PENTAIR E-03-359 Pultruded Rail System
IMPORTANT!
Read and follow these instructions for adjusting the pultruded rail system
disconnect. Failure to follow these instructions may result in diaphragm
leakage during pumping or guide rail damage.
Step 1 : If disconnect elbow and sealing flange were ordered separately,
the proper diaphragm gap must be set. Complete factory assembled systems are
factory preset and require no adjusting.
Gap-setting Procedure:
- Loosen guide arms on each side of discharge elbow.
- Insert loose sealing flange into guide arms.
- To set the top 1/8″ gap, insert the loose red rubber ring gasket in between the sealing flange and discharge elbow to act as a spacer.
- C-clamp sealing flange to discharge elbow to hold required gap (2 required, snug parts together without tightening).
- Rotate each guide arm to ensure the protruding “block” on each guide arm is up against the sealing flange rib and the guide arm opposite block side is against the sealing flange hanger rods. Torque bolts as follows: 3″ systems: 40 ft/lbs 4″ & 6″ systems: 140 ft/lbs
- Remove c-clamp(s) and rubber gasket. Test gap by pulling out on bottom of the sealing flange. If the flange is adjusted properly, it should not pull back out of set position more than 1/16″. Test disconnect by pulling up on eyebolt (sealing flange should release easily).
Step 2 : Attach supplied chain leg to achieve a three-point lift.
Test the balance of the pump by adjusting the location of the shackle in
reference to individual chain links. The pump must be level to function
properly.
WARNING: If the sealing flange end of pump is raised above the
horizontal, the guide rail may be damaged upon lowering the pump. Ensure pump
is horizontal before lowering the pump into basin.
General Information
Thank you for purchasing your Hydromatic® pump. To help ensure years of trouble-free operation, please read the following manual carefully.
Before Operation
Read the following instructions carefully. Reasonable care and safe methods
should be practiced. Check local codes and requirements before installation.
Attention:
This manual contains important information for the safe use of this product.
Read this manual completely before using this product and refer to it often
for continued safe product use. DO NOT THROW AWAY OR LOSE THIS MANUAL. Keep it
in a safe place so that you may refer to it often.
Unpacking Pump:
Remove pump from carton. When unpacking unit, check for concealed damage.
Claims for damage must be made at the receiving end through the delivery
carrier.
Damage cannot be processed from the factory.
WARNING: Before handling these pumps and controls, always disconnect the power first. Do not smoke or use sparkable electrical devices or flames in a septic (gaseous) or possible septic sump.
CALIFORNIA PROPOSITION 65 WARNING:
This product and related accessories contain chemicals known to the State of
California to cause cancer, birth defects or other reproductive harm.
System Description
In a Hydromatic Pultruded Rail System, the pump is raised and lowered in the basin using a noncorrosive fiberglass I-beam. A unique, patented hydraulic sealing flange at the pump discharge allows the pump to be connected and removed from the discharge elbow with ease at any time without entering the wet well. There is no need to disconnect any piping or electrical connections to remove a pump for inspection or routine maintenance checks. A typical system will operate on float control switches. A bottom float control will turn off the pump(s). An additional float control per pump is then used to turn on the pump(s). In a multiple pump station, the pumps are automatically alternated if using a standard Hydromatic panel. Also, additional float controls may be used to indicate height and/or low water sump conditions. The general equipment for a simplex and duplex system includes the following:
Simplex | Duplex |
---|---|
One pump | Two pumps |
One discharge | Two discharges |
Elbow assembly | Elbow assemblies |
One hydraulic | Two hydraulics |
Sealing flange | Sealing flanges |
One guide rail | Two guide rails |
One lifting chain | Two lifting chains |
One door & frame assembly | Two doors & frame assemblies |
Electrical controls | Electrical controls |
Two level controls | Three level controls |
Pump Not Operating or in Storage:
Pumps with carbon ceramic seals must have impellers manually rotated (6 revolutions) after setting nonoperational for 3 months or longer and prior to electrical start-up. Pumps with tungsten carbide seals must have impellers manually rotated (6 revolutions) after setting nonoperational for 3 weeks or longer and prior to electrical start-up.
Codes:
All codes must be observed. Consult with the local inspector before installation to avoid costly delays. Hydromatic is not responsible for any expense incurred to meet local codes
Installation Instructions
-
1. Concrete Basin(s)
Pour one or two concrete systems (one for pumps and control, etc. and one for valves, if required) or obtain precast concrete rings.
A 45-degree slope may be poured around the inside perimeter of the basin at the bottom to prevent solids buildup providing the slope does not interfere with the discharge elbow and pump locations. Before beginning the installation, refer to the Installation Data as found in the Hydromatic Engineered Products Catalog.
Follow the Installation Data taking into account the location of the discharge pipe, inlet pipe, controls, vent pipe, and anchoring requirements of the discharge elbow(s). (All of the above concrete work to be done by others.) -
Discharge Elbow Installation
See Installation Data for the proper location of the discharge elbow on the basin bottom. Either cast 5⁄8″ anchor bolts into basin bottom protruding 2″ from basin floor with 5⁄8″ lock washers and nuts securing, or drill holes for expansion lag screws to secure elbow to basin bottom. Each elbow requires four anchors (all furnished by others). Each elbow must be level. Length of anchors embedded in concrete varies with materials used, but must be sufficient to withstand the weight, torque, and thrust loads imposed by the pump. -
Discharge Piping (All supplied by others)
Install vertical discharge piping modules to elbow using bolts, nuts, lock washers, and gasket.
NOTE: When increasing the pipe size at the discharge elbow an eccentric flanged reducer coupling may be required to avoid interference with the guide rail. See Installation Data.
Install remainder of the sump discharge piping. This typically includes a vertical run of piping appropriately sized and configured to mate with the vertical discharge piping, a ninety degree elbow, and a horizontal run of piping appropriately sized and configured to mate with the valve box or main piping. Install horizontal run extending through the wall of basin. Secure vertical run to the vertical discharge piping using the appropriate method (i.e., flange, weld, gasketed collar coupling) and grout all piping extending through basin walls.
NOTE: If using flanged connections, be certain that adequate clearances are provided throughout for the installation of bolts, nuts, lock washers, and gaskets.
If total run of vertical piping exceeds twelve (12) feet, install a piping brace at the approximate midpoint of the piping. Secure brace (i.e., U-bolt with angle iron strap and angle iron extensions) to both piping and wall of basin. -
Basin Cover(s)
The basin cover for the sump and valve box can either be poured concrete or precast. If Hydromatic door and frame assemblies are used, locate the concrete openings with respect to the discharge elbow mounting studs as shown in the Installation Data. If the covers are poured, place the door and frame assembly inside the concrete form and position per installation data. Anchor straps are provided on the door frames to secure them to the concrete. If precast covers are used, remove anchor straps from frame before installing into covers. Either cast four 3⁄8″ anchor bolts into the top of the precast cover or drill holes for expansion lag screws. Use either 3⁄8″ nuts or stainless steel bolts to secure door and frame assembly to cover. If valves are to be inside the wet well, provide access ways as required for the piping and valves to access piping shut-off valves (see Installation Data for general dimensions of access ways). Access ways must be covered and secured with tamperproof hardware (by others). -
Guide Rail Installation
Install the pultruded guide rail (I-beam) by attaching the lower end of the guide rail to the slotted lugs on the top side of the discharge elbow. Two 3⁄8″ x 2″ bolts, one rectangular washer, lock washers, and nuts are provided with the discharge elbow parts package. At the top of the guide rail, plumb and then fasten the guide rail to the door & frame assembly or other suitable bracket, using the four 1⁄4″ x 1 stainless steel cap screws.
If Hydromatic door and frame assemblies are not used, obtain suitable upper guide rail brackets (by others) to locate and support the rail(s). A flat surface 4″ wide is required for each rail. -
Intermediate Guide Rail Bracing
Sump depths of 9’6″ and greater require intermediate guide rail bracing. The braces mount on the vertical discharge pipes with U-bolts which are sized according to the discharge pipe size. The number of guide rail braces required are as follows:
Sump Depths
9’6″ to 18’0″ 1 guide rail brace required
18’6″ to 27’0″ 2 guide rail braces required
27’6″ to 30’0″ 3 guide rail braces required
On depths requiring more than one brace, space the braces equally on the pipe and tighten U-bolts. Match drill two 5⁄16″ holes through the guide rail flange and attach with two 1⁄4″ x 1″ stainless steel bolts, nuts, and lock washers provided with braces. Install with bolt heads against the bracket. -
Exterior Piping
Install the inlet hub(s) in side of basin and install inlet piping in hub and grout, or install inlet pipe(s) directly into basin and grout. Install drain pipe from valve box (if required) to basin.
Slope pipe to give proper drainage to basin. Install vent piping in side of basin (if required). Extend piping to a proper elevation above grade (as required by plans and specifications and/or local codes).
All piping furnished by others. See Installation Data for typical piping arrangement. -
Pump and Sealing Flanges
Assemble the sealing flange (with arms) to the pump discharge flange using a gasket between the two. Screw nuts with lock washers on the bottom six studs. Slide the guide rail connector through the sealing flange ears and below the top two studs protruding through the back side of the pump flange. Place the retainer clips on the studs followed by lock washers and nuts and follow illustration. -
Pump Installation
Check all piping braces and supports for proper installation and tightness. Attach the lifting chain assembly or cable to the lifting eye(s) on the top of the pump with the shackle(s) provided. Lower the pump into the basin with the guide rail connector engaged over the pultruded guide rail (I-beam). Ensure that the chain or cable does not interfere with the cord cap assembly. Attach the upper end of lifting assembly to the hook provided on the inside of the Hydromatic door and frame. The heavy rubber sealing diaphragm on the pump discharge should not touch the discharge elbow flange when the pump is being installed or removed, or is installed but not running. Its sole purpose is to flex, due to water pressure when the pump turns on, and form a leakproof seal between the pump and the discharge elbow. -
Float Switches
Mount the float switch mounting bracket to the door and frame assembly using 3/8″ – 16″ stainless steel screws. Include a dielectric gasket (by others) between dissimilar metals to avoid galvanic corrosion. Allow excess float cable to loop over mounting bracket. The sump level is controlled by Hydromatic float switch controls. The float is held in position in the sump by a weight attached to the power cord above the float. The cord supports the float and is adjusted for height from the surface. Duplex systems use three controls: one at all pumps off, one set at one pump on, and one set for both pumps on. Pumps alternate operation on each successive cycle with a Hydromatic Control Panel. The alarm level is usually set above the override (both pumps on) level so the alarm will signal only if the override level is exceeded. However, some engineers prefer to have the alarm set below the override level as it is possible for one pump to fail and the other to operate on the override level with the sump level never reaching the alarm level. Do not let floats rest against basin wall or bottom or entangle with each other or pump(s). -
A. Control Panel on
Mounting Stand When the Control Panel mounting stand is used, either cast four 1⁄2″ anchor bolts into the concrete cover, or drill holes for expansion lag screws and attach stand (bolts or lag screws furnished by others). Insert power and sensor cords from the pumps and all float cords through the bushing in the sump cover. Bolt the panel to the panel stand. (Nuts, bolts, and washers are not supplied.) Make connections between the bottom of the control panel and the basin cover using flexible conduit and conduit seals (by others). When installing pump power cords, make certain that the cords do not rub against the pump or bottom of the basin. Shorten cords to suit the installation. See Bulletin Q-701 for the Installation and Service Manual on the electrical Control Panel system.
11B. Control Panel Mounted
Remote from Basin If the Control Panel is remotely located, instead of on the mounting stand at the basin, install coupling through basin wall. Screw protective bushing from inside basin into coupling (all furnished by others). Make connections outside station using wiring, conduit seals (potted) and conduit to remotely located Control Panel (conduit and seals not furnished). Insert the power and sensor cords through the coupling provided with bushing. Grout in coupling going through sump wall (by others). When installing pump power cords make certain that cords do not rub against pump or on bottom of basin. Shorten cords to suit the installation. See Bulletin Q-701 for the Installation and Service Manual on the electrical Control Panel system.
Electrical Connection:
Make all connections in compliance with N.E.C. and/or local codes.
Connect the control panel ground wire to a good ground. Ground wire must be
grounded properly per N.E.C. and/or local codes. All electrical connections
are to be made by a qualified electrician.
Pump Operations
WARNING: Before handling these pumps and controls, always disconnect the
power first. Do not smoke or use sparkable electrical devices or flames in a
septic (gaseous) or possible septic basin.
See Pump Installation and Service Manual for submersible pump operation on
starting system.
Clean all trash and sticks from basin and connect pump to piping.
Pump Maintenance
Removing Pump from Basin for
Servicing
WARNING: Before handling these pumps and controls, always disconnect the
power first. Do not smoke or use sparkable electrical devices or flames in a
septic (gaseous) or possible septic basin.
To remove a pump from a standard installation (control panel mounted on basin
cover), the power to the control panel is first turned off. Close the plug
valve. Disconnect the power cords and sensor cords in the control panel from
their terminals. Lift out the pump from the basin by means of the chain or
cable.
Disconnect the flexible conduit, power and sensor cords from the control panel. Pull the pump cord down through the pipe coupling while holding the cord on the underside of the basin cover so the cords do not fall into the basin. For reinstalling the pump, reverse the above procedure.
Removing Float Controls for Replacement
To remove a float for replacement from a standard installation (control panel mounted on basin cover), the power is first turned off to the control panel. Disconnect the float leads from the terminals in the control panel. Disconnect the flexible conduit from the control panel. Remove the flexible conduit and the float control leads from the control panel. Pull the pump cord through the pipe coupling while holding the cords on the underside of the basin cover so the cords do not fall into the basin. Remove flexible conduit from potting head. Break out potting from the potting head and remove the float wire. Remove float cord from float cord mounting bracket and remove float from basin. Replace 3900 float by reversing removal procedure. Repot the leads in the potting head according to N.E.C.and/or local codes.
For the removal of the pumps and float controls from system with the control
panel mounted remote from the basin cover, see the Pump Installation and
Service Manual.
WARNING: Before handling these pumps and controls, always disconnect the
power first. Do not smoke or use sparkable electrical devices or flames in a
septic (gaseous) or possible septic basin.
Pump Troubleshooting
The following is a list of common problems and possible solutions. Refer to
Pump Installation and Service Manual for any necessary adjusting, dismantling
or repair work required on the pump.
For Control Panel troubleshooting chart, refer to the Control Panel
Installation and Service Manual Q-701.
Pump runs but does not pump down the basin with the selector switch on either Hand or Automatic position.
-
Impeller may be clogged. Amperage higher than name plate will indicate this.
-
Pump rotation may be wrong. Reversing any two line leads on three phase pumps will reverse the rotation.
-
Discharge plug valve may be closed.
-
Plugging anywhere from impeller to sealing flange. This is evident if no water runs out of sealing flange after raising the pump. Pull the pump from the basin to find the clog.
-
Plugging beyond the sealing flange. This is evident if water does run out when pump is operating when disconnecting the sealing flange from the discharge elbow. Remove the check valve, clean out cover and plug valve and other piping, if necessary, inside valve box to find clog.
Reassemble all valves and piping. If the basin is still not pumped down after the pump is lowered again and the sealing flange is reconnected, proceed in a logical manner to locate and clear the plugging. -
Discharge head may be too high. Check elevation against design point of pump.
-
Improper discharge flow. Check for correct impeller size and proper voltage.
-
Check for possible broken or clogged forced main.
Basin level is pumped down with selector switch on Hand position, but is not pumped down with selector switch on Automatic position.
- Floats are not hanging free in the basin or are covered with debris. Pump the level down with the selector switch on Hand, so that the floats can be observed. Relocate and clean all floats as necessary.
- If this is a new installation and original start-up, the floats may be miswired into the control panel. Recheck the wiring diagrams and schematics in the panel. If the start and stop floats are hooked in reverse, the pump will short cycle on and off and will not pump the level down.
- Floats or alternator are malfunctioning. Pull the floats out of the basin, clean them and lay them on the ground.
Lift up the stop (lower) float in the left hand, the start (upper) float in the right hand and with the bulbs hanging free, turn selector switch to Automatic. Lower the left hand until the float hits the ground and lies on its side. Nothing should happen. After lowering the right hand in the same manner, the pump should start. When raising the right hand to suspend the float, the pump should continue to run. The pump should stop when raising the left hand to suspend the float. If this procedure does not cause the pump to operate as described, either order new float switches or replace alternator relay.
PULTRUDED RAIL SYSTEM
STANDARD LIMITED WARRANTY
Pentair Hydromatic® warrants its products against defects in material and
workmanship for a period of 12 months from the date of shipment from Pentair
Hydromatic or 18 months from the manufacturing date, whichever occurs first –
provided that such products are used in compliance with the requirements of
the Pentair Hydromatic catalog and technical manuals for use in pumping raw
sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids.
During the warranty period and subject to the conditions set forth, Pentair
Hydromatic, at its discretion, will repair or replace to the original user,
the parts that prove defective in materials and workmanship. Pentair
Hydromatic reserves the right to change or improve its products or any
portions thereof without being obligated to provide such a change or
improvement for prior sold and/or shipped units. Start-up reports and
electrical schematics may be required to support warranty claims. Submit at
the time of start up through the Pentair Hydromatic website:
http://forms.pentairliterature.com/startupform/startupform.asp?type=h.
Warranty is effective only if Pentair Hydromatic authorized control panels are
used. All seal fail and heat sensing devices must be hooked up, functional and
monitored or this warranty will be void. Pentair Hydromatic will cover only
the lower seal and labor thereof for all dual seal pumps. Under no
circumstance will Pentair Hydromatic be responsible for the cost of field
labor, travel expenses, rented equipment, removal/reinstallation costs or
freight expenses to and from the factory or an authorized Pentair Hydromatic
service facility.
This limited warranty will not apply: (a) to defects or malfunctions resulting
from failure to properly install, operate or maintain the unit in accordance
with the printed instructions provided; (b) to failures resulting from abuse,
accident or negligence; (c) to normal maintenance services and parts used in
connection with such service; (d) to units that are not installed in
accordance with applicable local codes, ordinances and good trade practices;
(e) if the unit is moved from its original installation location; (f) if unit
is used for purposes other than for what it is designed and manufactured; (g)
to any unit that has been repaired or altered by anyone other than Pentair
Hydromatic or an authorized Pentair Hydromatic service provider; (h) to any
unit that has been repaired using non factory specified/ OEM parts.
Warranty Exclusions: Pentair HYDROMATIC MAKES NO EXPRESS OR IMPLIED WARRANTIES
THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. Pentair HYDROMATIC
SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR ANY PARTICULAR PURPOSE.
Liability Limitation: IN NO EVENT SHALL Pentair HYDROMATIC BE LIABLE OR
RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR
RELATED IN ANY MANNER TO ANY Pentair HYDROMATIC PRODUCT OR PARTS THEREOF.
PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION.
Pentair HYDROMATIC DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS
WARRANTY, FOR IMPROPER INSTALLATION. Pentair HYDROMATIC RECOMMENDS
INSTALLATION BY PROFESSIONALS.
Some states do not permit some or all of the above warranty limitations or the
exclusion or limitation of incidental or consequential damages and therefore
such limitations may not apply to you. No warranties or representations at any
time made by any representatives of Pentair Hydromatic shall vary or expand
the provision hereof.
Customer Support
740 EAST 9TH STREET 490 Pinebush Road, Unit #4
ASHLAND, OHIO, USA 44805 CAMBRIDGE, ONTARIO, CANADA N1T 0A5
419-289-1144 800-363-PUMP
WWW.HYDROMATIC.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>