PENTAIR SKV40 Hydromatic Submersible Sewage Ejector Pump Instruction Manual
- June 10, 2024
- Pentair
Table of Contents
Hydromatic Submersible Sewage Ejector Pump
Instruction Manual
SAFETY INFORMATION
Carefully read and follow all safety instructions in this manual or on pump.
This is the safety alert symbol. When you see this symbol on your pump or in
this manual, look for one of the following signal words and be alert to the
potential for personal injury!
warns about hazards that will cause serious personal injury, death or major
property damage if ignored.
warns about hazards that can cause serious personal injury, death or major
property damage if ignored.
warns about hazards that will or can cause minor personal injury or property
damage if ignored. The word NOTICE indicates special instructions which are
important but not related to hazards.
-
Read these rules and instructions carefully. Failure to follow them could cause serious bodily injury and/or property damage.
-
Check your local codes before installing. You must comply with their rules.
-
Vent sewage or septic tank according to local codes.
-
Do not install pump in any location classified as hazardous by National Electrical Code, ANSI/NFPA 80-1984 or the Canadian Electrical Code.
Hazardous voltage. Can shock, burn, or kill. During operation the pump is in water.To avoid fatal shocks, proceed as follows if pump needs servicing: -
Do not smoke or use devices that can generate sparks in aseptic (gaseous) environment.
5A. Disconnect power to outlet box before unplugging pump.
5B. Take extreme care when changing fuses. Do not stand in water or put your finger in the fuse socket. 5C. Do not modify the cord and plug. When using the cordand plug, plug into a grounded outlet only. When wiring to a system control, connect the pump ground lead to the system ground. -
Be sure that construction and access to septic sumps conform with all OSHA requirements.
-
Do not run the pump dry. Dry running can overheat the pump, (causing burns to anyone handling it) and will void the warranty.
-
The pump normally runs hot. To avoid burns when servicing pump, allow it to cool for 20 minutes after shutdown before handling it.
-
The pump is permanently lubricated. No oiling or greasing is required in normal operation. for overhaul, see instructions under “Service”.
California Proposition 65 Warning
This product and related accessories contain chemicals known to the State of
California to cause cancer, birth defects or other reproductive harm.
DESCRIPTION
This submersible sewage ejector pump is designed for residential wastewater
removal, sewage applications, sump drainage, dewatering and flood control.
Units have built in thermal overload protection with automatic reset. The
mechanical seal and bearings on the motor shaft are permanently lubricated.
Stainless steel hardware and a heavy duty lift out handle allow for easy
disassembly after extended use. NOTICE: This unit is not designed for
applications involving salt water or brine! Use with salt water or brine will
void warranty.
SPECIFICATIONS
Power supply required ……………………..See “Motor and Cord Specifications” chart
below.
Motor duty ……………………………………………………. Intermittent.
Maximum Liquid Temperature …………………….. 120°F (49°C).
Discharge Adapter …………………………………………….. 2″ NPT.
Switch Specifications
Type | Switch Setting in Inches (mm) |
---|---|
On | Off |
Wide Angle Float | 12-1/2″(318) |
Vertical | 8-15/16(227) |
Diaphragm | 8-7/8(225) |
MOTOR & CORD SPECIFICATIONS
Model Number| Motor HP| Voltage| Motor Full Load Amps| Individual Branch
Circuit
Required (Amps)| Cord Length
in ft. (m)| Discharge Adapter Size
---|---|---|---|---|---|---
SKV40M1| 4/10| 115| 13.| 20| 10 (3.0)| 2″
SKV40M2| 4/10| 230| 6.| 15| 10 (3.0)| 2″
PERFORMANCE
GPM AT TOTAL FEET
Model| 10| 15| No flow at height shown below
CAPACITY GALLONS/MINUTE
SKV40M1| 78| 40| 19
SKV40A1| 78| 40| 19
SKV40M2| 78| 40| 19
SKV40A2| 78| 40| 19
INSTALLATION
Hazardous voltage. Can shock, burn or kill.
Do not lift pump by the power cord. See “Cord Lift Warning” below.
NOTICE: Install the pump on a hard, level surface (cement, asphalt, etc.).
Never place the pump directly on earth, clay or gravel surfaces. Install the
pump in a sump basin with a minimum diameter of 18″ (46cm).
Piping
Piping must not be smaller than pump discharge. When installed in a sewage
system, the pipe must be capable of handling semi-solids of at least 2″ (51mm)
India meter.
When installed in an effluent system, the pipe must be capable of handling
semi-solids of at least 3/4″ (19mm) in diameter. The rate of flow in the
discharge pipe must keep any solids present in suspension in the fluid. To
meet minimum flow requirements (2 feet per second in the discharge line), size
the pipe as follows:
A Pipe Size Of: | Will Handle a Flow Rate Of: |
---|---|
1-1/2″ (38mm) | 12 GPM |
2″ (51mm) | 21 GPM |
2-1/2″(64mm) | 30 GPM |
3″(76mm) | 48 GPM |
In a sewage system use a 2″ (51mm) check valve in pump discharge to prevent
backflow of liquid into sump basin. The check valve should be installed 12–18″
(317–457mm) above the pump discharge and be a free flow valve that will easily
pass solids. Be sure check valve installation complies with local codes.
In an effluent system use a 1-1/2″ (28mm) check valve in pump discharge to
prevent backflow of liquid into sump basin. NOTICE: For best performance of
check valve when handling solids, do not install it with the discharge more
than 45° above the horizontal. Do not install the check valve in a vertical
position as solids may settle in the valve and prevent it from opening on
startup.
Drill a 3/16″ (5mm) hole in the discharge pipe about 1–2″ (25-51mm) above the
pump discharge connection (but below check valve) to prevent relocking the
pump. Be sure that the wide-angle float switch hangs freely. It should not be
able to come in contact with the sides or bottom of the sump pit.
Make sure the sump pit is free of any debris that could obstruct the intake
volute or switch. Use plumbing materials that are approved by local building
codes when connecting pipes between pump and sewer outlet.
NOTICE: For critical indoor installations where additional high water
protection is desired, install a “Q-Alert” audible alarm system in the sump
pit. For outdoor installations, confer with your Hydromantic distributor.
Connect the power cord to a 3-prong grounded AC receptacle.
Hazardous voltage. Can shock, burn or kill. DO NOT remove the grounding
pin from the power cord. Avoid using extension cords or 2-prong adapter plugs.
Insert the piggyback plug that comes from the wide-angle float switch directly
into the power receptacle. Insert the pump power cord directly into the back
of the piggyback plug.
Test the pump installation by filling the sump basin with enough water to
activate the pump and repeat this cycle until satisfied with pump operation.
Electrical
Hazardous voltage. Can shock, burn, or kill. When installing, operating, or
servicing this pump, follow the safety instructions listed below.
- DO NOT splice the electrical power cord.
- DO NOT allow the plug on the end of the electrical cord to be submerged.
- DO NOT use extension cords. They are a fire hazard and can reduce voltage sufficiently to prevent pumping and/or damage motor.
- DO NOT handle or service the pump while it is connected to the power supply.
- DO NOT remove the grounding prong from the plug or modify the plug. To protect against electrical shock, the power cord is a three-wire conductor and includes a 3-prong grounded plug. Plug the pump into a 3-wire, grounded, grounding-type receptacle. Connect the pump according to the NEC or CEC and local codes.
For automatic operation, plug the pump into the piggy-back switch plug. Plug the piggy-back switch plug into the outlet. For continuous running, plug the pump directly into the outlet (that is, bypass the piggyback switch plug).
WARNING
Risk of electrical shock. Can burn or kill. Do not lift pump by power cord.
CORD LIFT WARNING
- Attempting to lift or support pump by power cord can damage cord and cord connections.
- Cord may pull apart, exposing bare wires with possibility of fire or electrical shock.
- Lifting or supporting pump by power cord will void warranty.
- Use lifting ring or handle on top of pump for all lifting/lowering of pump. Disconnect power to pump before doing any work on pump or attempting to remove pump from sump.
Connect pump to its own individual branch circuit with no other outlets or
equipment in the circuit. Size fuses or circuit breakers according to the
“Motor, Switch and Cord Specifications” chart, Page 1.
Risk of electrical shock and fire. Can burn, kill or cause property damage. Be
sure that power supply information (Voltage/ Hertz/Phase) on pump motor
nameplate matches incoming power supply exactly. Install pump according to all
electrical codes that apply.
OPERATION
Risk of fire or explosion. Can cause severe personal injury, property damage
or death. Do not use in explosive atmospheres. Pump water only with this
pump.
NOTICE: Do not allow the pump to run in a dry sump. It will void the
warranty and may damage the pump. An automatic overload protector in the motor
will protect the motor from burning out due to overheating/overloading. When
the motor cools down, the overload protector will automatically reset and
start the motor. If the overload trips frequently, check for the cause. It
could be a stuck impeller, wrong/low voltage, or an electrical failure in the
motor. If an electrical failure in the motor is suspected, have it serviced by
a competent repairman.
The pump is permanently lubricated. No oiling or greasing is required. Cycle
the pump at least once every month to be sure that the system is working
satisfactorily.
NOTE: Any of the following will void the pump warranty:
- Submerging, plugging, damaging or taping shut a vented cord.
- Pumping materials other than those the pump was designed to pump or continuously pumping water hotter than 120°F (49°C).
- Cutting or splicing a power cord or switch cord.
- Anyone other than an authorized Hydromantic service technician dismantling the pump.
- Removing the cord tag from the cord.
SERVICE
General
Hazardous voltage and risk of cord damage. Can shock, burn, or kill. Before
removing the pump from the basin for service, always disconnect electrical
power to the pump and the control switch. Do not lift the pump by the power
cord. See the “Cord Lift Warning”, Page 2.
Disinfect the Pump
Place the pump in an area where it can be cleaned thoroughly. Remove all scale
and deposits on the pump. Submerge the complete pump in a disinfectant
solution (Clorox or chlorine bleach) for at least one hour before
disassembling the pump.
The pump motor housing contains a special lubricating oil which should be kept
clean and free of water at all times. NOTICE: Whenever the motor housing is
being removed for service, remove oil and replace it with new oil at
reassembly.Use only oil listed in parts list in this manual. When filling with
new oil, DO NOT overfill. Fill with new oil so that the surface of the oil is
1/4″ above the motor windings.
Check Motor Windings
-
Use a quality volt-ohm-meter (VOM) when performing these inspections.
-
Set the meter to Rx1.
-
Touch both flat prongs of the power cord to the leads of the VOM and observe the readings:
a. 230 Volt System – 0.8 to 1.1 ohms
b. 115 Volt System – 1.6 to 1.8 ohms
Check Pump Ground -
Set the meter to Rx100.
-
Touch one lead to the grounding pin and the other lead to one flat prong of the plug. Repeat for the other prong.
-
Reading should be infinity for both prongs.
a. If the reading is anything other than infinity, the stator must be removed, dried and rechecked.
b. A reading of “0” indicates a dead short. Replace the stator.
Removing the Pump Housing
(See “Disinfect the Pump”)
-
Remove the oil fill plug from the housing and drain the pump oil into a clean bucket. A milky appearance indicates that water has leaked into the oil. Replace O-rings and/or seals.
-
Remove the three caps crews from the upper motor housing and remove housing.
NOTICE: Use caution not to damage the two motor leads that are attached inside the housing. -
Remove the two motor leads from the cord plug and set aside.
Removing the Impeller
-
Remove the three caps crews and separate the volute from the seal plate.
NOTICE: Loctite #277 is used to install the impeller during assembly. Break this seal to remove the impeller. Use a plastic or rubber mallet to tap on pump components while holding the shaft with a screwdriver. -
Tap the impeller in a counterclockwise direction until it comes free of the shaft.
-
Remove the three screws and remove the motor housing from the seal plate.
Replacing Ceramic Seal
-
Insert a screwdriver under the rotating ceramic seal and remove it.
-
Remove the two bolts holding the stator to the seal plate.
-
Tap the shaft and rotor assembly out.
NOTICE: The lower ball bearing will come out with the shaft and rotor assembly. -
Tap out the stationary half of the seal from the top of the seal plate and wipe clean.
-
Coat the replacement seal with a thin coat of dielectric oil and push the seal into the seal housing with a plastic dowel, carbon face out. Do not damage, scratch or mar the carbon face of the seal.
Rotor Shaft and Bearing Replacement and Assembly
NOTICE: The replacement rotor must be of the same manufacture as the
existing rotor.
-
Push the new rotor shaft and bearing assembly into the seal plate.
-
Fasten the stator to the seal plate with the two long caps crews.
-
Tighten the screws evenly and firmly in order to prevent any misalignment of the rotor and stator.
-
Coat the new ceramic rotating seal with a thin coat of dielectric oil and press into place on the rotor shaft with the rubber ring facing the impeller.
NOTICE: The ceramic seal must be kept clean. Any dirt will cause the seal to fail. -
Make sure that the shaft is clean.
-
Hold the shaft with a screwdriver and start the impeller on the shaft one or two turns.
-
Add a drop of Loctite #277 to the threads and screw the impeller on the rest of the way hand tight. The impeller will force the ceramic seal into position.
NOTICE: Excessive Loctite on the seal or bearing will cause the shaft to seize. -
Remove the old square-cut O-ring and install the new O-ring. Avoid rolling the O-ring into position; lubricate and stretch the new O-ring to fit.
-
Install the seal plate on the volute with the three caps crews.
-
Fasten the motor leads inside the motor housing and tuck the wires up into the housing to prevent contact with the rotor.
-
Assemble the motor housing to the seal plate with three caps crews.
-
Check for seal leaks by pressurizing the pump to 7 to 9 PSI. If air bubbles continue, recheck seals.
-
Fill the motor housing with high-grade transformer oil.
-
Adjust oil level to at least 1/4″ (6mm) above the motor windings top plate or to the top of the stator.
NOTICE: Do not fill the motor housing completely. Allow air space for expansion. -
Replace the oil fill plug.
-
Recheck winding resistance before applying power.
-
Plug the power cord into a grounded outlet and check the pump operation. Motor should run smoothly and be free of vibration.
Pump Disassembly
EXPLODED VIEW
REPAIR PARTS LIST
Key No. | Part Description | Qty | Part Number |
---|---|---|---|
1 | Cord 115V 10′ | 1 | 14623-010-1 |
1 | Cord 115V 20′ | 1 | 14623-020-1 |
1 | Cord 230V 20′ | 1 | 14623-220-1 |
• | Cord Seal Ring | 1 | 00139-014-1 |
2 | Motor Housing | 1 | 08507-013-5 |
3 | Square-Cut O-Ring | 1 | 00149-001-1 |
4 | Motor | 1 | * |
5 | Seal Plate | 1 | 14599-000-2 |
6A | Seal Half, Stationary | 1 | 05484-001-1 |
6B | Seal Half, Rotating | 1 | 05484-003-1 |
7 | Impeller | 1 | 08498-003-1 |
8 | Volute | 1 | 21612D000 |
9 | Diaphragm Switch, 115V 10′ | 1 | 51752-403-7 |
9 | Diaphragm Switch, 115V 20′ | 1 | 51752-404-7 |
• | Wide Angle Float Switch, 115V 10′ | 1 | 13967-010-7 |
• | Wide Angle Float Switch, 115V 20′ | 1 | 13967-020-7 |
• | Wide Angle Float Switch, 230V 20′ | 1 | 13967-025-7 |
• | Vertical Switch, 115V 10′ | 1 | 14105-000-5 |
• | Vertical Switch, 230V 10′ | 1 | 14105-001-5 |
10 | Handle | 1 | 08522-006-1 |
- If motor fails, replace entire pump.
• Not Illustrate
TROUBLES-REMEDIES
Sudden Starts. If the power is on to the pump when thermal overload resets, the pump may start without warning. If you are working on the pump, you may get an electrical shock or the impeller may catch fingers or tools. Disconnect the power before servicing the pump.
A. Pump fails to operate:| 1. Check to be sure that power cord is securely
plugged into outlet or securely wired
into controller or switch box.
2. Check to be sure you have electrical power. Be sure that the piggyback
plugs airtight.
3. Check that liquid fluid level is high enough to activate switch or
controller.
4. Check to be sure that 1/8″ (3 mm) vent hole in discharge pipe is not
plugged.
5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.
6. Disconnect the pump from the power source for a minimum of 30 minutes to
allow
the motor to cool and to protect yourself from sudden starts. See Warning
above.
Check for the cause of overheating. Pump is running dry because the float
switch
is caught up on something. Inlet pipe is plugged. Outlet pipe is plugged.
7. Motor windings may be open. Take unit to authorized service center.
---|---
B. Pump runs, but fails to empty sump:| 1. Be sure all valves in discharge
pipe are fully open.
2. Clean out discharge pipe and check valve.
3. Check for blockage in pump inlet or impeller.
4. Pump not sized properly. A higher capacity pump may be required.
C. Pump will not shut off:| 1. Check switch for proper operation and
location. See installation instructions for switch.
2. If pump is completely inoperative or continues to malfunction, consult
your local serviceman.
D. Pump run but fails to deliver water:| 1. Check valve may be installed
backwards. Be sure that the arrow on valve points in the direction of flow.
2. Pump may be airlocked. Check vent hole in impeller housing.
E. Pump fuse blows or trips circuit breaker: Motor runs for short time and
stops:| 1. Check fuse size.
2. Intake opening clogged. Obstructed impeller. Obstructed volute.
3. Defective stator. Take unit to authorized service center.
F. Pump runs but delivers small amount of water:| 1. Start and stop pump
several times by plugging and unplugging cord.
2. Clear vent hole in impeller cavity.
Limited Warranty
HYDROMATIC warrants to the original consumer purchaser (“Purchaser” or “You”)
of HYDROMATIC Sump Pumps, Effluent Pumps, Sewage Pumps (other than 2-1/2”),
and Package Systems, that they will be free from defects in material and
workmanship for the Warranty Period of 36 months from date of manufacture.
Our warranty will not apply to any product that, in our sole judgement, has
been subject to negligence, misapplication, improper installation, or improper
maintenance. Without limiting the foregoing, operating a three phase motor
with single phase power through a phase converter will void the warranty. Note
also that three phase motors must be protected by threeleg, ambient
compensated, extra-quick trip overload relays of the recommended size or the
warranty is void. Your only remedy, and HYDROMATIC’s only duty, is that
HYDROMATIC repair or replace defective products (at HYDROMATIC’s choice). You
must pay all labor and shipping charges associated with this warranty and must
request warranty service through the installing dealer as soon as a problem is
discovered. No request for service will be accepted if received after the
Warranty Period has expired. This warranty is not transferable.
EXCEPTIONS: Hydromatic Special Application Pumps, Battery Back-Up Sump
Pumps, Filtered Effluent Pumps, Grinder Pumps, and 2-1/2” Sewage Pumps are
warranted for a period of 12 months from date of purchase or 18 months from
date of manufacture, whichever comes first.
HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR
CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE
AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT
LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or
consequential damages or limitations on the duration of an implied warranty,
so the above limitations or exclusions may not apply to You. This warranty
gives You specific legal rights and You may also have other rights which vary
from state to state. This Limited Warranty is effective June 1, 2011 and
replaces all undated warranties and warranties dated before June 1, 2011.
HYDROMATIC
293 Wright Street, Delavan, WI 53115
Phone: 888-957-8677
Fax: 800-426-9446
Web Site: hydromatic.com