As tested by Everpure). · Controls even extreme levels of common “off” taste and odors, including those which are earthy, moldy, and fishy. · Reduces lead to below the Federal Action Level of 15 ppb. · Effectively reduces Volatile Organic Chemicals (VOCs), including Trihalomethanes (THMs). · Effectively reduces methyl tertiary-butyl ether (MTBE). · Reduces particles as small as 0.5 micron in size by mechanical means.
H-1200 Performance Data

This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

Substance

Influent Challenge Max. Permissible Product Reduction Minimum Average

Concentration

Water Concentration Requirements Reduction Reduction

Standard 42–Aesthetic Effects

Chlorine

2.0 mg/L ± 10%

50%

86.8%

Chloramine

3.0 mg/L ± 10%

Particulate, Class I particles 0.5 to <1 µm

at least 10,000 particles/mL

Standard 53–Health Effects

Cyst

Minimum 50,000/L

0.5 mg/L

85%

98.3% 98.8%

99.95%

99.99% 99.99%

Lead 6.5

0.15 mg/L ± 10%

0.005 mg/L

99.3%

99.3%

Lead 8.5 Methyl tertbutyl ether Chloroform
PFOA/PFOS

0.15 mg/L ± 10% 0.015 mg/L ± 20%
0.300 mg/L 0.0015mg/L± 10%

0.005 mg/L 0.005 mg/L 0.015 mg/L 0.00007mg/L

98.7% 83.5% 99.8% 95.76%

99.3% 91.5% 99.8% 97.57%

*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

C US

The H-1200 is Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 42 and 53 for the claims specified on the Performance Data Sheet.
EPA Est. No. 002623-IL-002

The H-1200 is certified by IAPMO R&T against NSF/ANSI 53 for the reduction of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS).

PERFORMANCE DATA SHEET
H-1200 DRINKING WATER SYSTEMS

OPERATING SPECIFICATIONS · Capacity: 1,000 gallons (3,785L) · Pressure Requirement: 10-125 psi (0.7 – 8.6 bar), non-shock · Temperature: 35-100°F (2°-38°C) · Flow Rate: 0.5 gpm (1.9 Lpm)

PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING

Substance

Influent Challenge Concentration mg/L

alachlor atrazine benzene carbofuran carbon tetrachloride chlorobenzene chloropicrin 2,4-D dibromochloropropane (DBCP) o-dichlorobenzene p-dichlorobenzene 1,2-dichloroethane 1,1-dichloroethylene cis-1,2-dichloroethylene trans-1,2-dichloroethylene 1,2-dichloropropane cis-1,3-dichloropropylene dinoseb endrin ethylbenzene ethylene dibromide (EDB) haloacetonitriles (HAN):
bromochloroacentonitrile dibromoacetonitrile dichloroacetonitrile trichloroacetonitrile
haloketones (HK): 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone
heptachlor heptachlor epoxide hexachlorobutadiene hexachlorocyclopentadiene lindane methoxychlor pentachlorophenol simazine styrene 1,1,2,2-tetrachloroethane tetrachloroethylene toluene 2,4,5-TP(silvex) tribromoacetic acid 1,2,4-trichlorobenzene 1,1,1-trichloroethane 1,1,2-trichloroethane trichloroethylene trihalomethanes (includes): chlor oform (surrogate chemical) bromoform bromodichloromethane chlorodibromomethane xylenes (total)

0.050 0.100 0.081 0.190 0.078 0.077 0.015 0.110 0.052 0.080 0.040 0.088 0.083 0.170 0.086 0.080 0.079 0.170 0.053 0.088 0.044
0.022 0.024 0.0096 0.015
0.0072 0.0082 0.080 0.0107 0.044 0.060 0.055 0.050 0.096 0.120 0.150 0.081 0.081 0.078 0.270 0.042 0.160 0.084 0.150 0.180
0.300
0.070

Maximum Permissible Product Water Concentration mg/L
0.001 0.003 0.001 0.001 0.0018 0.001 0.0002 0.0017 0.00002 0.001 0.001 0.0048 0.001 0.0005 0.001 0.001 0.001 0.0002 0.00059 0.001 0.00002
0.0005 0.0006 0.0002 0.0003
0.0001 0.0003 0.0004 0.0002 0.001 0.000002 0.00001 0.0001 0.001 0.004 0.0005 0.001 0.001 0.001 0.0016 0.001 0.0005 0.0046 0.0005 0.001
0.015
0.001

NOTE: Spent adsorption media will not be regenerated and used. If adsorption media is affected by chlorine, water supply should be treated to remove chlorine prior to entering filter.
EVERPURE H-Series Water Filtration Systems · 11

ENGLISH

EVERPURE

PERFORMANCE DATA SHEET
H-300-HSD DRINKING WATER SYSTEMS

ENGLISH

H-300-HSD CARTRIDGE – PART NO. EV9270-74, EV9270-75

IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.

OPERATING SPECIFICATIONS · Capacity: 300 gallons (1,135L) · Pressure Requirement: 10-125 psi (0.7 – 8.6 bar), non-shock · Temperature: 35-100°F (2°-38°C) · Flow Rate: 0.5 gpm (1.9 Lpm)

FEATURES

· For high silt density water vs. standard H-300. · Finely polishes treated water to premium quality for

PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING

drinking and cooking.

· Reduces chlorine taste and odor. · Reduces dirt, rust and other particulates such as oxidized iron,
manganese, and sulfides. · NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.

Substance
alachlor atrazine benzene carbofuran

Influent Challenge Concentration mg/L
0.050 0.100 0.081 0.190

Maximum Permissible Product Water Concentration mg/L
0.001 0.003 0.001 0.01

· Controls even extreme levels of common “off” taste and odors, including those which are earthy, moldy, and fishy.
· Reduces lead to below the Federal Action Level of 15 ppb. · Effectively reduces Volatile Organic Chemicals (VOCs),

carbon tetrachloride chlorobenzene chloropicrin 2,4-D dibromochloropropane (DBCP)

0.078 0.077 0.015 0.110 0.052

0.0018 0.001 0.0002 0.0017 0.00002

· Effectively reduces methyl tertiary-butyl ether (MTBE). · Reduces particles as small as 0.5 micron in size by
mechanical means.

o-dichlorobenzene p-dichlorobenzene 1,2-dichloroethane 1,1-dichloroethylene

0.080 0.040 0.088 0.083

0.001 0.001 0.0048 0.001

cis-1,2-dichloroethylene

0.170

0.0005

H-300-HSD Performance Data

trans-1,2-dichloroethylene 1,2-dichloropropane

0.086 0.080

0.001 0.001

This system has been tested according to NSF/ANSI 42 and 53

cis-1,3-dichloropropylene

0.079

0.001

for the reduction of the substances listed below. The concentration of the indicated substances in water entering

dinoseb endrin ethylbenzene

0.170 0.053 0.088

0.0002 0.00059 0.001

the system was reduced to a concentration less than or equal to

ethylene dibromide (EDB)

0.044

0.00002

the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

haloacetonitriles (HAN): bromochloroacentonitrile dibromoacetonitrile dichloroacetonitrile

0.022 0.024 0.0096

0.0005 0.0006 0.0002

Substance

Influent Challenge Max. Permissible Product Reduction Minimum Average

Concentration

Water Concentration Requirements Reduction Reduction

Standard 42–Aesthetic Effects

Chlorine

2.0 mg/L ± 10%

50%

86.8%

trichloroacetonitrile
haloketones (HK): 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone
heptachlor

0.015
0.0072 0.0082 0.080

0.0003
0.0001 0.0003 0.0004

Particulate, Class I particles 0.5 to <1 µm

at least 10,000 particles/mL

85%

98.8%

heptachlor epoxide hexachlorobutadiene hexachlorocyclopentadiene

0.0107 0.044 0.060

0.0002 0.001 0.000002

Standard 53–Health Effects

lindane

0.055

0.00001

nd

Cyst

Minimum 50,000/L

99.95%

99.99% 99.99%

methoxychlor pentachlorophenol

0.050 0.096

0.0001 0.001

Lead 6.5

0.15 mg/L ± 10%

0.005 mg/L

99.3%

99.3%

simazine

0.120

0.004

Lead 8.5

0.15 mg/L ± 10%

0.005 mg/L

98.7%

99.3%

styrene 1,1,2,2-tetrachloroethane

0.150 0.081

0.0005 0.001

nd

Chloroform

0.300 mg/L

0.015 mg/L

95.8%

98.9%

tetrachloroethylene

0.081

0.001

(VOC surrogate chemical)

toluene

0.078

0.001

*Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

2,4,5-TP(silvex)

0.270

0.0016

tribromoacetic acid

0.042

0.001

The H-300-HSD is Tested and Certified by NSF

1,2,4-trichlorobenzene 1,1,1-trichloroethane

0.160 0.084

0.0005 0.0046

C US

International against CSA B483.1 and NSF/ANSI 42 and 53 for the claims specified on the Performance Data Sheet.
EPA Est. No. 002623-IL-002

NOTE: Spent adsorption media will not be regenerated and

1,1,2-trichloroethane
trichlor oethylene
trihalomethanes (includes): chloroform (surrogate chemical) bromoform bromodichloromethane chlorodibromomethane xylenes (total)

0.050 0.180
0.300 0.070

0.0005 0.001
0.015 0.001

used. If adsorption media is affected by chlorine, water supply

should be treated to remove chlorine prior to entering filter.

12 · EVERPURE H-Series Water Filtration Systems

EVERPURE

H-300-NXT CARTRIDGE – PART NO. EV927441, EV927446
IMPORTANT NOTICE: Read this Everpure Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water tested to determine your actual treatment needs.
FEATURES · Finely polishes treated water to premium quality for
drinking and cooking. · NSF/ANSI Standard 53 certied to reduce cysts such as
Cryptosporidium and Giardia by mechanical means. · Reduces dirt, rust and other particulates sulfides (oxidized iron
and manganese ­ As tested by Everpure). · Controls even extreme levels of common “off” taste and odors,
including those which are earthy, moldy, and fishy. · Reduces lead to below the Federal Action Level of 15 ppb. · Effectively reduces Volatile Organic Chemicals (VOCs),
including Trihalomethanes (THMs). · Effectively reduces methyl tertiary-butyl ether (MTBE). · Reduces particles as small as 0.5 micron in size by
mechanical means.

H-300-NXT Performance Data
This system has been tested according to NSF/ANSI 42, 53, and 401 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, and 401.

Substance

Influent Challenge Concentration

Standard 42–Aesthetic Effects

Max. Permissible Product Water Concentration

Reduction Minimum Requirements Reduction

Average Reduction

Chlorine

2.0 mg/L ± 10%

50%

86.8%

Particulate, Class I at least 10,000 particles 0.5 to <1 µm particles/mL

85%

98.8%

Standard 53–Health Effects

Cyst

Minimum 50,000/L

99.95%

99.99 99.99%

Lead 6.5

0.15 mg/L ± 10%

0.005 mg/L

99.3%

99.3%

Lead 8.5

0.15 mg/L ± 10%

0.005 mg/L

98.7%

99.3%

Chloroform

0.300 mg/L

0.015 mg/L

95.8%

(VOC surrogate chemical) *Tested using flow rate = 0.5 gpm; pressure = 60 psig; pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

98.9%

Standard 401–Emerging Contaminants

H-104 Phenytoin
Ibuprofen

PERF24O0000R±±M2200A%%NnnggC//LLE

DATA 0.000030 0.000060

mg/L mg/L

Naproxen

140 ± 20% ng/L

0.000020 mg/L

96.3%
95.8%
42 a>n9d6.8%

Estrone

140 ± 20% ng/L

0.000020 mg/L

97.2%

Bisphenol A (BPA) 2,000 ± 20% ng/L 0.000300 mg/L

99.2%

Nonylphenol

1,400 ± 20% ng/L 0.000200 mg/L

97.1%

42 and NSF/ANSI Standard 401 have been deemed as “incidental contaminants/emerging compounds”.
Incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/ perception of drinking water quality.

NOTE: Spent adsorption media will not be regenerated and used. If adsorption media is affected by chlorine, water supply should be treated to remove chlorine prior to entering filter.

PERFORMANCE DATA SHEET
H-300-NXT DRINKING WATER SYSTEM

OPERATING SPECIFICATIONS · Capacity: 300 gallons (1,136L) · Pressure Requirement: 10-125 psi (0.7 – 8.6 bar), non-shock · Temperature: 35-100°F (2°-38°C) · Flow Rate: 0.5 gpm (1.9 Lpm)

PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING

Substance

Influent Challenge Concentration mg/L

alachlor atrazine benzene carbofuran carbon tetrachloride chlorobenzene chloropicrin 2,4-D dibromochloropropane (DBCP) o-dichlorobenzene p-dichlorobenzene 1,2-dichloroethane 1,1-dichloroethylene cis-1,2-dichloroethylene trans-1,2-dichloroethylene 1,2-dichloropropane cis-1,3-dichloropropylene dinoseb endrin ethylbenzene ethylene dibromide (EDB) haloacetonitriles (HAN):
bromochloroacentonitrile dibromoacetonitrile dichloroacetonitrile trichloroacetonitrile
haloketones (HK): 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone
heptachlor heptachlor epoxide hexachlorobutadiene hexachlorocyclopentadiene lindane methoxychlor pentachlorophenol simazine styrene 1,1,2,2-tetrachloroethane tetrachloroethylene toluene 2,4,5-TP(silvex) tribromoacetic acid 1,2,4-trichlorobenzene 1,1,1-trichloroethane 1,1,2-trichlor oethane trichl oroethylene trihalomethanes (includes): chloroform (surrogate chemical) bromoform bromodichloromethane chlorodibromomethane xylenes (total)

0.050 0.100 0.081 0.190 0.078 0.077 0.015 0.110 0.052 0.080 0.040 0.088 0.083 0.170 0.086 0.080 0.079 0.170 0.053 0.088 0.044
0.022 0.024 0.0096 0.015
0.0072 0.0082 0.080 0.0107 0.044 0.060 0.055 0.050 0.096 0.120 0.150 0.081 0.081 0.078 0.270 0.042 0.160 0.084 0.150 0.180
0.300
0.070

Maximum Permissible Product Water Concentration mg/L
0.001 0.003 0.001 0.001 0.0018 0.001 0.0002 0.0017 0.00002 0.001 0.001 0.0048 0.001 0.0005 0.001 0.001 0.001 0.0002 0.00059 0.001 0.00002
0.0005 0.0006 0.0002 0.0003
0.0001 0.0003 0.0004 0.0002 0.001 0.000002 0.00001 0.0001 0.001 0.004 0.0005 0.001 0.001 0.001 0.0016 0.001 0.0005 0.0046 0.0005 0.001
0.015
0.001

The H-300-NXT is Tested and Certified by NSF International against CSA B483.1 and NSF/ C US ANSI 42 and 53 for the claims specified on the Performance Data Sheet.
EPA Est. No. 002623-IL-002
EVERPURE H-Series Water Filtration Systems · 13

ENGLISH

Gracias por comprar un Everpure*sistema de filtración de agua Everpure de categoría comercial para su hogar. Con el sistema Everpure usted obtiene directamente de la llave un agua de primera calidad de buen sabor en forma conveniente para usted y su familia.
Especificaciones Del Producto: ·Para uso únicamente con agua fría ·Gama de temperatura: 2-38°C (35-100°F) ·Presión de servicio mín. – máx.: 0.7-8.6 bar (10-125 psi) ·Caudal de servicio: 1.9 Lpm (0.5 gpm)
EL MANUAL DEL USUARIO SE APLICA A LOS SIGUIENTES MODELOS DE FILTRO EVERPURE: Modelo H-54 Capacidad nominal: 750 Gal (2,839 L) Modelo H-300 Capacidad nominal: 300 Gal (1,136 L) Modelo H-104 Capacidad nominal: 1,000 Gal (3,785 L) Modelo H-300-HSD Capacidad nominal: 300 Gal (1,136 L) Modelo H-300-NXT Capacidad nominal: 300 Gal (1,136 L) Modelo H-1200 Capacidad nominal:1,000 Gal (3,785 L)
Para mayor rendimiento, el cartucho debe ser reemplazado una vez al año o antes si el caudal se vuelve demasiado lento para su conveniencia o si se alcanza la capacidad nominal de la unidad.
Para la compra de componentes reemplazables por favor póngase en contacto con su distribuidor local.
Usuarios del H-1200: Las instrucciones para la instalación del H-1200 comienzan en la página no 15 de este Manual de Instalación y Funcionamiento.

El Código Universal de Plomería (EE.UU.) adoptado por más de 20 estados y otros códigos estatales y de condados específicos prohíben el uso de válvulas de montura y su uso no es nunca recomendado. Usted debe cumplir con los códigos estatales o locales. Consulte con un plomero licenciado si tiene preguntas sobre esto.
NO use tubería de cobre con las conexiones John Guest suministradas con su Sistema de Filtración Everpure. Podría parecer que la tubería de cobre encaja pero con el tiempo y el uso se desarrollarán pérdidas de agua. Si es necesario usar tubos de cobre, debe usar conectores de compresión de cobre disponibles en cualquier tienda de plomería o ferretería.
Conexiones para electrodomésticos múltiples: También puede conectar su Filtro Everpure al refrigerador para el surtidor de hielo y agua, a un surtidor instantáneo de agua caliente o fría o a una cafetera instalada. Simplemente instale conectores en T (disponibles en cualquier tienda de plomería o ferretería) en la línea de agua entre el filtro y el adaptador del grifo, y extienda instale una tubería nueva hacia cada uno de los electrodomésticos. NOTA: NO conecte este sistema a una máquina comercial de hacer hielo. Estas máquinas requieren un caudal y un volumen mayor que los límites de diseño de su sistema de filtración debajo del fregadero. NOTA: Si lo conecta a una máquina de hacer hielo casera y no hay una conexión para un filtro de grifo debajo del fregadero: se necesita una
válvula de descarga.

ESPAÑOL

14 · EVERPURE Sistema De Filtración De Agua De La Serie H

INSTRUCCIONES BÁSICAS DE INSTALACIÓN

Herramientas necesarias Destornillador #2 Phillips · Llave · Cuchillo universal Cinta métrica · Lápiz

1. ABRA EL CARTÓN Y REVISE LAS PIEZAS Piezas de instalación

Clave Descripción

Pieza No

1

QL3 Cabezal de filtro

EV925831

(Cantidad Incluyó 2 cada uno

de 3 y 4 )

2

Cartucho filtrante

(incluye 10 )

­ Modelo H-54

EV925268

­ Modelo H-300

EV927072

­ Modelo H-104

EV961211

­ Modelo H-300-HSD

EV927075

­ Modelo H-300-NXT

EV927441

3

arandelas de seguridad

(requiere 2)

EV306204

4

tornillos (requiere 2)

EV306196

5

Adaptador para válvula de

cierre en ángulo

EV312120

6

Tubería de plástico de 0.64 cm

A0860119

(por 30.48 cm)

7

Codo adaptador y reductor

EV308168

(Cantidad Incluyó 2 cada uno

de 3 y 4 )

8

Cinta de Fontanero

EV312119

9

Conector de grifo

EV312135

10

Medidor de filtro Everpure

EV314160

1 1 2
2

2. COMPRUEBE EL SITIO DE MONTAJE DEBAJO DEL FREGADERO Mida 55.8 cm desde la base del armario y marque el sitio de montaje de la parte superior del cabezal del filtro. Asegúrese de que haya suficiente espacio encima del cabezal para abrir y cerrar la válvula de cierre incorporada y para evitar que la tubería de agua se doble. También, asegúrese de que el sitio que escogió sea fácilmente accesible para cambiar los cartuchos en el futuro.

Dimensiones

Ancho

Altura Profundidad

H-54

12.7 cm

38.1 cm

12.7 cm

H-104

12.7 cm

50.8 cm

12.7 cm

H-300

12.7 cm

55.8 cm

12.7 cm

H-300-HSD

12.7 cm

55.8 cm

12.7 cm

H-300-NXT

12.7 cm

55.8 cm

12.7 cm

NOTA: El cabezal y el cartucho deben montarse en posición vertical, con el cartucho colgando hacia abajo.

3

4

5

7 6
10 8

9

55.8 cm

ESPAÑOL

EVERPURE Sistema De Filtración De Agua De La Serie H · 15

ESPAÑOL

3. MONTE EL CABEZAL DEL FILTRO DEBAJO DEL FREGADERO

A. Identifique el cabezal de filtro y los dos codos

3

adaptadores y note que el adaptador de salida tiene

B

una banda negra. Este adaptador incluye un pequeño

accesorio reductor para asegurar un flujo máximo de 1,9

litros por minuto.

B. Aplique cinta de plomería a las roscas de cada codo

adaptador. Enrolle la cinta en el sentido de las roscas

para asegurar un ajuste firme y evitar las pérdidas

pequeñas.

C. Enrosque el codo adaptador de entrada al lado izquierdo del cabezal de filtro y sólo apriete a mano.

E

D. Enrosque el codo adaptador de salida (banda negra) al lado derecho del cabezal de filtro de la misma manera.

E. Monte firmemente el cabezal del filtro a la pared de armarios usando los tornillos de montaje y las arandelas

incluidas.

4. CONECTE EL ABASTECIMIENTO DE AGUA DE ENTRADA F. Ubique y cierre la válvula de cierre de agua fría en ángulo debajo del fregadero de la cocina. Abra la llave de agua fría del grifo para descargar la presión del agua. G. Destornille y desconecte el tubo trenzado de la parte superior de la válvula de cierre en ángulo. H. Acople la parte inferior del adaptador de cierre en ángulo a la válvula de cierre en ángulo existente para el agua fría. I. Acople el tubo trenzado a la parte superior del adaptador de cierre en ángulo. J. Cierre la válvula del costado del adaptador de cierre en ángulo y abra la válvula de cierre en ángulo para el agua fría para restituir el servicio de agua al fregadero de la cocina. Verifique si hay pérdidas.
NOTA: No se necesitará cinta de Fontanero para los próximos pasos. K. Mida el largo del tubo necesario para conectar el adaptador de cierre en ángulo al codo adaptador de entrada en el cabezal de filtro. Deje suficiente tubo para evitar vueltas agudas. L. Corte el tubo a 90° usando un cuchillo filoso. M. Introduzca las puntas del tubo en los empalmes de conexión rápida. Empuje el tubo dentro de la conexión y tire suavemente para confirmar que el ajuste es firme.

4 G

5. CONECTE EL AGUA FILTRADA AL GRIFO DEL FREGADERO

N. Instale un grifo separado para agua potable filtrada. Siga las instrucciones específicas del fabricante.

O. Acople el conector del grifo a la punta inferior de la rosca del nuevo conjunto de grifo. No se necesitará cinta de

L

Fontanero para este paso.

P. Mida el largo del tubo necesario para conectar el codo adaptador de salida en el cabezal de filtro al conector

del grifo. Deje suficiente tubo para evitar vueltas

agudas. Corte e introduzca cada punta del tubo en los

conectores.

6. INSTALE EL CARTUCHO FILTRANTE Y DEJE CORRER EL AGUA

5

N

O
16 · EVERPURE Sistema De Filtración De Agua De La Serie H

C

D

F I
H M
P

Q. Levante la manilla de la válvula de cierre (válvula de control) en el cabezal.
R. Sujete firmemente el cabezal con una mano. S. Alinee la lengüeta del cartucho con la etiqueta del
cabezal del filtro. T. Introduzca el cartucho filtrante–empuje hacia arriba. U. Gírelo hacia la derecha, aproximadamente un 1/4 de
vuelta hasta que tope. V. Abra la válvula de agua fría y compruebe que no haya
pérdidas hasta el adaptador del codo de entrada. W. Abra el grifo de agua. X. Baje la manilla de la válvula de control para descargar el
agua hacia el fregadero.
NOTA: Deje correr agua por el cartucho filtrante nuevo por lo menos durante 5 minutos para quitar el aire y toda partícula suelta de carbono. Al principio, el agua filtrada pudiera aparecer turbia debido al aire atrapado en el filtro y la tubería. Si el agua continúa opaca por más de una semana, póngase en contacto con el departamento de Servicios Técnicos para que le ayuden: 800-942-1153
Y. Active el temporizador del filtro presionando la burbuja hasta que sienta un cambio en la resistencia cuando se bote el temporizador. En unos pocos segundos aparecerá una línea ROJA delgada en la ventana blanca para mostrar que ya se activó el Timestrip. Desprenda el protector y adhiéralo al sitio donde lo requiera. Cuando la ventana blanca esté completamente llena de ROJO, será momento de reemplazar su producto.

6 V Y

Q

S

Etiqueta Lengüeta

R T

U

W

X

ESPAÑOL

H-1200 INSTRUCCIONES DE INSTALACIÓN

Herramientas necesarias

· Destornillador #2 Phillips · Cinta métrica

· Llave

· Lápiz

· Cuchillo universal

1. OUVREZ LE CARTON ET INSPECTEZ LES PIÈCES Pièces à installer

Clave Descripción

Pieza No

1

Cabezal de filtro

N/A

2

H-1200 Cartucho filtrante (conjunto de 2) (incluye 10 )

EV928201

3

Arandelas de seguridad (requiere 2)

EV306204

4

Tornillos (requiere 2)

EV306196

5

Adaptador para válvula de cierre en ángulo

EV312120

6

Tubería de plástico de 0.64 cm (por 30.48 cm)

A0860119

Codo adaptador y reductor

7

(Cantidad Incluyó 2 cada uno

EV308168

de # 3 y # 4)

8

Cinta de Fontanero

EV312119

9

Conector de grifo

EV312135

10

Medidor de filtro Everpure

EV314160

Válvula de cierre, 3/8″ John

11

Guest x 3/8″ hembra

EV309860

12

Acoplador, 3/8″ hembra inoxidable

EV312350

1 1
2

34

5

7

6

8

10 11

9

12

EVERPURE Sistema De Filtración De Agua De La Serie H · 17

2. COMPRUEBE EL SITIO DE MONTAJE DEBAJO DEL FREGADERO

Mida 55.8 cm desde la base del armario y marque el sitio de

2

montaje de la parte superior del cabezal del filtro. Asegúrese

de que haya suficiente espacio encima del cabezal para abrir

y cerrar la válvula de cierre incorporada y para evitar que la

tubería de agua se doble. También, asegúrese de que el sitio que

escogió sea fácilmente accesible para cambiar los cartuchos en

el futuro.

Dimensiones

Ancho

Altura Profundidad

H-1200

33 cm

55.8 cm

12.7 cm

NOTA: El cabezal y el cartucho deben montarse en posición vertical, con el cartucho colgando hacia abajo.Monte el cabezal

3

del filtro debajo del fregadero

3. MONTE EL CABEZAL DEL FILTRO DEBAJO DEL FREGADERO A. Identifique el cabezal de filtro doble y la válvula de cierre (EV309860). B. Aplique cinta de Fontanero a la rosca del lado de entrada (izquierdo) del cabezal. Atornille la nueva válvula de cierre y ajuste a mano. Repita lo mismo con el acoplador inoxidable (EV312350) para el lado de salida (derecho) del cabezal. C. Aplique cinta de Fontanero a la rosca del codo adaptador de salida (banda negra). Atornille dentro de la salida del acoplador inoxidable. Enrolle la cinta en el sentido de las roscas para asegurar un ajuste firme y evitar las pérdidas pequeñas. D. Monte firmemente el cabezal del filtro a la pared de armarios usando los tornillos de montaje y las arandelas incluidas.

4. Vaya a la página 15 y siga los pasos 4, 5 y 6 de las Instrucciones Básicas de Instalación para completar la instalación del Sistema H-1200.

DECLARACIONES Y NOTAS
Esta instalación debe cumplir con todas las leyes y reglamentos locales y estatales. No lo utilice con agua que sea microbiológicamente peligrosa o de calidad desconocida sin usar una desinfección adecuada, antes o después del sistema. Los sistemas certificados para la reducción de quistes pueden usarse en aguas desinfectadas que pudieran contener quistes filtrables. Las pruebas se realizaron en condiciones normales de laboratorio, el rendimiento real pudiera variar.
EPA Est. No. 002623-IL-002

El H-54, H-300, H-104, H-300-HSD y H-1200 son probados y certificados por NSF International contra CSA B483.1 y NSF / ANSI 42 y 53 para las afirmaciones C US especificadas en los Datos de rendimiento Hoja.

El H-300-NXT ha sido probado y certificado por NSF International contra CSA B483.1 y NSF / ANSI 42, 53 y 401 para las afirmaciones especificadas en la Hoja de C US datos de rendimiento de rendimiento.

El H-1200 está certificado por IAPMO R&T contra NSF/ ANSI 53 para la reducción de ácido perfluorooctanoico (PFOA) y sulfonato de perfluorooctano (PFOS).

55.8 cm

Dual Filter Head

A Shut Off Valve

B C

D

ESPAÑOL

18 · EVERPURE Sistema De Filtración De Agua De La Serie H

ESPAÑOL

EVERPURE Sistema De Filtración De Agua De La Serie H · 19

ESPAÑOL

EVERPURE

HOJA DE INFORMACIÓN SOBRE RENDIMIENTO
SISTEMA DE AGUA POTABLE H-54

CARTUCHO H-54 – PIEZA N. EV9730-06, EV9252-68, EV9252-66, EV9252-67

AVISO IMPORTANTE: Lea esta Hoja de información sobre rendimiento y compare las capacidades de este sistema con sus necesidades reales de tratamiento de agua. Se recomienda que antes de adquirir una unidad de tratamiento de agua, haga analizar su agua para determinar sus necesidades reales de tratamiento del agua.
CARACTERÍSTICAS · Limpia adecuadamente el agua tratada y la convierte en agua
de calidad superior para beber o cocinar. · Reduce el gusto y el olor del cloro. · Reduce la suciedad, el óxido y otros materiales en partículas
como hierro oxidado, manganeso y sulfuros. · Con certificado de la Norma 53 de NSF/ANSI para reducir los
quistes como Cryptosporidium y Giardia por medios mecánicos. · Adsorbe los sabores y olores frecuentes a tierra, moho y pescado. · Reduce el nivel de plomo incluso por debajo de lo que marca el Nivel de recomendación federal (Federal Action Level) de 10 ppb. · Reduce las partículas pequeñas, hasta de 0.5 micrones por medios mecánicos.

DATOS DE RENDIMIENTO DEL H-54

Este sistema ha sido analizado de acuerdo con las Normas
H-N1S0F4/PAENRSFI O42RyM5A3NeCnEcuDaAnTtoAa la reducción de las sustancias

enumeradas a continuación. La concentración de la4s2saunsdtancias

indicadas en el agua que entra al sistema se redujo a una

concentración menor o igual a los límites permitidos para el

agua que sale del sistema, como lo especifican las Normas

NSF/ANSI 42 y 53.

42 and

Sustancia

Concentración de contaminantes en el
agua prefiltrada

Concentración máx. permitida de productos
el agua

enNerecdesuicdcaidónde

Reducción mínima

Reducción promedio

Estándar 42, efectos estéticos

Cloro

2.0 mg/L ± 10%

50%

86.8%

Partículas clase I 0.5 a <1 µm

al menos 10,000 partículas/ml

Estándar 53, efectos en la salud

Quistes

Mínimo 50,000/L

Plomo 8.5

0.15 mg/L ± 10%

Plomo 6.5

0.15 mg/L ± 10%

0.010 mg/L 0.010 mg/L

85%

98.8%

99.95%

99.99% 98.7% 99.3%

99.99% 99.3% 99.3%

*Analizado en un caudal de servicio = 0.5 gpm, presión = 60 psig, pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

ESPECIFICACIONES DE FUNCIONAMIENTO · Capacidad: 750 galones (2.839 litros) · Requisito de presión: 10-125 psi (0.7 – 8.6 bar), sin choque · Temperatura: 35-100°F (2°-38°C) · Caudal: 0.5 gpm (1.9 Lpm)

REQUISITOS GENERALES DE INSTALACIÓN, FUNCIONAMIENTO Y MANTENIMIENTO · Espacio requerido: 5 x 5 x 15 pulg. (13 x 13 x 38 cm) incluyendo
2-½ pulgadas de espacio libre debajo de la unidad para el cambio de cartucho. · Instale verticalmente con el cartucho suspendido hacia abajo. · Use el largo mínimo posible de tubería. · Lave el nuevo cartucho a caudal pleno durante tres minutos para purgar el aire. · Reemplace los cartuchos cuando alcancen su capacidad, o cuando el flujo baje demasiado, pero al menos cada año.

AVISOS ESPECIALES · Las instrucciones de instalación, la disponibilidad de piezas y
servicio, y la garantía estándar se incluyen con el producto cuando se envía. · Este sistema de agua potable se debe mantener según las instrucciones del fabricante, incluyendo el reemplazo de los cartuchos de filtro. Precio de lista sugerido: $100.99. · No se debe utilizar con agua microbiológicamente insegura o de calidad desconocida sin la desinfección adecuada previa o posterior al paso por el sistema. Los sistemas certificados para la reducción de quistes pueden usarse en aguas desinfectadas que pudieran contener quistes filtrables · Todas las sustancias contaminantes que este sistema de tratamiento de agua elimina o reduce, no están necesariamente presentes en el agua que usted consume. · Verifique el cumplimiento con las leyes y normas estatales y locales aplicables. · Se probó en condiciones estándar de laboratorio; el rendimiento en condiciones reales puede variar. · El medio de adsorción agotado no se regenerará y usará. · Si el medio de adsorción es afectado por el cloro, el suministro de agua se deberá tratar para eliminar el cloro antes de ingresar al filtro.

C US

El sistema está probado y certificado por NSF International bajo las normas CSA B483.1 y NSF/ANSI 42 y 53 en cuanto a las afirmaciones especificadas en la Hoja de datos sobre rendimiento.
EPA Est. No. 002623-IL-002

20 · EVERPURE Sistema De Filtración De Agua De La Serie H

and and

EVERPURE

HOJA DE INFORMACIÓN SOBRE RENDIMIENTO
SISTEMA DE AGUA POTABLE H-300

CARTUCHO H-300 – PIEZA N. EV9270-71, EV9270-72

AVISO IMPORTANTE: Lea esta Hoja de información sobre rendimiento y compare las capacidades de este sistema con sus necesidades reales de tratamiento de agua. Se recomienda que antes de adquirir una unidad de tratamiento de agua, haga analizar su agua para determinar sus necesidades reales de tratamiento del agua.

CARACTERÍSTICAS · Limpia adecuadamente el agua tratada y la convierte en agua
de calidad superior para beber o cocinar. · Reduce el gusto y el olor del cloro. · Reduce la suciedad, el óxido y otros materiales en partículas
como hierro oxidado, manganeso y sulfuros. · Con certificado de la Norma 53 de NSF/ANSI para reducir los
quistes como Cryptosporidium y Giardia por medios mecánicos. · Controla los niveles extremos de olores y sabores desagradables comunes, como a tierra, a moho o a pescado. · Reduce el nivel de plomo incluso por debajo de lo que marca el Nivel de recomendación federal (Federal Action Level). · Reduce eficazmente compuestos orgánicos volátiles (COV), incluso los trihalometanos (THM). · Reduce las partículas pequeñas, hasta de 0.5 micrones por medios mecánicos.

DATOS DE RENDIMIENTO DEL H-300
Este sistema ha sido analizado de acuerdo con las Normas NSF/ANSI 42 y 53 en cuanto a la reducción de las sustancias enumeradas a continuación. La concentración de las sustancias indicadas en el agua que entra al sistema se redujo a una concentración menor o igual a los límites permitidos para el agua que sale del sistema, como lo especifican las Normas NSF/ANSI 42 y 53.

Sustancia

Concentración de contaminantes en el
agua prefiltrada

Concentración máx. permitida de productos
el agua

enNerecdesuicdcaidónde

Reducción mínima

Reducción promedio

Estándar 42, efectos estéticos

Cloro

2.0 mg/L ± 10%

50%

86.8%

Partículas clase I 0.5 a <1 µm

al menos 10,000 partículas/ml

85%

98.8%

Estándar 53, efectos en la salud

Quistes

Mínimo 50,000/L

99.95%

99.99% 99.99%

Plomo 6.5

0.15 mg/L ± 10%

0.010 mg/L

99.3%

99.3%

Plomo 8.5

0.15 mg/L ± 10%

0.010 mg/L

98.7%

99.3%

Cloroformo

0.300 mg/L

0.015 mg/L

95.8%

98.9%

(químico sustituto de COV) *Analizado en un caudal de servicio = 0.5 gpm, presión = 60 psig, pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

C US

El H-300 está probado y certificado por NSF International bajo las normas CSA B483.1 y NSF/ANSI 42 y 53 en cuanto a las afirmaciones especificadas en la Hoja de datos sobre rendimiento

EPA Est. No. 002623-IL-002

NOTA: El medio de adsorción agotado no se regenerará y usará. Si el medio de adsorción es afectado por el cloro, el suministro de agua se deberá tratar para eliminar el cloro antes de ingresar al filtro.

ESPECIFICACIONES DE FUNCIONAMIENTO · Capacidad: 300 galones (1.135 litros) · Requisito de presión: 10-125 psi (0.7 – 8.6 bar), sin choque · Temperatura: 35-100°F (2°-38°C) · Caudal: 0.5 gpm (1.9 Lpm)
AFIRMACIONES DE REDUCCIÓN DE LA HOJA DE INFORMACIÓN SOBRE RENDIMIENTO PARA PRODUCTOS QUÍMICOS ORGÁNICOS INCLUIDOS MEDIANTE PRUEBAS DE SUSTITUTOS

Sustancia
alacloro atracina benceno carbofurano tetracloruro de carbono clorobenceno cloropicrina 2,4-D dibromocloropropano (DBCP) o-diclorobenceno p-diclorobenceno 1,2-dicloroetano 1,1-dicloroetileno cis-1,2-dicloroetileno trans-1,2-dicloroetileno 1,2-dicloropropano cis-1,3-dicloropropileno dinoseb endrina etilbenceno dibromuro de etileno (EDB) haloacetonitrilos (HAN):
bromocloroacetonitrilo dibromoacetonitrilo dicloroacetonitrilo tricloroacetonitrilo halocetonas (HK): 1,1-dicloro-2-propanona 1,1,1-tricloro-2-propanona
heptacloro epóxido de heptacloro hexaclorobutadieno hexaclorociclopentadieno lindano metoxicloro pentaclorofenol simazina estireno 1,1,2,2-tetracloroetano tetracloroetileno tolueno 2,4,5-TP (silvex) ácido tribromoacético 1,2,4-triclorobenceno 1,1,1-tricloroetano 1,1,2-tricloroetano tricloroetileno trihalometanos (incluye): cloroformo (químico sustituto) bromoformo bromodiclorometano clorodibromometano

Concentración de contaminantes en el agua prefiltrada mg/l 0.050 0.100 0.081 0.190 0.078 0.077 0.015 0.110 0.052 0.080 0.040 0.088 0.083 0.170 0.086 0.080 0.079 0.170 0.053 0.088 0.044
0.022 0.024 0.0096 0.015
0.0072 0.0082 0.025 0.0107 0.044 0.060 0.055 0.050 0.096 0.120 0.150 0.081 0.081 0.078 0.270 0.042 0.160 0.084 0.150 0.180
0.310

xilenos (total)

0.070

Concentración máx. permitida de productos en el agua mg/l
0.001 0.003 0.001 0.001 0.0018 0.001 0.0002 0.0017 0.00002 0.001 0.001 0.0048 0.001 0.0005 0.001 0.001 0.001 0.0002 0.00059 0.001 0.00002
0.0005 0.0006 0.0002 0.0003
0.0001 0.0003 0.00001 0.0002 0.001 0.000002 0.00001 0.0001 0.001 0.004 0.0005 0.001 0.001 0.001 0.0016 0.001 0.0005 0.0046 0.0005 0.001
0.015
0.001

EVERPURE Sistema De Filtración De Agua De La Serie H · 21

ESPAÑOL

EVERPURE

HOJA DE INFORMACIÓN SOBRE RENDIMIENTO
SISTEMA DE AGUA POTABLE H-1200

CARTUCHO H-1200 – PIEZA N. EV9282-01, EV9282-03

AVISO IMPORTANTE: Lea esta Hoja de información sobre rendimiento y compare las capacidades de este sistema con sus necesidades reales de tratamiento de agua. Se recomienda que antes de adquirir una unidad de tratamiento de agua, haga

ESPECIFICACIONES DE FUNCIONAMIENTO · Capacidad: 1,000 galones (3.785 litros) · Requisito de presión: 10-125 psi (0.7 – 8.6 bar), sin choque

analizar su agua para determinar sus necesidades reales de tratamiento del agua.
CARACTERÍSTICAS · Limpia adecuadamente el agua tratada y la convierte en agua
de calidad superior para beber o cocinar. · Con certificado de la Norma 53 de NSF/ANSI para reducir los
quistes como Cryptosporidium y Giardia por

· Temperatura: 35-100°F (2°-38°C) · Caudal: 0.5 gpm (1.9 Lpm)
AFIRMACIONES DE REDUCCIÓN DE LA HOJA DE INFORMACIÓN SOBRE RENDIMIENTO PARA PRODUCTOS QUÍMICOS ORGÁNICOS INCLUIDOS MEDIANTE PRUEBAS DE SUSTITUTOS

medios mecánicos. · Reduce la suciedad, el óxido y otros materiales en partículas
como hierro oxidado, manganeso y sulfuros, como comprobó Everpure. · Sistema de alto rendimiento certificado para reducir hasta el

Sustancia
alacloro atracina

Concentración de contaminantes en el agua prefiltrada mg/l
0.050
0.100

Concentración máx. permitida de productos en el agua mg/l
0.001 0.003

97,5% de PFOA/PFOS, comúnmente conocidos como “químicos para siempre”. · Controla los niveles extremos de olores y sabores desagradables comunes, como a tierra, a moho o a pescado.

benceno carbofurano tetracloruro de carbono clorobenceno cloropicrina

0.081 0.190 0.078 0.077 0.015

0.001 0.001 0.0018 0.001 0.0002

ESPAÑOL

· Reduce el nivel de plomo incluso por debajo de lo que marca el Nivel de recomendación federal (Federal Action Level) de 15 ppb.
· Reduce eficazmente compuestos orgánicos volátiles (COV),

2,4-D dibromocloropropano (DBCP) o-diclorobenceno p-diclorobenceno 1,2-dicloroetano

0.110 0.052
0.080 0.040 0.088

0.0017 0.00002 0.001 0.001 0.0048

incluso los trihalometanos (THM). · Reduce eficazmente el metil terbutil éter (MTBE). · Reduce las partículas pequeñas, hasta de 0.5 micrones

1,1-dicloroetileno cis-1,2-dicloroetileno trans-1,2-dicloroetileno 1,2-dicloropropano

0.083 0.170 0.086 0.080

0.001 0.0005 0.001 0.001

por medios mecánicos.

cis-1,3-dicloropropileno

0.079

0.001

DATOS DE RENDIMIENTO DEL H-1200

dinoseb endrina

0.170 0.053

0.0002 0.00059

Este sistema ha sido analizado de acuerdo con las Normas NSF/ANSI 42 y 53 en cuanto a la reducción de las sustancias enumeradas a continuación. La concentración de las sustancias indicadas en el agua que entra al sistema se redujo a una concentración menor o igual a los límites permitidos para el agua que sale del sistema, como lo especifican las Normas NSF/ANSI 42 y 53.

etilbenceno
dibromuro de etileno (EDB) haloacetonitrilos (HAN):
bromocloroacetonitrilo dibromoacetonitrilo dicloroacetonitrilo tricloroacetonitrilo
halocetonas (HK): 1,1-dicloro-2-propanona 1,1,1-tricloro-2-propanona

0.088 0.044
0.022 0.024 0.0096 0.015
0.0072 0.0082

0.001 0.00002
0.0005 0.0006 0.0002 0.0003
0.0001 0.0003

Sustancia

Concentración de contaminantes en el
agua prefiltrada

Concentración máx. permitida de productos
el agua

enNerecdesuicdcaidónde

Reducción mínima

Reducción promedio

Estándar 42, efectos estéticos

Cloro

2.0 mg/L ± 10%

50%

86.8%

heptacloro epóxido de heptacloro hexaclorobutadieno hexaclorociclopentadieno lindano

0.080 0.0107 0.044 0.060 0.055

0.0004 0.0002 0.001 0.000002 0.00001

Cloramina

3.0 mg/L ± 10%

0.5 mg/L

98.3%

metoxicloro

0.050

0.0001

Partículas clase I 0.5 a <1 µm

al menos 10,000 partículas/ml

Estándar 53, efectos en la salud

85%

98.8%

pentaclorofenol simazina estireno 1,1,2,2-tetracloroetano tetracloroetileno

0.096 0.120 0.150 0.081 0.081

0.001 0.004 0.0005 0.001 0.001

Quistes

Mínimo 50,000/L

99.95%

99.99% 99.99%

tolueno

0.078

0.001

Plomo 6.5

0.15 mg/L ± 10%

0.010 mg/L

nd

Plomo 8.5

0.15 mg/L ± 10%

0.010 mg/L

99.3% 98.7%

99.3% 99.3%

2,4,5-TP (silvex) ácido tribromoacético 1,2,4-triclorobenceno

0.270 0.042 0.160

0.0016 0.001 0.0005

Metil terbutil éter (MTBE)

0.015 mg/L ± 20%

0.005 mg/L

73.5%

90.2%

1,1,1-tricloroetano 1,1,2-tricloroetano

0.084 0.150

0.0046 0.0005

Cloroformo

0.300 mg/L

0.015 mg/L

99.8%

99.8%

tricloroetileno

0.180

0.001

d

PFOA/PFOS 0.0015 mg/L ± 10%

0.00007mg/L

95.76% 97.57%

trihalometanos (incluye): cloroformo (químico sustituto)

(químico sustituto de COV)

bromoformo

*Analizado en un caudal de servicio = 0.5 gpm, presión = 60 psig, pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

bromodiclorometano clorodibromometano

0.300

0.015

C US

El H-1200 está probado y certificado por NSF International bajo las normas CSA B483.1 y NSF/ANSI 42 y 53 en cuanto a las afirmaciones especificadas en la Hoja de datos sobre rendimiento.
EPA Est. No. 002623-IL-002

xilenos (total)

0.070

0.001

NOTA: El medio de adsorción agotado no se regenerará y usará. Si el medio de adsorción es afectado por el cloro, el suministro de agua se deberá tratar para eliminar el cloro antes de ingresar al filtro.

22 · EVERPURE Sistema De Filtración De Agua De La Serie H

and and

EVERPURE

HOJA DE INFORMACIÓN SOBRE RENDIMIENTO
SISTEMA DE AGUA POTABLE H-300-HSD

CARTUCHO H-300-HSD – PIEZA N. EV9270-74, EV9270-75

AVISO IMPORTANTE: Lea esta Hoja de información sobre rendimiento y compare las capacidades de este sistema con sus necesidades reales de tratamiento de agua. Se recomienda que antes de adquirir una unidad de tratamiento de agua, haga analizar su agua para determinar sus necesidades reales de tratamiento del agua.

CARACTERÍSTICAS · Para agua con alta densidad de sedimento respecto al
H-300 estándar. · Limpia adecuadamente el agua tratada y la convierte en agua
de calidad superior para beber o cocinar. · Reduce el gusto y el olor del cloro. · Reduce la suciedad, el óxido y otros materiales en partículas
como hierro oxidado, manganeso y sulfuros. · Con certificado de la Norma 53 de NSF/ANSI para reducir los
quistes como Cryptosporidium y Giardia por medios mecánicos. · Controla los niveles extremos de olores y sabores desagradables comunes, como a tierra, a moho o a pescado. · Reduce el nivel de plomo incluso por debajo de lo que marca el Nivel de recomendación federal (Federal Action Level) de 15 ppb. · Reduce eficazmente compuestos orgánicos volátiles (COV). · Reduce las partículas pequeñas, hasta de 0.5 micrones por medios mecánicos.

DATOS DE RENDIMIENTO DEL H-300-HSD

Este sistema ha sido analizado de acuerdo con las Normas NSF/ANSI 42 y 53 en cuanto a la reducción de las sustancias enumeradas a continuación. La concentración de las sustancias indicadas en el agua que entra al sistema se redujo a una concentración menor o igual a los límites permitidos para el agua que sale del sistema, como lo especifican las Normas NSF/ANSI 42 y 53.

Sustancia

Concentración de contaminantes en el
agua prefiltrada

Concentración máx. permitida de productos
el agua

enNerecdesuicdcaidónde

Reducción mínima

Reducción promedio

Estándar 42, efectos estéticos

Cloro

2.0 mg/L ± 10%

50%

86.8%

Partículas clase I 0.5 a <1 µm

al menos 10,000 partículas/ml

85%

98.8%

Estándar 53, efectos en la salud

Quistes

Mínimo 50,000/L

99.95%

99.99% 99.99%

Plomo 6.5

0.15 mg/L ± 10%

0.010 mg/L

99.3%

99.3%

Plomo 8.5

0.15 mg/L ± 10%

0.010 mg/L

98.7%

99.3%

Cloroformo

0.300 mg/L

0.015 mg/L

95.8%

98.9%

(químico sustituto de COV) *Analizado en un caudal de servicio = 0.5 gpm, presión = 60 psig, pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

C US

El H-300-HSD está probado y certificado por NSF International bajo las normas CSA B483.1 y NSF/ANSI 42 y 53 en cuanto a las afirmaciones especificadas en la Hoja de datos sobre rendimiento.

EPA Est. No. 002623-IL-002

NOTA: El medio de adsorción agotado no se regenerará y usará. Si el medio de adsorción es afectado por el cloro, el suministro de agua se deberá tratar para eliminar el cloro antes de ingresar al filtro.

ESPECIFICACIONES DE FUNCIONAMIENTO · Capacidad: 300 galones (1.135 litros) · Requisito de presión: 10-125 psi (0.7 – 8.6 bar), sin choque · Temperatura: 35-100°F (2°-38°C) · Caudal: 0.5 gpm (1.9 Lpm)
AFIRMACIONES DE REDUCCIÓN DE LA HOJA DE INFORMACIÓN SOBRE RENDIMIENTO PARA PRODUCTOS QUÍMICOS ORGÁNICOS INCLUIDOS MEDIANTE PRUEBAS DE SUSTITUTOS

Sustancia
alacloro atracina benceno carbofurano tetracloruro de carbono clorobenceno cloropicrina 2,4-D dibromocloropropano (DBCP) o-diclorobenceno p-diclorobenceno 1,2-dicloroetano 1,1-dicloroetileno cis-1,2-dicloroetileno trans-1,2-dicloroetileno 1,2-dicloropropano cis-1,3-dicloropropileno dinoseb endrina etilbenceno dibromuro de etileno (EDB) haloacetonitrilos (HAN):
bromocloroacetonitrilo dibromoacetonitrilo dicloroacetonitrilo tricloroacetonitrilo halocetonas (HK): 1,1-dicloro-2-propanona 1,1,1-tricloro-2-propanona
heptacloro epóxido de heptacloro hexaclorobutadieno hexaclorociclopentadieno lindano metoxicloro pentaclorofenol simazina estireno 1,1,2,2-tetracloroetano tetracloroetileno tolueno 2,4,5-TP (silvex) ácido tribromoacético 1,2,4-triclorobenceno 1,1,1-tricloroetano 1,1,2-tricloroetano tricloroetileno trihalometanos (incluye): cloroformo (químico sustituto) bromoformo bromodiclorometano clorodibromometano

Concentración de contaminantes en el agua prefiltrada mg/l 0.050 0.100 0.081 0.190 0.078 0.077 0.015 0.110 0.052 0.080 0.040 0.088 0.083 0.170 0.086 0.080 0.079 0.170 0.053 0.088 0.044
0.022 0.024 0.0096 0.015
0.0072 0.0082 0.080 0.0107 0.044 0.060 0.055 0.050 0.096 0.120 0.150 0.081 0.081 0.078 0.270 0.042 0.160 0.084 0.050 0.180
0.310

xilenos (total)

0.070

Concentración máx. permitida de productos en el agua mg/l
0.001 0.003 0.001 0.01 0.0018 0.001 0.0002 0.0017 0.00002 0.001 0.001 0.0048 0.001 0.0005 0.001 0.001 0.001 0.0002 0.00059 0.001 0.00002
0.0005 0.0006 0.0002 0.0003
0.0001 0.0003 0.0004 0.0002 0.001 0.000002 0.00001 0.0001 0.001 0.004 0.0005 0.001 0.001 0.001 0.0016 0.001 0.0005 0.0046 0.0005 0.001
0.015
0.001

EVERPURE Sistema De Filtración De Agua De La Serie H · 23

ESPAÑOL

EVERPURE

HOJA DE INFORMACIÓN SOBRE RENDIMIENTO
SISTEMA DE AGUA POTABLE H-300 NXT

ESPAÑOL

CARTUCHO H-300-NXT – PIEZA N. EV927441, EV927446

AVISO IMPORTANTE: Lea esta Hoja de información sobre rendimiento Everpure y compare las capacidades de este sistema con sus necesidades reales de tratamiento de agua. Se recomienda que antes de adquirir una unidad de tratamiento de agua, haga analizar su agua para determinar sus necesidades reales de tratamiento del agua.

CARACTERÍSTICAS · Limpia adecuadamente el agua tratada y la convierte en agua
de calidad superior para beber o cocinar. · Reduce el gusto y el olor del cloro. · Reduce la suciedad, el óxido y otros materiales en partículas
como hierro oxidado, manganeso y sulfuros, como comprobó Pentair. · Con certificado de la Norma 53 de NSF/ANSI para reducir los quistes como Cryptosporidium y Giardia por medios mecánicos. · Controla los niveles extremos de olores y sabores desagradables comunes, como a tierra, a moho o a pescado. · Reduce el plomo. · Reduce eficazmente compuestos orgánicos volátiles (COV). · Reduce las partículas pequeñas, hasta de 0.5 micrones por medios mecánicos. · Certificado según la Norma 401 de NSF/ANSI en cuanto a la reducción de los compuestos contaminantes /emergentes incidentales indicados en la hoja de información sobre rendimiento.

DATOS DE RENDIMIENTO DEL H-300 NXT

Este sistema ha sido analizado de acuerdo con las Normas NSF/ ANSI 42, 53, y 401 en cuanto a la reducción de las sustancias enumeradas a continuación. La concentración de las sustancias indicadas en el agua que entra al sistema se redujo a una concentración menor o igual a los límites permitidos para el agua que sale del sistema, como lo especifican las Normas NSF/ANSI 42, 53 y 401.

Sustancia

Concentración de contaminantes en el agua prefiltrada

Concentración máx. permitida de productos
en el agua

Necesidad de reducción

Estándar 42, efectos estéticos

Cloro

2.0 mg/L ± 10%

50%

Partículas clase I 0.5 a <1 µm

al menos 10,000 partículas/ml

85%

Reducción mínima

Reducción promedio
86.8% 98.8%

Estándar 53, efectos en la salud

Quistes

Mínimo 50,000/L

99.95%

99.99%

99.99%

Plomo 6.5

0.15 mg/L ± 10%

0.010 mg/L

99.3%

99.3%

Plomo 8.5

0.15 mg/L ± 10%

0.010 mg/L

98.7%

99.3%

Cloroformo

0.300 mg/L

0.015 mg/L

95.8%

98.9%

(químico sustituto de COV)
H-104 PERFORMANCE DATA *Analizado en un caudal de servicio = 0.5 gpm, presión = 60 psig, pH = 7.5 ± 0.5; temp. = 20° ± 2.5°C

Norma 401–Contaminantes emergentes

Fenitoína

200 ± 20% ng/L

0.000030 mg/L

42 and

96.3%

Ibuprofeno

400 ± 20% ng/L

0.000060 mg/L

95.8%

Naproxeno

140 ± 20% ng/L

0.000020 mg/L

96.8%

Estrona Bisfenol A (BPA)

140 ± 20% ng/L 2,000 ± 20% ng/L

0.000020 mg/L 0.000300 mg/L

97.2%
42 and >99.2%

Nonilfenol

1,400 ± 20% ng/L

0.000200 mg/L

97.1%

La Norma 401 de NSF/ANSI se considera como “los compuestos contaminantes /emergentes incidentales”. Los contaminantes incidentales son aquellos compuestos que se han detectado en suministros de agua potable en niveles de trazas. Aunque solo se presenten en niveles de trazas, estos compuestos pueden afectar la aceptación o percepción del público de la calidad del agua potable.

NOTA: El medio de adsorción agotado no se regenerará y usará. Si el medio de adsorción es afectado por el cloro, el suministro de agua se deberá tratar para eliminar el cloro antes de ingresar al filtro.

24 · EVERPURE Sistema De Filtración De Agua De La Serie H

ESPECIFICACIONES DE FUNCIONAMIENTO · Capacidad: 300 galones (1.136 litros) · Requisito de presión: 10-125 psi (0.7 – 8.6 bar), sin choque · Temperatura: 35-100°F (2°-38°C) · Caudal: 0.5 gpm (1.9 Lpm)

AFIRMACIONES DE REDUCCIÓN DE LA HOJA DE INFORMACIÓN SOBRE RENDIMIENTO PARA PRODUCTOS QUÍMICOS ORGÁNICOS INCLUIDOS MEDIANTE PRUEBAS DE SUSTITUTOS

Sustancia
alacloro atracina benceno carbofurano tetracloruro de carbono clorobenceno cloropicrina 2,4-D dibromocloropropano (DBCP) o-diclorobenceno p-diclorobenceno 1,2-dicloroetano 1,1-dicloroetileno cis-1,2-dicloroetileno trans-1,2-dicloroetileno 1,2-dicloropropano cis-1,3-dicloropropileno dinoseb endrina etilbenceno dibromuro de etileno (EDB) haloacetonitrilos (HAN):
bromocloroacetonitrilo dibromoacetonitrilo dicloroacetonitrilo tricloroacetonitrilo halocetonas (HK): 1,1-dicloro-2-propanona 1,1,1-tricloro-2-propanona
heptacloro epóxido de heptacloro hexaclorobutadieno hexaclorociclopentadieno lindano metoxicloro pentaclorofenol simazina estireno 1,1,2,2-tetracloroetano tetracloroetileno tolueno 2,4,5-TP (silvex) ácido tribromoacético 1,2,4-triclorobenceno 1,1,1-tricloroetano 1,1,2-tricloroetano tricloroetileno trihalometanos (incluye): cloroformo (químico sustituto) bromoformo bromodiclorometano clorodibromometano

Concentración de contaminantes en el agua prefiltrada mg/l 0.050 0.100 0.081 0.190 0.078 0.077 0.015 0.110 0.052 0.080 0.040 0.088 0.083 0.170 0.086 0.080 0.079 0.170 0.053 0.088 0.044
0.022 0.024 0.0096 0.015
0.0072 0.0082 0.080 0.0107 0.044 0.060 0.055 0.050 0.096 0.120 0.150 0.081 0.081 0.078 0.270 0.042 0.160 0.084 0.150 0.180
0.300

Concentración máx. permitida de productos en el agua mg/l
0.001 0.003 0.001 0.001 0.0018 0.001 0.0002 0.0017 0.00002 0.001 0.001 0.0048 0.001 0.0005 0.001 0.001 0.001 0.0002 0.00059 0.001 0.00002
0.0005 0.0006 0.0002 0.0003
0.0001 0.0003 0.0004 0.0002 0.001 0.000002 0.00001 0.0001 0.001 0.004 0.0005 0.001 0.001 0.001 0.0016 0.001 0.0005 0.0046 0.0005 0.001
0.015

xilenos (total)

0.070

0.001

El H-300-NXT está probado y certificado por NSF International bajo las normas CSA B483.1 y NSF/ ANSI 42, 53, y 401 en cuanto a las afirmaciones C US especificadas en la Hoja de datos sobre
EPA Est. No. 002623-IL-002

Everpure* vous remercie de votre achat d’un filtre de qualité

le règlement américain de la plomberie

professionnelle pour votre logement. Avec votre système Everpure, votre famille et vous pourrez facilement tirer directement à votre robinet, de l’eau de qualité supérieure au goût.

(Universal Plumbing Code) adopté par plus de 20 états ainsi que d’autres règlements spécifiques à certaines villes ou à certains contés interdit l’usage de robinets à étrier, et en tout état de cause, leur utilisation n’est jamais recommandée. Vous devez suivre les règlements de plomberie de votre état ainsi que ceux de votre

Caractéristiques Techniques Du Produit:

localité. Consultez un plombier qualifié si vous avez des questions à

· Pour usage sur eau froide uniquement

ce sujet.

· Gammes de températures : 2 à 38°C · Pression utile mini. ­ maxi. : 0.7-8.6 bar

n’utilisez PAS de tubes de cuivre avec les raccords de type John Guest fournis avec votre système de filtrage

· Débit de service : 1.9 Lpm
LE GUIDE DE L’UTILISATEUR S’APPLIQUE AUX FILTRES EVERPURE DES MODÈLES SUIVANTS :

Everpure. Le tube de cuivre pourrait donner l’impression de convenir, mais des fuites d’eau se développeront à l’usage ou au bout d’un certain temps. Si vous devez utiliser du tube en cuivre, il vous faut alors employer des raccords cuivre à compression disponibles dans

Modèle H-54 Capacité nominale : 750 Gal (2,839 L)*

toutes les quincailleries ou fournisseurs de plomberie.

Modèle H-300 Capacité nominale : 300 Gal (1,136 L)*

Modèle H-104 Capacité nominale : 1,000 Gal (3,785 L) Modèle H-300-HSD Capacité nominale : 300 Gal (1,136 L)

Raccordement à plusieurs appareils : vous pouvez également raccorder votre filtre Everpure au réfrigérateur pour la distribution

Modèle H-300-NXT Capacité nominale : 300 Gal (1,136 L) Modèle H-1200 Capacité nominale : 1,000 Gal (3,785 L)

d’eau et de glace, à un distributeur d’eau chaude instantanée, à un refroidisseur ou à une cafetière raccordée à l’arrivée d’eau. Il vous suffit d’installer des raccords en Té (disponibles dans toutes

*Pour maximiser la performance, il convient de

les quincailleries ou fournisseurs de plomberie) dans la ligne

remplacer la cartouche une fois par an ou plus souvent si d’alimentation en eau entre le filtre et l’adaptateur du robinet puis

le débit ralentit trop ou si la capacité nominale de l’unité d’amener un tuyau à chaque appareil.

est dépassée Pour l’achat de composants remplaçables s’il vous plaît contacter votre distributeur local. Clients de l’H-1200 : Les consignes d’installation du H-1200 commencent à la page no 28 de ce guide d’installation et d’utilisation.

REMARQUE : NE raccordez PAS ce système à une machine à glaçons commerciale. Ce type d’appareil nécessite un débit et un volume d’eau supérieurs aux limites pour lesquelles votre filtre sous évier a été conçu. REMARQUE : Si vous le raccordez à une machine à glaçons domestique et qu’il n’y a pas de raccordement à un robinet de filtre sous l’évier, il faut prévoir un robinet de purge.

FRANÇAIS

EVERPURE H Série Système De Filtrage D’eau · 25

INSTRUCTIONS D’INSTALLATION DE BASE
Outils nécessaires Tournevis #2 Phillips · Clé · Couteau · Mètre à ruban · Crayon de bois

1. OUVREZ LE CARTON ET INSPECTEZ LES PIÈCES Pièces à installer

Repère Description

No de pièce

1

QL3 Tête de filtre

(Quantité incluse 2 chacun

des n 3 et 4 )

EV925831

2

Cartouche filtrante

(incluse 10 )

­ Modèle H-54

EV925268

­ Modèle H-300

EV927072

­ Modèle H-104

EV961211

­ Modèle H-300-HSD

EV927075

­ Modèle H-300-NXT

EV927441

3

Rondelles de blocage

(requis 2)

EV306204

4

Vis (requis 2)

EV306196

5

Adaptateur de robinet

d’arrêt d’équerre

EV312120

6

Tube plastique 1/4 po

(por 30.48 cm)

A0860119

7

Raccord coudé et réducteur EV308168

(Quantité incluse 2 chacun

des n 3 et 4 )

8

Sparadrap

EV312119

9

Raccord de robinet

EV312135

10

Compteur du filtre Everpure

EV314160

2. VÉRIFIEZ L’EMPLACEMENT DE MONTAGE SOUS L’ÉVIER Mesurez 55.8 cm par rapport au bas du placard et repérez l’emplacement de montage du dessus de la tête de filtre. Assurez-vous qu’il y a assez d’espace au-dessus de la tête pour ouvrir et fermer le robinet d’arrêt intégré et pour éviter de faire un pli dans le tuyau d’arrivée d’eau. Assurez-vous également que l’emplacement choisi permet un accès facile pour changer les cartouches dans le futur.

Dimensions

Largeur

Hauteur Profondeur

H-54

12.7 cm

38.1 cm

12.7 cm

H-104

12.7 cm

50.8 cm

12.7 cm

H-300

12.7 cm

55.8 cm

12.7 cm

H-300-HSD

12.7 cm

55.8 cm

12.7 cm

H-300-NXT

12.7 cm

55.8 cm

12.7 cm

REMARQUE : la tête et la cartouche doivent être montées en position verticale avec la cartouche dirigée vers le bas.

1 1 2
2

4 3
5 7 6
10 8 9
55.8 cm

FRANÇAIS

26 · EVERPURE Sistema De Filtración De Agua De La Serie H

3. MONTAGE DE LA TÊTE DE FILTRE SOUS L’ÉVIER

A. Identifiez la tête de filtre et les deux raccords coudés et

3

remarquez que le raccord de sortie est doté d’une bague

B

noire. Ce raccord est muni d’un petit réducteur rapporté

pour limiter le débit à un maximum de 1,9 litres (0.5

gallon) par minute.

B. Enrobez les filets des raccords coudés de ruban Sparadrap. Enroulez le ruban dans le sens des filets

pour assurer un serrage convenable et éviter les petites

fuites.

C. Vissez le coude d’entrée sur le côté gauche de la tête filtrante et serrez à la main seulement.

E

D. Vissez le coude de sortie (bague noire) sur le côté droit de la tête filtrante de la même manière.

E. Montez fermement la tête de filtre sur la paroi du placard à l’aide des vis et rondelles de montage fournies.

4. RACCORDEMENT DE L’ARRIVÉE D’EAU F. Localisez le robinet d’arrêt d’équerre d’eau froide sous votre évier de cuisine et fermez-le. G. Dévissez le tube armé du dessus du robinet d’arrêt d’équerre et débranchez-le. H. Fixez la partie inférieure de l’adaptateur de robinet d’arrêt d’équerre sur le robinet d’arrêt d’équerre d’eau froide existant. I. Raccordez le tube armé à la partie supérieure de l’adaptateur de robinet d’arrêt d’équerre. J. Fermez le robinet latéral de l’adaptateur de robinet d’arrêt d’équerre et ouvrez le robinet d’arrêt d’équerre d’eau froide pour rétablir l’arrivée d’eau à l’évier. Vérifiez qu’il n’y a pas de fuites.
REMARQUE : il n’est pas nécessaire d’utiliser de ruban Fontanero pour les étapes qui suivent. K. Mesurez la longueur de tube nécessaire pour raccorder l’adaptateur de robinet d’arrêt d’équerre au coude d’entrée de la tête filtrante. Prévoyez suffisamment de longueur pour éviter les coudes brusques. L. Coupez le tube d’équerre à l’aide d’un couteau bien aiguisé. M. Enfoncez les extrémités du tube dans les raccords rapides. Poussez le tube dans le raccord et tirez doucement dessus pour confirmer qu’il est bien assujetti.

4 G

5. RACCORDEMENT DE L’EAU FILTRÉE AU ROBINET DE L’ÉVIER

N. Installez un robinet séparé pour l’eau potable filtrée. Suivez les instructions du fabricant.

O. Raccordez le raccord de robinet à la partie inférieure des filets du robinet qui vient d’être installé. Il ne devrait pas

L

être nécessaire d’utiliser du ruban Fontanero pour cette

étape.

P. Mesurez la longueur de tube nécessaire pour raccorder le coude de sortie de la tête filtrante au raccord de robinet

qui vient d’être installé. Prévoyez suffisamment de

longueur pour éviter les coudes brusques. Coupez le tube

et insérez les deux extrémités dans les raccords.

6. INSTALLATION ET RINÇAGE DE LA CARTOUCHE FILTRANTE

Q. Mettez la poignée du robinet d’arrêt intégré (robinet de

contrôle) situé sur la tête en position haute.

5

N

O

C

D

F I
H M
P

FRANÇAIS

EVERPURE H Série Système De Filtrage D’eau · 27

R. Tenez fermement la tête d’une main.
S. Mettez la patte de la cartouche en face de l’étiquette située sur la tête de filtre.
T. Enfoncez la cartouche filtrante en poussant vers le haut.
U. Faites-la tourner vers la droite d’environ 1/4 tour jusqu’à ce qu’elle butte.
V. Ouvrez le robinet d’arrêt d’eau froide et vérifiez qu’il n’y a pas de fuites jusqu’au coude d’entrée.
W. Ouvrez le robinet.
X. Mettez la poignée du robinet d’arrêt en position basse pour évacuer l’eau dans l’évier.
REMARQUE : Rincez les cartouches filtrantes neuves pendant un minimum de 5 minutes pour éliminer l’air et les particules de carbone libres. Au début, il se peut que l’eau apparaisse laiteuse à cause de la présence d’air dans le filtre et les tuyaux. Si l’eau reste laiteuse après une semaine, veuillez contacter le services d’assistance technique d’Everpure pour assistance 800-942-1153.
Y. Activez le compteur du filtre en pinçant la bulle jusqu’à sentir un changement dans la résistance et jusqu’à ce que le temporisateur de filtre soit éjecté. En quelques secondes une ligne ROUGE fine apparaîtra dans la fenêtre blanche indiquant que le Timestrip a été activé. Décollez la pellicule de protection et faites adhérer à l’emplacement désiré. Quand la fenêtre blanche est complètement remplie de ROUGE, il est temps de remplacer le produit.

6 V Y

Q S
R T

Étiquette Patte

W

U X

CONSIGNES D’UTILISATION POUR L’H-1200
Outils nécessaires · Tournevis #2 Phillips · Clé · Couteau · Mètre à ruban · Crayon de bois

1. OUVREZ LE CARTON ET INSPECTEZ LES PIÈCES Pièces à installer

Key

Description

Part No.

1

QL3 Tête de filtre

N/A

2

H-1200 Cartouche filtrante

(Lot de 2) (comprend 10 )

EV928201

3

Rondelles de blocage (requis 2)

EV306204

4

Vis (requis 2)

EV306196

5

Adaptateur de robinet d’arrêt d’équerre

EV312120

6

Tube plastique 1/4 po

(por 30.48 cm)

A0860119

7

Raccord coudé et réducteur

EV308168

8

Ruban Sparadrap

EV312119

9

Raccord de robinet

EV312135

10

Compteur du filtre Everpure

EV314160

11

Robinet d’arrêt, raccord type

John Guest 3/8 po x 3/8 po

EV309860

filetage gaz femelle.

28 · EVERPURE Sistema De Filtración De Agua De La Serie H

1

1

2

34

5

7

8

6

10

11

9

12

FRANÇAIS

12

Accouplement, 3/8 po

filetage gaz femelle, acier

EV312350

2

inoxydable

2. VÉRIFIEZ L’EMPLACEMENT DE MONTAGE SOUS L’ÉVIER Mesurez 55.8 cm par rapport au bas du placard et repérez l’emplacement de montage du dessus de la tête de filtre. Assurez-vous qu’il y a assez d’espace au-dessus de la tête pour ouvrir et fermer le robinet d’arrêt intégré et pour éviter de faire un pli dans le tuyau d’arrivée d’eau. Assurez-vous également que l’emplacement choisi permet un accès facile pour changer les cartouches dans le futur.

Dimensions H-1200

Largeur 12.7 cm

Hauteur Profondeur

3

55.8 cm

12.7 cm

REMARQUE : la tête et la cartouche doivent être montées en position verticale avec la cartouche dirigée vers le bas.

3. MONTAGE DE LA TÊTE DE FILTRE SOUS L’ÉVIER A. Identifiez la double tête filtrante et le robinet d’arrêt (EV309860). B. Appliquez du ruban Sparadrap sur les filets du côté entrée (gauche) de la tête. Vissez-y le nouveau robinet d’arrêt et serrez à la main. Répétez cette étape pour l’accouplement en inox (EV312350) du côté sortie (droit) de la tête. C. Appliquez du ruban Sparadrap sur les filets du coude de sortie (bague noire). Vissez-le sur la sortie de l’accouplement en inox. Enroulez le ruban dans le sens des filets pour assurer un bon serrage et éviter les petites fuites. D. Montez fermement la tête de filtre sur la paroi du placard à l’aide des vis et rondelles de montage fournies.
4. Allez à la page 27 et suivez les instructions d’installation de base, étapes 4, 5 et 6 pour terminer l’installation du système H-1200.

REVENDICATION & REMARQUES
L’installation doit être conforme à tous les règlements provinciaux et locaux en vigueur.
N’utilisez pas le filtre avec de l’eau qui est micro biologiquement impropre à la consommation ou de qualité inconnue sans une désinfection correcte avant ou après le système.
Essai effectué sous conditions normales de laboratoire, les performances réelles peuvent être différentes.

EPA Est. No. 002623-IL-002

55.8 cm

Dual Filter Head

A Shut Off Valve

B C

D

Les modèles H-54, H-300, H-104, H-300-HSD et H-1200 sont testés et certifiés par NSF International contre CSA B483.1 et NSF / ANSI 42 et 53 pour C US les revendications spécifiées sur les données de performance Drap.
Le H-300-NXT est testé et certifié par NSF International par rapport aux normes CSA B483.1 et NSF / ANSI 42, 53 et 401 pour les réclamations spécifiées sur la fiche C US technique de performance.
L’H-1200 est certifié par IAPMO R&T contre NSF/ANSI 53 pour la reduction de l’acide perfluorooctanoïque (PFOA) et du sulfonate de perfluorooctane (PFOS).

FRANÇAIS

EVERPURE H Série Système De Filtrage D’eau · 29

EVERPURE

FICHE TECHNIQUE DU PRODUIT
SYSTÈMES D’EAU POTABLE H-104

Cartouche H-104 ­ numéros de pièce EV9612-11 et EV9612-16

NOTICE IMPORTANTE : Lisez la présente fiche technique du produit et comparez les capacités du système à vos besoins de traitement d’eau. Il est recommandé de faire analyser l’eau d’alimentation avant d’acheter un système de traitement d’eau afin de déterminer vos besoins réels de traitement d’eau.
CARACTÉRISTIQUES
· Améliore en finesse de l’eau traitée afin d’en faire une eau de première qualité que l’on peut boire et utiliser pour cuisiner.
· Réduit le goût et l’odeur de chlore. · Réduit la quantité d’impuretés, de rouille et d’autres particules
(p. ex., fer oxydé, manganèse et sulfures). · Certifié selon la norme NSF/ANSI 53 pour réduire les kystes comme
Cryptosporidium et Giardia par des moyens mécaniques. · Réduit les goûts et odeurs courants de moisi, de terre et de poisson. · Réduit la quantité de plomb à un niveau moindre que le seuil
d’intervention fédéral. · Séparation mécanique des particules d’à peine 0,5 micron.

CERTIFIÉ CONFORME AUX NORMES NSF/ANSI RELATIVES À LA RÉDUCTION SANITAIRE DES SUBSTANCES INDIQUÉES*
Ce système a été mis à l’essai en regard des normes NSF/ANSI 42 et 53 pour la réduction des substances indiquées ci-dessous. La concentration des substances indiquées dans l’eau entrant dans le système a été réduite à une concentration inférieure ou égale à la limite autorisée pour l’eau sortant du système, conformément aux normes NSF/ANSI 42 et 53.

Substance

Concentration infiltrante

Norme 42 ­ Effets esthétiques

Chlore

2,0 mg/L ± 10 %

Concentration maximale admissible du produit dans l’eau

Exigences de Réduction Réduction réduction minimale moyenne

50 %

87,8%

Particules de classe 1, 0,5 à < 1 µm

Au moins 10 000 particules/ml

Norme 53 ­ Effets sur la santé

Kystes

Minimum de 50 000/L

85 %

98,8 %

99,95 %

99,99 %

99,99 %

Plomb (pH 8,5) 0,15 mg/L ± 10 % Plomb (pH 6,5) 0,15 mg/L ± 10 %

0,010 mg/L 0,010 mg/L

99,3 % 98,7 %

99,3 % 99,3 %

*Essais à un débit de 0,5 gal./min, à une pression de 60 lb/po², à un pH de 7.5 ± 0.5 et à une temp. de 20 ± 2,5 °C

EXIGENCES GÉNÉRALES EN MATIÈRE D’INSTALLATION, D’UTILISATION ET D’ENTRETIEN
· Espace requis : 13 x 13 x 51 cm (5 x 5 x 20 po), ce qui inclut un dégagement de 6,35 cm (2 ½ po) sous le système pour permettre le remplacement de la cartouche.
· Installez le système à la verticale avec la cartouche pendant vers le bas.
· Utilisez la plus courte longueur de tuyau possible. · Rincez la nouvelle cartouche à plein débit pendant trois minutes afin
d’en chasser tout l’air. · Remplacez les cartouches au moins une fois par année, ou lorsque
leur capacité est atteinte ou que le débit ralentit trop.
NOTICES SPÉCIALES
· Les instructions d’installation, l’information faisait état des pièces disponibles et du service offert ainsi que la garantie standard sont comprises avec le produit.
· Ce système d’eau potable doit être entretenu conformément aux directives du fabricant, y compris le remplacement des cartouches filtrantes. Prix de détail suggéré : 122,99 $
· N’utilisez pas le système avec de l’eau insalubre microbiologiquement ou de qualité inconnue sans désinfection adéquate avant ou après le système. Les systèmes homologués pour réduction de kystes peuvent être utilisés avec de l’eau désinfectée pouvant contenir des kystes filtrables.
· Les contaminants ou autres substances retirées ou réduites par ce système de traitement d’eau ne sont pas forcément présents dans votre eau.
· Assurez-vous que l’installation est conforme aux lois et aux règlements d’État et municipaux.
· Les essais ont été effectués dans des conditions de laboratoire standard; la performance réelle peut varier.
· Un produit d’absorption utilisé ne sera pas regénéré afin d’être réutilisé.
· Si un produit d’absorption est affecté par le chlore, l’alimentation en eau devrait être traitée afin d’éliminer le chlore avant d’introduire le filtre.
Système mis à l’essai et homologué par NSF International en regard des normes CSA B483.1 et NSF/ANSI 42 et 53 pour la réduction des substances indiquées dans la fiche technique du produit. C US

CARACTÉRISTIQUES DE FONCTIONNEMENT
· Capacité : 3,780 L (1 000 gallons) · Pression requise : de 0,7 à 8,6 bar (10 à 125 lb/po²), sans chocs · Température : de 2 à 38 °C (35 à 100 °F) · Débit : 1,9 L/min (0,5 gal./min)

NUMÉRO D’ÉTABLISSEMENT DE L’EPA 002623-IL-002

FRANÇAIS

30 · EVERPURE Sistema De Filtración De Agua De La Serie H

EVERPURE

FICHE TECHNIQUE DU PRODUIT
SYSTÈME D’EAU POTABLE H-54

Cartouche H-54 ­ numéros de pièce EV9730-06, EV9252-68, EV9252-66 et EV9252-67

NOTICE IMPORTANTE : Lisez la présente fiche technique du produit EXIGENCES GÉNÉRALES EN MATIÈRE D’INSTALLATION,

et comparez les capacités du système à vos besoins de traitement D’UTILISATION ET D’ENTRETIEN

d’eau. Il est recommandé de faire analyser l’eau d’alimentation avant d’acheter un système de traitement d’eau afin de déterminer vos besoins réels de traitement d’eau.

· Espace requis : 13 x 13 x 38 cm (5 x 5 x 15 po), ce qui inclut un dégagement de 6,35 cm (2 ½ po) sous le système pour permettre le remplacement de la cartouche.

CARACTÉRISTIQUES
· Améliore en finesse de l’eau traitée afin d’en faire une eau de première qualité que l’on peut boire et utiliser pour cuisiner.
· Réduit le goût et l’odeur de chlore. · Réduit la quantité d’impuretés, de rouille et d’autres particules
(p. ex., fer oxydé, manganèse et sulfures). · Certifié selon la norme NSF/ANSI 53 pour réduire les kystes comme
Cryptosporidium et Giardia par des moyens mécaniques.

· Installez le système à la verticale avec la cartouche pendant vers le bas.
· Utilisez la plus courte longueur de tuyau possible. · Rincez la nouvelle cartouche à plein débit pendant trois minutes afin
d’en chasser tout l’air. · Remplacez les cartouches au moins une fois par année, ou lorsque
leur capacité est atteinte ou que le débit ralentit trop.
NOTICES SPÉCIALES

· Absorbe les goûts et odeurs courants de moisi, de terre et de

· Les instructions d’installation, l’information relative à la disponibilité

poisson.

des pièces et du service offert ainsi que la garantie standard sont

· Réduit la quantité de plomb à un niveau moindre que le seuil

comprises avec le produit lorsqu’il est expédié.

d’intervention fédéral de 10 parties par milliard (ppb).

· Ce système d’eau potable doit être entretenu conformément aux

· Séparation mécanique des particules d’à peine 0,5 micron.

directives du fabricant, y compris le remplacement des cartouches

filtrantes. Prix courant suggéré : 100,99 $

· N’utilisez pas le système avec de l’eau insalubre

CERTIFIÉ CONFORME AUX NORMES NSF/ANSI RELATIVES À LA RÉDUCTION SANITAIRE DES SUBSTANCES INDIQUÉES*

microbiologiquement ou de qualité inconnue sans désinfection adéquate avant ou après le système. Les systèmes homologués pour réduction de kystes peuvent être utilisés avec de l’eau désinfectée

Ce système a été mis à l’essai en regard des normes NSF/ANSI 42

pouvant contenir des kystes filtrables.

et 53 pour la réduction des substances indiquées ci-dessous. La

· Les contaminants ou autres substances retirées ou réduites par ce

concentration des substances indiquées dans l’eau entrant dans le

système de traitement d’eau ne sont pas forcément présents dans

système a été réduite à une concentration inférieure ou égale à la

votre eau.

limite autorisée pour l’eau sortant du système, conformément aux · Assurez- vous que l’installation est conforme aux lois et aux

normes NSF/ANSI 42 et 53.

règlements d’État et municipaux.

Substance

Concentration infiltrante

Norme 42 ­ Effets esthétiques

Chlore

2,0 mg/L ± 10 %

Concentration maximale admissible du produit dans l’eau

Exigences de réduction
50 %

Réduction minimale

· Les essais ont été effectués dans des conditions de laboratoire

Réduction moyenne

standard; la performance réelle peut varier.

· Un produit d’absorption utilisé ne sera pas regénéré afin d’être

86,8 %

réutilisé.

· Si un produit d’absorption est affecté par le chlore, l’alimentation en

Particules de classe 1, 0,5 à < 1 µm

Au moins 10 000 particules/ml

eau devrait être traitée afin d’éliminer le chlore avant d’introduire le

85 %

98,8 %

filtre.

Norme 53 ­ Effets sur la santé

Kystes

Minimum de 50 000/L

99,95 %

99,99 %

99,99 %

Plomb (pH 8,5) 0,15 mg/L ± 10 % Plomb (pH 6,5) 0,15 mg/L ± 10 %

0,010 mg/L 0,010 mg/L

98,7 % 99,3 %

99,3 % 99,3 %

*Essais à un débit de 0,5 gal./min, à une pression de 60 lb/po², à un pH de 7.5 ± 0.5 et à une temp. de 20 ± 2,5 °C

Système mis à l’essai et homologué par NSF International en regard des normes CSA B483.1 et NSF/ANSI 42 et 53 pour la réduction des substances indiquées dans la fiche technique du produit. C US

CARACTÉRISTIQUES DE FONCTIONNEMENT
· Capacité : 2 839 L (750 gallons) · Pression requise : de 0,7 à 8,6 bar (10 à 125 lb/po²), sans chocs · Température : de 2 à 38 °C (de 35 à 100 °F) · Débit : 1,9 L/min (0,5 gal./min)

NUMÉRO D’ÉTABLISSEMENT DE L’EPA 002623-IL-002

FRANÇAIS

EVERPURE H Série Système De Filtrage D’eau · 31

EVERPURE

FICHE TECHNIQUE DU PRODUIT
SYSTÈME D’EAU POTABLE H-300

Cartouche H-300 ­ numéros de pièce EV9270-71 et EV9270-72

NOTICE IMPORTANTE : Lisez la présente fiche technique du produit et comparez les capacités du système à vos besoins de traitement d’eau. Il est recommandé de faire analyser l’eau d’alimentation avant d’acheter un système de traitement d’eau afin de déterminer vos besoins réels de traitement d’eau.
CARACTÉRISTIQUES
· Améliore en finesse de l’eau traitée afin d’en faire une eau de première qualité que l’on peut boire et utiliser pour cuisiner.
· Réduit le goût et l’odeur de chlore. · Réduit la quantité d’impuretés, de rouille et d’autres particules
(p. ex., fer oxydé, manganèse et sulfures). · Certifié selon la norme NSF/ANSI 53 pour réduire les kystes comme
Cryptosporidium et Giardia par des moyens mécaniques. · Contrôle même des niveaux extrêmes de goûts et d’odeurs
désagréables courants, dont les goûts et odeurs de moisi, de terre et de poisson. · Réduit la quantité de plomb à un niveau moindre que le seuil d’intervention fédéral. · Réduit efficacement la quantité de composés organiques volatils (COV), y compris les trihalométhanes (THM).
· Séparation mécanique des particules d’à peine 0,5 micron.

CERTIFIÉ CONFORME AUX NORMES NSF/ANSI RELATIVES À LA RÉDUCTION SANITAIRE DES SUBSTANCES INDIQUÉES*
Ce système a été mis à l’essai en regard des normes NSF/ANSI 42 et 53 pour la réduction des substances indiquées ci-dessous. La concentration des substances indiquées dans l’eau entrant dans le système a été réduite à une concentration inférieure ou égale à la limite autorisée pour l’eau sortant du système, conformément aux normes NSF/ANSI 42 et 53.

Substance

Concentration infiltrante

Norme 42 ­ Effets esthétiques

Chlore

2,0 mg/L ± 10 %

Concentration maximale admissible du produit dans l’eau

Exigences de Réduction Réduction réduction minimale moyenne

50 %

86,8 %

Particules de classe 1, 0,5 à < 1 µm

Au moins 10 000 particules/ml

85 %

98,8 %

Norme 53 ­ Effets sur la santé

Kystes

Minimum de 50 000/L

99,95 %

99,99 %

99,99 %

Plomb (pH 6,5) 0,15 mg/L ± 10 %

0,010 mg/L

99,3 %

99,3 %

Plomb (pH 8,5) 0,15 mg/L ± 10 %

0,010 mg/L

98,7 %

99,3 %

Chloroforme

0,300 mg/L

0,015 mg/L

95,8 %

98,9 %

(substitut chimique des COV) *Essais à un débit de 0,5 gal./min, à une pression de 60 lb/po², à un pH de 7.5 ± 0.5 et à une temp. de 20 ± 2,5 °C
NUMÉRO D’ÉTABLISSEMENT DE L’EPA 002623-IL-002

Le système H-300 est mis à l’essai et homologué par NSF International en regard des normes CSA B483.1 et NSF/ANSI 42 et 53 pour la réduction des substances indiquées dans la fiche technique du produit.
C US

CARACTÉRISTIQUES DE FONCTIONNEMENT
· Capacité : 1 135 L (300 gallons) · Pression requise : de 0,7 à 8,6 bar (10 à 125 lb/po²), sans chocs · Température : de 2 à 38 °C (35 à 100 °F) · Débit : 1,9 L/min (0,5 gal./min)

Réductions indiquées dans la fiche technique pour des produits chimiques inclus par essais indirects

Substance
métachlore atrazine benzène carbofuran tétrachlorure de carbone chlorobenzène chloropicrine 2,4-D 1,2-dibromo-3-chloropropane (DBCP) o-dichlorobenzène p-dichlorobenzène 1,2-dichloroéthane 1,1-dichloroéthylène cis-1,2-dichloréthylène trans-1,2-dichloroéthylène 1,2-dichloropropane cis-1,3-dichloropropylène dinoseb endrine éthylbenzène dibromure d’éthylène (DBE)
haloacétonitriles (HAN) : bromochloroacétonitrile dibromoacétonitrile dichloroacétonitrile trichloroacétonitrile
halokétones (HK) : 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone
heptachlor heptachlor époxyde hexachlorobutadiène hexachlorocyclopentadiène lindane méthoxychlore pentachlorophénol simazine styrène 1,1,2,2-tétrachloroéthane tétrachloroéthylène toluène 2,4,5-TP (« silvex » aux É.-U.) acide tribromoacétique 1,2,4-trichlorobenzène 1,1,1-trichloroéthane 1,1,2-trichloroéthane trichloroéthylène trihalométhanes : chloroforme (substitut chimique) bromoforme bromodichlorométhane chlorodibromométhane
xylènes (totaux)

Concentration infiltrante (en mg/L)
0,050 0,100 0,081 0,190 0,078 0,077 0,015 0,110 0,052 0,080 0,040 0,088 0,083 0,170 0,086 0,080 0,079 0,170 0,053 0,088 0,044
0,022 0,024 0,0096 0,015
0,0072 0,0082 0,025 0,0107 0,044 0,060 0,055 0,050 0,096 0,120 0,150 0,081 0,081 0,078 0,270 0,042 0,160 0,084 0,150 0,180
0,310
0,070

Concentration maximale admissible du produit dans l’eau (en mg/L) 0,001 0,003 0,001 0,001 0,0018 0,001 0,0002 0,0017 0,00002 0,001 0,001 0,0048 0,001 0,0005 0,001 0,001 0,001 0,0002 0,00059 0,001 0,00002
0,0005 0,0006 0,0002 0,0003
0,0001 0,0003
0,00001 0,0002 0,001 0,000002 0,00001 0,0001 0,001 0,004 0,0005 0,001 0,001 0,001 0,0016 0,001 0,0005 0,0046 0,0005 0,001
0,015
0,001

NOTE : Un produit d’absorption utilisé ne sera pas regénéré afin d’être réutilisé. Si un produit d’absorption est affecté par le chlore, l’alimentation en eau devrait être traitée afin d’éliminer le chlore avant d’introduire le filtre.

32 · EVERPURE H Série Système De Filtrage D’eau

FRANÇAIS

2 and and

EVERPURE

FICHE TECHNIQUE DU PRODUIT FICHE TECHNIQUE DU PRODUIT
SYSTÈME D’EAU POTABLE H-1200 SYSTÈME D’EAU POTABLE H-1200

Cartouche H-1200 – numéros de pièce Ev9282-01 et EV9282-03

NOTICE IMPORTANTE: Lisez la présente fiche technique du produit et comparez les capacités du système à vos besoins de traitement d’eau. Il est recommandé de faire analyser l’eau d’alimentation avant d’acheter un système de traitement d’eau afin de déterminer vos besoins réels de traitement d’eau.

CARACTÉRISTIQUES DE FONCTIONNEMENT · Capacité: 3,785 L (1,000 gallons)

CARACTÉRISTIQUES · Amélior e en finesse de l’eau traitée afin d’en faire une eau
de première qualité que l’on peut boire et utiliser pour cuisiner. · Certifié sel on la norme NSF/ANSI 53 pour réduire les kystes comme Cryptosporidium et Giardia par das moyens mécaniques. · IAPMO R&T contre NSF/ANSI 53 pour la reduction de acide perfluorooctanoïque (PFOA) et du sulfonate de perfluorooctane (PFOS). · Système haute performance certifié pour réduire jusqu’à 97,5% de PFOA/PFOS, communément appelé “produits chimiques éternels”. · Réduit la quantité d’impuretés, de rouille et d’autres particlues (p.ex., fer oxydé, manganèse et sulfures) – sur la base d’essais effecturés par Everpure. · Contr ôle même des niveaux extrêmes de goûts et d’odeurs désagréables courants, dont les goûts et odeurs de moisi, de terre et de poisson. · Réduit la quantité de plomb à un niveau moindre que le seuil d’intervention fédéral de 15 parties par milliard (ppb). · Réduit efficacement la quantité de composés organiques volatils (COV), y compris les trihalométhanes (THM). · Réduit efficacement la quantité de méthyl-tert- butyléther (MTBE). · Séparation mécanique des particules d’à peine 0,5 micron.
CERTIFIÉ CONFORME AUX NORMES NSF/ANSI RELATIVES À LA RÉDUCTION SANITAIRE DES SUBSTANCES INDIQUÉES*

Ce système a été mis à essai en regard des normes NSF/ANSI 42

et 53 pour la réduction des substances indiquées ci-dessous. La

concentration des substances indiquées dans l’eau entrant dans le

système a été réduite à une concentration inférieure ou égale à la

limite autorisée pour l’eau sortant du système, conformément aux

normes NSF/ANSI 42 et 53.

Substance

Concentration infiltrante

Concentration maximale admissible du produit dans l’eau

Exigences de Réduction Réduction réduction minimale moyenne

Norme 42 ­ Effets esthétiques

Chlore

2,0 mg/L ± 10 %

50 %

86,8 %

Chloramines

3,0 mg/L ± 10 %

0,5 mg/L

98,3 %

Particules de classe 1, 0,5 à < 1 µm

Au moins 10 000 particules/ml

85 %

98,8 %

Norme 53 ­ Effets sur la santé

Kystes

Minimum de 50 000/L

99,95 %

99,99 %

99,99 %

Plomb (pH 6,5) 0,15 mg/L ± 10 %

0,010 mg/L

99,3 %

99,3 %

Plomb (pH 8,5)
Méthyl-tertbutyl éther
Chloroforme

0,15 mg/L ± 10 % 0,15 mg/L ± 20 %
0,300 mg/L

0,010 mg/L 0,005 mg/L 0,015 mg/L

98,7 % 73,5 % 99,8 %

99,3 % 90,2 % 99,8 %

(substitut chimique des COV) *Essais à un débit de 0,5 gal./min, à une pression de 60 lb/po², à un pH de 7.5 ± 0.5 et à une temp. de 20 ± 2,5 °C

C US

Le système H-1200 est mis à l’essai et homologué par NSF International en regard des normes CSA B483.1 et NSF/ANSI 42 et 53 pour la réduction des substances indiquées dans la fiche technique du produit.
EPA Est. No. 002623-IL-002
L’H-1200 est certifié par IAPMO R&T contre NSF/ANSI 53 pour la reduction de l’acide perfluorooctanoïque (PFOA) et du sulfonate de perfluorooctane (PFOS).

· Pression Requise: de 0,7 à 8,6 bar (10 à 125 ib/po2), san chocs · Température: de 2 à 38°C (35 à 100°F) · Débit: 1.9 L/min (0.5 gal./min)

RÉDUCTIONS INDIQUÉES DANS LA FICHE TECHNIQUE POUR DES PRODUITS CHIMIQUES INCLUS PAR ESSAIS INDIRECTS

Substance
métachlore atrazine benzène carbofuran tétrachlorure de carbone chlorobenzène chloropicrine 2,4-D 1,2-dibromo-3-chloropropane (DBCP) o-dichlorobenzène p-dichlorobenzène 1,2-dichloroéthane 1,1-dichloroéthylène cis-1,2-dichloréthylène trans-1,2-dichloroéthylène 1,2-dichloropropane cis-1,3-dichloropropylène dinoseb endrine éthylbenzène dibromure d’éthylène (DBE)
haloacétonitriles (HAN) : bromochloroacétonitrile dibromoacétonitrile dichloroacétonitrile trichloroacétonitrile
halokétones (HK) : 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone
heptachlor heptachlor époxyde hexachlorobutadiène hexachlorocyclopentadiène lindane méthoxychlore pentachlorophénol simazine styrène 1,1,2,2-tétrachloroéthane tétrachloroéthylène toluène 2,4,5-TP (« silvex » aux É.-U.) acide tribromoacétique 1,2,4-trichlorobenzène 1,1,1-trichloroéthane 1,1,2-trichloroéthane trichloroéthylène trihalométhanes : chloroforme (substitut chimique) bromoforme bromodichlorométhane chlorodibromométhane
xylènes (totaux)

Concentration infiltrante (en mg/L)
0,050 0,100 0,081 0,190 0,078 0,077 0,015 0,110 0,052 0,080 0,040 0,088 0,083 0,170 0,086 0,080 0,079 0,170 0,053 0,088 0,044
0,022 0,024 0,0096 0,015
0,0072 0,0082 0,080 0,0107 0,044 0,060 0,055 0,050 0,096 0,120 0,150 0,081 0,081 0,078 0,270 0,042 0,160 0,084 0,150 0,180
0,300
0,070

Concentration maximale admissible du produit dans l’eau (en mg/L) 0,001 0,003 0,001 0,001 0,0018 0,001 0,0002 0,0017 0,00002 0,001 0,001 0,0048 0,001 0,0005 0,001 0,001 0,001 0,0002 0,00059 0,001 0,00002
0,0005 0,0006 0,0002 0,0003
0,0001 0,0003
0,0004 0,0002 0,001 0,000002 0,00001 0,0001 0,001 0,004 0,0005 0,001 0,001 0,001 0,0016 0,001 0,0005 0,0046 0,0005 0,001
0,015
0,001

Ndl”aOêltTimrEee:rnUétnuattpiilTNaoricshonSiédeFde.u/Hn(ASiPt- iNeF1du2aSO’n0auIA0b5p)d3sriaesoonfvordcdrpreuapttriiitthetoiedêrnffit’leraruuedebtodisbltruioroyscaroéItipActiontétPinaeeoMnnoasOefefeiRsprnsaue&tdlrapfT’foéflaafunlsegioamcrartteeoiiénngo(spPeéctarnFtaréOlenrlSeoéc)i.hcachlfoilnorere, avant d’introduire le filtre.
The H-1200 is certified by IAPMO R&T against NSF/ANSI 53 for the reduction of perfluorooctanoic
acid (PFOA) and EpeVrEfluRoProUoRcEtaHneSséurlifeonSaytsetè(PmFeOSD)e. Filtrage D’eau · 33

FRANÇAIS

EVERPURE

FICHE TECHNIQUE DU PRODUIT
SYSTÈME D’EAU POTABLE H-300-HSD

Cartouche H-300-HSD ­ numéros de pièce EV9270-74 et EV9270-75

NOTICE IMPORTANTE : Lisez la présente fiche technique du produit et comparez les capacités du système à vos besoins de traitement d’eau. Il est recommandé de faire analyser l’eau d’alimentation avant d’acheter un système de traitement d’eau afin de déterminer vos besoins réels de traitement d’eau.
CARACTÉRISTIQUES
· Conçu pour une eau à densité en limon élevée par rapport au système H-300 standard.
· Améliore en finesse de l’eau traitée afin d’en faire une eau de première qualité que l’on peut boire et utiliser pour cuisiner.
· Réduit le goût et l’odeur de chlore. · Réduit la quantité d’impuretés, de rouille et d’autres particules (p. ex., fer
oxydé, manganèse et sulfures). · Certifié selon la norme NSF/ANSI 53 pour réduire les kystes comme
Cryptosporidium et Giardia par des moyens mécaniques. · Contrôle même des niveaux extrêmes de goûts et d’odeurs désagréables
courants, dont les goûts et odeurs de moisi, de terre et de poisson. · Réduit la quantité de plomb à un niveau moindre que le seuil d’intervention
fédéral de 15 parties par milliard (ppb). · Réduit efficacement la quantité de composés organiques volatils (COV). · Séparation mécanique des particules d’à peine 0,5 micron.

CERTIFIÉ CONFORME AUX NORMES NSF/ANSI RELATIVES À LA
RÉDUCTION SANITAIRE DES SUBSTANCES INDIQUÉES*
Ce système a été mis à l’essai en regard des normes NSF/ANSI 42 et 53 pour la réduction des substances indiquées ci-dessous. La concentration des substances indiquées dans l’eau entrant dans le système a été réduite à une concentration inférieure ou égale à la limite autorisée pour l’eau sortant du système, conformément aux normes NSF/ANSI 42 et 53.

Substance

Concentration infiltrante

Norme 42 ­ Effets esthétiques

Chlore

2,0 mg/L ± 10 %

Concentration maximale admissible du produit dans l’eau

Exigences de Réduction Réduction réduction minimale moyenne

50 %

86,8 %

Particules de classe 1, 0,5 à < 1 µm

Au moins 10 000 particules/ml

85 %

98,8 %

Norme 53 ­ Effets sur la santé

Kystes

Minimum de 50 000/L

99,95 %

99,99 %

99,99 %

Plomb (pH 6,5) 0,15 mg/L ± 10 %

0,010 mg/L

99,3 %

99,3 %

Plomb (pH 8,5) 0,15 mg/L ± 10 %

0,010 mg/L

98,7 %

99,3 %

Chloroforme

0,300 mg/L

0,015 mg/L

95,8 %

98,9 %

(substitut chimique des COV) *Essais à un débit de 0,5 gal./min, à une pression de 60 lb/po², à un pH de 7.5 ± 0.5 et à une temp. de 20 ± 2,5 °C

NUMÉRO D’ÉTABLISSEMENT DE L’EPA 002623-IL-002

Le système H-300-HSD est mis à l’essai et homologué par

NSF International en regard des normes CSA B483.1 et NSF/

ANSI 42 et 53 pour la réduction des substances indiquées

C

US

dans la fiche technique du produit.

NOTE : Un produit d’absorption utilisé ne sera pas regénéré afin d’être réutilisé. Si un produit d’absorption est affecté par le chlore, l’alimentation en eau devrait être traitée afin d’éliminer le chlore avant d’introduire le filtre.

CARACTÉRISTIQUES DE FONCTIONNEMENT
· Capacité : 1 135 L (300 gallons) · Pression requise : de 0,7 à 8,6 bar (10 à 125 lb/po²), sans chocs · Température : de 2 à 38 °C (35 à 100 °F) · Débit : 1,9 L/min (0,5 gal./min)

Réductions indiquées dans la fiche technique pour des produits chimiques inclus par essais indirects

Substance
métachlore atrazine benzène carbofuran tétrachlorure de carbone chlorobenzène chloropicrine 2,4-D 1,2-dibromo-3-chloropropane (DBCP) o-dichlorobenzène p-dichlorobenzène 1,2-dichloroéthane 1,1-dichloroéthylène cis-1,2-dichloréthylène trans-1,2-dichloroéthylène 1,2-dichloropropane cis-1,3-dichloropropylène dinoseb endrine éthylbenzène dibromure d’éthylène (DBE)
haloacétonitriles (HAN) : bromochloroacétonitrile dibromoacétonitrile dichloroacétonitrile trichloroacétonitrile
halokétones (HK) : 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone
heptachlor heptachlor époxyde hexachlorobutadiène hexachlorocyclopentadiène lindane méthoxychlore pentachlorophénol simazine styrène 1,1,2,2-tétrachloroéthane tétrachloroéthylène toluène 2,4,5-TP (« silvex » aux É.-U.) acide tribromoacétique 1,2,4-trichlorobenzène 1,1,1-trichloroéthane 1,1,2-trichloroéthane trichloroéthylène trihalométhanes : chloroforme (substitut chimique) bromoforme bromodichlorométhane chlorodibromométhane
xylènes (totaux)

Concentration infiltrante (en mg/L)
0,050 0,100 0,081 0,190 0,078 0,077 0,015 0,110 0,052 0,080 0,040 0,088 0,083 0,170 0,086 0,080 0,079 0,170 0,053 0,088 0,044
0,022 0,024 0,0096 0,015
0,0072 0,0082 0,080 0,0107 0,044 0,060 0,055 0,050 0,096 0,120 0,150 0,081 0,081 0,078 0,270 0,042 0,160 0,084 0,050 0,180
0,310
0,070

Concentration maximale admissible du produit dans l’eau (en mg/L) 0,001 0,003 0,001 0,01 0,0018 0,001 0,0002 0,0017 0,00002 0,001 0,001 0,0048 0,001 0,0005 0,001 0,001 0,001 0,0002 0,00059 0,001 0,00002
0,0005 0,0006 0,0002 0,0003
0,0001 0,0003
0,0004 0,0002 0,001 0,000002 0,00001 0,0001 0,001 0,004 0,0005 0,001 0,001 0,001 0,0016 0,001 0,0005 0,0046 0,0005 0,001
0,015
0,001

FRANÇAIS

34 · EVERPURE H Série Système De Filtrage D’eau

EVERPURE

FICHE TECHNIQUE DU PRODUIT
SYSTÈME D’EAU POTABLE H-300-NXT

Cartouche H-300-NXT ­ numéros de pièce EV927441 et EV927446

NOTICE IMPORTANTE : Lisez la présente fiche technique de produit Everpure et comparez les capacités du système à vos besoins de traitement d’eau.Il est recommandé de faire analyser l’eau d’alimentation avant d’acheter un système de traitement d’eau afin de déterminer vos besoins réels de traitement d’eau.
CARACTÉRISTIQUES
· Améliore en finesse de l’eau traitée afin d’en faire une eau de première qualité que l’on peut boire et utiliser pour cuisiner.
· Réduit le goût et l’odeur de chlore. · Réduit la quantité d’impuretés, de rouille et d’autres particules (p. ex., fer oxydé,
manganèse et sulfures) ­ sur la base d’essais effectués par Pentair. · Certifié selon la norme NSF/ANSI 53 pour réduire les kystes comme
Cryptosporidium et Giardia par des moyens mécaniques. · Contrôle même des niveaux extrêmes de goûts et d’odeurs désagréables courants,
dont les goûts et odeurs de moisi, de terre et de poisson. · Réduit la quantité de plomb. · Réduit efficacement la quantité de composés organiques volatils (COV). · Séparation mécanique des particules d’à peine 0,5 micron. · Certifié selon norme NSF/ANSI 401 relative à la réduction des contaminants
imprévus et des nouveaux composés indiqués dans la fiche technique du produit.

CERTIFIÉ CONFORME AUX NORMES NSF/ANSI RELATIVES À LA RÉDUCTION SANITAIRE DES SUBSTANCES INDIQUÉES
Ce système a été mis à l’essai en regard des normes NSF/ANSI 42, 53 et 401 pour la réduction des substances indiquées ci-dessous. La concentration des substances indiquées dans l’eau entrant dans le système a été réduite à une concentration inférieure ou égale à la limite autorisée pour l’eau sortant du système, conformément à aux normes NSF/ANSI 42, 53 et 401.

Substance

Concentration infiltrante

Norme 42 ­ Effets esthétiques

Chlore

2,0 mg/L ± 10 %

Concentration maximale admissible du produit dans l’eau

Exigences de réduction

50 %

Réduction minimale

Réduction moyenne
86,8 %

Particules de classe 1,

A moins

0,5 à < 1 µm

10 000 particules/ml

85 %

98,8 %

Norme 53 ­ Effets sur la santé

Kystes

Minimum de 50 000/L

Plomb (pH 6,5)

0,15 mg/L ± 10 %

0,010 mg/L

99,95 %

99,99 % 99,3 %

99,99 % > 99,3 %

Plomb (pH 8,5)

0,15 mg/L ± 10 %

0,010 mg/L

98,7 %

99,3 %

Chloroforme

0,300 mg/L

0,015 mg/L

95,8 %

98,9 %

(substitut chimique des COV) *Essais à un débit de 0,5 gal./min, à une pression de 60 lb/po², à un pH de 7.5 ± 0.5 et à une temp. de 20 ± 2,5 °C

Norme 401 ­ Nouveaux contaminants

Phénytoïne

200 ng/L ± 20 %

0,000030 mg/L

96,3 %

Ibuprofène

400 ng/L ± 20 %

0,000060 mg/L

95,8 %

Naxoprène

140 ng/L ± 20 %

0,000020 mg/L

96,8 %

Estrone (ou oestrone) 140 ng/L ± 20 %

0,000020 mg/L

97,2 %

Bisphénol A (BPA)

2 000 ng/L ± 20 %

0,000300 mg/L

99,2 %

Nonylphénol

1 400 ng/L ± 20 %

0,000200 mg/L

97,1 %

Les substances faisant l’objet d’une certification selon la norme NSF/ANSI 401 sont considérées comme étant des « contaminants imprévus » et des « nouveaux composés ». Les contaminants imprévus sont des contaminants détectés à l’état de traces dans les réseaux de distribution d’eau potable. Ces composés, bien qu’ils ne soient présents qu’à l’état de traces, peuvent nuire à la perception et à l’acceptation par le public de la qualité de l’eau potable.

NOTE : Un produit d’absorption utilisé ne sera pas régénéré afin d’être réutilisé. Si un produit d’absorption est affecté par le chlore, l’alimentation en eau devrait être traitée afin d’éliminer le chlore avant d’introduire le filtre.

CARACTÉRISTIQUES DE FONCTIONNEMENT
· Capacité : 1 136 L (300 gallons) · Pression requise : de 0,7 à 8,6 bars (10 à 125 lb/po²), sans chocs · Température : de 2 à 38 °C (35 à 100 °F) · Débit : 1,9 L/min (0,5 gal./min)

Réductions indiquées dans la fiche technique pour des produits chimiques inclus par essais indirects

Substance
métachlore atrazine benzène carbofuran tétrachlorure de carbone chlorobenzène chloropicrine 2,4-D 1,2-dibromo-3-chloropropane (DBCP) o-dichlorobenzène p-dichlorobenzène 1,2-dichloroéthane 1,1-dichloroéthylène cis-1,2-dichloréthylène trans-1,2-dichloroéthylène 1,2-dichloropropane cis-1,3-dichloropropylène dinoseb endrine éthylbenzène dibromure d’éthylène (DBE)
haloacétonitriles (HAN) : bromochloroacétonitrile dibromoacétonitrile dichloroacétonitrile trichloroacétonitrile
halokétones (HK) : 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone
heptachlor heptachlor époxyde hexachlorobutadiène hexachlorocyclopentadiène lindane méthoxychlore pentachlorophénol simazine styrène 1,1,2,2-tétrachloroéthane tétrachloroéthylène toluène 2,4,5-TP (« silvex » aux É.-U.) acide tribromoacétique 1,2,4-trichlorobenzène 1,1,1-trichloroéthane 1,1,2-trichloroéthane trichloroéthylène trihalométhanes : chloroforme (substitut chimique) bromoforme bromodichlorométhane chlorodibromométhane
xylènes (totaux)

Concentration infiltrante (en mg/L)
0,050 0,100 0,081 0,190 0,078 0,077 0,015 0,110 0,052 0,080 0,040 0,088 0,083 0,170 0,086 0,080 0,079 0,170 0,053 0,088 0,044
0,022 0,024 0,0096 0,015
0,0072 0,0082 0,080 0,0107 0,044 0,060 0,055 0,050 0,096 0,120 0,150 0,081 0,081 0,078 0,270 0,042 0,160 0,084 0,150 0,180
0,300
0,070

Concentration maximale admissible du produit dans l’eau (en mg/L) 0,001 0,003 0,001 0,001 0,0018 0,001 0,0002 0,0017 0,00002 0,001 0,001 0,0048 0,001 0,0005 0,001 0,001 0,001 0,0002 0,00059 0,001 0,00002
0,0005 0,0006 0,0002 0,0003
0,0001 0,0003
0,0004 0,0002 0,001 0,000002 0,00001 0,0001 0,001 0,004 0,0005 0,001 0,001 0,001 0,0016 0,001 0,0005 0,0046 0,0005 0,001
0,015
0,001

Le système H-300-NXT est mis à l’essai et homologué par NSF International en regard des normes CSA B483.1 et NSF/ ANSI 42, 53 et 401 pour la réduction des substances indiquées dans la fiche technique du produit. C US
NUMÉRO D’ÉTABLISSEMENT DE L’EPA 002623-IL-002

EVERPURE H Série Système De Filtrage D’eau · 35

FRANÇAIS

For Pentair Everpure Product Warranties visit: Pentair Everpure para las gasantías de los productos visite:
Pour Pentair Everpure garanties produit visitez le site:

pentair.com/assets/residential-filtration-warranty

13845 BISHOPS DR., SUITE 200, BROOKFIELD, WI 53005 U.S.A. EVERPURE.COM | CUSTOMER SERVICE: 800.279.9404 | tech-support@pentair.com | pentair.com ©2020 Pentair Residential Filtration, LLC. All rights reserved.
All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. Todas las marcas y logos de Pentair son propiedad de Pentair. Las marcas y logos registrados y no registrados de terceros son propiedad de sus respectivos propietarios. Toutes les marques et logos Pentair indiqués sont la propriété de Pentair. Toutes les autres marquescommerciales et déposées et tous les autres logos sont la propriété de leurs détenteurs respectifs.
EV307043 REV AJ OC22

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Pentair User Manuals

Related Manuals