U S Solid VEVOR Ultrasonic Cleaner 1.3L Professional Instruction Manual
- June 9, 2024
- U S SOLID
Table of Contents
U S Solid VEVOR Ultrasonic Cleaner 1.3L Professional
This manual shall be made available to all users of ultrasonic cleaners. To
ensure the best results and maximum durability of this U.S. SOLID LLC
(hereafter U.S. SOLID or The Company) product, read and follow all
instructions carefully. Failure to do so may lead to serious bodily injury and
catastrophic damage to the cleaner, supplies, or surrounding area. All safety
suggestions must be followed closely, and precautions must be taken to
guarantee this ultrasonic cleaner is only used by qualified personnel who have
understood this guide.
For questions or concerns, email:
service@ussolid.com.
Product Information
Ultrasonic Cleaner
The Ultrasonic Cleaner is a cleaning device that uses high-frequency sound
waves to generate cavitation in liquid, which attacks every surface and
invades all recesses and openings to remove stains or debris on objects. The
product comes in two variants: Digital Ultrasonic Cleaner and Mechanical
Ultrasonic Cleaner. The Digital Ultrasonic Cleaner has a digital display and
control panel, while the Mechanical Ultrasonic Cleaner has manual controls.
- Operating Principles: The transducers at the bottom of the ultrasonic cleaner generate intense high-frequency sound through the solution in the tank inducing cavitation in liquid.
- Getting Started: To ensure smooth and safe operations, please review the full manual for a better working experience. The company reserves the right to modify the specifications and procedures for this ultrasonic cleaner immediately and without notice. The warranty will only be in effect if all instructions in the manual are followed.
- Safety Instructions: Before using your Ultrasonic Cleaner, please read and understand the safety precautions thoroughly. Keep the unit away from children. Always make sure the machine is grounded, and unplug from the power source before filling or emptying the tank, and keep the control panel and the area around the cleaner clean and dry.
Product Usage Instructions
- Place the Ultrasonic Cleaner on a flat, stable surface that is close to an electrical outlet.
- Choose the appropriate variant of the Ultrasonic Cleaner: Digital or Mechanical.
- If using the Digital Ultrasonic Cleaner, plug it into an electrical outlet, and turn it on by pressing the power button. If using the Mechanical Ultrasonic Cleaner, fill it with water and plug it into an electrical outlet.
- Place the objects to be cleaned in the tank, ensuring they are fully submerged in the cleaning solution.
- Set the cleaning time and temperature using the digital display and control panel if using the Digital Ultrasonic Cleaner. If using the Mechanical Ultrasonic Cleaner, set the cleaning time and temperature manually.
- Start the cleaning cycle by pressing the start button if using the Digital Ultrasonic Cleaner. If using the Mechanical Ultrasonic Cleaner, turn on the machine.
- After the cleaning cycle is complete, turn off the machine and unplug it from the electrical outlet.
- Remove the objects from the tank and rinse them thoroughly with water.
- Clean the Ultrasonic Cleaner tank and wipe down the control panel and the area around the cleaner to ensure they are clean and dry.
Note: Always follow the instructions in the user manual for safe and effective use of the Ultrasonic Cleaner. Contact service@ussolid.com for any questions or concerns.
Operating Principles
Transducers at the bottom of the ultrasonic cleaner generate intense high- frequency sound through the solution in the tank inducing cavitation in liquid. As the cavitation bubbles collapse, high shearing energies work in all directions, attacking every surface and invading all recesses and openings to remove stains or debris on objects.
Getting Started
Thank you for purchasing the U.S. SOLID ultrasonic cleaner. To ensure smooth and safe operations, please review this full manual for a better working experience. Changes in technology happen often and rapidly, which is why our team at U.S. SOLID reserves the right to modify the specifications and procedures for this ultrasonic cleaner immediately and without notice. The Company will not assume responsibility for equipment damage or malfunction due to improper operation, incorrect repairs, or use of unauthorized parts.
You have 30 days from the date of delivery to return this product. A 15% restocking fee will be applied if the returned item has been opened. We provide a 12-month warranty from the date of the sale, and we are responsible for any replacement parts caused by quality issues within the warranty window. If you want to return a defective item, please contact our customer service team to receive a free prepaid shipping label for your return. To expedite the warranty process, please describe the issue and include the following information: purchase date, order number, name of the original purchasing entity, delivery address, and serial number. After the 12-month warranty period, we offer to replace parts at the current retail cost, but complete product returns will not be accepted.
The warranty will only be in effect if all instructions in the manual are followed. The warranty does not cover damage caused by force majeure (e.g., natural disasters such as hurricanes, floods, or earthquakes). This manual includes basic safety precautions, installation, operation, and maintenance instructions.
Safety Instructions
Before using your Ultrasonic Cleaner, please read and understand these safety precautions thoroughly. Failure to follow them may result in serious personal injury or property damage. Keep the unit away from children!
To avoid electrical shock:
- Always make sure the machine is grounded. Do not remove the grounding prong on the line cord plug.
- Do unplug from the power source before filling or emptying the tank.
- Do keep the control panel and the area around the cleaner clean and dry—wipe up the solution that spills over the tank brim. Water and high voltage can cause electrical shock.
- Do NOT disassemble your machine—high voltage inside the cleaner is dangerous.
- Never immerse the cleaner or power cord in water or other liquid. DO NOT touch the unit if the machine has fallen into the water during operation. Remove the power plug from the socket first.
- Do NOT handle electric appliances with wet hands.
To prevent personal and/or property damage:
- Do use water-based solutions.
- Do not use alcohol, gasoline, flammable solutions, or chlorine bleach. Doing so could cause a fire or explosion and will void your warranty. Use only water-based solutions.
- Do NOT touch the stainless-steel tank or cleaning solution—they may be hot.
- Do NOT allow the fluid temperature to exceed 80ºC (176ºF).
- Do NOT place your fingers or hands into the tank while the cleaner operates. Doing so may cause discomfort and possible skin irritation. Avoid contact with solutions and provide adequate ventilation.
- Please cover the tank with the lid to reduce noise and take care to avoid the hot water and steam to prevent burning your skin while removing the lid.
- Do NOT use the machine where the following conditions exist:
- A place where there are extreme temperature changes,
A place where there is high humidity that causes condensation,
A place where there is strong vibration that could cause the cleaner to fall,
A place where there are corrosive gases or dust,
A place where water, oil, or chemicals may splatter, or
A place where there are explosive and flammable gases.
- A place where there are extreme temperature changes,
To prevent damage to the cleaner:
- Do NOT cover vents on the cover. Keep the area around the machine clean and free of debris. Place the ultrasonic cleaner on a stable and level surface. DO NOT place the device on a soft surface where the vents could be blocked.
- Do NOT ever use mineral acids as these could damage the tank.
- Do NOT run the machine CONTINUOUSLY for longer than 30 min. Running the cleaner for an extended time will cause temperature increases and damage the tank and transducers.
- Do keep the lid on during and after use which will prevent splashing and reduce evaporation of the fluid.
- Only use original parts from the manufacturer to ensure your safety and the best product performance.
- Ensure the power switch is placed in the O position (OFF) before starting.
- Do not operate when the tank is empty, or damage to the ultrasonic generator will occur. The liquid volume must be over the 2/3 line if heating is functioning.
- Do not relocate the machine while fluid is in the tank to prevent overflowing.
- The maximum running time for a single cycle is 30 minutes. Always allow a rest time of 20 minutes between cleaning cycles.
- DO NOT drop any item into the tank, as this may cause damage to the transducer. Always place items gently into the basket. Never set parts directly on the tank.
- Upon completion of the cleaning process, unplug the machine. Always clean the tank with a cloth after use.
Specification
Digital Ultrasonic Cleaner
Model | USS-UC01 | USS-UC02 | USS-UC03 |
---|---|---|---|
Frequency | 40 kHz | 40 kHz | 40 kHz |
Transducer | 1 | 2 | 3 |
Capacity | 2 L (0.5 gal) | 3 L (0.8 gal) | 6.5 L (1.7 gal) |
Tank size | 1513.510 cm |
(5.95.33.9″)
| 23.513.510 cm
(9.35.33.9″)
| 301515 cm
(11.85.95.9″)
Unit Size| 17.51621 cm
(6.96.38.3″)
| 2616.522.5 cm
(10.46.58.7″)
| 37.51827.5 cm
(12.87.111″)
Unit Weight| 2.22 kg (4.89 lb)| 3.31 kg (7.30 lb)| 5.5 kg (12.13 lb)
Heating Power| 100 W| 100 W| 200 W
Ultrasonic Power| 80 W| 120 W| 180 W
Working Time| 0-30 min| 0-30 min| 0-30 min
Max. Heating
Temperature
| 80°C (176°F)| 80°C (176°F)| 80°C (176°F)
Package Dimension| 25.52426.5cm
(109.510.4″)
| 3424.531 cm
(13.49.712.2″)
| 4125.535.5 cm
(16.11014″)
Package Weight| 2.62 kg (5.68 lb)| 3.83 kg (8.44 lb)| 6.2 kg (13.67 lb)
Drainage| N/A| N/A| √
Model| USS-UC04| USS-UC05| USS-UC06
---|---|---|---
Frequency| 40 kHz| 40 kHz| 40 kHz
Transducer| 4| 6| 10
Capacity| 10 L (2.6 gal)| 15 L (4 gal)| 30 L (5.3 gal)
Tank size| 29.823.515 cm
(11.79.35.9″)
| 32.529.815 cm
(12.811.75.9″)
| 5029.820 cm
(19.711.77.9″)
Unit Size| 37.526.527.5 cm
(14.810.410.8″)
| 40.332.527.3cm
(15.912.810.7″)
| 57.532.333 cm
(22.612.713″)
Unit Weight| 7.4 kg (16.31 lbs.)| 8.8 kg (19.40 lbs.)| 13.4 kg (29.54 lbs.)
Heating Power| 200 W| 300 W| 500 W
Ultrasonic Power| 240 W| 360 W| 600 W
Working Time| 0-30 min| 0-30 min| 0-30 min
Max. Heating
Temperature
| 80°C (176°F)| 80°C (176°F)| 80°C (176°F)
Package Dimension| 43.53635 cm
(17.114.213.8″)
| 464134 cm
(18.116.113.4″)
| 684538.5 cm
(26.817.815.2″)
Package Weight| 8.3 kg (18.30 lbs.)| 9.6 kg (21.16 lbs.)| 15 kg (44.07 lbs.)
Drainage| √| √| √
Mechanical Ultrasonic Cleaner
Model | USS-UC11 | USS-UC12 | USS-UC13 |
---|---|---|---|
Frequency | 40 kHz | 40 kHz | 40 kHz |
Transducer | 1 | 2 | 3 |
Capacity | 2 L (0.5 gal) | 3 L (0.8 gal) | 6.5 L (1.7 gal) |
Tank size | 1513.510 cm |
(5.95.33.9″)
| 23.513.510 cm
(9.35.33.9″)
| 301515 cm
(11.85.95.9″)
Unit Size| 17.51621 cm
(6.96.38.3″)
| 2616.522.5 cm
(10.46.58.7″)
| 37.52027.5cm
(14.77.810.8″)
Unit Weight| 2.4 kg (5.29 lb)| 3.6 kg (7.94 lb)| 5.5 kg (12.13 lb)
Heating Power| 100 W| 100 W| 200 W
Ultrasonic Power| 80 W| 120 W| 180 W
Working Time| 0-30 min| 0-30 min| 0-30 min
Max. Heating
Temperature
| 80°C (176°F)| 80°C (176°F)| 80°C (176°F)
Package Dimension| 262426.5cm
(10.29.510.4″)
| 3424.531 cm
(13.49.712.2″)
| 4125.535.5 cm
(16.11014″)
Package Weight| 2.62 kg (5.68 lb)| 4.3 kg (9.48 lb)| 6.2 kg (13.67 lb)
Drainage| N/A| N/A| √
Model| USS-UC14| USS-UC15| USS-UC16
---|---|---|---
Frequency| 40 kHz| 40 kHz| 40 kHz
Transducer| 4| 6| 10
Capacity| 10 L (2.6 gal)| 15 L (4 gal)| 30 L (5.3 gal)
Tank size| 29.823.515 cm
(11.79.35.9″)
| 32.529.815 cm
(12.811.75.9″)
| 5029.820 cm
(19.711.77.9″)
Unit Size| 37.526.527.5 cm
(14.810.410.8″)
| 40.332.527.3cm
(15.912.810.7″)
| 57.532.333 cm
(22.612.713″)
Unit Weight| 7.4 kg (16.31 lbs.)| 8.8 kg (19.40 lbs.)| 13.4 kg (29.54 lbs.)
Heating Power| 200 W| 300 W| 500 W
Ultrasonic Power| 240 W| 360 W| 600 W
Working Time| 0-30 min| 0-30 min| 0-30 min
Max. Heating
Temperature
| 80°C (176°F)| 80°C (176°F)| 80°C (176°F)
Package Dimension| 43.53635 cm
(17.114.213.8″)
| 464134 cm
(18.116.113.4″)
| 684538.5 cm
(26.817.815.2″)
Package Weight| 8.3 kg (18.30 lbs.)| 9.6 kg (21.16 lbs.)| 15 kg (44.07 lbs.)
Drainage| √| √| √
Product Structure
Digital Ultrasonic Cleaner
USS-UC01, USS-UC02
USS-UC03, USS-UC04, USS-UC05, USS-UC06
Mechanical Ultrasonic Cleaner
Operation
Digital Ultrasonic Cleaner
Preparation
- Place ultrasonic cleaner on a flat, stable surface.
- Put items to be cleaned inside the basket and gently place the basket inside the tank. DO NOT PLACE THE ITEMS directly on the bottom of the tank.
- Add solution according to the object to be cleaned. Ensure that the volume of the solution is over 2/3 when the heating is on. It is forbidden to heat if you use flammable liquids because prolonged vibration will increase fluid temperature, which may lead to a fire.
- Plug the cleaner into a grounded outlet. Click the power switch at the back. “O” is off, and “-” is on.
Set working time and temperature
- Press TIME+ to increase working time and TIME to shorten the working process by 1 minute. Press ON/OFF, then the ultrasonic indicator turns red, and the machine starts working. Meanwhile, the timer begins to count down, and the cleaner will automatically stop working when the time reaches 00:00.
- Once the cleaner is turned on, the indicator shows room temperature; press TEMP+/TEMP- to increase/decrease temperature. The temperature indicator shows the setting and actual temperature when the heater is working, and the heater indicator goes off when the actual temperature reaches the set temperature.
Unplug the machine
Press ON/OFF to stop working, unplug the machine, empty the tank, and clean
the unit with cloth for subsequent use.
Mechanical Ultrasonic Cleaner
Preparation
- Place ultrasonic cleaner on a flat, stable surface.
- Put items to be cleaned inside the basket and gently place the basket inside the tank. DO NOT PLACE THE ITEMS directly on the bottom of the tank.
- Add solution according to the object to be cleaned. Ensure that the volume of thxe solution is over 2/3 when the heating is on. It is forbidden to heat if you use flammable liquids because prolonged vibration will increase fluid temperature, which may lead to a fire.
- Plug the cleaner into a grounded outlet. Click the power switch at the back. “O” is off, and “-” is on.
Set working time and temperature
- Rotate the right knob clockwise to increase working time and rotate it anticlockwise to shorten the working process by 1 minute. Meanwhile the ultrasonic indicator turns red, and the machine starts working. The cleaner will automatically stop working when the knob reaches OFF.
- Heating is an optional function of the machine. Rotate the left knob clockwise/anticlockwise to increase/decrease the setting temperature. The heater indicator goes off when the actual temperature reaches the set temperature.
Unplug the machine
Press ON/OFF to stop working, unplug the machine, empty the tank, and clean
the unit with cloth for subsequent use.
Applications
The ultrasonic cleaner is widely used in many areas or industries. The list below are the most common industries using an ultrasonic cleaner to clean objects:
- Semiconductors
- Electrical and electronic machines
- Precision machines
- Optical devices
- Hardware and machinery parts
- Medical instruments
- Electroplating
- Car parts
- Chemical fibers
Troubleshooting
Problems: No ultrasonic
- Possible Causes
- A. Power supply is not connected.
- B. Fuse is broken.
- C. Cable runs into a short circuit.
- D. Transducer short circuit.
- E. PCB board is broken.
- F. Other reasons.
- Solutions
- A. Connect the machine to a power supply.
- B. Change the fuse.
- C. Connect the fitted cable or replace a new one.
- D.E.F. Contact us for help.
Problem: Time control failure
- Possible Causes
- A. Timer fails to work.
- B. other reasons
- Solutions
- A. Replace the timer or digital control panel.
- B. Contact us for help.
Problem: No heating
- Possible Causes
- A. Circuit of heater doesn’t connect well.
- B. Fuse burns out.
- C. Heating pad burns out.
- D. Digital display board is out of control.
- E. Other reasons.
- Solutions
- A. Reconnect the plug.
- B. Change the fuse.
- C.D.E. Contact us for help.
Problem: Temperature control failure
- Possible Causes:
- A. Thermostat is loosened.
- B. Thermostat tube is broken.
- C. Digital display is out of control.
- D. Other reasons.
- Solutions
- A. Tighten the thermostat header.
- B. Replace thermostat.
- C. Check the broken part and change it.
- D. Contact us for help.
Problem: Poor cleaning effect.
- Possible Causes
- A. Liquid level is too high or too low.
- B. Temperature is too high or too low.
- C. Cleaning solution is not suitable for the object.
- D. Other reasons.
- Solutions
- A. Adjust the liquid volume.
- B. Adjust temperature to optimum one.
- C. Stop the working prprocess and unplug the machine. Replace the solution.
- D. Contact us for help.
Problem: Electric leakage
- Possible Causes The machine is not connected to a grounded socket.
- Solutions Make sure the machine is grounded.
Other problems: Please consult our customer service.
For questions or concerns, email: service@ussolid.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>